Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.2 LAccepted-AOC 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L1 | Accepted-AOC L1 | |
| 2 | L2₹11.7 L+₹83,020 (7.64%)Rejected-Finance 13 P N DOGRA MARKET GOLE MARKET UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹12.0 L+₹1.1 L (10.3%)Rejected-Finance RAM SHIV COLONY GALI NO 2 NAIKA CHATNAG ROAD JHUNSI PRAYAGRAJ UP 211019 | PRAYAGRAJ | UTTAR PRADESH | 211019 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹12.9 L+₹2.0 L (18.6%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹13.7 L+₹2.8 L (25.9%)Rejected-Finance 1 181 KAMATCHI AMMAN KOVIL STREET KANNAN COLONY CHINTHAMANI MADURAI 625009 | MADURAI | MADURAI | TAMIL NADU | 625009 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
20 Jul 2020, 6:00 pmClosed
GE UTILITIES
GE UTILITIES UDHAMPUR PO GARHI PIN 182121 UDHAMPUR
Repair/Replacement/Maintenance of DG Sets capacity 62.5 KVA to 600 KVA and allied system installed at water supply divsion under GE Utilities Udhampur
2020_MES_352341_1
GE/U-21/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
UDHAMPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE UTILITIES UDHAMPUR
₹30,000
Yes
7 Sept 2020
12 Jun 2020
22 Jul 2020
12 Jun 2020
20 Jul 2020
6 Jul 2020
Amount
Servicing of Diesel Engine Generating Set of capacity 500/600 KVA , any make, Servicing deems to be including the following Process :- (a) Servicing of Engine (i) Re-greasing all grease points (ii) Tighten the nuts, bolts of pipe lines of fuel oil, lubricating oil, water and check for leakages. Examine all main connecting rod connection. (iii) Check water/coolant level in radiator and top up. (vi) Check crank case oil level. (v) Clean lubrication oil filters. (vi) Clean air filters. (vii) Check that lubricating oil contains no water. Examine lubricating oil and renew if needed. (viii) Check tappet clearance and all nuts for tightness. (ix) Wash felt pads of fuel filter. (x) Drain air receiver. (xi) Grease valve stems. (xii) Check all wiring, battery water level, gravity of battery, inspect all brushes and brush holder, cleaning of surface of commuters.
(b) Servicing of alternators (i) Check temp rise of bearings. (ii) Check brushes on exciter commuter and the alternator slip rings run without chattering or sparking. (iii) Check if brushes freely slide in holder and whether brush springs are in order. (iv) Check if oil rings are freely rotating in the bearings. (v) Check oil level in bearings. (vi) Wipe clean the alternator and exciter. (vii) Check all wiring and rectify any defect with new wiring. (viii) Surface and clean the commutater. (ix) Take insulation and earth test on alternator and exciter and if defective investigate cause and remedy. (x) Check joints, clamping and bolting in all the wiring including control panels and rectify any defects. (xi) Check greases in all roller and ball bearings and make up if inadequate. (xii) Check the degree of wear of commuter brushes and renew if necessary. (xiii) Tighten all nuts in the rotors of alternative and exciter. (xiv) Check air gaps between starters and rotors and clean off any projections on the rotor. Note for item No. 1 to 4: Items to be replaced will be measured and paid saparately, as supply only and labour for fixing deemed to be incl as part of servicing.
Description all as per serial item No 1.00 here-in-before but 250 KVA to 320 KVA any make
Description all as per serial item No 1.00 here-in-before but 160 KVA to 200 KVA any make
Description all as per serial item No 1.00 here-in-before but 62.5 KVA to 100 KVA any make
S&F in replacement fuel filter primary & secondary. (Set of Two) suitable of existing make & specification for 500/600 KVA DG set complete all as specified and directed by Engr-in-Charge.
S&F in replacement fuel filter primary & secondary. (Set of Two) suitable of existing make & specification for 250 KVA to 320 KVA DG set complete all as specified and directed by Engr-in-Charge.
S&F in replacement fuel filter primary & secondary. (Set of Two) suitable of existing make & specification for 160 KVA to 200 KVA DG set complete all as specified and directed by Engr-in-Charge.
S&F in replacement fuel filter primary & secondary. (Set of Two) suitable of existing make & specification for 62.5 KVA to 100 KVA DG set complete all as specified and directed by Engr-in-Charge.
S&F in replacement oil filter eliment suitable of existing make & specification for 500/600 KVA DG set complete all as specified and directed by Engr-in-Charge.
S&F in replacement oil filter eliment suitable of existing make & specification for 250KVA to 320 KVA DG set complete all as specified and directed by Engr-in-Charge.
S&F in replacement oil filter eliment suitable of existing make & specification for160 KVA to 200 KVA DG set complete all as specified and directed by Engr-in-Charge.
S&F in replacement oil filter eliment suitable of existing make & specification for 62.5 KVA to 100 KVA DG set complete all as specified and directed by Engr-in-Charge.
S&F in replacement By Pass filter fuel suitable of existing make & specification for 500/600 KVA DG set complete all as specified and directed by Engr-in-Charge.
S&F in replacement By Pass filter fuel suitable of existing make & specification for 250KVA to 320 KVA DG set complete all as specified and directed by Engr-in-Charge.
S&F in replacement By Pass filter fuel suitable of existing make & specification for 62.5KVA to 200 KVA DG set complete all as specified and directed by Engr-in-Charge.
S&F in replacement Air Cleaner filter element including outer and inner element suitable of existing make & specification for 500/600 KVA set complete all as specified and directed by Engr-in-Charge.
S&F in replacement Air Cleaner filter element including outer and inner element suitable of existing make & specification for 250 KVA to 320 KVA set complete all as specified and directed by Engr-in-Charge.
S&F in replacement Air Cleaner filter element including outer and inner element suitable of existing make & specification for 160 KVA to 200 KVA set complete all as specified and directed by Engr-in-Charge.
S&F in replacement Air Cleaner filter element including outer and inner element suitable of existing make & specification for 62.5 KVA to 100 KVA set complete all as specified and directed by Engr-in-Charge.
S&F in replacement 'V' Belt for Dynamo A-49/50 suitable of existing make & specification for 62.5 KVA to 600 KVA set complete all as specified and directed by Engr-in-Charge.
S&F in replacement Tension Belt for Engine suitable of existing make & specification for 500/600 KVA set complete all as specified and directed by Engr-in-Charge.
S&F in replacement Tension Belt for Engine suitable of existing make & specification for 250 KVA to 320 KVA set complete all as specified and directed by Engr-in-Charge.
S&F in replacement Tension Belt for Engine suitable of existing make & specification for 62.5 KVA to 100 KVA set complete all as specified and directed by Engr-in-Charge.
S&F in replacement Air cleaner hose pipe with clamps suitable of existing make & specification for 250 KVA to 600 KVA set complete all as specified and directed by Engr-in-Charge.
S&F in replacement Air cleaner hose pipe with clamps suitable of existing make & specification for 62.5 KVA to 200 KVA set complete all as specified and directed by Engr-in-Charge.
S&F in replacement Safety Control valve suitable of existing make & specification for 250 KVA to 600 KVA set complete all as specified and directed by Engr-in-Charge.
S&F in replacement Safety Control valve suitable of existing make & specification for 62.5 KVA to 200 KVA set complete all as specified and directed by Engr-in-Charge.
S&F in replacement flexible Pipe for fuel pump to PT pump with banjo, banjo washer and nut, bolts suitable of existing make & specification for 500/600 KVA set complete all as specified and directed by Engr-in-Charge.
S&F in replacement flexible Pipe for fuel pump to PT pump with banjo, banjo washer and nut, bolts suitable of existing make & specification for 250 to 320 KVA set complete all as specified and directed by Engr-in-Charge.
S&F in replacement flexible Pipe for fuel pump to PT pump with banjo, banjo washer and nut, bolts suitable of existing make & specification for 62.5 to 100 KVA set complete all as specified and directed by Engr-in-Charge.
Repair/replacement and calibration of FIP of capacity 500/600 KVA DG Sets including replacement of plunger, manifold washer, etc all as required other minor items and testing after refixing on engine and setting the rated RPM complete all as specified and directed by Engr-in-Charge.
Description all as per serial item No 31.00 here-in-before but 250 KVA to 320 KVA any make
Description all as per serial item No 31.00 here-in-before but 160 KVA to 200 KVA any make
Description all as per serial item No 31.00 here-in-before but 62.5 KVA to100 KVA any make
M&L for Servicing/overhauling of injecter nozzle assembly of capacity 500/600 KVA DG set including replacement of nozzles, washers, etc and pressure setting as required and replacement of timing shaft with coupling all as reqd other items complete all as specified and directed by Engr-in-Charge.
Description all as per serial item No 35.00 here-in-before but 250 KVA to 320 KVA any make
Description all as per serial item No 35.00 here-in-before but 160 KVA to 200 KVA any make
Description all as per serial item No 35.00 here-in-before but 62.5 KVA to100 KVA any make
Dismantling and taking out of self starter from mounting and to carryout complete servicing/overhauling of the same with replacement of carbon brush, armature coil, field coil,solenoid switch, bush and pinion and other related components of DG set capacity 500/600 KVA suitable of existing make & specification complete all as specified and directed by Engr-in-Charge.
Description all as per serial item No 39.00 here-in-before but 250 KVA to 320 KVA any make
Description all as per serial item No 39.00 here-in-before but 160 KVA to 200 KVA any make
Description all as per serial item No 39.00 here-in-before but 62.5 KVA to100 KVA any make
Repair/Servicing and overhauling of unsv dynamo by dismantling the same from DG set after taking down the fan belt and pulley. Repair of the same with replacement of armature coil, carbon (1 set) field coil, clutch bearing etc and other related items and duly re-assembling all the dismantled items and refixing the same on mountings and testing complete of DG set capacity 500/600 KVA suitable of existing make & specification complete all as specified and directed by Engr-in-Charge.
Description all as per serial item No 43.00 here-in-before but 250 KVA to 320 KVA any make
Description all as per serial item No 43.00 here-in-before but 160 KVA to 200 KVA any make
Description all as per serial item No 43.00 here-in-before but 62.5 KVA to100 KVA any make
S&F in replacement of old unserviceable of automatic voltage regulator, Diode forward and reverse rotating rectifier assembly complete incl taking down unsv AVR of DG set capacity 500/600 KVA suitable of existing make & specification complete all as specified and directed by Engr-in-Charge.
Description all as per serial item No 47.00 here-in-before but 250 KVA to 320 KVA any make
Description all as per serial item No 47.00 here-in-before but 160 KVA to 200 KVA any make
Description all as per serial item No 47.00 here-in-before but 62.5 KVA to100 KVA any make
M&L for replacement of turbo charger repair kit complete of DG set capacity 500/600 KVA suitable of existing make & specification complete all as specified and directed by Engr-in-Charge.
Description all as per serial item No 51.00 here-in-before but 250 KVA to 320 KVA any make
Description all as per serial item No 51.00 here-in-before but 160 KVA to 200 KVA any make
Description all as per serial item No 51.00 here-in-before but 62.5 KVA to100 KVA any make
Dismantling of radiator complete from DG Sets cleaning/ scraping of depositing manually from outside of the radiator, cleaning of all copper tubes of radiator with descalling solution from inside & outside with forced feed method&with water and aircompressor (by using separate chmical pump water pump & all compressor ) plugging of all leakage in welding, brazing of copper tubes, cleaning of fins and replacement of gaskets etc of DG set capacity 500/600 KVA suitable of existing make & specification complete all as specified and directed by Engr-in-Charge.
Description all as per serial item No 55.00 here-in-before but 250 KVA to 320 KVA any make
Description all as per serial item No 55.00 here-in-before but 160 KVA to 200 KVA any make
Description all as per serial item No 55.00 here-in-before but 62.5 KVA to 100 KVA any make
M&L for dismantling/opening of alternator by disconnecting of cable connection and flexible coupling nut, bolted and alternator foundation nut bolts including taken back on temporary flat form including strip opening of alternator and checking out warn out part of DG sets of make and capacity 62.5 KVA to 600 KVA complete all as specified and directed by Engr-in-Charge.
M&L for taking out warn out rotor armature winding/out field coil stator winding and rewinding of rotor armature/field coil stator with supper enamelled copper winding wire of existing gauge make: Altas of DG sets of make and capacity 62.5 KVA to 600 KVA complete all as specified and directed by Engr-in-Charge. Make: Kirloskar/Cummins/Crompton Greaves
M&L for insulation of armature with class`B' insulation and varnishing of armature winding and drying up to desired temerature of DG sets of capacity 62.5 KVA to 600 KVA complete all as specified and directed by Engr-in-Charge.
M&L for insulation of field coil with class`B'insulation and varnishing of armature winding and drying up to desired temerature of DG sets of capacity 62.5 KVA to 600 KVA complete all as specified and directed by Engr-in-Charge.
Re-assembling of rotor and stator after rewinding and re-fixing of alternator with engine by assembling flexible coupling with alternator , mounting with nuts & bolts including making cable connection complete load of DG set capacity 62.5 KVA to 600 KVA complete all as specified and directed by Engr-in-Charge.
M&L for replacement of self Sarter 12 volt of DG set capacity 62.5 KVA to 200 KVA complete all as specified and directed cat part No 06.034.02.0.00 of kirloskar or equivalent as approved including taking down old unsv.
M&L for replacement of self Sarter 24 volt of DG set capacity 250 KVA to 600 KVA complete all as specified and directed by Engr-in-Charge cat part No 06.034.02.0.00 of kirloskar or equivalent as approved including taking down old unsv.
M&L for base relay 12/24 Volt DC of start position of any capicty DG set and mode of cranking relay complete including taking down old complete all as specified and directed by Engr-in-Charge.
M&L for timer card complete 62.5 KVA to 600 KVA Make: as per sample
M&L for auto stopper circuit wiring including all accessories complete including taking down old of 250 KVA DG set to 600 KVA DG set complete all as specified and directed by Engr-in-Charge.
M&L for auto stopper circuit wiring including all accessories complete including taking down old of 62.5 KVA DG set to 200 KVA DG set complete all as specified and directed by Engr-in-Charge.
Supply and top up Engine Oil SAE 10W/30 complete all as specified and directed by Engr-in-Charge. Make: HP/Indian oil/Castrol or its equivallent
Supply and top up Engine Oil SAE 15W/40 Make: HP/Indian oil/Castrol or its equivallent all as directed by the Engr-in-Charge.
Supply and re-filling of coolent in sealed pack suitable for capacity 62.5KVA to 600 KVA complete all as specified and directed by Engr-in-Charge. Make: Valvoline /Castrol super/equivalent as approved by GE..
Supply and re-filling of distiled water in sealed pack .suitable for battery of capacity 62.5KVA to 600 KVA complete all as specified and directed by Engr-in-Charge.
M&L for replacement battery acid electrode as per sample complete all as specified and directed by Engr-in-Charge.
Taking down old unserviceable of PSO 500 and M&L of PSO 500 controller of DG set AMF of capacity 200 KVA DG set to 600 KVA DG set of any make complete all accessories as per manufacturer including taking down old complete all as specified and directed by Engr-in-Charge.
S&F in replacement of burnt rectifier of size 2” x 2” x 24 plate (set of three).
S&F in replacement of burnt rectifier of size 3” x 3” x 24 plate (set of three).
S&F in replacement of battery terminal with bolt & nuts complete all as specified and directed by Engr-in-Charge.
S&F in repalcement of engine start push button green suitable for any capacity of DG sets complete all as specified and directed by Engr-in-Charge.
S&F in repalcement of of engine stop push button red colour suitable for any cpacity of DG sets complete all as specified and directed by Engr-in-Charge.
S&F in replacement of fan belt A-44, A-42, A-41,A-40 or as existing size suitable for DG sets of capacity 62.5 KVA to 600 KVA complete all as specified and directed by Engr-in-Charge.
S&F in replacement of breather pipe (Moduled rubber hose with reinforcement) suitable for 250 KVA to 600 KV DG Sets complete all as specified and directed by Engr-in-Charge. Make: Kirloskar or equivalent as approved by GE
S&F in replacement of breather pipe ( Moduled rubber hose with reinforcement ) suitable for 62.5 KVA to 200 KV DG Sets complete all as specified and directed by Engr-in-Charge. Make: Kirloskar or equivalent as approved by GE
S& F in repalcement of alternator (Dynamo) 12 Volts suitable for DG sets 62.5 KVA to 200 KVA complete all as specified and directed by Engr-in-Charge. Make: Kirloskar or equivalent as approved by GE
S&F in repalcement of alternator (Dynamo) 24 Volts suitable for DG sets 250 KVA to 600 KVA complete all as specified and directed by Engr-in-Charge. Make: Kirloskar or equivalent as approved by GE
S&F in replacement of stop solenoid assly for S12 VDC micro pump (single coil) heavy duty electal control suitable for 250 KVA to 600 KVA. DG set of existing make & specification complete all as specified and directed by Engr-in-Charge.
S&F in replacement of stop solenoid assly for S12 VDC micro pump (single coil) heavy duty electal control suitable for 62.5 KVA to 200 KVA. DG set of existing make & specification complete all as specified and directed.
S&F in repalcement of battery cable lead (copper) positive terminal size 35 Sqmm (198cm long) as per sample.
S&F in repalcement of battery cable lead (copper) negative terminal size 35 Sqmm (198cm long) as per sample.
S&F in repalcement of inter connection battery cable lead (copper) with terminal size 35 sqmm (30cm long) as per sample
S&F in repalcement of inter connection battery cable lead (copper) with terminal size 35 sqmm (30cm long) as per sample
S&F in replacement of flexible fuel pipe of M30x1.5 union both side (1400mm long) make Kirloskar or equivalent as approved by GE, suitable for DG sets of capacity 250 KVA to 600 KVA
S&F in replacement of flexible fuel pipe of M30x1.5 union both side (1400mm long) make Kirloskar or equivalent as approved by GE, suitable for DG sets of capacity 62.5 KVA to 200 KVA
S&F in repalcement of drain pipe suitable for DG sets of capacity 250 KVA to 500/600 KVA as per existing sample complete
M&L in replacement of slipring assembly of 62.5 KVA to 200 KVA DG Sets complete all as specified and directed by Engr-in-Charge. Make: As per sample site requirement complete all as speified and directed
M&L in replacement of slipring assembly of 250 KVA to 600 KVA DG Sets complete all as specified and directed by Engr-in-Charge. Make: As per sample site requirement complete all as speified and directed
M&L in replacement of Carbon brush suitable for 250 KVA to /600 KVA DG Sets., (set of three as per sample) complete all as specified and directed by Engr-in-Charge.
S&F in replacement of oil temperature gauge of suitable for capacity 62.5KVA to 600 KVA of DG Set complete all as specified and directed by Engr-in-Charge. Make: Kirloskar Cat Part No. 105681020014
S&F in replacement of lub oil pressure gauge flexible pipe of Cat Part No. 100099390654 suitable for capacity 62.5KVA to 600 KVA DG sets complete all as specified and directed by Engr-in-Charge.
M&L in replacement of water temperature gauge suitable for DG set 62.5KVA to 600 KVA DG set (as per sample) complete all as specified and directed by Engr-in-Charge.
S&F in replacement of unsv Oil Pressure gauge 0-10 bar suitable for 62.5 to 600 KVA DG Set complete all as specified and directed by Engr-in-Charge. Make: as per sample.
M&L in replacement of wire braided fuel flexible pipe suitable for DG set capacity 62.5KVA to 600 KVA complete all as specified and directed by Engr-in-Charge.
Dismantling the broken Door of sound proof canopy of the DG Set of ranging 62.5 KVA to 600 KVA and taking it to nearest workshop for repairing, repairing the door with new hinges and nut bolts etc and reassembling the same door at existing position and testing for proper opening and closing of the doors, including repair of the locking system of the door if it is repairable neither replacement of the locking system of the door complete all as specified and directed by Engr-in-Charge. Note: - Any cutting/drilling/welding work involves in the same job is deemed to be include in the quoted rates.
Rubbing the uneven as well as open surfaces of the DG Set of ranging of 600 KVA DG set with emrey paper, cleaning of all the grease and oil substances over the area complete all as specified and directed by Engr-in-Charge.
Rubbing the uneven as well as open surfaces of the DG Set of ranging of 250 to 320 KVA DG set with emrey paper, cleaning of all the grease and oil substances over the area complete all as specified and directed by Engr-in-Charge.
S&F in replacement of current transformer of ratio 100/5 Amps ( Set of three) suitable for 62.5 KVA to 600 KVA complete all as specified and directed by Engr-in-Charge.
Supply and replacement of digital ampere meter of suitable range as per existing size suitable for 62.5 KVA to 600 KVA complete all as specified and directed by Engr-in-Charge.
Supply and replacement of digital voltmeter 0-500 volts as per existing size suitable for 62.5 KVA to 600 KVA complete all as specified and directed by Engr-in-Charge.
Supply and replacement of digital frequency meter as per existing size suitable for 62.5 KVA to 600 KVA complete all as specified and directed by Engr-in-Charge.
Supply and replacement of digital DC voltmeter digital type as per existing size,suitable for 62.5 KVA to 600 KVA complete all as specified and directed by Engr-in-Charge.
S&F in replacement Fuel level sensor gauge suitable for DG set of capacity 62.5 KVA to 600 KVA complete all as specified and directed by Engr-in-Charge. Make: Kirloskar Green Model No 6SL1500TA.
S&F in replacement Hose (Cat part F6.616.06.0.00) suitable for DG set of capacity 62.5 KVA to 200 KVA complete all as specified and directed by Engr-in-Charge. Make: Kirloskar Model No 6SL1500TA.
S&F in replacement Hose pipe (Cat part F6.616.02.0.00) suitable for DG set of capacity 250 KVA to 600 KVA complete all as specified and directed by Engr-in-Charge. Make: Kirloskar Model No 6SL1500TA.
S&F in replacement of unsv governor Control card as per site requirment 62.5 KVA to 200 KVA as per sample complete all as specified and directed by Engr-in-Charge.
S&F in replacement of unsv governor Control card as per site requirment 250 KVA to 500/600 KVA as per sample complete all as specified and directed by Engr-in-Charge.
Replacement old unsv of external battery charging unit 12 Volt complete all as specified and directed by Engr-in-Charge.
Repair/replacement of alternaror dynamo wiring complete DG set to AMF panel bd and bty charging unit as pe site requirment any capacity of DG set 600 KVA complete all as specified and directed by Engr-in-Charge.
Repair/replacement of alternaror dynamo wiring complete DG set to AMF panel bd and bty charging unit as pe site requirment any capacity of DG set 200 KVA to 320 KVA complete all as specified and directed by Engr-in-Charge.
Repair/replacement of alternaror dynamo wiring complete DG set to AMF panel bd and bty charging unit as pe site requirment any capacity of DG set 62.5 KVA to 100 KVA complete all as specified and directed by Engr-in-Charge.
VARDHMAN INTERNATIONAL
TARA ENTERPRISES
JOGINDER SINGH
R K BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .