| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.8 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹4.9 L+₹10,879.40 (2.27%)Rejected-AOC | L2 | Rejected-AOC Other than lowest | |
| 3 | L3₹5.3 L+₹50,056.10 (10.5%)Rejected-AOC C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L3 | Rejected-AOC Other than lowest |
Tender Value
Refer Docs
EMD Value
₹13,500
Closing Date
9 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE(I)CIF(U)
AGE(I)CIF(U)
SPECIAL REPAIR TO PUMP SET PANELS, VALVES AND ALLIED WORKS AT SILA GRN UNDER AGE (I) CIF(U)
2020_MES_402816_1
AGE(I)CIF(U)-32/2020-21
Open Tender
Civil Works
Item Rate
180 days
AOR of AGE(I)CIF(U)
As per NIT
9 documents required · 9 mandatory
₹500
AGE(I)CIF(U)
₹13,500
Yes
9 Mar 2021
11 Dec 2020
11 Jan 2021
11 Dec 2020
9 Jan 2021
28 Dec 2020
60 days
Amount
Excavating in trenches n.exc 1.5m wide and n.exc 1.5m in depth in any type of soil for laying of cable or pipes, trimming the sides, forming bottom surfaces to required leve, n.exc 10sqm on plan and getting out, complete, all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick, complete, all as specified and directed.
Removing surplus soil to a distance n.exc 50m and deposited where directed at a level not exceeding 1.50 m above the starting point, complete, all as specified and directed.
M&L for dry sand cushioning to under ground cable 8cm thick before laying the cable and 15cm thick after laying the streching the cable in trenches, including hand punning and consolidating complete all as specified. Note : for payment purpose punned thickness shall be measured.
M&L for sub class ‘B brick, old size, as cable protection cover, laid dry, flat, transversally along the length of cable, on sand cushioning, with width equal to the length of the brick, complete, all as specified and directed.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanised steel strips or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 70 sqmm 3.5 core, complete all as specified and directed.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanised steel strips or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 50 sqmm 3.5 core, complete all as specified and directed.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanised steel strips or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 25 sqmm 4 core, complete all as specified and directed.
M & L Earthing for machinery / equipment Installed at power house / substation using GI strip as earth lead and MS galvanized steel earth plate electrode 600x600x 6.3mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate is not less than 1.5 mtr below normal ground level connected to galvanized iron strips 32x6mm with GI pipe, nuts, bolts and washers complete and ncluding test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw and PCC pit of required size in PCC 1:2:4 type B1 and RCC cover with frame, charcoal, common salt around the earth plate watering pipe 20mm light grade/galvanized and 40mm dia GI pipe med grade for protection of GI strip with funnel and wire mesh for watering necessary excavation and earth works in any type of soil complete all as specified and directed as shown in Electrical Plate No. 3 of SSR ( Part-I) of 2009 and testing on completion. (Note : Earth result should not exceed 2 Ohms)
Supply and fixing 80 mm bore cast iron sluice valve class PN-1.0 ISI marked, both ends flanged, stainless steel spindle, with iron wheel and necessary jointing materials, nuts & bolts, washers etc for making two flanged joints, complete, all as specified and directed. Make: Kirloskar/BIR/Zoloto as approved as per make list.
Supply and fixing 100 mm bore cast iron air release valve ISI marked with single air outlet, confirming to IS 14845 including necessary jointing materials, nuts & bolts, washers etc and fixing up CI water supply mains 100mm bore, complete, all as specified and directed. Make: Kirloskar/BIR/Zoloto as approved as per make list.
Supply and fixing 80 mm bore cast iron foot valve ISI marked flanzed / screwed, ball type, confirming to IS 4038 including necessary jointing materials, nuts & bolts, washers etc and fixing up, complete, all as specified and directed. Make: Kirloskar/BIR/Zoloto as approved as per make list.
Cutting of road not exeeding 100 CM depth for laying of UG Cable including making good the suface of road with cement plaster mix 1:2 of suitable quantity, complete all as specified and directed.
S & F of tubes light grade of 80 mm bore galvanised with all fitting for cable protection trenches / wall / on pole including necessary clamps sets and nut & bolts complete all as specified and directed by Engineer-in-Charge.
Supply and fix capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase 440 V, 50 Hz System for permissible non- linear load 15% of 5 KVAR capacity, complete all as specified and directed by Engineer-in-Charge. Make :- Havells or equivalent in L&T/Legrand
Supply and fix capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase 440 V, 50 Hz System for permissible non- linear load 15% of 10 KVAR capacity, complete all as specified and directed by Engineer-in-Charge. Make :- Havells or equivalent in L&T/Legrand
Supply and fix capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase 440 V, 50 Hz System for permissible non- linear load 15% of 25 KVAR capacity, complete all as specified and directed by Engineer-in-Charge. Make :- Havells or equivalent in L&T/Legrand
Supply and fixing flat PVC insulated and PVC sheathed water proof 3 core16 sqmm nominal section area stranded copper conductor for Submersible Pump Motors incuding connection upto star delta starter, complete all as specified and as directed by Engr-in-charge. Make:-Havells, Cat Part No :- WHPNDSKG3010 or equivalent in Plaza/Polycab/Finolex.
Supply and fixing flat PVC insulated and PVC sheathed water proof 3 core10 sqmm nominal section area stranded copper conductor for Submersible Pump Motors incuding connection upto star delta starter, complete all as specified and as directed by Engr-in-charge. Make:-Havells, Cat Part No :- WHPNDSKG3016 or equivalent in Plaza/Polycab/Finolex.
Jiwan Singh
MAMTA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .