Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹83.5 LAccepted-AOC PLOT NO 1134 1196 MORIVALI VILLAGE TAL AMBARNATH DIST THANE AMBERNATH 421505 | AMBERNATH | THANE | MAHARASHTRA | 421505 | L-1 | Accepted-AOC AOC | |
| 2 | L-2₹85.3 L+₹40,570.18 (0.48%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L-2 | Rejected-Finance Being L-2 | |
| 3 | L-3₹85.3 L+₹43,181.84 (0.51%)Rejected-Finance | L-3 | Rejected-Finance Being L-3 | |
| 4 | L4₹86.1 L+₹1.2 L (1.47%)Rejected-Finance 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | L4 | Rejected-Finance Being L-4 | |
| 5 | Rejected-Technical SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | - | Rejected-Technical Due to valid DD not uploaded |
Tender Value
₹86.8 L
EMD Value
₹1.6 L
Closing Date
21 Jun 2023, 6:00 pmClosed
CWE (SUBS) MUMBAI
Commander Works Engineer Subs NCHC Powai Bhandup Post Office Mumbai 400 078
MANUAL RESCUE AND OPERATIONAL RESCUE OF NEW AC PLANTS, REPAIR AND MAINTENANCE OF SUMMER AND COOLING APPLIANCES, INTERNAL ELECTRIFICATION AND ALLIED WORKS AS SPECIFIED IN SCOPE OF WORK UNDER GE (NW) MANKHURD
2023_MES_598146_1
8845/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
MANKHURD
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (NW) MANKHURD
₹1.6 L
Yes
25 Jul 2023
24 May 2023
23 Jun 2023
24 May 2023
21 Jun 2023
14 Jun 2023
Amount
M&L for cleaning underground / semi-underground sumps of 10,000 gallons capacity by draining out sludge from bottom blocking all inlet/outlet, removing algae-fungal growth from wall, floor, ceiling by wire brush/ water jet pressure machine, cleaning complete surface and dis-infecting with bleaching powder as required complete all as specified and directed.
All as per item No 1 above but 20,000 gallons capacity.
M & L for cleaning of over head reservoir 20,000 gallons by draining out water,removing sludge, algae-fungal growth from walls/floor, roof by rubbing with wire brush and disinfecting the reservoir with bleaching powder as required draining out and making reservoir totally clean complete all as specified and directed.
M & L for cleaning RCC / PVC Service Tanks upto 500 Ltrs capacity by draining out entire water, removing sludge, mud etc, cleaning the ceilings from spider webs, mud accumulations etc., with water jets etc., brushing / rubbing with wire brush / nylon brush / mop to remove all algae / fungal growth and moss etc. entirely from walls, floors, etc. washing clean with fresh water by using water jets and then again washing and treating with anti - bacterial agents, disinfectants and bleaching powder, as required at site and writing in paint with approved font of size "Date of Cleaning" and "Capacity" of sumps and cleaning off the premises complete all as specified and directed by the Engineer-in-charge.
-Ditto- all as per item No 4 above but 1,000 Ltrs capacity.
-Ditto- all as per item No 4 above but 1001 Ltrs to 2,000 Ltrs capacity.
-Ditto- all as per item No 4 above but 2001 Ltrs to 5,000 Ltrs capacity.
M & L for servicing of Centrifugal pump set upto 20 HP by taking to workshop and opening end covers, greasing the bearings, replacing worn out nut, bolts, gasket, air release valve key, gland stuffing box male/ female set, Rubber bush and painting one coat of synthetic enamel paint, including writing/marking in 1" size letters SM & MES No and reinstalling in existing foundation complete with testing all as specified and directed by Engr-in-Charge. Note :- (i) Parts if required for pump shall be measured and paid separately here-in-after under another item as 'supply only.
All as per item No 8 above but Pump set 5 HP
Supply only Ball bearing 6207 Make-SKF or equivalent as approved by GE
Supply only Ball bearing 6208 Make-SKF or equivalent as approved by GE
M&L for rewinding of electric motor 3 phase 50 Hz 415 volt for 15 HP capacity complete all as directed and specified. (a) Disconnecitng, dismantling existing burnt winding from motor and rewinding complete with super enamelled copper winding wire of matching gauge including all insulation material such as PVC insulated sheet, cotton tape sleeves varnish etc., (b) Transporting electric motor including loading/ unloading upto workshop and back to site. (c) Re-installing the same at the orignal locaition with proper alignmenent connecting and testing on load. (d) Replacement 2 Nos ball bearing for each motor of existing size/model. Make- SKF/NBC/TATA. (e) Replacement of winding terminal plate with brass stus,/nut, bolt washer. NOTE: Quoted rates shall be deemed to include one year warranty for motors after rewinding and commissioning.
-Ditto- all as per item No 12 above but Motor 5 HP Capacity
S&F cast iron covers, circular, for overhead PVC / RCC water storage tanks of any size, with MS strip / flat iron framework, with all necessary fixing and locking arrangements, nuts, bolts, washers, all as per BMC standards, with a shop coat of primer, including all necessary scaffolding / staging as required to cater at heights, taking out and disposing off old PVC covers, making any required addition / alteration to the tank for fixing of new CI covers, etc. complete all as specified, as directed by the Engineer-in-charge. (weight of tank cover not less than 10 KG). Make : As per sample
M & L for preparation of old painted / unpainted surfaces of any description, including taking out of parts / components under painting (if required) from any position / location as listed hereinunder and applying one coat of epoxy paint (with colour code maintained as per relevant IS) including marking with flow directions (of approved colour) complete all as specified and as directed by the Engineer-In-Charge. (a) Induction motors 15 HP/20 HP - 03 Nos. (b) Filteration plant 10,000 GLNs/Sec - 01 No. (c) Electric motor 5 HP - 01 No. (d) Sluice valve 100 mm dia. - 03 Nos. (e) Sluice valve 80 mm dia. - 03 Nos. (f) Electric Panel Board - 02 Nos
Supply only Calcium based granular disinfectant for drinking water treatment having 60% to 70% chlorine content in granular, sealed/ packed in 45 Kg drum.(Free from toxic constituent) all as required and directed by Engr-in-charge. Make- Purichlor/Declibac/potter & watts or other equivalent make.
Supply, fixing, jointing and testing of 80 mm, CI Sluice Valve heavy duty PN 1.6 with iron wheel head jointing, coupling both ends for cast iron pipes including nuts, bolts, rubber gaskets etc including taking down old unserviceable sluice valves complete all as specified and directed . Make : Kirloskar / leader /Kartar/Racold
-Ditto- all as per item No 17 above but 100 mm bore
M & L in replacement of PVC Service Water Tank including tank nipple, bends, sockets complete all fitting required at site all including taking down the existing tanks as specified and directed by Engineer-in-Charge of 500 Ltrs capacity. Make : Sintex/Sharp/Rotex/Infra
-Ditto- all as per item No 19 above but 1000 Ltrs capacity.
-Ditto- all as per item No 19 above but 2000 Ltrs capacity.
Taking up or down steel water tubing of upto 80 mm bore and connections including cleaning and setting a side for refixing, etc complete all as specified and directed by the engineer-in-charge.
Supplying, laying, connecting and testing of GI tubing medium grade of 25 mm dia with and including all fittings such as bends elbows, tees, short pieces, connectors, check nuts, diminishing pieces, caps and plugs, unions,etc fixed complete laid in trenches / along the walls / ceilings / floors / ducts / on pillar post all as specified and directed by Engineer-in-charge. Make: Jindal, TATA, Swastik,
All as per item No 23 above but 40 mm dia.
All as per item No 23 above but 65 mm dia.
All as per item No 23 above but 80 mm dia.
Taking up old CI/DI pipe upto 100 mm bore and connections including cleaning and setting a side for refixing, etc complete all as specified and directed by the engineer-in-charge.
M&L DI pipe 80 mm bore with spigot & socket ends centrifugally cast class K-7 in any length laid in trench including rubber joint (tyton joint) as required as directed by Engineer-in-charge. Make :
All as per item No 28 above but 100 mm dia. Note for Item Ser No 23 to 29 : Excavation, returning filling and removal of surplus soil shall be measured and paid separately under respective item of schedule "A".
Excavation in trenches not exceeding 1.50 m wide and n.exc 1.5 m in depth for foundation of poles, cable etc, not exc 10 sqm on plan and getting out in soft/loose soil including taking out brick protection etc complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified and directed.
Removing excavated materials (soils) not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed.
M & L for sand cushioning by spreading in trenches crushed stone by gently by punning down manually as in cable protection all as specified and as directed by Engineer -in-charge.
M&L for DI fittings of class K-12 such as bends , collars, caps, plugs, connecting pieces any type upto 150 mm dia complete all as specified and directed.
M & L for dismantiling the existing valve chamber of size 900 X 900 X 900 mm including necessary earth work in any type of soil, PCC foundation D-2 1:3:6 in base concrete, brick work in CM 1:6 with 10 mm thick plaster internally and 15 mm thick externally in CM 1:4, 6 mm thick MS cover with hinges and locking arrangement fixed to angle iron frame made-out of 40 X 40 X 6 mm MS angles complete with 2 coats of synthetic enamel paint over one coat of red oxide zinc chrome primer on all metal works including necessary excavation earth work all plastered surfaces of valve chambers shall be provided complete all as specified and directed by Engr-in-Charge.
M & L in replacement of run lead joint for CI Spigot and socket 80 mm bore pipes and fittings complete.
-Ditto- all as per item No 36 above but 100 mm dia.
M & L in replacement of rubber gasket joint of the size 80 mm size for CI flanged type pipe including nut, bolt, washer complete all as specified and directed .
-Ditto- all as per item No 38 above but 100 mm dia.
S & F in repairs Gun metal gate or globe valve 40 mm dia, confirming to IS-778, ISI marked, with iron wheel head screwed at both ends for iron pipes or ferrule and fixing including necessary fittings like unions, check nuts, etc. and any addition / alteration required for threading and fixing complete all as specified and as directed by the Engineer-In-Charge.
-Ditto- all as per item No 40 above but 25 mm dia.
S&F in repairs of cast iron flanged ends sluice valve suitable for 100 mm dia pipes conforming to IS - Class PN - 1.0 with MS nuts, bolts, washers etc, as approved and testing complete all as specified and as directed. Make :- KIRLOSKAR/KARTAR/ LEADER/VENUS/Racold
S & F in repairs float ball valve assembly 20 mm bore , high pressure grade, with polythene float, fly nuts, screwed to GI pipe or brass ferrule, CI fittings viz. nipples, check nuts, reducers, elbow, sockets, etc. fixed complete all as specified and as directed by the Engineer-in-charge.
-Ditto- all as per item No 43 above but 25 mm bore
-Ditto- all as per item No 43 above but 40 mm bore
Drilling and taping cast iron water mains (in position) for branch connections 15 mm bore of the internal dia including ferrule and required fittings all as specified and directed.
-Ditto- all as per item No 46 above but 20 mm bore
Taking up or down steel water tubing 15 mm bore and connections including cleaning and re-fixing if found serviceable or removal unsv pipe to store complete all as directed.
-Ditto- all as per item No 48 above but 20mm bore
-Ditto- all as per item No 48 above but 25mm bore
-Ditto- all as per item No 48 above but 40mm bore
-Ditto- all as per item No 48 above but 50mm bore
M & L for PCC 1:2:4, type B-1, (using 20mm graded stone aggregate) as in foundation for pump sets and blocks including necessary form work complete all as specified and directed.
Supply and fix in repairs Mild steel type 'C' Channel made of any angle iron of suitable size for pump foundation frame of any size suitable for site by welding including all necessary nuts, bolts, washer complete all as specified and as directed.
Supply and fix in replacement ladder height 10 feet max, steps on every 01 feet made of angle iron of size 50x65x5 mm thick for sump complete all as specified and directed.
M& L for attending day to day complaint of minor nature including replacement of fittings such as elbow,socket,tee etc and deposting the complaint slip in complaint cell after user signature complete as per directed by engineer in charge.
M&L for provn of Earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the plate not less than 1.5M below normal GL, connected to Galvanized earth strip 32x6mm upto 7.5 mtr with protection pipe by means of bolts, nuts, check nuts & washers of GI or steel incl excavation in any type of soil, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 40mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia medium. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I 2009 specification complete all as directed
S&F GI strip size 32 x 6 mm all as directed including welding brazing and taking down of old GI strips as required at site
Supply and Fix in repairs Change Over switch TPN 400 Amps 415 Volt in open construction, panel mounted type with base plate for mounting in panel, including taking down of old Change over switch and reconnecting the cables with proper glands. Make : L&T/Havells/Legrand/Stranded
S & F in repairs foot valve of size 80 mm dia cast iron body, ball type, with flanged and drilled ends and synthetic rubber coated MS ball, conformimg to relevant IS, ISI marked, including all joints, gaskets, bolts and nuts, washers, including taking up/down old unserviceable valves from any position and any addition/alteration for fixing required complete all as specified and directed by the engineer in charge. Make : Kirloskar or equivalant or as approved by GE.
S&F in repairs industrial type pressure gauge made out of SS 304 material, SS sipon shall be factory insulated with closed cell elastomeric insulation in tubing form, pressure gauges shall be factory fitted with a ball valve complete all as specified and directed.
S&F in repairs Gun Metal Air Release Valve of size 15mm bore, complete all as specified and directed.
S & F in repairs Perforated Brass Threaded End cap size 15 mm dia for over flow pipe of water tank as per BMC standard including all fittings like GI Nipple, Bend, Elbow, Tee, Socket etc complete all as specified and directed.
S&F in repairs cast iron water meter of size 100 mm class B flange type conforming to IS-2373 all as specified and as directed. Make : Kranti/Capston/ Dashmesh
M & L in repair MS cover in repair suitable for existing size with hinges and locking arrangement fixed to angle iron frame made-out of 40 X 40 X 6 mm MS angles with locking arrangement complete with 2 coats of synthetic enamel paint over one coat of red oxide zinc chrome primer on all metal works including necessary excavation earth work all plastered surfaces of chambers complete all as specified and directed by Engr-in-Charge.
Manning & Operation of Central AC Plants [Installation consisting of AC plant with chilled water system 78 TR capacity having 03 Nos compressors each of 39 TR capacity (02 Nos working at a time and 01 No. standby) with all connected equipments and machineries round the clock through out the month in two shifts (including Sundays and Holidays) by employing one operator cum AC machanic per shift of eight hours including carrying out routine maintenance and upkeeping the Installation / AC Plants in operation condition complete in all respects as specified and directed :- Location : P-47,P-48 at NAD (Trombay): (i) 1st shift - 0600 hrs to 1400 hrs (ii) 2nd shift - 1400 hrs to 2200 hrs
Manning & Operation of Central AC Plants [Installation consisting of AC plant with chilled water system 22 TR capacity having 03 Nos compressors each of 11 TR capacity (02 Nos working at a time and 01 No. standby) with all connected equipments and machineries through out the month in two shifts (including Sundays and Holidays) by employing one operator cum AC machanic per shift of eight hours including carrying out routine maintenance and upkeeping the Installation / AC Plants in operation condition complete in all respects as specified and directed :- Location-:P-43,P-44,P-45 at NAD(Trombay): (i) 1st shift - 0600 hrs to 1400 hrs (ii) 2nd shift - 1400 hrs to 2200 hrs Notes for ITEM NOS 66 TO 67 :- Quoted rates shall also be deemed to include the following elements:- (i) To provide uniform, tools & plants, safety means like gloves etc to the employees and also alternative employee (reliever) for Manning and Operation of AC Plants/Installation so that the other employees can avail the facility of weekly leave etc. (ii) To keep the AC Plant Room & allied area in clean and tidy condition during the operation period. (iii) To carryout the routine maintenance, minor repairs, oiling, greasing and to rectify the minor defects to keep the plants / Installation in serviceable condition all as directed by the GE and Engineer-in-Charge. However, the major repairs, replacements, overhauling, gas charging, topping-up oil etc are not included in the scope of the above items. (iv) To keep necessary documentation duly signed by all the concerned. (v) To hand over the entire plant in serviceable condition at the time of completion. (vi) Contractor shall submit the details of payment of wages for staff employed through Aadhaar linked bank accounts for payment purpose.
Taking down copper/ aluminum point wiring (Light/Fan/Socket or power) complete including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces to walls floors etc complete all as directed.
Taking down complete main switches/DBs with enclosure and its components of any size and capacity etc complete all as specified and directed.
M & L for point wiring complete with proper colour coding using, 1100 Volts grade, 1.5 Sqmm, PVC insulated FRLS, unsheathed wire with multi stranded copper conductor confirming to IS-694, Part II, ISI marked drawn in and including PVC casing caping (minimum 25mm width) fixed on the surfaces of wall, ceiling etc with all accessories, fittings, PVC junction boxes etc, sunk pressed steel boxes not less than 2 mm thick, 50 mm deep terminal boxes covered with 3mm thick plastic laminated sheet top cover fastended with chromium plated brass screws, also including 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts multistranded copper conductor green colour as continuous earth wire connected to common earth dolly all as specified and directed for following items-: (a) one light point /fan/bell point controlled by one one way switch
-ditto- all as per item No.70 above but for One 2pin/3 pin socket outlet 5 Amps on same board
-ditto- all as per item No.70 above but for One 2pin/3 pin socket outlet 5 Amps on independent board
M&L for point wiring using proper colour coding with 1100 Volts grade, 2.5 Sqmm PVC insulated, FRLS, unsheathed, wire confirming to IS-694, Part-II, ISI marked with multistranded copper conductor drawn in and including PVC casing caping (minimum 25mm in width) fixed on the surfaces with all accessories, fittings, PVC junction boxes etc, sunk pressed steel terminal boxes not less than 2 mm thick, 50 mm deep, covered with 3 mm thick plastic laminated sheet top cover fastened with chromium plated brass screws, also including 2.5 Sqmm, PVC insulated, FRLS, unsheathed, multistranded, copper conductor 1100 Volts grade, green color, continuous earth wire connected to common earth dolly for 15 Amps, 3 Pin, socket outlet independent, complete all as specified and directed.
Supply & Fix Bell push, flush type, 5 Amp, 230 Volts, complete all as specified and directed.
S&F Switch Piano 5 Amps, 250 Volts, one way, flush type, complete all as specified and directed.
S&F Switch Socket combination 2 in 1 , 5 Amps, flush type, 5 Pin, 240 Volts, complete all as specified and directed.
S&F Switch Socket combination 2 in 1 , 5/15 Amps, flush type, 6 Pin, complete all as specified and directed.
S&F ceiling rose three terminal, 230 Volts PVC / Polycarbonate body, complete all as specified and directed.
S&F fan regulator, electronic stepped (5 step), 230 volts, 100 watt, flush type and connecting-up, complete all as specified and directed.
Taking down carefully and refixing in position after repairs to existing flameproof LED lamp fitting including S & Fix in replacement unserviceable pin/ screw type LED 60 watts all as directed and specified by Enginer in charge
Taking down carefully and Refixing in position after repair to existing LED tube light fitting any watt any type, complete all as specified and directed
S & F in repairs LED high bay fittngs of 120 Watts, IP 66 including providing hooks/clamps and steel conduit of suitable size as down rod for length up to 1.5 metre including taking down rod unserviceable light fitting complete all as specified and directed by Engr-in - charge. Make : Bajaj / Philips/Havells
S&F in repairs Ultra bright glass LED tube rod 18/20 Watts, 230 Volts, with high efficency suitable for T8 fitting with G13 lamp holder. Make : Bajaj/Philips/Jaquar/Wipro
S&F in repairs decorative box type fitting prewired Regal batten for LED light fitting 16/20 Watts, 230 volts, including PVC Mounting blocks - 2 Nos, including connecting up with 1.5 Sqmm White colour PVC insulated three core flexible multistranded copper conductor for connecting with ceiling rose. Make : Bajaj/Philips/Jaquar/Wipro
Supply and fix in repairs SUPRA NEO-I LED Lights fittings 35 W wellglass in PDC Aluminium housing with finless design and exellent thermal management offering high durability and superior performance with energy saving and having efficacy of 110 Lm/W with provision of suitable fixing arrangement such as MS clamps,nut,bolts etc. Make : Bajaj/Philips/Jaquar/Wipro
Supply and fixing in reparis of LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including provision with three core flexible copper conductor cable of suitable size and PVC square blocks complete all as specified and directed. Make :- BAJAJ/ PHILLIPS/ JAQUAR/ WIPRO
S&F in Repairs SKY LUX efficient LED (white)recessed 4x1 luminaire to enhance the delight of occupants with comfortable exprience through its classic design & glare free soft illuminations mounted direct/indirect architectural luminaire including connecting 1.5 Sqmm white colour suitable for false ceiling fixing arrangement all as specified and directed in EIC. The fitting shall conform to cat No BZRSLL 36W GZ1 WH of Bajaj or equivalent Philips/ Crompton.
Supply and fix decorative recessed type LED light fitting 35/36 watt (size 2'x2') and including driver unit, including provision of 3 core copper flexible cable 1.5 Sqmm from ceiling rose to connector, including making addition/altn to existing false ceiling and providing of false ceiling sheets, aluminium frames including fixing arrangements complete etc. Make :- BAJAJ/ PHILLIPS/ JAQUAR/ WIPRO
Taking down and refixing any type of DB and including cutting chases in wall, concealing DB in wall, making good the disturbed surfaces and making all connections, complete all as specified and directed
S & F MCB DB, 12 way, SPN, double door, 240 Volts and including cutting chases in wall, concealing DB in wall, making good the disturbed surfaces and making all connections, complete all as specified and directed. Note: Quoted rate shall also be deemed to include for provision of copper bus bar of 200 Amps rating.
S & F MCB DB, 8 way, SPN, double door, 240 Volts and including cutting chases in wall, concealing DB in wall, making good the disturbed surfaces and making all connections, complete all as specified and directed. Note: Quoted rate shall also be deemed to include for provision of copper bus bar of 200 Amps rating.
S & F MCB DB, 4 way, SPN, double door, 240 Volts and including cutting chases in wall, concealing DB in wall, making good the disturbed surfaces and making all connections, complete all as specified and directed. Note: Quoted rate shall also be deemed to include for provision of copper bus bar of 200 Amps rating.
S & F MCB TPN 63 to 100 Amps, 240 / 415 Volts, 50 Hz, 10 KA Breaking capacity complete all as specified and directed.
S & F MCB SPN 40 Amps, 240 / 415 Volts, 50 Hz, 10 KA Breaking capacity complete all as specified and directed.
S & F MCB, SP, 05 to 32 Amps, 240 Volts, 10 KA Breaking capacity, C-series, complete all as specified and directed.
S & F MCB SPN 32 Amps, 240 / 415 Volts, 50 Hz, 10 KA Breaking capacity complete all as specified and directed.
Disconnecting the electric connecting and screwing and taking down the unserviceable sub main wiring and M&L for sub main wiring with two single core 4.0 Sqmm PVC insulated FRLS multistranded flexible copper conductor cable 660/1100 volts grade down in through non metalic PVC casing caping with and including PVC insulated 4.0 Sqm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly all as specified and as directed Note : 1. Two runs of cable, one run of earth wire, one run of PVC casing capping will be measured and paid one unit.
M&L for sub main wiring with two single core 2.5 Sqmm PVC insulated FRLS multistranded flexible copper conductor cable 660/1100 volts grade down in through non metalic PVC casing caping with and including PVC insulated 2.5 Sqm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly all as specified and as directed Note : 1. Two runs of cable, one run of earth wire, one run of PVC casing capping will be measured and paid as one unit
M&L for sub main wiring with two single core 6.0 Sqmm PVC insulated FRLS multistranded flexible copper conductor cable 660/1100 volts grade down in through non metalic PVC casing caping with and including PVC insulated 6.0 Sqm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly all as specified and as directed Note : 1. Two runs of cable, one run of earth wire, one run of PVC casing capping will be measured and paid one unit
S& F in repair of GI steel tubing medium grade 40mm dia and length up to 1.5 meter bent to shape of offset angle upto 45degree for fixing of security /street light fittings including MS clamps made of 32mm x5mm flat iron, nuts , bolts, etc all as directed by Engineer in charge.
S&F in repair of FRP looping box of size 155x210x92 mm with connector, MCB 6 Amps, Din Rail, GI clamps made out of GI flat of size 25mm X 3 mm channel including making connections all as specified and directed by Engineer -in -Charge. Make : Cat No KF 1616 B of Hansel or equivalent of sintex/Standard.
supply & lay 3 Core 1.5 Sq mm size multistranded copper conductor PVC unsheathed 650 / 1100 Volt Grade As per IS 694 with and including 20 mm dia PVC conduit and passing through PVC conduit with necessary saddle, clamps, bolts & nuts, all For interconnection of cable looping box to Street Light Fitting, Post Top Lantern etc including taking down existing cable & PVC Conduit All as Directed.
M&L for Multistranded Copper Conductor cable of 3 Core 1.5 Sq mm size drawn through steel tubular poles for interconnection of cable looping box to Street Light Fitting, Post Top Lantern etc taking down old unsv cable all as Directed.
Supply and fix in repair street light/ building security light fitting LED 60 watts with Pressure die cast housing wih toughened glass and individual LED's with secondary optics & IP66 protection etc all as directed by Engineer in charge. Make : Cat no - BRTFG 60W LED V3 of Bajaj or equivalent in Havells / Philips
S&F in repair of building Security light fitting 35 Watt made up of pressure die cast aluminium body with mid power LED as lighting sources and PC cover having top opening separate driver compartment with IP66 protection and impact resistance of IK07including fixing arrangements and taking down old rusted bracket fittings complete all as per directed by Engr- in – charge. Make :- BAJAJ/ PHILLIPS/ JAQUAR/ WIPRO/ CROMPTON
Taking down carefully ceiling fan, exhaust fan, wall / pedestal fan of any make and any sweep and dismantling of blades canopy down rod etc & remove to store for repair. & Refix the same including provision of 3 core 1.5 sq mm copper flexible cable from ceiling rose to connector of suitable length. Note:(i) The representative of the contractor shall report to Engineer-in-charge/JE on daily basis to carry out repairs to fan and the defects should be rectified on the same day.
M&L for Opening of body cleaning of slots of following fans, rewinding by super enamelled copper insulated wire as per existing gauge, varnishing, heating assembling and testing complete all as directed by Engineer-in-Charge. Note - Spares such as Bearing, Capacitor, Capacitor Clamp, Rubber insulator will be measured and paid seperately under respective item of this schedule.
Ceiling fan 1200 / 1400 mm Sweep.
Exhaust Fan,Pedestal fan,wall fan, table fan 300/400 mm Sweep.
Exhaust Fan, Pedastal fan,wall fan, 450/600 mm Sweep.
Painting only of ceiling fan,exhaust fan,wall fan,pedestal fan of any size and type, scraping out of old paint filling of cavities with filler preparation of body and cleaning of dust etc Painting by Spray with first Quality Paint complete all as specified and directed.
Overhauling of Ceiling Fan, Exhaust Fan, Wall Fan,Table fan,Pedestal Fan any Make & any Sweep including dismantling/opening of body, cleaning of body, oiling, greasing & reassembling complete, replacing of split pin, nut , bolts etc and testing complete all as directed Note : Spares shall be measured & paid separately for supplied only under respective items of this schedule.
Supply only capacitor up to 2.5 Mfd
Supply only capacitor Clamp with Connector as per Sample
Supply onlyRubber Insulator sutiable for any type of Ceiling Fan.
Supply only Mild steel down rod 600 mm Long with Clamp nut bolts & split pin as per sample/ existing size
Supply only Mild steel down rod with Clamp nut bolts& split pin for 900 mm long as per sample/ existing size
Supply only Ball bearing sutiable for any type of fans
Supply only Gun Metal bush as per sample sutiable for any type of fans
Supply only Mild steel shaft as per sample / existing size for any fan
Supply only Ceiling Fan Blade suitable for 1200/1400 mm sweep as per sample/ existing size.
M & L for Flame proof Light point wiring with FRLS PVC insulated unsheathed 1100 Volts grade single core multistranded copper conductor cable 1.5 Sqmm drawn in and including Stove Enamlled steel conduit and accessories such as bend tee elbow(two way, three way,four way) junction box with cover fixed on wall / ceiling etc with neccessary fixing accessories complete for all as directed
S&F in repair flame proof WP rotoy switch/Isolator 230 volt 10 A double pole ON / OFF with cable termination box in LM6, including anchor fasteners complete for all as directed
Supply and fix in repairs flame proof LED Light fittings CIMFR certified LED flame proof wellness in die cast AI housing with heat resistance toughened glass GLAZE PRO LED Lights fittings 30 W . Recommendation for gas/Vapour group of IIA and IIB and Zone 1 & 2 IP65 protected, confirm to CAT No FWL1315-30-CDL of crompton or equivalent from Philips/Bajaj as approved by the GE.
M & L for point wiring with PVC insulated FRLS unsheathed 1100 Volts grade single core multistranded copper conductor cable 1.5 Sqmm drawn in and including PVC casing-caping, fixed on wall / ceiling with all accessories, fittings, PVC junction boxes etc, with suitabe sunk pressed steel boxes for modular fittings not less than 1.6 mm thick, etc with necessary fixing accessories and earth continuity conductor cable of 1.5 Sqmm size connected to common earth and earth dolly including 1.6 mm thick pressed steel terminal boxes concealed in wall all as specified for one light / fan / bell point controlled by one switch.
-Ditto- all as per item No 113 here-in-before but for one 5A 2pin/3pin socket out let multipurpose on the same board with other switches.
-Ditto- all as per item No 113 here-in-before but for one 5A 2pin/3pin switch socket out let multipurpose on independent Board.
All as per item No. 113 above but wiring complete with 2.5 Sqmm for 3 pin 15A socket multipurpose on independent board
S&F modular type 6A one way SP switch 1 module confirming to IS: 3854-1997 with fingure proof terminal complete all as specified and directed.
S&F modular type 2/3 pin combined shuttered type 6 Amps socket 2 module conforming to IS: 1293-2005 complete all as specified and directed.
S&F modular type 2/3 pin combined shuttered typr 16 Amps socket 2 module conforming to IS: 1293-2005 complete all as specified and directed.
S&F modular type 16 A one way SP switch 1 module confirming to IS: 3854-1997 with finguer proof terminal complete all as specified and directed.
S&F modular type 120W step fan regulator of 2 module size conformng to IS: 11037-1984 complete all as specified and directed.
Material and labour for carrying out vaccum test, pressure test and detecting leakage and rectifying the leak and charging the refrigerant (R-22) complete for Tower/split/window type A/C of any capacity Note : (i) Job includes dismantling equipment from any site, height and transporting to workshop if necessary and reinstalled in situ and testing (ii) Above Job to be guaranteed for minimum one year
--ditto -- all as per item No 122 but for water cooler of any capacity
--ditto -- all a s per item no 122 above but suitable for refrigertor/ deep freezer of any capacity
M & L for repairs to base/body/stand of water cooler of any capacity by cutting out rusted portion, replacing with new M.S sheet of existing gauge including finishing wall surface and painting complete body of water cooler of any capacity Noe :- Job includes dismantling equipment transporting to workshop and back included' re-installing in situ.
Supply and fix in repairs chasis made out of 2mm thick MS sheet suitable for 1.5 TR/ 2.0 TR capacity window type AC including dismantling accessories and re-installing on new chasis, painting complete body and required parts including connection with new wiring etc all as directed
Material and labour for servicing of A/C window type or split type A/C, tower AC of capacity 1.5/2/2.5 TR including washing with sodash the cooling coil/condensor coil base body drying with air blower checking complete wiring testing and re-installing in situ and testing the unit.
M & L for dismantling unserviceable compressor from the window type AC, Split type A/C 1.5 TR/ 2.0 TR capacity from any location , supply and fix new hermatically sealed compressor unit , assembling, brazing pressure/vaccum testing initial oil charging, gas charging,reinstalling A/C in situ and connecting to electric supply and testing all as directed and specified. Make : Voltas/Carrier/Kirloskar /bluestar Note : (i) Job including removing A/C from any site/height/location (ii) Transporting A/C unit to repair workshop and back to site (iii) Loading/unloading etc
--ditto -- all as per item 128 above but suitable for refrigerator 165 to 320 ltrs capacity
--ditto -- all as per item 128 above but suitable for water cooler 40 t0 150 ltrs capacity
--ditto -- all as per item 128 above but suitable for deep freezer of 200 to 500 ltrs capacity
Supply and fix in repair AC fan motor for window/split type A/C of 1.5/2 TR ,Tower AC 2.5 TRcapacity single phase 230 volt 50 HZ complete with fan blade/blower including any addition/alteration to suit new fitting of motor.
--ditto -- all as per item No. 132 but for Water cooler any capacity
--ditto -- all as per item No. 132 but for deep freezer any capacity
Supply and fix in repair Relay for A/C split/window type,Tower AC
Supply and fix in repair Relay for WATER COOLER/DEEP FREEZER
Supply and fix in repair Thermostat for A/C 1.5 TR/2 TR,Tower AC
-ditto- all as per item No 137 but for water cooler of any capacity
Supply and fix in repair Air filtter for window type/split type AC, Tower AC as per sample
Supply and fix in repair Starting capacitor 80-100 mfd 220 volt 50 HZ
Supply and fixing in repair of Running capacitors of capacity 36 MFD 220 volt 50Hz complete all as specified and directed by Engr-in-Charge
-ditto- all as per item No 141 but 6 MFD
-ditto- all as per item No 141 but 4 MFD
-ditto- all as per item No 141 but 45 MFD
Supply and fix Starting capacitor of capacity 120 - 150 MFD for 2 TR, 2.5 TR capacity
Supply and fix in repair 3 core 4 sqmm flexible cable PVC insulated sheathed copper 1100 volts grade.
Supply and fix in repair 3 core 2.5 sqmm flexible cable PVC insulated sheathed copper 1100 volts grade.
Supply and fix in repair earthed metal clad socket outlet with earthed plug top 20 Amps capacity with sheet metal enclosure and one 20 Amps MCB SP all as specified and directed.
M & L for power point wiring with PVC insulated sheathed copper wire 4 Sqmm size 1100 volts grade IS-654 in and including PVC casing and capping with all accessories including one run of 2.5 Sqm earth lead wire all as directed and specified.
Supply and fix in repair copper tube of size 6mm bore including brazing etc with rubberised insulation and tape suitable for supply pipes for air-conditioners complete all specified by Engineer -in-charge
Supply and fix in repair copper tube of size 10 mm bore including brazing etc with rubberised insulation and tape suitable for supply pipes for air-conditioners complete all specified by Engineer -in-charge.
Supply and fix in repairs 8mm dia hand shut off valve
Supply and fixing in repair and testing fan blade of motor for water cooler of 80/100/120/150 Ltrs capacity including removing old fan blade.
Supply and fixing in repair and testing fan blade suitable for window type Air conditioner of 1.5 Ton/2 Ton capacity including removing old fan blade.
Supply and fix in repairs front grill as per sample suitable for window type AC 1.5 TR/2 TR capacity.
Supply and fixing in repair of blower drum suitable for window type Air concitioner of capacity 1.5Ton /2TON.
Supply and fix in repair stainless steel tank of capacity 40 ltrs capacity water cooler of existing size shape
All as per item No. 157 but 80 ltrs capacity
-All as per item No. 157 but 120 ltrs capacity
Supply and fix in repair waste water tray suitable for single/double tap with waste hose.
Supply and fix in repair PVC float valve wih PVC ball suitable for 15mm dia
Supply and fix in repairs bibtap push type stainless steel 15mm dia
Supply and fix in repairs gun metal gate valve with iron wheel head screwed both ends for iron pipe of size 20mm.
Supply and fix in repairs gun metal gate valve with iron wheel head screwed both ends for iron pipe of size 15mm.
Supply and fix in repairs remote sensor kit with Manual control pendent suitable for split type A/C,Tower AC 1.5 TR to 2.5 TR capacity work on 230 volt SP 50 HZ
Supply and fix base tray suitable A/C 1.5/2 TR made out of 2mm thick of existing size and shape including painting one coat zine chrome red oxide and two coats of synthetic enamelled paint
Supply and fix in repairs ventury and blower drum suitable for A/C window type 1.5 TR/2 TR as per existing model, size, and shape
Supply and fix in repairs condensor coils suitable for 1.5 TR to 2.5 TR capacity including dismentling old one brazing, testing, leakage rectification all as directed.
Supply and fix in repairs cooling coil suitable for 1.5 TR to 2.5 TR A/C of existing model including taking out old defective coil, brazing work, brass charging to full pressure
Supply and fix in repairs thermal over load relay 415 volts 66 - 110 Amps rating MMX R-4 model
Supply and fix in repairs thermal over load relay 415 volts 32 - 50 Amps rating MMX R-4 model
M&L in repair for wall mounted powder coated MS bracket suitable for 1.5TR/2TR Split type AC, Towre AC 2.5 TR out door unit
M&L for repair of rubberised insulation and tape for copper tubes of size 6mm/10mm.
Shree Ayyappa Engineering
shubham construction
sapana enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .