Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹39.9 LAccepted-AOC C O MANOJ KUMAR KESHRI MIRA SADAN ROAD NO 03 ANAND VIHAR NEAR WAXPOL FACTORY BOOTY MORE BUTI RANCHI JHARKHAND 834012 | RANCHI | RANCHI | JHARKHAND | 834012 | 1 | Accepted-AOC ok | |
| 2 | 2₹42.1 L+₹1.8 L (4.51%)Rejected-Finance SANDHYA NIWAS MAGADH COLONY ROAD NO 03 SHERGHATI ROAD PS MAGADH MEDICAL COLLAGE DIST GAYA PIN 823001 BIHAR | GAYA | BIHAR | 823001 | 2 | Rejected-Finance Quoted Rate more than L1 |
Tender Value
Refer Docs
EMD Value
₹92,000
Closing Date
13 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Dipatoli
GARRISON ENGINEER MILITARY ENGINEER SERVICES DIPATOLI CANTT PO- HOTWAR RANCHI Pin- 834012
PROVN OF VARIOUS MINOR WORK, REVENUE WORK AND SPL REPAIR WORK UNDER GE DIPATOLI
2024_MES_637366_1
8000/1955/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Dipatoli
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Dipatoli
₹92,000
Yes
15 Mar 2024
13 Jan 2024
15 Feb 2024
13 Jan 2024
13 Feb 2024
27 Jan 2024
Amount
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in hard/ dense soil, complete all as specified and directed.
Excavation in trenches n. exc 1.5m wide & n. exc 1.5m deep for foundation,etc and getting out in soft/loose soil, complete all as specified and directed.
M&L hard core of gauge n'exc 63 mm of broken stone or boulders deposited spread and leveled in layers n . exc 15cm thick, watered and rammed to a true surface, complete all as specified and directed.
M&L brick work with fly ash bricks, straight or curved on plan exc 6m mean radius, old size bricks built in CM 1:6, complete all as specified and directed.
Material and labour for rendering 15mm thick cement plaster in cement mortar 1:4 on stone masonry surfaces other than fair face, finished even and fair wthout using extra cement complete all as specified and as directed.
M&L for preparation of newly plastered or conc wall surface and applying two coats of white wash, complete all as specified and directed.
M&L PCC (1:4:8) type D-2 using 40mm graded stone agg as in fdn filling mass concrete, complete all as specified and directed.
M/L for 100mm thick cement concrete1:2:4 type B2,using 40 mm stone aggregate with fair finish complete all as specified, complete all as specified and directed.
M/L for 40mm thick cement concrete1:2:4 type B0,using 12.5 mm stone aggregate with smooth finish complete all as specified, complete all as specified and directed.
Cement concrete 1:3:6 type E2 (using 40 mm graded stone aggregate) as in walls, pillars and posts, etc including caps and bases with smooth finish without using extra cement including necessary formwork complete all as spd and directed.
M&L PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) 75mm thick as in plinth protection /path etc finished cement concrete surface even and smooth without using extra cement, complete all as specified and directed.
S & F plates plain or chequired with sleeve pieces riveted or welded thereto, Fe 410-W (gde E-250) quality B complee all as specfied and directed.
S & F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240, complete all as specified and directed.
Supply and fixing for pre-painted galvalume aluminium zinc coating GI based corrosion protection and heat reflective corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F 10mm dia and over TMT bars,cut to length bent to shape etc as required incl binding with MS wire annealed not less than 0.90m dia, complete all as specified and directed.
S&F 5mm dia and over upto 10mm dia and incluing 10mm dia stirrups TMT bars,cut to length bent to shape etc as required incl binding with MS wire annealed not less than 0.90m dia as in stirrups, spacers and biding completed all as spd and directed.
M&L for fair finished form work sides and soffits of Lintel beams, lintel bends roof beam shelves, cooking platforms or other similar work etc completed all as spd and directed.
Form work to edges of concrete flats, treads, opening in concrete walls, floor and roofs n.exc 20cm wide and sides of RCC/PCC bands in walls etc for fair finished complete all as specified and directed.
M&L Reinforced cement concrete in mix 1:1½:3 (nominal mix) using 20mm graded aggregates) as in lintel beams, chajja, shelves etc, complete all as specified and directed.
S&F framed work as in door or gates of angle or other section with gusset plates rails, braces etc. Complete ,drilled for fixing of steel sheeting or other covering .Door etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering )and hanging ,also fastening and fixing , complete all as specified and directed.
S&F 0.80mm thick mild steel plain black sheet in steel gates and similar works cut to size,holes,punched including round heade screws,clout nails or revets and fixed to steel framing with plain 40mm lap joints with reveted or welded seams ,including bending or turning up etc.complete.
S&F MS 250mm long sliding door bolt plate type stove enamelled black with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts four on bolt plate and two staple plate, complete all as specified and directed.
S&F steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and directed.
S & F Sheet glass, figured glaas ,pin headed in square n exc 0.5 sqm in each pane, 3mm thick, complete all as specified and directed.
Supply and fix mild steel frame & work such as grills gratings etc, with ends of bars shouldered and or riveted or forged into spikes, framed guard bars, and similar work confirming to Fe 290 Gde E-165 complate all as spd and directed.
M&L for two coats of synthetic enamel paint over one coat of red oxide primer on steel surfaces of any description over 10cm width or grith incl preparation of new surface, complete all as specified and directed.
Returning/filling in layer n'exc 25 cm thick including spreading, levelling watering well ramming etc, complete all as specified and directed.
Removing excavated soil to distance n'exc 50 mtr and deposited complete all as specified and directed.
Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed.
Exavation over area not exc1.5mtr deep and getting out in soft/loose soil completed as all specified and directed.
M&L Reinforced cement concrete in mix (1:1.5:3) (using 20mm graded aggregates) in foundations, including rafts, footings, plinth beams etc complete all as specified and directed.
All as per item No 31 above but in Columns, pillars, complete all as specified and directed.
All as per item No 31 above but in chajjas, complete all as specified and directed.
All as per item No 31 above but in beams and lintel, complete all as specified and directed.
All as per item No 31 above but in floor/roof slab, complete all as specified and directed.
M&L formwork to sides of concrete foundations, footings, bases of columns, rafts and raft beams, sides and soffits of foundation and plinth beam, and similar work, vertical or batter work fair finished flat surface of concrete complete all as specified and directed.
All as per item No 36 but in columns/post, complete all as specified and directed.
M&L 15mm thick plastering on wall concrete surfaces in cm (1:6) finished even and smooth w/o using extra cement, complete all as specified and directed.
M&L cement concrete as in plinth type C-1,1:3:6 using 20mm graded stone aggregate, complete all as specified and directed.
M&L Cement concrete in floors 40mm thick over sub base (1:2:4) using 20mm graded aggregate finished even and smooth without using extra cement, complete all as specified and directed.
M & L for rendering 10 mm thick in cement Mortar (1:4) on the surfaces of ceiliing and finished the surface fair and even complete as specified and directed
M/L preparation of newly plastered surfaces of wall/ ceiling and applying a coat of wall care putty 1 mm thick to make the surfaces truly smooth , complete all as specified and directed.
M&L hard core of gauge n'exc 63 mm of broken stone or boulders deposited spread and leveled in layers n . exc 15cm thick, watered and rammed to a true surface, complete all as specified and directed.
M&L for applying two coats of oil bound distemper over one coat of chalk whiting on plastered surfaces of wall, preparatory to distempering including preparation of newly plastered surface complete all as specified and directed.
M&L for applying two coats of oil bound distemper over one coat of primer on plastered surfaces of ceiling, preparatory to distempering including preparation of newly plastered surface complete all as specified and directed.
M&L preparing new surface on walls and applying 2 coats of cement based paint over one coat of primer on external walls, complete all as specified and directed.
S&F 10mm dia and over deformed/TMT treinforcement,cut to length bent to shape etc as required incl binding with MS wire annealed not less than 0.90m dia, complete all as specified and directed.
All as per item No 47 here-in-before but 6 to 8 mm dia, complete all as specified and directed.
All as per item No 47 above but 8mm dia as in stirrups, complete all as specified and directed.
M&L for coloured glazed ceramic tiles in vertical surface 350x 250x 7 mm / 450X 350X 7mm thick including over10 mm thick cement plaster in CM (1:4); set and jointed in neat cement slurry & pointed in white or coloured cement to match the surfaces all as specified and directed.
M&L non skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tiles exceeding 0.11 sqm but n.exc 0.20 sqm as in floor etc, with and including over 15 mm thick screed bed in CM(1:6), set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces complete all as specified and as directed.
S & F mild steel butt hinges 100mm long medium weight cold rolled , complete all as specified and directed.
S&F Aluminium anodised barrel tower bolt of extruded section and fixed of 150mm size, complete all as specified and directed.
S&F 125mm size aluminium handles, cast type anodised, complete all as specified and directed.
S & F 15mm dia stop valve CP fancy type long body screwed to unioun or GI pipe etc, complete all as specified and directed.
S & F GI water tubes medium grade 15mm bore with fittings laid in floors/wals complete all as specified and directed.
All as per item No 34 above but 20mm bore, complete all as specified and directed.
S&F Vitreous china white wash down water closet (Pedestal pattern) wall hung including connection to drain ( or outgoing pipe) and to flushing pipe, antisyphonage pipe etc incl P or S trap, complete all as specified and directed.
S&F bib taps fancy type cast copper alloy chormium plated 15mm bore with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and directed.
S&F pillar taps fancy type cast copper alloy chormium plated 15mm bore with crutch , screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and directed.
S&F in chromium plated jet spray / health faucet, complete all as specified and directed.
S&F chromium plated toilet paper holder size 150 x150mm complete all as specified and directed.
S&F vitreous china wash basin,(pedestal type) white flat back size 550x400mm (excluding taps, incl.CP waste coupling & PVC waste pipe and brackets, complete all as specified and directed.
Cutting chases in brickwall pinning in making good to facings where required and pointing in cement mortar 1:3 to ends and cutting chases for concealed water tubing and making good cutting n.exc. 10 cm girth, complete all as specified and directed.
S&F Angle valve two way, cast copper alloy fancy type chromium plated screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed of size 15mm bore with fancy design (half turn type), complete all as specified and directed.
S&F in soap Dish vitreous china Approx size 160x 160x90mm complete all as specified and directed.
S&F 500 ltr capacity Rotational moulded polyethylene water storage tank (cylindrical vertical closed top) hoisted and fixed in positions all as specified in SSR Part-I,including 20 mm dia of ball valves high pressure of PTMT with epoxy coated aluminium rod &highdensity plastic ball screwed for iron pipe and fixed, complete all as specified and directed.
S&F PVC Connections 15mm size and 450mm length, complete all as specified and directed.
S&F angle valve / stop valve , cast copper alloy fancy type chromium plated with long shank and cup screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed of size 15mm bore, complete all as specified and directed.
S&F in Brass chromium plated tubular towel rail 20mm dia,D type, 60 cm long between flanges, complete all as specified and directed.
S&F 110mm PVC (SWR) branch pieces, single equal or unequall, complete all as specified and directed.
S&F 110mm PVC (SWR) Bends any radius, complete all as specified and directed.
S&F110mm PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed.
Use and waist form work to soffits of suspended slabs such as roof slabs, floor slabs n.exc.200mm thick in rough finished surfaces etc, complete all as specified and directed.
M&L for rendering 15 mm thick in CM 1:4 on any faces brick work including finishing the surface fair and smooth without using extra cement with mixing of water proofing compound complete all as specified and directed.( WPC measured and paid separately), complete all as specified and directed.
M&L for rendering 10 mm thick in CM 1:3 on any faces of concrete surface including finishing the surface fair and smooth without using extra cement with mixing of water proofing compound complete all as specified and directed.( WPC measured and paid separately), complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in foundation bed of manhole, mass concrete etc complete all as specified and directed.
Supply only integral water proofing compound, complete all as specified and directed.
S & F Powder coated aluminium ventilator louvre type with frame, aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, side handles fixed to wall with fastener etc, complete all as specified and as directed.
S&F 32mm waste fittings brass chromimum plated for basin with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed, complete all as specified and directed.
S&F stop valves, 20mm bore dia of pipe cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for union and fixed, complete all as specified and directed.
M & L salt glazed stoneware drain pipes 300 mm dia laid in trenches and joined as specified, complete all as specified and directed.
Surface excavation n.exc. 30cm deep and averaging 15cm deep and getting out in soft/ loose soil complete all as specified and directed.
Excavation in trenches not exc. 1.5 metre wide and not exc. 1.50 metre in depth for foundation etc and for manholes etc n.exc. 10 Sqm on plan and n.exc. 1.5 metre depth and getting out in soft/loose soil complete all as specified and directed.
Removing excavated materials (soils) to a distance not exc. 50 metre and depositing where directed at a level not exc. 1.50 above the starting point complete all as specified and directed.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick as in soft/loose soil complete all as specified and directed.
Treating the top surface of filled earth at the rate of 7.50 litres of emulsion per square metre of surface complete all as specified and directed.
Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the substructure in contact with backfill to be measured) complete all as specified and directed.
Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
Material & labour for approved soil filling under the floor, spreading and levelling in layers n.exc. 25cm thick, well ramming including watering as required complete all as specified and directed.
Material & labour for hardcore of broken bricks gauges n.exc. 63mm, deposited spread and leveled in layers n.exc. 15 cm thick watered and rammed to a true surface complete all as specified and directed.
Material & labour for cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete and sub base of floor complete all as specified and directed.
Use and waste of Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed.
Use and waste of Form work of sides of pillars, posts, struts, piers, columns etc square or rectangular or polygonal rough surfaces of concrete complete all as specified and directed.
M&L Form work to sides and soffits of beams lintels etc finished rough complete all as specified and directed.
Use and waste of Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick flat fair finished surfaces of concrete complete all as specified and directed.
M&Lfor form work to the edge of concrete flat n. exc 200 mm thick complete all as specified and directed. .
Supply & fix mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Supply & fix mild steel TMT bars 6 to 8 mm dia and over, cut to length, bent to shape required as in stirrups complete all as specified and directed.
M&L RCC 1:2:4 Tybe B1 using 20 mm graded stone aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under reamed piles and mass concrete complete all as specified and directed.
M & L RCC 1:2:4 Type B1 using 20 mm graded stone aggregate as in Columns, pillars etc complete all as specified and directed.
M & L RCC 1:2:4 Type B1 using 20 mm graded stone aggregate as in beams, lintels over 1.5 m span etc complete all as specified and directed.
M&L for RCC M 25 type A-1 using 20 mm graded stone aggregate for roof slabs supported on walls, beams and the like complete all as specified and directed.
Material & labour for 15 mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces, surfaces finished even and smooth without using extra cement complete all as specified and directed.
Material & labour for 15 mm thick rendering on other than fair faces of brick work or concrete surfaces,in CM(1:4) surface finished even and smooth without using extra cement complete all as specified and directed.
Material & labour for 5 mm thick plaster in CM 1:3 on ceiling surfaces, surfaces finished even and smooth without using extra cement complete all as specified and directed.
M/L 75 mm thick cement concrete 1:3:6 type C-2 using (40 mm graded stone agg) as in sub base complete all as specified and directed.
M&L Non Skid ceramic tiles 7-8 mm thick (squares/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, (600 x 600) in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement joint free non skid tiles.to match 15mm thick screed bed in CM 1:6 complete all as specified and directed
M&L Non Skid ceramic tiles 7-8 mm thick (squares/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in vertical surfaces etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match 15mm thick rendering1:6 complete all as specified and directed
M&L 50mm thick PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in path /plinth protection , finish even & smooth without using extra cement all as specified and directed.
Material & labour for preparation of new plastered surfaces of walls etc and applying two coats of cement base paint over a coat of primer complete all as specified & directed.
Material & labour for preparation of new plastered surfaces of walls with wall care putty and applying two coats of Oil bound distemper to match the existing surfaces as required, complete all as specified & directed.
Material and labour for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified & directed.
Material & Labour for 40mm thick average thickness of PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) as in padding on roof finished even and fair without using extra cement all as specified and directed.
M&L for applying a coat of bitumen primer @ 0.3L/sqm on roof surfaces, complete all as specified and directed.
M&L for applying 3mm thick APP modified polymeric membrane over the bitumen coat surface weight not less than 3kg/sqm and over lap 100mm and sealed by torch application as per manufacture insteructions complte all as specified and directed
Supply and fix 30 mm thick flush shutter solid core construction with particle board and plywood face panels commercial type on both side complete all as spfd and directed
Supply & fixing pressed steel frames for doors with one or more rebates including necessary fixing lugs lugs, hinges, lock strike plates etc completed size of frame 125x60mm made out of 1.25mm MS sheets complete all as specified & directed.
S &F Flat iron hold fast 25mm x 6mm welded to angle iron door frame as directed.
Supply & fix 125mm size aluminium alloy handles cast type anodized complete all as specified & directed.
Supply & fix Aluminium. Sliding door bolts, plate type, complete, 250mm long complete all as specified and directed.
M&L preparation of new or previously untreated wooden surfaces of any description, not other wise described over 10cm width or girth and apply two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L preparation of new or previously untreated steel surface of any description over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M & L Steel window box type using ERW 'P' section comprising double frame for gauged and glazed skeleton shutter jointed internally with flat iron 40x3mm complete including hinges, handle tower bolts stops, lugs etc all as shown on drawing Note (i) For the purpose of measurement & payment double shutter with frame shall be considered as one unit (ii) Unit rate quoted against this item shall also include the iron mangeryas shown on drgs (iii) Guard bars glazing & wire mesh shall be measured & paid for separately complete all as specified and directed. .
Supply & fix mild steel work as in hold fast etc and similar articles confirming Fe-310-0 with & including material & labour tarring & sanding complete all as specified & directed.
Supply & fix mild steel framed work such as grills, gratings guard bar etc with ends of bars shouldered and/ or riveted etc , complete all as specified and directed.
Demolition of RCC in floors (other than ground floors beams,chajjas,lending slab and similar suspended works all as specified and directed.
Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed.
M&L 20 mm thick granite of any type with rubbed and polished in steps, jambs, cills, cooking plat form etc with CM 1:4 over 15mm thk screedbed including pointing in white cement 1:2 using marble dust with admixtre of pigment to match with true surfaces, complete all as specified and directed.
Rounding to edges of stone slabs on edge such as in steps cooking platform and other similar situations, complete all as specified and directed.
M&L Non- skid colour ceramic tiles,7 to 8mm thick square / rectangular area of each tile exc 0.11 sqm but n exc 0.18sqm in floor over and including 15mm thick screed bed in CM (1:6), set and jointed in neat cement slurry and pointed in white or coloured cement to match the floor , complete all as specified and directed.
ditto- item 5 but in skirting including 10mm thick screed bed in CM(1:4) completed all as specified and directed, complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc, complete all as specified and directed.
M&L rendering 15 mm thick in cement mortar 1:4 on wall of brick work or concrete surface, finished fair and even all as specified and directed.
M&L rendering 15 mm thick in cement mortar 1:6 on wall of brick work or concrete surface, finished fair and even all as specified and directed.
M&L rendering 5 mm thick in cement mortar 1:3 on ceiling of brick or concrete surface, finished fair and even all as specified and directed.
M&L for preparing the new plastered surfaces of wall and applying Two coat of cement based paint after one coat of white primer all as specified .
M&L for preparing the old surfaces by complete removel of existing treatment and applying two coats of cement bsed paint on walls complete all as specified .
M&L for complete removal of existing treatment or preparation of newly plastered wall surfaces, chajja, facia etc and applying two coat weather proof exterior emulsion paint(1st quality)/plastic emulsion paint on walls, chajjas,facia by mechanical applicator of any height of bldigs etc , including primer complete all as specified and as directed .(Weather coat shall be of Asian paint, Apex ,ultima or equivalent as approved by GE)
M&L for preparing new plastered surfaces and applying two coats of distember oil emulsion white or tinted after one coat of white primer complete all as specified and directed.
M&L for preparing of old surfaces, washing, rubbing down and stopping of disstempered and painted surfaces and applying two coats of distember oil emulsion on wall complete all as specified and directed.
M&L for preparation of new surfaces and applying Three coat of white wash on wall including cornices etc complete all as specified and directed.
M&L for preparation of old surfaces and applying one coat of white wash on wall including cornices etc complete all as specified and directed.
M&L for preparation of new surfaces and applying three coat of white wash on ceiling including cornices etc complete all as specified and directed.
M&L for preparation of old ceiling surfaces and applying two coat of white wash complete all as specified and directed.
M&L for 3mm thick wall care putty on wall and rubbing smooth surface as directed.
Demolition of brick work or rubbled stone masonry including all qoins arches , pillars etc built in cement mortar, complete all as specified and directed.
S&F powder coated Aluminium three track sliding glazed window manufactured with approved aluminium section with three sliding shutters each shutter width one half of the length of window with the following specifiecation and making good the adjascent surfaces :- (a) Window frame of cross section 101mmx40mmx1.5mm thick. (b) Three way track for smooth slding shutters of cross sections 91.80mmx31.75mmx1.1mm thick. (c) Sliding shutter frame of cross section 40x18x1mm. (d) Aluminium glazing stip of size 18.2x16.66mm. (e) 4mm thick flat glass superior quality for two shutter. (f) IDPE rubber gasket for fixing glass. (g) Locking cleat/device as shutter 01 Nos. (h) 02 Nos sliding roller per shutters. (j) aluminium wire cloth 0.36mm stainless steel nominal dia of wire and average width of aperature 1.40mm for one shutter. (k) Fixing screws for frame with wall 06 per window with fancy design. (Note: Window will be measured outer to outer frame and no extra to be paid.), complete all as specified and directed.
S&F Powder coated aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weeighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fitings such as peg stays 150mm long (1 no.) hinge type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed.
S&F powder coated anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed.
Supply and fix powder coated approved anodised aluminium window and ventilator shutter, side hung type without sash bars, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clip, rubber packing, anodised aluminium snap beading, screws, etc complete all as specified
Taking down chowkats or frames with shutters (without taking off shutter from frames) not exc. 1.5 sq. m each, complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutter from frames) exc. 1.5 & n exc 4 sq. m each, complete all as specified and directed.
Taking down shutters of any description exc 1 but n exc 2 sq. m each, complete all as specified and directed.
S&F 2nd class hardwood, plain, solid, straight chowkats and frames, wrought, framed rebated on the solid rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed.
M&L Glazed and skeleton shutters 35 mm thick open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chemfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.20 (a); for doors supplied and fitted to chowkats complete all as specified and directed.
S&F Plain framed, panelled shutter (two panel) factory made 35 mm thick of 2nd class HW rail and stylewith lock rail and panel of 9mm B.W.P. commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS: 1003 (Part-I), Kiln seasoned and chemically pressure treated,. complete all as specified and directed.
S&F Solid PVC Door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined to gether with solvent cement, suppling & fixing in the frame as per specification & drawing complete all as specified and directed.
S&F 3mm thick Figured glass, pin headed type and glazing with oil putty in square n exc 0.5 sqm in each pane, complete all as specified and directed.
S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average with of aperture 1.18mm and fixed with tinned tack, or galvanised wire staples , complete all as specified and directed.
S&F SS Butt hinges medium weight 100mm size,cold rolled mild steel, complete all as specified and directed.
S&F Ordinary rat tail rod pattern, 300mm spring incl roller and roller plate , complete all as specified and directed.
Taking down GI tubing and connection including removing to store of 15mm dia complete aall as secified and directed.
Taking down GI tubing and connection including removing to store of 20mm dia complete aall as secified and directed.
Supplied and fixed GI tubing 15 mm bore medium grade with all fittings fixed to walls and ceilings or laid in floors all as specified and directed.
fixing only GI tubing 15 mm bore medium grade with all fittings fixed to walls and ceilings or laid in floors all as specified and directed.
Supplied and fixed GI tubing 20 mm bore medium grade with all fittings fixed to walls and ceilings or laid in floors all as specified and directed.
fixing only GI tubing 20 mm bore medium grade with all fittings fixed to walls and ceilings or laid in floors all as specified and directed.
S&F in repair Gun-metal, globe or gate valves 15mm dia with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and directed.
S&F in repair Gun-metal, globe or gate valves 20mm dia with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and directed.
Dismantling water tanks and removing exc 250 & nexc 500 ltrs capecity complete all as specified and as directed.
S&F PVC rotational moulded polythylene water storage tanks 500 litres capacity incl cover etc complete all as specified and as directed.
Disconnecting exisiting tanks setting aside for repairng cleaning and removing al scale and dirt etc from mounths of circulating pipes etc and including refixing in existing position with all fittings, capacity of tanks exc 250 ltrs and not exc 500 ltrs complete all as specified and as directed.
S&F in repair 15mm dia bore, stop valve (concealed type), cast copper alloy fancy type chromium plated screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in pipe and all as specified and directed.
S&F in repair 15mm, stop valve/angle valve, cast copper alloy fancy type chromium plasted with long shank and cup screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed of size 15mm bore with fancy design and all as specified and directed.
S&F in repairs bib taps fancy type, cast copper alloy chromium plated 15mm bore with crutch or butterfly handle, screwed down screwed for iron pipe or for brass ferrule and all as specified and directed.
Supplied and fixed in repair 125 mm size brass chormium plated shower rose including fixing to steel pipe or union complete all as specified.
Supply and fix in repair, sinks with drainage board made of stainless steel 1 mm thick sheet for, kitchen or laboratory with plugs, washers and waste pipe; cast iron cantilever brackets and connecting union to pipe overall size 915 mm x 460 mm bowl size 410 mm x 330 mm x 160 mm complete all as specified and as directed.
fix in repairs only sinks with drainage board made of stainless steel 1 mm thick sheet for, kitchen or laboratory with plugs, washers and waste pipe; including beading in cement mortar on to wall or including fixing cantilever brackets and connectin union to waste pipe etc, complete all as specified and as directed.
S/F Chromium plated tubular towel rail, 20mm dia, D type 60 cm long between flanges, complete all as specified and directed.
S&F in repairs decorative curtain rod made out of 25mm dia (outer dia) MS pipe having wall thickness 0.63mm, PVC coated of any colour and pattern as approved overall dia 28 to 28mm, includiing and including two nos brackets on each ends alongwith globe on each ends for earch window/door fro fixing , complete all as specified and directed..
S&F in repairs PVC valveless syphonic action fancy type low level flushing cistern 10 ltr. Capacity of approved incl flush pipe of 32mm bore and all as specified and directed.
Fix in repairs only PVC valveless syphonic action fancy type low level flushing cistern 10 ltr. Capacity of approved inc S&Fix flush pipe of 32mm bore and all as specified and directed.
Supply and fixing in repair vitreous china squatting pan 'Orrisa pattern' size 580x440mm white with integral foot rests any pattern including provn of lime concrete bedding and making connection with & including PVC P Trap, etc complete all as specified and directed.
Fix in repair only vitreous china squatting pan 'Orrisa pattern' size 580x440mm white with integral foot rests any pattern including provn of lime concrete bedding and making connection with PVC P Trap, etc complete all as specified and directed.
Supplied and fixed in repair vitreous china WHB white flat back size 550x400mm including Supplied and fixed angle iron brackets, C.P pillar tap fency type 01 No 15mm bore, CP waste coupling, 32mm dia and PVC waste pipe 32mm dia and PVC connection 450mm long high pressure complete all as specified & directed.
Taking down eaves gutters and rain water pipes (any ize or patterns) including all heads,shoes,bends,swan-necks etc, complete all as specified and directed.
S&F PVC(SWR) floor trap 75mm dia plain with grating incl jointing with solvent cement, complete all as specified and directed.
S&F PVC(SWR) multi floor trap/nahani trap 75mm dia plain with grating incl jointing with solvent cement, complete all as specified and directed.
S&F PVC(SWR) pipe 110 mm dia single socketed in any length with rubber ring joints, laid in trenches or in floors , complete all as specified and directed.
M&L PVC (SWR) bend of radius 110mm dia, complete all as specified and directed.
M&L PVC(SWR) Tee of radius 110mm dia, complete all as specified and directed.
M&L PVC (SWR) vent cowl 110mm dia, complete all as specified and directed.
M&L PVC(SWR) pipes 75mm dia single socketed, in any length with rubber ring joints,laid in trenches or fixed to wall with and including stack and clamp, complete all as specified and directed.
M&L PVC (SWR) bend of radius 75mm dia, complete all as specified and directed.
M&L PVC (SWR) Tee of radius 75mm dia , complete all as specified and directed.
Demolition of cement concrete in ground floors and paving exc 15cm thickness(below or above ground level) all as specified and directed.
M&L Cement concrete 1:5:10 type E-2 (using 40 mm graded aggregate as in filling around shunken areas complete all as specified and directed.
M&L for 40 mm thick PCC (1:2:4) type B-1 using 20 mm graded stone aggregate with WPC as in sunken portion and making adequate slope toward spout pipe complete all as specified and as directed. NOTE: - Water Proofing Compound shall be measured and paid separately
M&L for rendering 15 mm thick on concrete or brick surface in CM (1:3) mixed with WPC as per manufacturer instructions and finishes surfaces even and smooth with out using extra cement, complete all as specified and directed.Note - WPC will be measured and paid separtely
M&L for applying two coats evenly a tack coat of hot air blown bitumen of grade 85/25 @ 1.50 Kg per sqm per coat (one coat over plaster and one coat on polythene film) including cleaning of surface over polythene film complete all as specified and as directed
M&L for polythene film black 200 micron thick laid in floor, vertical surface etc complete all as specified and directed.
Complete removal of all existing roof treatment from RCC roof including old hussion felt, tiles etc and preparation of surface with bire brush and cleaning with water complete all as specified and directed.
M&L for 40 mm thick PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate to roof , floor, chajja, RCC shelves etc at water retaning surfaces with WPC and make proper good slope as directed. (Note-wpc will be measured and paid seprately)
M&L for preparation of concrete roof surfaces and applying 10mm thick plaster in CM 1:4 and finished the surface even and smooth without using extra cement complete all as specified and directed.
M&L for applying a coat of bitumen primer @ 0.3L/sqm on roof surfaces, complete all as specified and directed.
M&L for applying 3mm thick APP modified polymeric membrane over the bitumen coat surface weight not less than 3kg/sqm and over lap 100mm and sealed by torch application as per manufacture insteructions complte all as specified and directed
M&L for applying two coats aluminium paint over bituminous surface of membrane, complete all as specified and directed.
M/L PCC 1:2:4 type B1 20mm grade aggregate as in padding, hold fasts/filling of chowkhats or similar work complete all as specified and as directed.
Supply only liquid water proofing compound, complete all as specified and directed.
M/L for preparing the old steel surface of any description not otherwise described over 10 cm width or girth and applying one coats of synthetic enamel paint all as specified and directed.
M&L for preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specified.
Demolition of old UNSV RCC tank of 1000 ltr capacity in any position and in any condition from the roof and removing all demolished material from the side 50 km from ground floors beams,chajjas,lending slab and similar suspended works all as specified and directed.
M&L for applying two coats of synthetic enameled paint on old painted wooden surfaces of any description not otherwise described over 10cm width or girth including preparation of surface all as specified and directed.
M&L point wiring for One light/Fan point controlled by one five amps one way single pole switch complete with 1.5 sqmm , single core , multi stranded copper conductor PVC insulated and unsheathed FRLS cable 1100 Volts grade , drawn through PVC concealed conduit 20/25 mm dia on wall/ceiling ,including replacement by new 3 mm thick phenolic laminated sheet top covers and sunk type CI/steel terminal boxes ,cromium plate screw as suitable size for mounting of switch & scoket including 1.5 sqmm size pvc insulated unsheathed copper conductor to common earth and connecting to earth dolly complete all as specified and directed. Note: The rate quoted is deemed to be included for Penolic sheet (Hylem) and steel terminal box , cutting of hylem sheet for fixing of switch and scoket including cutting chases in wall making good to disturbed surface and matching with existing surfaces , complete all as specified and directed.
All as per Ser item No 218here-in-before but one 3 Pin Socket out let 5 Amps on the same board, complete all as specified and directed.
All as per Ser item No 218 here-in-before but one 3 Pin Socket out let 5 Amps on the independent board, complete all as specified and directed.
All as per Ser item No 218 here-in-before but point wiring with 2.5 sqmm for 15 Amp socket out let & provision of earth wire 2.5 sqmm connected to common eart dolly.
Supply and fix Switch Piano type, single pole, one way 5 Amp complete all as specified & directed.
S&F Switch piano type , single pole , one way 15 Amps complete all as specified and directed.
S&F Socket out let 2-in-1 2/3 pin 5 Amps complete all as specified and directed.
S&F Socket outlet 2-in-1, 3 pin ,5 and 15 amps , flush type complete all as specified & directed.
S&F Ceiling rose, 3 terminal PVC/polycarbonate complete all as specified and directed.
M&L for submain complete with 2x1.5 sqmm, single core, multi stranded copper conductor , PVC insulated and unsheathed FRLS cable 1100 Volts grade, drawn in with and including PVC concealed conduit 20/25 mm dia as per site requirement along walls/ceiling etc including 1.5 sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly complete all as specified and as directed. Note:- (i) all three wire(Phase red colour,neutral black colour and earth wire green colour) should be run through for each individual circuit from the DBs (ii) painting over surface conduit to be done to match with walls/ceiling existing surfaces. (iii) Two run of wire (phase & neutral) and one run of wire (earth conductor) be measured as one length)
All as per ser item No-227 here-in-before but 2X4 Sqmm and 1X 4.0 Sqmm for Earth wire
Supply and fix MCB DB SPN 8 way double door with metal door suitable for housing of MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed .
S&F in replacement of MCB SP 6 to 32 Amps 'C' Series 10 KA fixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed.
S&F in replacement of MCB DP 40 Amps 'C' Series 10 KA fixing in DBs, connecting with bottel type copper thimbles, complete all as specified and directed.
S&F in replacement of LED tube light fitting 20 watt 230 Volt decorative ultra slim linear LED Lighting with aluminium housing & integrated electronic driver , including all internally pre-wired and inncluding connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
S&F in replacement of building LED security light fitting 40 Watt in aluminium pressure die cast aluminium housing with high power LED as lightning sourse and lens embedded PC Cover having IP 65 protection and impect resistance of IK07 with 10 KV Built in super protection device. luminaire with high power LED as light source including suitable size of GI bracket fixed with two Nos GI clamp nut,bolt,washer etc complete all as specified and directed.
Supply, Laying on replacement ,connecting, testing and commissioning of XLPE LT UG cable of size 10 sqmm 2 core PVC insulated and sheathed armoured heavy duty cable 1100 V grade with alu conductor cable all as directed.
Excavation in trenches in loose/soft soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying of cables, poles/stays and struts etc and getting out including trimming sides and forming bottom surface , complete all as specified and directed.
Removing excavated surplus (soil) obtained from excavation to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point, complete all as specified and directed.
Returning & filling in including spearing, leveling watering and well ramming in layers not exc 25cm thick, complete all as specified and directed.
Supply and Spread dry river sand for cable cushioning in trenches all as specified and directed.Note : Punned down thickness shall be considered for measurement , complete all as specified and directed.
Supply and lay burnt bricks sub class ‘B’ old size laid dry in trenches across the cable protection all as specified and as directed
M &L Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed .Note :- i) Earthing test must be carried out in presence of Engr-in-Charge. ii) The earthing result not more than 2 Ohms or disered earth resistance value. iii) Megger required for testing will be be provided at site by the contractor. iv) Contractor shall submit earth resistance testing report before submission of bill.
M&L point wiring for One light/Fan point controlled by one five amps one way single pole switch complete with 1.5 sqmm , single core , multi stranded copper conductor PVC insulated and unsheathed FRLS cable 1100 Volts grade , drawn through PVC conealed conduit 20/25 mm dia on wall/ceiling ,including replacement by new 3 mm thick phenolic laminated sheet top covers and sunk type CI/steel terminal boxes ,cromium plate screw as suitable size for mounting of switch & scoket including 1.5 sqmm size pvc insulated unsheathed copper conductor to common earth and connecting to earth dolly complete all as specified and directed. Note: The rate quoted is deemed to be included for Penolic sheet (Hylem) and steel terminal box , cutting of hylem sheet for fixing of switch and scoket including cutting chases in wall making good to disturbed surface and matching with existing surfaces.
All as per Ser item No 241 here-in-before but one 3 Pin Socket out let 5 Amps on the same board.
All as per Ser item No 241 here-in-before but one 3 Pin Socket out let 5 Amps on the independent board.
All as per Ser item No 241 here-in-before but point wiring with 2.5 sqmm for 15 Amp socket out let & provision of earth wire 2.5 sqmm connected to common eart dolly.
Supply and fix Switch Piano type, single pole, one way 5 Amp complete all as specified & directed.
S&F Switch piano type , single pole , one way 15 Amps complete all as specified and directed.
S&F Socket outlet 2-in-1, 2/3 pin 5 Amps complete all as specified & directed.
S&F Socket outlet 2-in-1, 3 pin ,5 and 15 amps , flush type complete all as specified & directed.
S&F Ceiling rose, 3 terminal PVC/polycarbonate complete all as specified and directed.
M&L for submain complete with 2x2.5 sqmm, single core, multi stranded copper conductor FR PVC insulated and unsheathed FRLS cable 1100 Volts grade, drawn in with and including PVC casing / caping 20/25 mm dia as per site requirement along walls/ceiling etc including 2.5 sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly complete all as specified and as directed. Note:- (i) all three wire (Phase red colour, neutral black colour and earth wire green colour) should be run through for each individual circuit from the DBs (ii) painting over surface conduit to be done to match with walls/ceiling existing surfaces. (iii) Two run of wire (phase & neutral) and one run of wire (earth conductor) be measured as one length)
All as per ser item No250 here-in-before but 2X 4 Sqmm and 1X 4.0 Sqmm for Earth wire
Supply and fix MCB DB SPN 8 way double door with metal door suitable for housing of MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed.
S&F MCB SP 6 to 32 Amps 'C' Series 10 KA fixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed.
S&F MCB DP 40 Amps 'C' Series 10 KA fixing in DBs, connecting with bottel type copper thimbles, complete all as specified and directed.
S&F LED tube light fitting 20 watt 230 Volt decorative ultra slim linear LED Lighting with PVC housing & integrated electronic driver, including all internally pre-wired and inncluding connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed.
S&F PVC ventilating air fan single phase 300 mm sweep complete with louver shutter and including making of hole suitable size fan base after cutting of brick/stone wall /suitable size of water proof ply wood complete all as specified and directed.
M&L point wiring for One light/Fan point controlled by one five amps one way single pole switch complete with 1.5 sqmm , single core , multi stranded copper conductor PVC insulated and unsheathed FRLS cable 1100 Volts grade , drawn through PVC concealed conduit 20/25 mm dia on wall/ceiling ,including replacement by new 3 mm thick phenolic laminated sheet top covers and sunk type CI/steel terminal boxes ,cromium plate screw as suitable size for mounting of switch & scoket including 1.5 sqmm size pvc insulated unsheathed copper conductor to common earth and connecting to earth dolly complete all as specified and directed. Note: The rate quoted is deemed to be included for Penolic sheet (Hylem) and steel terminal box , cutting of hylem sheet for fixing of switch and scoket including cutting chases in wall making good to disturbed surface and matching with existing surfaces, complete all as specified and directed.
All as per Ser item No 257 here-in-before but one 3 Pin Socket out let 5 Amps on the same board.
All as per Ser item No 257 here-in-before but one 3 Pin Socket out let 5 Amps on the independent board.
All as per Ser item No 257 here-in-before but point wiring with 2.5 sqmm for 15 Amp socket out let & provision of earth wire 2.5 sqmm connected to common eart dolly.
Supply and fix Switch Piano type, single pole, one way 5 Amp complete all as specified & directed.
S&F Switch piano type , single pole , one way 15 Amps complete all as specified and directed.
S&F Socket out let 2-in-1 2/3 pin 5 Amps complete all as specified and directed.
S&F Socket outlet 2-in-1, 3 pin ,5 and 15 amps , flush type complete all as specified & directed.
S&F Ceiling rose, 3 terminal PVC/polycarbonate complete all as specified and directed.
S&F electronic regulator step type 230 Volts single phase 120 watt complete all as specified and directed.
M&L for submain complete with 2x1.5 sqmm, single core, multi stranded copper conductor , PVC insulated and unsheathed FRLS cable 1100 Volts grade, drawn in with and including PVC concealed conduit 20/25 mm dia as per site requirement along walls/ceiling etc including 1.5 sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly complete all as specified and as directed. Note:- (i) all three wire(Phase red colour,neutral black colour and earth wire green colour) should be run through for each individual circuit from the DBs (ii) painting over surface conduit to be done to match with walls/ceiling existing surfaces. (iii) Two run of wire (phase & neutral) and one run of wire (earth conductor) be measured as one length)
All as per ser item No-267 here-in-before but 2X4 Sqmm and 1X 4.0 Sqmm for Earth wire
Supply and fix MCB DB SPN 8 way double door with metal door suitable for housing of MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed at site.
S&F in replacement of MCB SP 6 to 32 Amps 'C' Series 10 KA fixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed.
S&F in replacement of MCB DP 40 Amps 'C' Series 10 KA fixing in DBs, connecting with bottel type copper thimbles.
S&F in replacement of LED tube light fitting 20 watt 230 Volt decorative ultra slim linear LED Lighting with aluminium housing & integrated electronic driver , including all internally pre-wired and inncluding connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed .
S&F in replacement of building LED security light fitting 40 Watt in aluminium pressure die cast aluminium housing with high power LED as lightning sourse and lens embedded PC Cover having IP 65 protection and impect resistance of IK07 with 10 KV Built in super protection device. luminaire with high power LED as light source including suitable size of GI bracket fixed with two Nos GI clamp nut,bolt,washer etc complete all as specified and directed.
Supply, Laying on replacement ,connecting, testing and commissioning of XLPE LT UG cable of size 10 sqmm 2 core PVC insulated and sheathed armoured heavy duty cable 1100 V grade with alu conductor cable all as directed.
Excavation in trenches in loose/soft soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying of cables, poles/stays and struts etc and getting out including trimming sides and forming bottom surface complete, all as specified.
Removing excavated surplus (soil) obtained from excavation to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified.
Returning & filling in including spearing, leveling watering and well ramming in layers not exc 25cm thick, complete all as specified and directed.
Supply and Spread dry river sand for cable cushioning in trenches all as specified and directed.Note : Punned down thickness shall be considered for measurement, complete all as specified and directed.
Supply and lay burnt bricks sub class ‘B’ old size laid dry in trenches across the cable protection all as specified and as directed.
M &L Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed .Note :- i) Earthing test must be carried out in presence of Engr-in-Charge. ii) The earthing result not more than 2 Ohms or disered earth resistance value. iii) Megger required for testing will be be provided at site by the contractor. iv) Contractor shall submit earth resistance testing report before submission of bill.
Taking down XLPE cable removing the materials from site and making good the disturbed surfaces etc complete all as specified and directed.
Supply,laying,jointing,testing and commissioning XLPE insulated,armoured,heavy duty, LT UG cable with aluminium conductor,1100 volts grade cross sectional area 16 sqmm 4 core connected with aluminium lugs connected by cramping tools complete all as specified and directed at site. Note:- Excavation and earth work will be measured and paid separately.
Supply,laying,jointing,testing and commissioning XLPE insulated,armoured,heavy duty, LT UG cable with aluminium conductor,1100 volts grade cross sectional area 50 sqmm 3.5 core connected with aluminium lugs connected by cramping tools complete all as specified and directed. Note:- Excavation and earth work will be measured and paid separately.
Supply,laying,jointing,testing and commissioning XLPE insulated,armoured,heavy duty, LT UG cable with aluminium conductor,1100 volts grade cross sectional area 70 sqmm 3.5 core connected with aluminium lugs connected by cramping tools complete all as specified and directed. Note:- Excavation and earth work will be measured and paid separately.
Supply,laying,jointing,testing and commissioning XLPE insulated,armoured,heavy duty, LT UG cable with aluminium conductor,1100 volts grade cross sectional area 120 sqmm 3.5 core connected with aluminium lugs connected by cramping tools complete all as specified and directed. Note:- Excavation and earth work will be measured and paid separately.
Excavation in trenches in soft/loose soil n.exc 1.5 mtr wide and n.exc 1.5 mtr depth and getting out for taking out / laying of cable complete all as specified and directed.
Supply and providing sand cushioning with dry clean sand 15 cm below cable and 8 cm above the cable complete all as specified and directed. Note : Punned thickness shall be measured for the purpose of payments.
Supply and laying burnt bricks old size sub class-B laid in trenches for cable protection with length of brick perpendicular to length of cable complete all as specified and directed.
Removing surplus excavated material not exc 50 mtrs and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
M&L for trenchless boring under road crossings/foot paths by manual / Boring machine complete all as specified and directed.
Supply and fix in replacement of 50 mm bore GI pipe light grade fixed on pole /trenches/wall/road crossing etc complete with clamp nut bolt etc all as specified and directed.
Supply and installation testing and and commissioning outdoor LT panel totally enclosed weather and vermin proof, suitably ventilated, 440 Volts, 50HZ,AC supply, fully compartamentalised cubical type made out of 3 mm thick CRCA sheet steel for load bearing and 2.0 mm thick non load bearing portions, protection of enclosure IP-54 as per IS-2147 of 1962 complete with pretreatment and powder coating of approved colour including suitable angle iron/flat iron frame work/supports, excavation and earth work, PCC foundation etc, including the follwoing switchgear, supplied fitted and connected internally complete with bus bar all as directed:- (a) 4 Nos verticle copper bus bar of equal size of aluminium conductor with PVC coloured heat shrinkable type sleeves contiuous rating 400 Amps with provision to connect the outgoing cable. (b) MCCB TPN, 415 volt fixed type, 250 Amps with breaking capacity 36 KA- 01 No (Incoming )(Make: L&T/Schnieder/siemens) (b) MCCB TPN, 415 volt fixed type, 100 Amps with breaking capacity 25 KA- 05 No (Outgoing)(Make: L&T/Schnieder/siemens)
Supply and installation testing and and commissioning outdoor LT panel totally enclosed weather and vermin proof, suitably ventilated, 440 Volts, 50HZ,AC supply, fully compartamentalised cubical type made out of 3 mm thick CRCA sheet steel for load bearing and 2.0 mm thick non load bearing portions, protection of enclosure IP-54 as per IS-2147 of 1962 complete with pretreatment and powder coating of approved colour including suitable angle iron/flat iron frame work/supports, excavation and earth work, PCC foundation etc, including the follwoing switchgear, supplied fitted and connected internally complete with bus bar all as directed and specified :- (a) 4 Nos verticle copper bus bar of equal size of aluminium conductor with PVC coloured heat shrinkable type sleeves contiuous rating 250 Amps with provision to connect the outgoing cable. (b) MCCB TPN, 415 volt fixed type, 160 Amps with breaking capacity 25 KA- 01 No (Incoming )(Make: L&T/Schnieder/siemens)
M &L for GI Earthing complete with GI earth plate electrode 60cm x 60cm x6 mm buried directly in ground verticvally to size of earth pit not less than 0.90x 0.90 x 2.25 mtr below ground level with top edge of the plate at a depth not less than 1.5 mtr below ground level, earth plate connected to galvanised earth strip of size 32 x 6 mm, 7.5 mtr long (Min) by means of brazing nuts, bolts, check nuts, & washers ,testing of completion (drawn in earth strip protection pipe light gade GI of size 40 mm dia) by means brazing at both edges with vertical plane of electrode all as shown in plate No 3 of SSR Part - I filling with charcoal dust , and common salt , including necessary excavation and earth work in any type of soil ,perforated watering pipeof size 15 mm dia,funnel with wire mesh,earth strip protection pipe light grade PCC chamber 1:3:6 type C1 (for even finish on both the faces) and RCC cover 1:2:4 Type B1,450 x450 x50 mm thick with 6 mm dia CTD bars 150 mm c/c with 2 Nos of handles of 10 mm dia steel rod all as specified and directed and testing on completion and connected to equipment with lugs and screw nuts etc all as specified and directed by EIC Note : (i) 7.5 RM GI earth wire deemed to be included in quoted rates beyond 7.5 RM wire shall be measured and paid separately. (ii) Earth resistance of earth pit should be not more than 02 Ohms on testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. (iii) Rate quoted by the tenderer is deemed to included salt & Charcoal upto & above 450 mm (Min) top of GI Plate.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safecustody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. etc complete all as specified and directed.
Taking down carefully copper/aluminium sub main wiring of size 2.5/4/6 sqmm from surface/concealed at any height and removing the materials from site and making good the disturbed surfaces of walls,floors roofs etc complete all as specified and directed.
Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and directed.
All as per Ser item No 298 here-in-before but one bell/buzzer point controlled by one push button on the independent board, complete all as specified and directed.
All as per Ser item No.298 here - in - before but one light point controlled by two 2 - way switches,with wire 1.5 Sqmm size, complete all as specified and directed.
S&F Switch Piano type 2 way switch 16 amp 230 v complete all as specified and directed at Site, complete all as specified and directed.
S&F in replacement electric Bell, ding dong type AC 230 Volt single pole complete all as specified & directed.
S&F in replacement Bell push 5 Amps for electric Bell/Buzzer, AC 230 Volt single pole complete all as specified & directed.
S&F electronic regulator step type 230 Volts single phase 120 watt complete all as specified and directed.
M&L for lamp holder , PVC /Polycarbonate type with back plate suitabl for batten fittings complete all as specified and directed.
All as per ser item No 305 here-in-before but 2X2.5 Sqmm and 1X 2.5 Sqmm for Earth wire, complete all as specified and directed.
All as per ser item No305 here-in-before but 2X 6 Sqmm and 1X 6.0 Sqmm for Earth wire, complete all as specified and directed.
S & F for sheet metal enclosure MCB DB TPN 4 way Vertical type with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S&F in replacement of isolator TPN 63 Amps 'C' Series fixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed.
S&F in replacement of isolator DP 63 Amps 'C' Series fixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed.
S&F in replacement of environmental friendly, ultra modern, energy saving, surface mounted, decorative oval plastic bulk head LED light fittings 10 watt capacity ,comprising of high brightness LEDs, IP54 protection complete with all accessories internally pre-wired and inncluding connecting up with 2/3 core twisted flexible copper conductor cable with suitable size of flexible PVC/steel Conduit complete all as specified and directed.
S&F for highly efficient LED bulbs, 9 W complete all as specified and derected
S&F exhaust fan steel body single phase 300 mm sweep complete with louver shutter and including making of hole suitable size fan base after cutting of brick/stone wall /suitable size of water proof ply wood complete all as specified and directed.
Supply, Laying on replacement ,connecting, testing and commissioning of XLPE LT UG cable of size 35 sqmm 3 1/2 core PVC insulated and sheathed armoured heavy duty cable 1100 V grade with alu conductor cable all as directed.
M/S SURYA BUILDERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .