| 1 | L1₹36.8 LAccepted-AOC NO 235 PSK ILLAM SANKARAN NAGAR CHINNAMMAN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L1 | Accepted-AOC ACCEPTED BEING L1 | |
| 2 | L2₹39.2 L+₹1.5 L (4.00%)Rejected-AOC 1074 BAGYALAKSHMI STREET VENKATESAPURAM ARAKKONAM 631002 | ARAKKONAM | RANIPET | TAMIL NADU | 631002 | L2 | Rejected-AOC REJECTED DUE TO NOT BEING L1 | |
| 3 | L3₹41.7 L+₹4.1 L (10.9%)Rejected-AOC | L3 | Rejected-AOC REJECTED DUE TO NOT BEING L1 |
| Sl No | Description | Qty | Unit | Green Ray Technologies L3 | PSK Enterprises L1 | m/s SRI VALLI ENTERPRISES L2 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, Install, Testing and commissioning LT distribution board (Outdoor Type) suitable size, CPRI Approved factory made, Single door, Cubical type, Compartmentalized design, back door, openable, fabricated out of 3mm thick CRCA steel sheet with suitable size of bus bar and cable chamber weather / dust / vermin proof, suitable spaced totally enclosed in chamber, earthing arrangement, locking arrangement with one no lock with duplicate key duly painted with powder coated paint having danger notice boards and earthing terminals on both sides and including providing the following items incl connection of all incoming and outgoing cables using suitable size lugs and glands, Spreader terminal set, control wiring, complete in all respect all as specified & directed comprising of following items :- .
Note - (i) Panel shall be placed on PCC plateform of size and design recommended by manufacturer and the cost of the same shall be deemed to be included in unit quoted rate incl earth work (iii) The cost deemed to inclued taking down old LT panel and demoloition of old Panel Foundation. (iv) Disconnect/ remove exisitng cable from Panel/MCCB and Cable termination incl suitable size of lugs/ glands etc incl in the quoted rate. (a) MCCB 4P 100 Amps, 16 KA, 415 V, 50 Hz - 1 No (Incomer) (b) MCCB 3P 40 Amps, 16 KA, 415 V, 50 Hz - 2 No (Outgoing) (c) MCB SPN 32 Amps, 10KA, 230V, 50 Hz - 04 No (Outgoing) (d) Multifunction meter, three phase, digital type, with parameters like voltage, ampere, frequency, PF etc, and with suitable rated CT’s complete including selector switch for three phase etc (e) Indication Lamp (R,Y,B), LED Type, With toggle switches – 1 Set of Three | 1 | Each | 1,24,800 ₹1,24,800 | 1,07,000 ₹1,07,000 Lowest | 1,09,800 ₹1,09,800 |
| 2.00 | Supply, Install, Testing and commissioning LT distribution board (Outdoor Type) suitable size, CPRI Approved factory made, Single door, Cubical type, Compartmentalized design, back door, openable, fabricated out of 3mm thick CRCA steel sheet with suitable size of bus bar and cable chamber weather / dust / vermin proof, suitable spaced totally enclosed in chamber, earthing arrangement, locking arrangement with one no lock with duplicate key duly painted with powder coated paint having danger notice boards and earthing terminals on both sides and including providing the following items incl connection of all incoming and outgoing cables using suitable size lugs and glands, Spreader terminal set, control wiring, complete in all respect all as specified & directed by Engineer-in-charge comprising of following items :- .
Note - (i) Panel shall be placed on PCC plateform of size and design recommended by manufacturer and the cost of the same shall be deemed to be included in unit quoted rate incl earth work (iii) The cost deemed to inclued taking down old LT panel and demoloition of old Panel Foundation. (iv) Disconnect/ remove exisitng cable from Panel/MCCB and Cable termination incl suitable size of lugs/ glands etc incl in the quoted rate. (a) MCCB 4P 63 Amps, 16 KA, 415 V, 50 Hz - 1 No (Incomer) (b) MCB TPN 32 Amps, 16 KA, 230 V, 50 Hz - 5 No (Outgoing) (c) Multifunction meter, three phase, digital type, with parameters like voltage, ampere, frequency, PF etc, and with suitable rated CT’s complete including selector switch for three phase etc (d) Indication Lamp (R,Y,B), LED Type, With toggle switches – 1 Set of Three | 1 | Each | 75,200 ₹75,200 | 90,800 ₹90,800 | 54,900 ₹54,900 Lowest |
| 3.00 | Supply, Install, Testing and commissioning LT distribution board (Outdoor Type) suitable size, CPRI Approved factory made, Single door, Cubical type, Compartmentalized design, back door, openable, fabricated out of 3mm thick CRCA steel sheet with suitable size of bus bar and cable chamber weather / dust / vermin proof, suitable spaced totally enclosed in chamber, earthing arrangement, locking arrangement with one no lock with duplicate key duly painted with powder coated paint having danger notice boards and earthing terminals on both sides and including providing the following items incl connection of all incoming and outgoing cables using suitable size lugs and glands, Spreader terminal set, control wiring, complete in all respect all as specified & directed by Engineer-in-charge comprising of following items :- .
Note - (i) Panel shall be placed on PCC plateform of size and design recommended by manufacturer and the cost of the same shall be deemed to be included in unit quoted rate incl earth work (iii) The cost deemed to inclued taking down old LT panel and demoloition of old Panel Foundation. (iv) Disconnect/ remove exisitng cable from Panel/MCCB and Cable termination incl suitable size of lugs/ glands etc incl in the quoted rate. (a) MCCB 4P 150 Amps, 36 KA, 415 V, 50 Hz - 1 No (Incomer) (b) MCCB 3P 63 Amps, 16 KA, 415 V, 50 Hz - 3 No (Outgoing) (c) MCCB 3P 40 Amps, 36 KA, 415 V, 50 Hz -2 No (Outgoing) (d) Multifunction meter, three phase, digital type, with parameters like voltage, ampere, frequency, PF etc, and with suitable rated CT’s complete including selector switch for three phase etc (e) Indication Lamp (R,Y,B), LED Type, With toggle switches – 1 Set of Three | 1 | Each | 1,48,800 ₹1,48,800 | 1,79,000 ₹1,79,000 | 1,30,410 ₹1,30,410 Lowest |
| 4.00 | Supply, Install, Testing and commissioning LT distribution board (Outdoor Type) suitable size, CPRI Approved factory made, Single door, Cubical type, Compartmentalized design, back door, openable, fabricated out of 3mm thick CRCA steel sheet with suitable size of bus bar and cable chamber weather / dust / vermin proof, suitable spaced totally enclosed in chamber, earthing arrangement, locking arrangement with one no lock with duplicate key duly painted with powder coated paint having danger notice boards and earthing terminals on both sides and including providing the following items incl connection of all incoming and outgoing cables using suitable size lugs and glands, Spreader terminal set, control wiring, complete in all respect all as specified & directed by Engineer-in-charge comprising of following items :- .
Note - (i) Panel shall be placed on PCC plateform of size and design recommended by manufacturer and the cost of the same shall be deemed to be included in unit quoted rate incl earth work (iii) The cost deemed to inclued taking down old LT panel and demoloition of old Panel Foundation. (iv) Disconnect/ remove exisitng cable from Panel/MCCB and Cable termination incl suitable size of lugs/ glands etc incl in the quoted rate. (a) MCCB 4P 350 Amps, 36 KA, 415 V, 50 Hz - 1 No (Incomer) (b) MCB 3P 150 Amps, 36 KA, 230 V, 50 Hz -8 No (Outgoing) (C) MCB 3P 125 Amps, 16 KA, 230 V, 50 Hz -1 No (Outgoing) (d) Multifunction meter, three phase, digital type, with parameters like voltage, ampere, frequency, PF etc, and with suitable rated CT’s complete including selector switch for three phase etc (e) Indication Lamp (R,Y,B), LED Type, With toggle switches – 1 Set of Three | 1 | Each | 2,88,000 ₹2,88,000 | 2,87,000 ₹2,87,000 | 2,52,000 ₹2,52,000 Lowest |
| 5.00 | Supply, Install, Testing and commissioning LT distribution board (Outdoor Type) suitable size, CPRI Approved factory made, Single door, Cubical type, Compartmentalized design, back door, openable, fabricated out of 3mm thick CRCA steel sheet with suitable size of bus bar and cable chamber weather / dust / vermin proof, suitable spaced totally enclosed in chamber, earthing arrangement, locking arrangement with one no lock with duplicate key duly painted with powder coated paint having danger notice boards and earthing terminals on both sides and including providing the following items incl connection of all incoming and outgoing cables using suitable size lugs and glands, Spreader terminal set, control wiring, complete in all respect all as specified & directed by Engineer-in-charge comprising of following items :- .
Note - (i) Panel shall be placed on PCC plateform of size and design recommended by manufacturer and the cost of the same shall be deemed to be included in unit quoted rate incl earth work (iii) The cost deemed to inclued taking down old LT panel and demoloition of old Panel Foundation. (iv) Disconnect/ remove exisitng cable from Panel/MCCB and Cable termination incl suitable size of lugs/ glands etc incl in the quoted rate. (a) MCCB 4P 350 Amps, 36 KA, 415 V, 50 Hz - 1 No (Incomer) (b) MCCB 3P 125 Amps, 36 KA, 415 V, 50 Hz - 7 No (Outgoing) (c) Multifunction meter, three phase, digital type, with parameters like voltage, ampere, frequency, PF etc, and with suitable rated CT’s complete including selector switch for three phase etc (d) Indication Lamp (R,Y,B), LED Type, With toggle switches – 1 Set of Three | 1 | Each | 2,88,000 ₹2,88,000 | 2,79,000 ₹2,79,000 | 2,52,000 ₹2,52,000 Lowest |
| 6.00 | Supply, Install, Testing and commissioning LT distribution board (Outdoor Type) suitable size, CPRI Approved factory made, Single door, Cubical type, Compartmentalized design, back door, openable, fabricated out of 3mm thick CRCA steel sheet with suitable size of bus bar and cable chamber weather / dust / vermin proof, suitable spaced totally enclosed in chamber, earthing arrangement, locking arrangement with one no lock with duplicate key duly painted with powder coated paint having danger notice boards and earthing terminals on both sides and including providing the following items incl connection of all incoming and outgoing cables using suitable size lugs and glands, Spreader terminal set, control wiring, complete in all respect all as specified & directed by Engineer-in-charge comprising of following items :- .
Note - (i) Panel shall be placed on PCC plateform of size and design recommended by manufacturer and the cost of the same shall be deemed to be included in unit quoted rate incl earth work (iii) The cost deemed to inclued taking down old LT panel and demoloition of old Panel Foundation. ((iv) Disconnect/ remove exisitng cable from Panel/MCCB and Cable termination incl suitable size of lugs/ glands etc incl in the quoted rate. (a) MCCB 4P 100 Amps, 16 KA, 415 V, 50 Hz - 1 No (Incomer) (b) MCCB 3P 63 Amps, 16 KA, 415 V, 50 Hz -4 No (Outgoing) (c) MCCB 3P 40 Amps, 16 KA, 415 V, 50 Hz -1 No (Outgoing) (d) Multifunction meter, three phase, digital type, with parameters like voltage, ampere, frequency, PF etc, and with suitable rated CT’s complete including selector switch for three phase etc. (e) Indication Lamp (R,Y,B), LED Type, With toggle switches – 1 Set of Three | 1 | Each | 1,45,600 ₹1,45,600 | 1,70,000 ₹1,70,000 | 1,26,000 ₹1,26,000 Lowest |
| 7.00 | Supply, Install, Testing and commissioning LT distribution board (Outdoor Type) suitable size, CPRI Approved factory made, Single door, Cubical type, Compartmentalized design, back door, openable, fabricated out of 3mm thick CRCA steel sheet with suitable size of bus bar and cable chamber weather / dust / vermin proof, suitable spaced totally enclosed in chamber, earthing arrangement, locking arrangement with one no lock with duplicate key duly painted with powder coated paint having danger notice boards and earthing terminals on both sides and including providing the following items incl connection of all incoming and outgoing cables using suitable size lugs and glands, Spreader terminal set, control wiring, complete in all respect all as specified & directed by Engineer-in-charge comprising of following items :- .
Note - (i) Panel shall be placed on PCC plateform of size and design recommended by manufacturer and the cost of the same shall be deemed to be included in unit quoted rate incl earth work (iii) The cost deemed to inclued taking down old LT panel and demoloition of old Panel Foundation. (iv) Disconnect/ remove exisitng cable from Panel/MCCB and Cable termination incl suitable size of lugs/ glands etc incl in the quoted rate. (a) MCCB 4P 320 Amps, 36 KA, 415 V, 50 Hz - 1 No (Incomer) (b) MCCB 3P 125 Amps, 36 KA, 415 V, 50 Hz - 7 No (Outgoing) (c) Multifunction meter, three phase, digital type, with parameters like voltage, ampere, frequency, PF etc, and with suitable rated CT’s complete including selector switch for three phase etc (d) Indication Lamp (R,Y,B), LED Type, With toggle switches – 1 Set of Three | 1 | Each | 2,88,000 ₹2,88,000 | 2,60,000 ₹2,60,000 | 2,52,000 ₹2,52,000 Lowest |
| 8.00 | Supply, Install, Testing and commissioning LT distribution board (Outdoor Type) suitable size, CPRI Approved factory made, Single door, Cubical type, Compartmentalized design, back door, openable, fabricated out of 3mm thick CRCA steel sheet with suitable size of bus bar and cable chamber weather / dust / vermin proof, suitable spaced totally enclosed in chamber, earthing arrangement, locking arrangement with one no lock with duplicate key duly painted with powder coated paint having danger notice boards and earthing terminals on both sides and including providing the following items incl connection of all incoming and outgoing cables using suitable size lugs and glands, Spreader terminal set, control wiring, complete in all respect all as specified & directed by Engineer-in-charge comprising of following items :- .
Note - (i) Panel shall be placed on PCC plateform of size and design recommended by manufacturer and the cost of the same shall be deemed to be included in unit quoted rate incl earth work (iii) The cost deemed to inclued taking down old LT panel and demoloition of old Panel Foundation. (iv) Disconnect/ remove exisitng cable from Panel/MCCB and Cable termination incl suitable size of lugs/ glands etc incl in the quoted rate. (a) MCCB 4P 250 Amps, 36 KA, 415 V, 50 Hz - 1 No (Incomer) (b) MCCB 3P 125 Amps, 36 KA, 415 V, 50 Hz - 6 No (Outgoing) (c) Multifunction meter, three phase, digital type, with parameters like voltage, ampere, frequency, PF etc, and with suitable rated CT’s complete including selector switch for three phase etc (d) Indication Lamp (R,Y,B), LED Type, With toggle switches – 1 Set of Three | 1 | Each | 2,72,000 ₹2,72,000 | 2,51,000 ₹2,51,000 | 2,34,900 ₹2,34,900 Lowest |
| 9.00Material and labour for straight through cable cold shrinkable joint kit for 1.1 KV grade complete with jointing material and accessories like lugs etc complete suitable for following size XLPE cable complete all as specified and as directed. | ||||||
| 9.10 | (a) 185 sqmm 3.5 core to 240 sqmm 3.5 core | 12 | Each | 5,500 ₹66,000 | 4,400 ₹52,800 Lowest | 4,500 ₹54,000 |
Tender Value
₹41.9 L
EMD Value
₹83,700
Closing Date
31 Aug 2026, 6:00 pmClosed
Garrison Engineer (M) NAS Arakkonam
Garrison Engineer (M) NAS Arakkonam 631006
REPAIR AND REPLACEMENT OF LT PANELS DISTRIBUTION BOX AND CONNECTED ITEMS IN CERTAIN AREAS UNDER GE M ARAKKONAM
2026_MES_782324_1
8617E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Garrison Engineer (M) NAS Arakkonam
As per NIT
7 documents required · 7 mandatory
₹500
Garrison Engineer (M) NAS Arakkonam
₹83,700
Yes
30 Sept 2026
3 Aug 2026
2 Sept 2026
3 Aug 2026
31 Aug 2026
17 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, Install, Testing and commissioning LT distribution board (Outdoor Type) suitable size, CPRI Approved factory made, Single door, Cubical type, Compartmentalized design, back door, openable, fabricated out of 3mm thick CRCA steel sheet with suitable size of bus bar and cable chamber weather / dust / vermin proof, suitable spaced totally enclosed in chamber, earthing arrangement, locking arrangement with one no lock with duplicate key duly painted with powder coated paint having danger notice boards and earthing terminals on both sides and including providing the following items incl connection of all incoming and outgoing cables using suitable size lugs and glands, Spreader terminal set, control wiring, complete in all respect all as specified & directed comprising of following items :- .
Note - (i) Panel shall be placed on PCC plateform of size and design recommended by manufacturer and the cost of the same shall be deemed to be included in unit quoted rate incl earth work (iii) The cost deemed to inclued taking down old LT panel and demoloition of old Panel Foundation. (iv) Disconnect/ remove exisitng cable from Panel/MCCB and Cable termination incl suitable size of lugs/ glands etc incl in the quoted rate. (a) MCCB 4P 100 Amps, 16 KA, 415 V, 50 Hz - 1 No (Incomer) (b) MCCB 3P 40 Amps, 16 KA, 415 V, 50 Hz - 2 No (Outgoing) (c) MCB SPN 32 Amps, 10KA, 230V, 50 Hz - 04 No (Outgoing) (d) Multifunction meter, three phase, digital type, with parameters like voltage, ampere, frequency, PF etc, and with suitable rated CT’s complete including selector switch for three phase etc (e) Indication Lamp (R,Y,B), LED Type, With toggle switches – 1 Set of Three | 1 | Each | - | - |
| 2 | Supply, Install, Testing and commissioning LT distribution board (Outdoor Type) suitable size, CPRI Approved factory made, Single door, Cubical type, Compartmentalized design, back door, openable, fabricated out of 3mm thick CRCA steel sheet with suitable size of bus bar and cable chamber weather / dust / vermin proof, suitable spaced totally enclosed in chamber, earthing arrangement, locking arrangement with one no lock with duplicate key duly painted with powder coated paint having danger notice boards and earthing terminals on both sides and including providing the following items incl connection of all incoming and outgoing cables using suitable size lugs and glands, Spreader terminal set, control wiring, complete in all respect all as specified & directed by Engineer-in-charge comprising of following items :- .
Note - (i) Panel shall be placed on PCC plateform of size and design recommended by manufacturer and the cost of the same shall be deemed to be included in unit quoted rate incl earth work (iii) The cost deemed to inclued taking down old LT panel and demoloition of old Panel Foundation. (iv) Disconnect/ remove exisitng cable from Panel/MCCB and Cable termination incl suitable size of lugs/ glands etc incl in the quoted rate. (a) MCCB 4P 63 Amps, 16 KA, 415 V, 50 Hz - 1 No (Incomer) (b) MCB TPN 32 Amps, 16 KA, 230 V, 50 Hz - 5 No (Outgoing) (c) Multifunction meter, three phase, digital type, with parameters like voltage, ampere, frequency, PF etc, and with suitable rated CT’s complete including selector switch for three phase etc (d) Indication Lamp (R,Y,B), LED Type, With toggle switches – 1 Set of Three | 1 | Each | - | - |
| 3 | Supply, Install, Testing and commissioning LT distribution board (Outdoor Type) suitable size, CPRI Approved factory made, Single door, Cubical type, Compartmentalized design, back door, openable, fabricated out of 3mm thick CRCA steel sheet with suitable size of bus bar and cable chamber weather / dust / vermin proof, suitable spaced totally enclosed in chamber, earthing arrangement, locking arrangement with one no lock with duplicate key duly painted with powder coated paint having danger notice boards and earthing terminals on both sides and including providing the following items incl connection of all incoming and outgoing cables using suitable size lugs and glands, Spreader terminal set, control wiring, complete in all respect all as specified & directed by Engineer-in-charge comprising of following items :- .
Note - (i) Panel shall be placed on PCC plateform of size and design recommended by manufacturer and the cost of the same shall be deemed to be included in unit quoted rate incl earth work (iii) The cost deemed to inclued taking down old LT panel and demoloition of old Panel Foundation. (iv) Disconnect/ remove exisitng cable from Panel/MCCB and Cable termination incl suitable size of lugs/ glands etc incl in the quoted rate. (a) MCCB 4P 150 Amps, 36 KA, 415 V, 50 Hz - 1 No (Incomer) (b) MCCB 3P 63 Amps, 16 KA, 415 V, 50 Hz - 3 No (Outgoing) (c) MCCB 3P 40 Amps, 36 KA, 415 V, 50 Hz -2 No (Outgoing) (d) Multifunction meter, three phase, digital type, with parameters like voltage, ampere, frequency, PF etc, and with suitable rated CT’s complete including selector switch for three phase etc (e) Indication Lamp (R,Y,B), LED Type, With toggle switches – 1 Set of Three | 1 | Each | - | - |
| 4 | Supply, Install, Testing and commissioning LT distribution board (Outdoor Type) suitable size, CPRI Approved factory made, Single door, Cubical type, Compartmentalized design, back door, openable, fabricated out of 3mm thick CRCA steel sheet with suitable size of bus bar and cable chamber weather / dust / vermin proof, suitable spaced totally enclosed in chamber, earthing arrangement, locking arrangement with one no lock with duplicate key duly painted with powder coated paint having danger notice boards and earthing terminals on both sides and including providing the following items incl connection of all incoming and outgoing cables using suitable size lugs and glands, Spreader terminal set, control wiring, complete in all respect all as specified & directed by Engineer-in-charge comprising of following items :- .
Note - (i) Panel shall be placed on PCC plateform of size and design recommended by manufacturer and the cost of the same shall be deemed to be included in unit quoted rate incl earth work (iii) The cost deemed to inclued taking down old LT panel and demoloition of old Panel Foundation. (iv) Disconnect/ remove exisitng cable from Panel/MCCB and Cable termination incl suitable size of lugs/ glands etc incl in the quoted rate. (a) MCCB 4P 350 Amps, 36 KA, 415 V, 50 Hz - 1 No (Incomer) (b) MCB 3P 150 Amps, 36 KA, 230 V, 50 Hz -8 No (Outgoing) (C) MCB 3P 125 Amps, 16 KA, 230 V, 50 Hz -1 No (Outgoing) (d) Multifunction meter, three phase, digital type, with parameters like voltage, ampere, frequency, PF etc, and with suitable rated CT’s complete including selector switch for three phase etc (e) Indication Lamp (R,Y,B), LED Type, With toggle switches – 1 Set of Three | 1 | Each | - | - |
| 5 | Supply, Install, Testing and commissioning LT distribution board (Outdoor Type) suitable size, CPRI Approved factory made, Single door, Cubical type, Compartmentalized design, back door, openable, fabricated out of 3mm thick CRCA steel sheet with suitable size of bus bar and cable chamber weather / dust / vermin proof, suitable spaced totally enclosed in chamber, earthing arrangement, locking arrangement with one no lock with duplicate key duly painted with powder coated paint having danger notice boards and earthing terminals on both sides and including providing the following items incl connection of all incoming and outgoing cables using suitable size lugs and glands, Spreader terminal set, control wiring, complete in all respect all as specified & directed by Engineer-in-charge comprising of following items :- .
Note - (i) Panel shall be placed on PCC plateform of size and design recommended by manufacturer and the cost of the same shall be deemed to be included in unit quoted rate incl earth work (iii) The cost deemed to inclued taking down old LT panel and demoloition of old Panel Foundation. (iv) Disconnect/ remove exisitng cable from Panel/MCCB and Cable termination incl suitable size of lugs/ glands etc incl in the quoted rate. (a) MCCB 4P 350 Amps, 36 KA, 415 V, 50 Hz - 1 No (Incomer) (b) MCCB 3P 125 Amps, 36 KA, 415 V, 50 Hz - 7 No (Outgoing) (c) Multifunction meter, three phase, digital type, with parameters like voltage, ampere, frequency, PF etc, and with suitable rated CT’s complete including selector switch for three phase etc (d) Indication Lamp (R,Y,B), LED Type, With toggle switches – 1 Set of Three | 1 | Each | - | - |
| 6 | Supply, Install, Testing and commissioning LT distribution board (Outdoor Type) suitable size, CPRI Approved factory made, Single door, Cubical type, Compartmentalized design, back door, openable, fabricated out of 3mm thick CRCA steel sheet with suitable size of bus bar and cable chamber weather / dust / vermin proof, suitable spaced totally enclosed in chamber, earthing arrangement, locking arrangement with one no lock with duplicate key duly painted with powder coated paint having danger notice boards and earthing terminals on both sides and including providing the following items incl connection of all incoming and outgoing cables using suitable size lugs and glands, Spreader terminal set, control wiring, complete in all respect all as specified & directed by Engineer-in-charge comprising of following items :- .
Note - (i) Panel shall be placed on PCC plateform of size and design recommended by manufacturer and the cost of the same shall be deemed to be included in unit quoted rate incl earth work (iii) The cost deemed to inclued taking down old LT panel and demoloition of old Panel Foundation. ((iv) Disconnect/ remove exisitng cable from Panel/MCCB and Cable termination incl suitable size of lugs/ glands etc incl in the quoted rate. (a) MCCB 4P 100 Amps, 16 KA, 415 V, 50 Hz - 1 No (Incomer) (b) MCCB 3P 63 Amps, 16 KA, 415 V, 50 Hz -4 No (Outgoing) (c) MCCB 3P 40 Amps, 16 KA, 415 V, 50 Hz -1 No (Outgoing) (d) Multifunction meter, three phase, digital type, with parameters like voltage, ampere, frequency, PF etc, and with suitable rated CT’s complete including selector switch for three phase etc. (e) Indication Lamp (R,Y,B), LED Type, With toggle switches – 1 Set of Three | 1 | Each | - | - |
| 7 | Supply, Install, Testing and commissioning LT distribution board (Outdoor Type) suitable size, CPRI Approved factory made, Single door, Cubical type, Compartmentalized design, back door, openable, fabricated out of 3mm thick CRCA steel sheet with suitable size of bus bar and cable chamber weather / dust / vermin proof, suitable spaced totally enclosed in chamber, earthing arrangement, locking arrangement with one no lock with duplicate key duly painted with powder coated paint having danger notice boards and earthing terminals on both sides and including providing the following items incl connection of all incoming and outgoing cables using suitable size lugs and glands, Spreader terminal set, control wiring, complete in all respect all as specified & directed by Engineer-in-charge comprising of following items :- .
Note - (i) Panel shall be placed on PCC plateform of size and design recommended by manufacturer and the cost of the same shall be deemed to be included in unit quoted rate incl earth work (iii) The cost deemed to inclued taking down old LT panel and demoloition of old Panel Foundation. (iv) Disconnect/ remove exisitng cable from Panel/MCCB and Cable termination incl suitable size of lugs/ glands etc incl in the quoted rate. (a) MCCB 4P 320 Amps, 36 KA, 415 V, 50 Hz - 1 No (Incomer) (b) MCCB 3P 125 Amps, 36 KA, 415 V, 50 Hz - 7 No (Outgoing) (c) Multifunction meter, three phase, digital type, with parameters like voltage, ampere, frequency, PF etc, and with suitable rated CT’s complete including selector switch for three phase etc (d) Indication Lamp (R,Y,B), LED Type, With toggle switches – 1 Set of Three | 1 | Each | - | - |
| 8 | Supply, Install, Testing and commissioning LT distribution board (Outdoor Type) suitable size, CPRI Approved factory made, Single door, Cubical type, Compartmentalized design, back door, openable, fabricated out of 3mm thick CRCA steel sheet with suitable size of bus bar and cable chamber weather / dust / vermin proof, suitable spaced totally enclosed in chamber, earthing arrangement, locking arrangement with one no lock with duplicate key duly painted with powder coated paint having danger notice boards and earthing terminals on both sides and including providing the following items incl connection of all incoming and outgoing cables using suitable size lugs and glands, Spreader terminal set, control wiring, complete in all respect all as specified & directed by Engineer-in-charge comprising of following items :- .
Note - (i) Panel shall be placed on PCC plateform of size and design recommended by manufacturer and the cost of the same shall be deemed to be included in unit quoted rate incl earth work (iii) The cost deemed to inclued taking down old LT panel and demoloition of old Panel Foundation. (iv) Disconnect/ remove exisitng cable from Panel/MCCB and Cable termination incl suitable size of lugs/ glands etc incl in the quoted rate. (a) MCCB 4P 250 Amps, 36 KA, 415 V, 50 Hz - 1 No (Incomer) (b) MCCB 3P 125 Amps, 36 KA, 415 V, 50 Hz - 6 No (Outgoing) (c) Multifunction meter, three phase, digital type, with parameters like voltage, ampere, frequency, PF etc, and with suitable rated CT’s complete including selector switch for three phase etc (d) Indication Lamp (R,Y,B), LED Type, With toggle switches – 1 Set of Three | 1 | Each | - | - |
| 9Material and labour for straight through cable cold shrinkable joint kit for 1.1 KV grade complete with jointing material and accessories like lugs etc complete suitable for following size XLPE cable complete all as specified and as directed. | |||||
| 0.9 | (a) 185 sqmm 3.5 core to 240 sqmm 3.5 core | 12 | Each | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.72 MB
Tenderdocuments8617.pdf
Tender Documents • 1.33 MB
NIT8617.pdf
Additional Documents • 0.71 MB
BOQ_876454.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .