TERMINAL AUTOMATION SYSTEM PROJECT AT SITARGANJ IRD
21000473-HD-10157
21000473-HD-10157
Open Tender
Two Bid
Unknown (Unspecified Location)
₹0
Exempted
14 Sept 2021
19 Aug 2021
14 Sept 2021
14 Sept 2021
23 Aug 2021 - 7 Sept 2021
27 Aug 2021
| Item No | Item Title | Description | Qty | Unit |
|---|---|---|---|---|
| 125 | Sup 3CX2.5 FRLS | Sup 3CX2.5 FRLS — CABLE,ELECTRICAL,ARMOURED; APPLICATION:POWER; VOLTAGE RATING:1.1 KV; CONSTRUCTION:PVC INSULATED; MATERIAL,CONDUCTOR:COPPER; MATERIAL,INSULATION:POLY VINYL CHLORIDE; ARMOURING:MESH ARMOURED; NUMBER OF CORES:3 CORE; CROSS SECTION,CORES:2.5 MM2 126 Laying 3CX2.5 11308- Meters 1250 Yes LAYING OF CABLES : SIZES ABOVE 2.5 SQMM UPTO AND INCLUDING 3 1/2 CORE X 50 SQMMLONG DESCRIPTION LAYING OF CABLES IN THE UNDERGROUND EXACAVATED TRENCH OR PERMANENT CONCRETE CABLE TRENCH : PVC / XLPE / PILC, COPPER OR ALUMINIUM CONDUCTOR CABLES. | - | Meters |
| 127 | Sup 3CX2.5 FS | Sup 3CX2.5 FS — CABLE,ELECTRICAL,ARMOURED; VOLTAGE RATING:1.1 KV; MATERIAL,CONDUCTOR:COPPER; MATERIAL,INSULATION:CROSS LINKED POLYETHYLENE; MATERIAL,INNER SHEATH:EXTRUDED PVC; MATERIAL,OUTER SHEATH:POLY VINYL CHLORIDE; MATERIAL,ARMOURING:GALVANISED IRON ROUND WIRE; NUMBER OF CORES:3 CORE; CROSS SECTION,CORES:2.5 MM2; STANDARD:2XWY,CORES COLOUR CODED,LAID UP TYPE ST2 INNER SHEATHED,OVERALL PVC TYPE ST2 SHEATHED,DESIGN SPEC:IS 7098 PART 1 128 Laying 3CX2.5 FS 11308- Meters 50 Yes LAYING OF CABLES : SIZES ABOVE 2.5 SQMM UPTO AND INCLUDING 3 1/2 CORE X 50 SQMMLONG DESCRIPTION LAYING OF CABLES IN THE UNDERGROUND EXACAVATED TRENCH OR PERMANENT CONCRETE CABLE TRENCH : PVC / XLPE / PILC, COPPER OR ALUMINIUM CONDUCTOR CABLES. 129 Sup 6CX2.5 FRLS 11308- Running Meter 200 Yes CABLE,ELECTRICAL,ARMOURED; VOLTAGE RATING:1.1 KV; MATERIAL,CONDUCTOR:COPPER; MATERIAL,INSULATION:POLYVINYL CHLORIDE; MATERIAL,OUTER SHEATH:POLYVINYL CHLORIDE; STANDARD/FRLS:FRLS; MATERIAL,ARMOURING:GALVANISED STEEL STRIP; NUMBER OF CORES:6 CORE; CROSS SECTION,CORES:2.5 SQ.MM 130 Laying of above 11308- Running Meter 200 995423 Yes LAYING OF 6CX2.5MM2 FRLS POWER CABLE | - | Meters |
| 131 | Sup 12CX2.5 FRLS | Sup 12CX2.5 FRLS — CABLE,ELECTRICAL,ARMOURED; APPLICATION:POWER; VOLTAGE RATING:1.1 KV; CONSTRUCTION:PVC INSULATED; MATERIAL,CONDUCTOR:COPPER; MATERIAL,INSULATION:POLY VINYL CHLORIDE; MATERIAL,OUTER SHEATH:EXTRUDED PVC; ARMOURING:GALVANISED STRIP WIRE ARMOURED; NUMBER OF CORES:12 CORE; CROSS SECTION,CORES:2.5 MM2; DESIGN SPEC:IEC 502,COLOUR OUTER SHEATH:BLACK 132 Laying of above 11308- Meters 150 Yes LAYING OF CABLES : SIZES ABOVE 2.5 SQMM UPTO AND INCLUDING 3 1/2 CORE X 50 SQMMLONG DESCRIPTION LAYING OF CABLES IN THE UNDERGROUND EXACAVATED TRENCH OR PERMANENT CONCRETE CABLE TRENCH : PVC / XLPE / PILC, COPPER OR ALUMINIUM CONDUCTOR CABLES. | - | Meters |
| 133 | Sup 24CX2.5 FRLS | Sup 24CX2.5 FRLS — CABLE,ELECTRICAL,ARMOURED,FIRE SPEC; APPLICATION:POWER; FLAMMABILITY PROPERTIES:FLAME RETARDANT; VOLTAGE RATING:1.1 KV; MAT,CONDUCTOR WIRE:COPPER; MAT SPEC,INSULATION:POLY VINYL CHLORIDE; ARMOURING:GALVANISED STRIP WIRE ARMOURED; MAT SPEC,OUTER SHEATH:POLY VINYL CHLORIDE; NUMBER OF CORES:24 CORE; CROSS SECTION,CORES:2.5 MM2 134 Laying of above 11308- Meters 1000 Yes LAYING OF CABLES : SIZES ABOVE 2.5 SQMM UPTO AND INCLUDING 3 1/2 CORE X 50 SQMMLONG DESCRIPTION LAYING OF CABLES IN THE UNDERGROUND EXACAVATED TRENCH OR PERMANENT CONCRETE CABLE TRENCH : PVC / XLPE / PILC, COPPER OR ALUMINIUM CONDUCTOR CABLES. | - | Meters |
| 135 | Sup 2CX1.5 FRLS | Sup 2CX1.5 FRLS — LAYING OF CABLES : SIZES ABOVE 2.5 SQMM UPTO AND INCLUDING 3 1/2 CORE X 50 SQMMLONG DESCRIPTION LAYING OF CABLES IN THE UNDERGROUND EXACAVATED TRENCH OR PERMANENT CONCRETE CABLE TRENCH : PVC / XLPE / PILC, COPPER OR ALUMINIUM CONDUCTOR CABLES. 137 Sup 2CX1.5 FS 11308- Running Meter 200 Yes CABLE,ELECTRICAL,ARMOURED; VOLTAGE RATING:1100 V; MATERIAL,CONDUCTOR:COPPER; MATERIAL,INSULATION:XLPE; MATERIAL,INNER SHEATH:POLYVINYL CHLORIDE; ARMOURING:GALVANISED IRON ROUND/STRIP; NUMBER OF CORES:2 CORE; CROSS SECTION,CORES:1.5 MM2; ADDITIONAL INFORMATION:FIRE SURVIVAL, CONTROL CABLE; CONFIRMING TO IEC-60794-3/ISO 11801-2/EN 50 173-1, AS PER IS 10810 (PART- 62)CATEGORY AF; AS PER TENDER SPECIFICATIONS AND APPROVED DATASHEETS 138 Laying of above 11308- Meters 200 Yes LAYING OF CABLES : SIZES ABOVE 2.5 SQMM UPTO AND INCLUDING 3 1/2 CORE X 50 SQMMLONG DESCRIPTION LAYING OF CABLES IN THE UNDERGROUND EXACAVATED TRENCH OR PERMANENT CONCRETE CABLE TRENCH : PVC / XLPE / PILC, COPPER OR ALUMINIUM CONDUCTOR CABLES. | - | Meters |
| 139 | Sup 4CX1.5 FRLS | Sup 4CX1.5 FRLS — CABLE,ELECTRICAL,ARMOURED; VOLTAGE RATING:660 V; MATERIAL,CONDUCTOR:COPPER; MATERIAL,INSULATION:CROSS LINKED POLYETHYLENE; MATERIAL,INNER SHEATH:POLYVINYL CHLORIDE TYPE C; MATERIAL,OUTER SHEATH:POLYVINYL CHLORIDE TYPE ST2; STANDARD/FRLS:FRLS; NUMBER OF CORES:4; CROSS SECTION,CORES:1.5 MM2; THE CABLE SHALL BE OF POLYCAB/NICCO/CCI/FINOLEX MAKE. PRIMARY INSULATION-EXTRUDED PVC COMPOUND AS PER IS 5381 TYPE C. MIN THICKNESS 0.7 MM; INNER SHEATH:MIN THICKNESS 0.7 MM AS PER IS 5831; OUTER SHEATH MIN THICKNESS 1.4 MM; BLACK COLOUR. ARMOUR-SHALL BE PROVIDED OF GALVANIZED STEEL WIRE/FLAT STRIP (1.4 MM. WIRE FOR 2-PAIRS AND 4X0.8 MM STRIP FOR MULTI-PAIR). ELECTRICAL CHARACTERISTICS-MAX. RESISTANCE OF THE CONDUCTOR OF THE CABLE SHALL NOT EXCEED 12.3 OHM/KM AT 20 DEG C. CORE IDENTIFICATION-CORE IDENTIFICATION NUMBER SHALL BE PROVIDED AT A DISTANCE OF NOT MORE THAN 1 METER. MANUFACTURER TEST CERTIFICATE OF CABLES TO BE SUBMITTED. 140 Laying of above 11308- Meters 1000 Yes LAYING OF CABLES : SIZES ABOVE 2.5 SQMM UPTO AND INCLUDING 3 1/2 CORE X 50 SQMMLONG DESCRIPTION LAYING OF CABLES IN THE UNDERGROUND EXACAVATED TRENCH OR PERMANENT CONCRETE CABLE TRENCH : PVC / XLPE / PILC, COPPER OR ALUMINIUM CONDUCTOR CABLES. 141 Sup 6CX1.5 FRLS 11308- Running Meter 400 Yes CABLE,ELECTRICAL,ARMOURED; VOLTAGE RATING:1.1 KV; MATERIAL,CONDUCTOR:COPPER; MATERIAL,INSULATION:POLYVINYL CHLORIDE; MATERIAL,OUTER SHEATH:POLYVINYL CHLORIDE; STANDARD/FRLS:FRLS; MATERIAL,ARMOURING:STEEL STRIP; NUMBER OF CORES:6 CORE; CROSS SECTION,CORES:1.5 SQ.MM 142 Laying of above 11308- Running Meter 400 995423 Yes LAYING OF 6CX1.5MM2 FRLS CONTROL CABLE 143 Sup 8CX1.5 FRLS 11308- Running Meter 250 Yes CABLE,ELECTRICAL,ARMOURED; VOLTAGE RATING:N/A; MATERIAL,CONDUCTOR:COPPER; MATERIAL,INSULATION:POLY VINYL CHLORIDE; MATERIAL,INNER SHEATH:EXTRUDED PVC; ARMOURING:WIRE/STRIP; MATERIAL,ARMOURING:GI; NUMBER OF CORES:8 C; CROSS SECTION,CORES:1.5 SQ.MM; HEAVY DUTY FRLS CONTROL CABLE 144 Laying of above 11308- Meters 250 Yes LAYING OF CABLES : SIZES ABOVE 2.5 SQMM UPTO AND INCLUDING 3 1/2 CORE X 50 SQMMLONG DESCRIPTION LAYING OF CABLES IN THE UNDERGROUND EXACAVATED TRENCH OR PERMANENT CONCRETE CABLE TRENCH : PVC / XLPE / PILC, COPPER OR ALUMINIUM CONDUCTOR CABLES. 145 Sup 12CX1.5 FRLS 11308- Running Meter 250 Yes CABLE,ELECTRICAL,ARMOURED; VOLTAGE RATING:N/A; MATERIAL,CONDUCTOR:COPPER; MATERIAL,INSULATION:POLY VINYL CHLORIDE; MATERIAL,INNER SHEATH:EXTRUDED PVC; ARMOURING:WIRE/STRIP; MATERIAL,ARMOURING:GI; NUMBER OF CORES:12 C; CROSS SECTION,CORES:1.5 SQ.MM; HEAVY DUTY FRLS CONTROL CABLE 146 Laying of above 11308- Meters 250 Yes LAYING OF CABLES : SIZES ABOVE 2.5 SQMM UPTO AND INCLUDING 3 1/2 CORE X 50 SQMMLONG DESCRIPTION LAYING OF CABLES IN THE UNDERGROUND EXACAVATED TRENCH OR PERMANENT CONCRETE CABLE TRENCH : PVC / XLPE / PILC, COPPER OR ALUMINIUM CONDUCTOR CABLES. | - | Meters |
| 147 | Sup 16CX1.5 FRLS | Sup 16CX1.5 FRLS — CABLE,ELECTRICAL,ARMOURED; VOLTAGE RATING:N/A; MATERIAL,CONDUCTOR:COPPER; MATERIAL,INSULATION:PVC; MATERIAL,INNER SHEATH:EXTRUDED PVC; MATERIAL,OUTER SHEATH:FRLS PVC; STANDARD/FRLS:IS 1554; MATERIAL,ARMOURING:GI WIRE/STRIP; NUMBER OF CORES:16 CORE; CROSS SECTION,CORES:1.5 MM2; HEAVY DUTY, NUMBER OF STRAND:MULTI STRAND, IN ADDITION TO THIS, SPECIFICATIONS MENTIONED IN TENDER MUST BE FOLLOWED 148 Laying of above 11308- Running Meter 500 995423 Yes LAYING OF 16C X 1.5 SQ.MM FLAME RETARDANT LOW SMOKE CONTROL CABLE. | - | Running Meter |
| 149 | Sup 18CX1.5 FRLS | Sup 18CX1.5 FRLS — CABLE,ELECTRICAL,ARMOURED; VOLTAGE RATING:N/A; MATERIAL,CONDUCTOR:COPPER; MATERIAL,INSULATION:PVC; MATERIAL,INNER SHEATH:EXTRUDED PVC; MATERIAL,OUTER SHEATH:FRLS PVC; STANDARD/FRLS:IS 1554; MATERIAL,ARMOURING:GI WIRE/STRIP; NUMBER OF CORES:16 CORE; CROSS SECTION,CORES:1.5 MM2; HEAVY DUTY, NUMBER OF STRAND:MULTI STRAND, IN ADDITION TO THIS, SPECIFICATIONS MENTIONED IN TENDER MUST BE FOLLOWED 150 Laying of above 11308- Meters 700 Yes LAYING OF CABLES : SIZES ABOVE 2.5 SQMM UPTO AND INCLUDING 3 1/2 CORE X 50 SQMMLONG DESCRIPTION LAYING OF CABLES IN THE UNDERGROUND EXACAVATED TRENCH OR PERMANENT CONCRETE CABLE TRENCH : PVC / XLPE / PILC, COPPER OR ALUMINIUM CONDUCTOR CABLES. | - | Running Meter |
| 151 | Sup 24CX1.5 FRLS | Sup 24CX1.5 FRLS — CABLE,ELECTRICAL,ARMOURED; APPLICATION:INTERCONNECTION/FIELD; VOLTAGE RATING:1.1 KV; CONSTRUCTION:PVC INSULATED; MATERIAL,CONDUCTOR:COPPER; MATERIAL,INSULATION:POLY VINYL CHLORIDE; MATERIAL,OUTER SHEATH:EXTRUDED PVC; ARMOURING:GALVANISED STRIP; NUMBER OF CORES:24 CORE; CROSS SECTION,CORES:1.5 MM2; DESIGN SPEC:IS 1554 (PART I),COLOUR OUTER SHEATH:BLACK 152 Laying of above 11308- Meters 1200 Yes LAYING OF CABLES : SIZES ABOVE 2.5 SQMM UPTO AND INCLUDING 3 1/2 CORE X 50 SQMMLONG DESCRIPTION LAYING OF CABLES IN THE UNDERGROUND EXACAVATED TRENCH OR PERMANENT CONCRETE CABLE TRENCH : PVC / XLPE / PILC, COPPER OR ALUMINIUM CONDUCTOR CABLES. | - | Meters |
| 153 | Sup 36CX0.5 FRLS | Sup 36CX0.5 FRLS — CABLE,ELECTRICAL,ARMOURED; VOLTAGE RATING:N/A; MATERIAL,CONDUCTOR:COPPER; MATERIAL,INSULATION:POLY VINYL CHLORIDE; MATERIAL,INNER SHEATH:EXTRUDED PVC; MATERIAL,OUTER SHEATH:POLY VINYL CHLORIDE; MATERIAL,ARMOURING:GALVANISED STRIP/WIRE; NUMBER OF CORES:36; CROSS SECTION,CORES:0.5 SQ.MM; TYPE:FLAME RETARDANT LOW SMOKE,CONFORMING TO IS 1554 154 Laying of above 11308- Running Meter 200 995423 Yes LAYING OF 36CX0.5 SQ.MM CONTROL/POWER CABLE. | - | Running Meter |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
21000473-HD-10157.pdf
TENDER_DOCUMENT • 22.14 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .