Tender Value
₹22.4 Cr
EMD Value
₹11.2 L
Closing Date
2 Feb 2024, 5:30 pmClosed
Executive Engg Elect Office Pwd Chh Sambhajinagar
Executive Engineer, (Elect) Office Public Works Departments Jalna Road, Chh. Sambhajinagar
Providing Solar LED street Lights, LED Highmast and MSEDCL Line shifting for proposed four Lane roadfrom Nagar naka Padegaon Daultabad T Point NH 52 Near Chh. Sambhaji Nagar Dist. Ch Sambhaji Nagar
2024_PWDM_987395_1
Est No. 113048/Notice No.51/2023-24
Open Tender
Electrical Works
540 days
Chh. Sambhajinagar
Please refer Tender documents.
3 documents required · 3 mandatory
₹3,540
₹11.2 L
Office of the Chief Engg Elect Mumbai
1 Jul 2025
19 Jan 2024
6 Feb 2024
19 Jan 2024
2 Feb 2024
19 Jan 2024
25 Jan 2024
Amount
Supplying, erecting and commissioning of All-in-one integrated Smart battery management LED solar streetlight with solar photovoltaic module, battery, battery management system, control electronics, LED driver, inter-connecting cables and pole mounting piece integrated into the luminaries as a single unit with : 1. LUMINARIES: 70 W luminaries with highly efficient mid power white dimmable LEDs with lumen output of Minimum 10500 +/-10% Lumens with SMART Battery Management System Inbuilt, and a typical corelated color temperature of 5700K with CRI>70 and lenses with efficient bat wing optics designed for efficient light distribution for secondary roads. The Lumens Output of the Fitting shall be of Minimum 8400 Lumens with LM79 Report from Any NABL Accredited Lab with efficacy Minimum 150 Lumens / Watts. Life will be 50000 Burning hours life class & LM 79 & LM 80 of the Fitting and LED & Luminaries RAL 7011 with OEM Name Embossment. 2. Charge Controller : Highly efficient, integrated microprocessor based MPPT charge controller with Smart Battery Management driver mounted on the same board to minimize power loss & communication device in order to communicate to a suitable programming user interface. 3. Solar Module: The Solar Cell shall be made of Premium grade mono crystalline silicon Cell with 100 Wp at 18 Vmpp. its Construction shall be of Low iron tempered glass with low reflection characteristics and with rated IP 65/IP66. The Compliance Standards shall be IEC 61215 For Design; IEC 61701 Performance & IEC 61730 (Safety Class I & II). 4 BATTERY :The Battery shall be minimum 54Ah Rechargeable Lithium Ferro Phosphate (LiFePo4) Battery Pack and Should perform Smart battery diagnostic, such as state of the charge (SOC) estimation, state of health(SOH) estimation and state of power (SOP) estimation with high efficiency battery witk higher life of >2000 cycles 5 Housing : The luminaries with single piece pressure die cast LM6 aluminum housing with Proper OEM Brand Name Embossment for ensuring quality &ruggedness and excellent heat dissipation with IP 65/IP66 protection 6 Mounting Bracket:The luminaries shall have a specially designed pole mounting piece having length 1 - 1.5 mtr length that enables lateral as well as post top mounting and installation It shall be suitable for mounting on pole of diameter 40 – 70mm [with 5 years on site warranty complete]. [ for 2 km road considering 25 mtr spacing , total quantity 160 nos]
Providing & erecting 9 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 155 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP
Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 9m & 10m high octagonal /conical GI pole).
Supplying and erecting 20mm dia. corrugated flexible polypropylene conduit
Supplying and erecting integrated LED flood light fitting Max. 195W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 23400 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2. [8 nos of LED flood light per highmast * 20 nos = 160 nos]
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Supplying and erecting outdoor stand mounted feeder pillar for high-mast of the same manufacturer with 32A TPN MCB incomer, 24hr astronomical time switch with minimum 5 years battery backup, IP 54 and IK10 protection, 25 A TP contactor for automatic switching of luminaires, 2 no. 9A contactors and raise/lower push button, and provision for termination of adequate size of incoming and outgoing cables complete erected in min. 14 SWG CRCA sheet box with supporting angles, self lock, gasket and slanting top erected on CC foundation complete.
Supplying and erecting outdoor stand mounted feeder pillar for high-mast of the same manufacturer with 63A TPN MCB incomer, 24hr astronomical time switch with minimum 5 Years battery backup, , IP 54 and IK10 protection, 45 A TP contactor for automatic switching of luminaires, 2 no 9A contactors and raise/lower push button, and provision for termination of adequate size of incoming and outgoing cables complete erected in min. 14 SWG CRCA sheet box powder coated with supporting angles, self lock, gasket and slanting top erected on CC foundation complete.
Supplying and erecting 12.5 m (clear height) motorized high-mast (Top -150mm, Bottom- 360mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per BSEN - 10025 S 355/E350 & 3mm thickness, with base plate 25 mm thick x OD 520 mm grade as per IS-2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 5mm, SG-DG U clamps, double drum with assembly 250 kg, 5x2.5 Sq.mm. flexible copper cable with lantern carriage assembly suitable for max. 12 nos. luminaires and its control gear box, lightning arrestor, arrangement for fixing aviation light, high-mast with serial number, factory inspection report/test report of high-mast should be provided as per specifications on provided foundation J type stud/bolts with necessary accessories complete as per specification no. OH-PL/HM (excluding luminaries)
Supplying and erecting 16 m (clear height) motorized high-mast (Top-150mm, Bottom-410 mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per BSEN -10025 S 355/E350 & 3 mm thickness, with base plate 25 mm thick x OD 570 mm grade as per IS-2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 6 mm, SG-DG U clamps, double drum winch assembly 350 kg, 5x2.5 sq.mm flexible copper cable with lantern carriage assembly suitable for max. 16 nos. luminaires and its control gear box, lightning arrestor, arrangement for fixing aviation light, high-mast with serial number, factory inspection report/test report of high-mast should be provided as per specifications on provided foundation J type stud/bolts with necessary accessories complete. specification no. OH-PL/HM (excluding luminaries)
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. [25 x 3 , 6 kg/ highmast = 6*20 = 120 kg]
Making M- 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 12.5 m raising lowering high mast).
Making M- 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 16 m raising lowering high mast).
Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV
Supplying and erecting integrated LED street light fitting 85-90W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 9300 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
Supplying and erecting integrated LED flood light fitting Max. 195W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 23400 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2.
Supplying and erecting LED Strip light 5m Length Max. 45 W IP20 class having minimum lumens output of 800 Lumens/m, min. efficacy of 90 lumen/W, CRI>80, CCT upto 5000K, Beam Angle of 110 deg., THD<10%, p.f. >0.95, operating range of 230-270V, Life class of 30,000 Hrs. at L70B50, including driver with 1 year warranty.
Supplying and erecting triple pole mini feeder pillar with 500V, 200A FPMCCB as incomer and 2 outgoing circuits with HRC fuse base and cartridge of 100A with aluminium bus bar erected in 14 SWG CRCA sheet box with supporting angles, self locks, gasket having IP54,IK10 protection and slanting top to be erected on provided foundation complete as per specification no. SW-SWR/MFP
Supplying, erecting & marking SPMCB 0.5A to 5A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. [10 kg per pole x 272 no of poles = 2720 nos]
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying & erecting G.I. pipe ‘A’ class 40 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Providing & erecting 9 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 155 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL
Providing and erecting galvanised 1000mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP [2 x 5 = 10 for mini piller & 10 nos for street light control panel = 20 nos]
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP
Excavating hard murum / stone metal road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site as required complete.
Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose).
Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 9m & 10m high octagonal /conical GI pole).
Supplying and erecting rolled steel joist (girder) pole 152 x 152 mm (37.1 kg/m) with base plate in provided foundation as per specification no. OHPL/ RSJ
Making cement concrete foundation including excavation (60 x 60) cm x deep 1/6 of pole length in 1:3:6 cement concrete 20 x 25 mm stone metal, 45 cm x 45 cm x 45 cm /45 cm dia. x 45 cm. height plinth duly plastered, with necessary curing and finishing complete. (for above 9 m poles)
Supplying and erecting G.I. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, G.I. stay wire 7/8 SWG, G.l. stay rod 20 mm x 1.8 m length and pole clamps duly erected in provided cement concrete foundation.
Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete, (20 to 25) mm stone metal with necessary curing and finishing complete.(for stay).
Providing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.l. Rod complete with all materials as per specification no. EAEP
Supplying & erecting 100 x 50 x 6 mm with 4.7 mm thick web and 7.5 mm thick flange channel iron cross arm of suitable length for 2.4 m wide DP structure and erecting on DP with 50x6mm clamp complete as per specification no. OHPL/ BKT
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supplying and erecting porcelain disc type insulator 70 KN with necessary hardware suitable for 33kV line complete as per specification no. OH-INS/DI
Supplying and erecting GI sheet 1.6mm (16 SWG) caution board of size 200 x 150 mm mm duly painted with red oxide and enamel paint in Marathi and Hindi erected at position for HV/EHV installation.
Supplying & erecting barbed wire two ply with 12 SWG ply and 12 SWG barb with a gap between two bars of 75 mm. firmly fixed on provided angle supports with necessary materials complete. (6.044 meters/kg.).
Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (round) cable 33 kV(UE), 3 x 300 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT
Providing and erecting Heat shrinkable outdoor termination kit for 33 kV ( E )/33 kV (UE) XLPE HT cable 3x300 sq. mm. to 400 sq. mm. with necessary material as per specification no. CB-JT/HT
Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete
Supplying & laying (including excavation) half round reinforced cement concrete pipe of IS 458:2003 NP-2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
Supplying, erecting and commissioning of 33 KV Isolators Without EB (800Amp ) complete with accessories 3-phase, triple pole, double break, gang operated, centre rotating type Isolator with / without gang operated Earth switches, including Insulators and complete in all respects with arcing horns , bimetallic connectors, operating mechanism, indicating devices, fixing details etc. i ) System frequency with + 3 % variation ( Hz) : 50 ii) Nominal system voltage (KV r.m.s.) : 33 ,iii) Maximum system voltage (KV r.m.s.)/ Rating Voltage : 36,v) Maximum continuous current rating (Amps.) : 800 Amp,v) Rated short time current for 3 seconds (KA r.m.s) : 28.8 ,vi) Rated peak withstand current (KA peak) : 72,vii) 1.2/50 micro-sec lightning impulse withstand voltage (KV peak) a) To earth and between poles : 170 b) Across the isolating distance : 195, viii) Rated one minute power frequency withstand voltage ( KV r.m.s.) a) To earth and between poles : 70 b) Across the isolating distance : 80 ix) No. of poles : 3 With all accessories complete (Detail technical specification attached seperately)
Supplying, erecting and commissioning 33 KV Potential Transforemer complete with all accessories with equipment 33 KV, Out Door, Single Phase, Oil Cooled Potential Transformer Reference Standard IS : 3156 Type Dead tank Rated voltage 33 KV Highest voltage 36 KV Frequency 50 Hz.Basic Insulation Level Primary : 36 KV / 70 KV / 170 KV(p) Secondary : 3 KV for 1 minute Class of insulation Class A Creepage distance 900 mm (minimum) Ratio 33000/√3 : 110/√3 – 110/√3 Volt Class of accuracy Core - I : 0.5, Core - II : 3P Burden Core - I : 100 VA, Core - II : 100 VA Voltage factor 1.2 Continuous, 1.5 times for 30 Sec. Core identification Core - I : Metering, Core - II : Protection Place of installation Out Door, Structure mounted Primary terminal connector Rigid type suitable for PT Stud to Dog ACSR Fixing hole dimension 330 mm both X & Y direction Painting Paint shed : Battleship gray as per IS 5 Paint thickness : 60 micron ( minimum) Secondary terminal box IP 55 ( Detail technical specification attached seperately)
Supplying and erecting testing and commissioning 33 kV Current transformer having current ratio between 400-200/1 Amp with structre and necessary hardware on provided foundation complete .with maximum creepage distance (mm):-900,clear ht.-450mm ,kVrms=3kV,cORE-1 Metering.Core-ii -protection,core-iii-Diff.Protection,Burden:-20VA,Class of acciuracy=0.25/5p10/ps,Primaery terminal requirement-two,30mm dia. x80mm length,Mounting Freame size-450mm x450mm,mounting holes ,dia.30mm etc.(Detail Technical Specification attached seperately)
Dismantling the existing pole above 6 m height with brackets, clamps, insulators, stay from the c.c. foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level.
Dismantling the existing overhead line including G.I. wires of all sizes without damaging & making the coils in suitable sizes.
Supplying and erecting ACSR conductor of size - 6/1-4.72 mm (Dog) complete. (394.00 kg/km) as per specification No. OH-CON/ACSR [proposed if required]
Supplying and erecting rolled steel joist (girder) pole 152 x 152 mm (37.1 kg/m) with base plate in provided foundation as per specification no. OHPL/ RSJ
Making cement concrete foundation including excavation (60 x 60) cm x deep 1/6 of pole length in 1:3:6 cement concrete 20 x 25 mm stone metal, 45 cm x 45 cm x 45 cm /45 cm dia. x 45 cm. height plinth duly plastered, with necessary curing and finishing complete. (for above 9 m poles) [20 for dp strutue + 44 for poles]
Supplying and erecting G.I. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, G.I. stay wire 7/8 SWG, G.l. stay rod 20 mm x 1.8 m length and pole clamps duly erected in provided cement concrete foundation. [20 for dp strutue + 44 for poles]
Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete, (20 to 25) mm stone metal with necessary curing and finishing complete.(for stay).
Providing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.l. Rod complete with all materials as per specification no. EAEP
Supplying & erecting single pole cut point channel set of for 11/33 kV HT OH line, two channel of size 100 x 50 x 6 mm 1.6 m long having stud angle of size 50 x 50 x 6 mm 1.5 m long with necessary clamps, nut bolts etc. complete.
Supplying and erecting porcelain disc type insulator 70 KN with necessary hardware suitable for 33kV line complete as per specification no. OH-INS/DI
Supplying and erecting porcelain pin type insulator with GI pin suitable for 33kV line, complete as per specification no. OH-INS/PN
Supplying and erecting ACSR conductor of size - 6/1-4.09 mm (Raccoon) complete. (318.00 kg/km) as per specification No. OH-CON/ACSR [proposed if required]
Supplying and erecting GI sheet 1.6mm (16 SWG) caution board of size 200 x 150 mm mm duly painted with red oxide and enamel paint in Marathi and Hindi erected at position for HV/EHV installation.
Supplying & erecting barbed wire two ply with 12 SWG ply and 12 SWG barb with a gap between two bars of 75 mm. firmly fixed on provided angle supports with necessary materials complete. (6.044 meters/kg.).
Supplying and erecting bracket for guarding of HT OH Line, made from channel iron 1600 mm in length and 75x40x6 mm. erected on pole complete as per specification no. OH-PL/VCA
Supplying and erecting GI earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws in an approved manner.
Supplying and erecting guarding lace for HT OH line with 8SWG G.l. wire to protect the HT OH line with binding wire of 20SWG G.l. wire for 75mm section on either side.
Supplying and erecting 11 kV outdoor type gang operated air break, triple pole switch 400 A capacity with 3 post pin type insulator per phase, mounted in horizontal or vertical position with necessary channels on provided cross arm with adequate length of "C" class G.l. pipe for operating handle erected on extended square shaft. The operating handle provided with lock and key at suitable height from ground level with necessary clamp.
Supplying, erecting, testing and commissioning of 11 KV HT feeder pillar of 4 way type, suitable for 11kV,3 PH, 50 Hz, 630 Amps, AC system. 11 KV HT feeder pillar shall be floor mounted type suitable for outdoor type installation, All components used in the manufacture of the pillars shall confirm to the relevant Indian standard specificationa IS: 12063/1987 , IS: 5082/1998 , IS:613/2000 , IS:1897/1983, IS: 6005/1998 , IS: 5/2004 IS: 732/1989 8588: Part1/1977, Rated voltage : 3 ph 11 KV 50 Hz, Current rating : 630 Amps continuous type, Insulation level :11KV AC 50 Hz, Phase to phase : 18KV AC 5 Hz (1 Min withstand ), Phase to earth : 19KV DC 4.4 Temperature rise : Shall not exceed delivery operating temperature of components conforming to relevant standards limited to 30°C above ambient.GENERAL TECHNICAL REQUIREMENTS: CUBICLE : The cubicle of HT feeder pillars shall be made out of 10 SWG (3.25 mm thick) cold rolled M.S sheet steel, plates and shaped sections. All panel edges and door edges shall be reinforced against distortion by rolling, bending etc. The complete cubical shall be rigid self supporting and free standing and shall have following dimensions in mm.:Dimensions Over all Width : 1400 MM Overall Height : 1800 MM Overall Depth : 850 MM The above dimensions shall be without rain hood and are subject to maximum of – 2%to + 2% tolerances. The HT feeder pillars shall have front and rear compartments. Front compartment shall be suitable for connecting the terminals of cables, and the rear for cable terminations. Backelite sheet 12mm thick shall be provided for separation cable termination at front side . 1 The cubicles shall have centre lift up type slanting roof rain hood made up of 10 SWG MS sheets plates. The depth and width of the rain hood shall be at least 120% of the depth and width pillars..The cubicles shall be provided with waterproof non-detachable hinged doors with suitable grip for opening and closing .as below: Two nos of doors for front and for back side along with 3 Nos of Hinges on each door The hinges shall be made up of heavy-duty M.S. rod with male having at least 45mm long head and 25 mm long 9.5 mm OD pin and female at least 45mm long with 10mm dia. ID brass bush. The hinges shall be welded on both sides to the pillar and grease lubricated for life. The doors shall not be detachable after fixing the rain hood. Cable Entry: The cable entry shall be from rear side of the pillar. Removable gland plate of 10 SWG. M.S. sheet shall be provided. Cable chamber shall be provided with perforated metal sheet separate for each chamber..Additional Inner Door: Additional door on front side, with 14 swg G.I wire, shall be provided. Also the detatchable frame with 14 swg GI wire mesh shall be provided at rear side. There shall be firm stop for these wire mesh doors and frame that it shall not move towards inside of Pillar/Live connections. BUS BAR: The bus bars shall be made up of electrolytic grade copper confirming to latest grade of IS The contacts shall be made up of electrolytic grade copper alloy with corrugated terminal pad and spring action to yield high contact pressure. G. I. spring ring shall be made out of at least 6 mm dia. Spring steel round. The spring action shall not get affected by operations and variations in operating temperatures in service.Thermostatic bimetal device shall be provided between terminal pad and bus bars and between terminal pad and cable terminals to prevent bimetallic deterioration. The complete assembly shall be so fixed and secured that there shall be no turn, fall out displacement and vibration of any part during any fault feeding conditionMaximum rated current Maximum rated current shall be 630 Amps continuous rating.
Dismantling the existing pole above 6 m height with brackets, clamps, insulators, stay from the c.c. foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level.
Dismantling the existing overhead line including G.I. wires of all sizes without damaging & making the coils in suitable sizes.
Supplying & erecting end pole D. P. Structure for 11/0.415 kV, 200 kVA Transformer with R.S.J. Pole 2 Nos. of size 100mm x 116 mm x 11 m Long with suitable Distribution Box of C.R.C.A. Sheet 16 SWG with 4 Pole MCCB 400 Amps as incomer & 6 Nos.200 Amps Kitkat / MCCB for out going circuits. Transformer D.P. Structure includes the A. B. Switch 200 Amps, D.O. fuse Set & L.A. Set. 2 Nos. Top channel of size 100 mmx 50 mm for erection of A.B. Switch & 2 Nos. Base channel of size 100 mm x 50 x mm for erecting Transformer. Channel of size 75 x40 mm for erecting D.O. Fuse Set, L.A., A.B. Switch handle etc. Angle of size 50 x 50 x6 mm for erecting Distribution Box , Transformer Belt etc.as per drawing (min. 124 Kg. iron work) with necessary clamps, Nut-bolts. V cross arm, top clip, insulators etc. complete with caution board & barbed wire. D.P. Structure shall be erected in c.c. foundation complete. [2 for new dtc for street lights + 8 for shifting of 200 kVA transforemer + 2 for 315 kVA transforemer = 12 nos]
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(UE), 3 x 300 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT
Providing and erecting Heat shrinkable outdoor termination kit for 11 kV (UE)/ 22 kV ( E ) XLPE HT cable 3x240 to 400 sq. mm. with necessary material as per specification no. CB-JT/HT
Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete
Supplying & laying (including excavation) half round reinforced cement concrete pipe of IS 458:2003 NP-2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
Supplying, erecting, testing & commissioning 11 kV, 630A, 21kA/3sec, 3 way outdoor, extensible motorised SCADA compatible RMU, internal arc tested consisting of 2 nos. feeder with 2 LBS and 1 no. feeder with 1 VCB. compliant to IEC 62271 -100, 200 and 102, as per specification no. SW-HTS/RMU SCADA
Supplying, installing, testing & commissioning of 3 phase, 11/0.433 kV, 50 Hz., 100 kVA, Mineral oil immersed and naturally cooled outdoor type, aluminium wound without gas cushioning, hermetically Sealed transformer, delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 40℃ by thermometer in oil and 45℃ by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with off load tap changer) off load +2.5 to -5 in steps of 2.5%, having 4 number of tap positions, with standard accessories complete with test certificate with losses below 475 Watts at 50% load, 1650 Watts at 100% load as per IS:1180 (part 1) : 2014 , with necessary permissions of Electrical Inspector, as per specification no SS- TR-SL [2 for proposed street lights]
Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x up to 95 sq. mm. with necessary material as per specification no. CB-JT/HT
Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x120 to 185 sq. mm. with necessary material as per specification no. CB-JT/HT
Dismantling the existing distribution transformer of any capacity from the plinth / foundation safely without any damages.[315 kVA * 2 nos]
Dismantling existing pole mounted distribution transformer safely without any damages.[200 kVA x 8 nos]
Only erecting 200 kVA Transforner as per Specification no SS- TR
Only erecting 315 kVA Transforner as per Specification no SS- TR
Supplying & erecting G.I. pipe ‘A’ class 75 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE [4 mtr *( 48+44) = 368 mtr ]
Making transformer plinth (1.5 x 1.5 x 1.5) m in size with necessary excavation in ground with 150 mm. thick M- 10 PCC at the bottom and top and 250 mm. thick, burnt brick wall constructed at periphery and remaining hollow portion shall be filled with 40mm hard broken aggregate. External surface duly plastered by 12 mm thick including watering etc complete.[10 for DTC + 22 for RMU]
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying and erecting triple pole mini feeder pillar with 500V, 300A FPMCCB as incomer and 3 outgoing circuits with HRC fuse base and cartridge of 100A with aluminium bus bar erected in 14 SWG CRCA sheet box with supporting angles, self locks, gasket having IP54,IK10 protection and slanting top to be erected on provided foundation as per specification no. SW-SWR/MFP
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 2.5 to 16 sq mm., with necessary material as per specification No. CB-JT/LT
Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 240 to 300 sq mm., with necessary material as per specification no. CB-JT/LT
Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete
Supplying & laying (including excavation) half round reinforced cement concrete pipe of IS 458:2003 NP-2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
Dismantling the existing pole above 6 m height with brackets, clamps, insulators, stay from the c.c. foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level.
Dismantling the existing overhead line including G.I. wires of all sizes without damaging & making the coils in suitable sizes.
M/s.Sudarshan Elect Engg Works