Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-AOC | L1 | Accepted-AOC Quoted rates of lowest bidder found reasonable hence accepted | |
| 2 | L2₹8.3 L+₹33,817.79 (4.27%)Rejected-AOC KHARSA JANG PO JANG DISTT TAWANG ARUNACHAL PRADESH | JANG | TAWANG | ARUNACHAL PRADESH | 790104 | L2 | Rejected-AOC Quoted rates are high hence rejected | |
| 3 | L3₹8.5 L+₹56,671.91 (7.15%)Rejected-AOC | L3 | Rejected-AOC Quoted rates are high hence rejected | |
| 4 | L4₹8.7 L+₹74,803.81 (9.44%)Rejected-AOC | L4 | Rejected-AOC Quoted rates are high hence rejected | |
| 5 | L5₹8.9 L+₹98,714.76 (12.5%)Rejected-AOC | L5 | Rejected-AOC Quoted rates are high hence rejected |
Tender Value
₹8.4 L
EMD Value
₹16,760
Closing Date
20 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Mr GURUDAS GOLDAR, AE (CIV)
AGE (I) TAWANG Pin- 900198 C/o 99 APO
REPAIR/MAINTENANCE TO LT OH LINE, LT CABELS, LT PANELS AND OTHER CONNECTED WORKS AT 106 FD WKSP, 384 ASC COY, 277 TRANSIT CAMP, B DET AMD MARATHA LI AND REPAIR/MAINTENANCE OF HEATING PLANT AND COOLING APPLINCES INSTALLED AT VARIOUS UNIT UNDER AGE(I)
2023_MES_599936_1
8568/AGE(I)/TWG OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
Tawang
REFER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
AGE (I) TAWANG
₹16,760
31 Aug 2023
31 May 2023
27 Jun 2023
31 May 2023
20 Jun 2023
13 Jun 2023
31 May 2023 - 6 Jun 2023
Amount
Dismantling and taking up or down old Unserviceable service cable and LT UG cable of any size complete all as specified and directed
Supply and Laying and connecting with appropriate lugs in replacement XLPE LT cable PVC insulated, heavy duty electric cables with Aluminum conductors,1100 volts grade, laid in trenches/on pole/in pipe /on wall ,using suitable clamps for fixing of cable complete all as specified and directed of cross-sectional area 10 Sqmm 2 Core.
All as per Item No 2 above but 16 Sqmm 2 Core.
All as per Item No 2 above but 25 Sqmm 3.5 Core.
All as per Item No 2 above but 35 Sqmm 3.5 Core.
All as per Item No 2 above but 50 Sqmm 3.5 Core.
Supply and laying or fixing or passing through pipe 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor served with inner shethering of PVC tape armoured with galvanised steel wire or tape and overall PVC shetered 10 Sqm 2 Core nominal cross section in sevice connection including taking down old unserviceable service wire complete all as specified.
Supply and laying or fixing or passing through pipe 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor served with inner shethering of PVC tape armoured with galvanised steel wire or tape and overall PVC shetered 16 Sqm 2 Core nominal cross section in sevice connection including taking down old unserviceable service wire complete all as specified.
Excavation in trenches, not exc 1.5m wide and not exc 1.5m in depth, for foundation, etc or for shafts, wells, cess-pits, menholes, pier holes, etc. not exc 10 sq m on plan and not exc 1.5m in depth and getting out in soft & loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, waterring and wall ramming in layers not exc 25 cm. for any type of soil complete all as specified and directed.
Removing excavated soil not exc. 50 m and depositing where directed at a layers not exc 25 Cm. above/below the starting point complete all as specified and directed.
Supply and laid in trenches double walled corrugated HDPE pipes of inner dia 38 mm and outer dia 50mm, as in cable protection work, complete all as specified and directed.
Supply and laid in trenches double walled corrugated HDPE pipes of inner dia 50 mm and outer dia 63mm, as in cable protection work, complete all as specified and directed.
Supply and fixing in replacement MCCB 4 Pole, 415 V, 160 Amps with breaking capacity 25 KA complete with all accessories complete all as specified and directed.
Supply and fixing in replacement MCCB 4 Pole, 415 V, 100 Amps with breaking capacity 25 KA complete with all accessories complete all as specified and directed.
Supply and fixing in replacement MCCB 4 Pole, 415 V, 63 Amps with breaking capacity 25 KA complete with all accessories complete all as specified and directed.
Materials and labour for earthing complete with galvanised steel earth plate electrode 60cmX60cmX6mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level)with top edge of the plate not less than 1.5 metres below normal groundlevel, connected to galvanised earth lead strip 32x6mm by means of volts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-5 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C-1 as in pit, 20mm dia GI pipe medium grade for watering pipe, 15 mm bore GI medium grade earth lead protection pipe, 50 mm thick RCC 1:2:4 type B-1 cover slab of earth pit reinforced with 8 mm dia TMT bars @ 10 cm C/C both ways and with handle made out of 10 mm dia bars, funnel, strainer,charcoal and testing on completion complete all as specified and directed.
Material and labour for continuity conductor or main earthing lead fixed to all on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 32x6mm galvanised iron strip
Material and labour of ACSR conductor of any type /size and any type/height of pole
Triming/choping and cutting of branches each tree of any grith which are coming across the over head line/ security light pole up to 3 meter all sides of the conductor span of LT over head libe, poles etc as required and removing the same from site of work completed all as directed by engr in charge
Material and labour for removal green vegetation and dressing around the plinth/ PCC hardstanding up to 1.5 mtr of sub station and 2/4 pole structure etc including disposal of vegitation material up to 50 mtr distanced from the site and levelling surfacing the ground all as specified and directed
Materials and labour for replacement of GI pipe light grade with all fittings complete grouted in ground all as specified for 50 mm bore of pipe laid in trenches/fixed with poles/laid in road/plinth/floor for protection of cable complete all as specified and directed.
Materials and labour for replacement GI pipe light grade with all fittings complete grouted in ground all as specified for 80 mm bore of pipe laid in trenches/fixed with poles/laid in road/plinth/floor for protection of cable complete all as specified and directed.
Dismantling of old unserviceable steel poles of any size after disconnecting power, keeping aside serviceable insulators, stays, clamps etc for reuse complete all as specified and directed.
Supply and fixing in replacement of steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-22 (8.5 metres Long) complete all as specified and directed.
Dismantling of old ACSR or AAC Conductor all as directed by the Engr-in charge.
Materials and labour for PCC (1:3:6) type C-2 using 40mm graded stone aggregates as in foundation filling and mass concrete (for foundation bed concrete in stays /poles or any other position as directed at site).
Materials and labour for PCC (1:2:4) type B-1 using 20 mm graded broken stone aggregate as in mass concrete in coping of existing and new PCC/steel poles etc complete all as specified and directed.
Materials and labour for Painting of Steel tubuler pole up to 9 mtr long by using Two coats of aluminium paint with one coat of red oxide primer including preparation of surface all as directed by the Engr- in-charge.
Supply and fixing in repair LT Over over head line phase seperator of any size (4 way) in between distribution span of LT over head lines all as directed by the Engr-in-charge.
Supply and fixing cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories, Outdoor type suitable for size 25 to 50 sqmm 3.5/ 4 Core.
All as per Item No 31 above but 70 to 120 sqmm 3.5/ 4 Core.
Supply and fix Off Load changeover switch side handle in sheet metal enclosure 415 V AC 50 Hz of Capacity 100 Amp 4 pole all as directed by the Engr-in-charge. Make : Havells, L&T and its equivalent
Dismantling air break gang operated switches vertical/horizontal mounted including insulators and operating mechanism for repair/ replacement all as directed by the Engr-in-charge.
Materials and labour for Air break, gange operated switch HT 11000 volts, Triple pole , mounted on insulators and steel frames with operating mechanism worked from ground level with operating rod, handle etc., for current rating upto 400 amps fixed on pole / structures complete all as specified and as directed by the Engr-in charge.
Supply and fixing for replacement of disc insulator, porcelain, vitreous, 145nm high and 225 mm dia ball & socket type, with tension clamp suitable for conductor single disc assy working pressure 11000 volts complete all as specified and directed.
Supply and fixing in repair aluminium lugs for 10 Sqmm size complete all as specified and directed.
All as per Item No 37 above but 16 Sqmm.
All as per Item No 37 above but 25 Sqmm.
All as per Item No 37 above but 35 Sqmm.
All as per Item No 37 above but 50 Sqmm.
Locating electrical fault in UG cable of any size and repair by using of suitable size of cable lugs and straight through joint and make the good disturbed surfaces all as specified and directed by Engr-in-charge. Note :- Cable joint kit, Earth work & Aluminium lugs will be measured and paid seperately in respective items.
M&L for servicing/cleaning of complete indoor/outdoor unit of split type air conditioner of 2.0 Ton capacity by means of adding cleaning solution of water.The cleaning of condensor and chiller tubes use of nylone brushes till the scaling is removed and ensuring its serviciblity by rectification/replacement of unserviceable parts and keeping the AC in good working condition. Note:- Supply of spares for replacenment will be measured and paid seperately under relevent items of Schh 'A'
All as per item No 43 here in above but Refrigerator/Deep freezer of any capacity
Taking out unserviceable compressor of any type of AC, from site and replacement of new compressor against repair of existing make, the compressor sealed unit in position, charging of refrigerant gas suitable type of required quantity, bracing of discharge and suction line and leak testing complete as directed by the Engineer-in-charge for Split Type AC 2.0 Ton capacity
All as per item No 45 here in after but Deep freezer of any capacity
All as per item No 45 here in after but refrigerator of any capacity
M&L Pressure testing / leak arresting , vaccumising with dry nitrogen gas / oil charging, incl replacing the unserviceable strainers and capillary tubes all as required testing complete for the Split Type AC 1.5/2.0 TR including transportation to workshop.
All as per item No 48 here in after but Deep freezer of any capacity
All as per item No 48 here in after but refrigerator of any capacity
M&L Gas charging with R-134a for Refrigerator/Deep freezer in position including leak testing to achieve desired suction pressure and temperature
M&L Gas charging with R-22a for split type AC in position including leak testing to achieve desired suction pressure and temperature
Supply only Condenser blower motor for Outdoor Split type type AC 1.5 / 2 TR capacity.
All as per item No 53 here in after but refrigerator/Deepfreezer of any capacity
M&L for servicing of complete indoor/outdoor unit of central heating system of capacity 100000 K Cal/Hrs complete by cleaning of ducts and servicing of blower/Burner etc and ensuring its serviciblity by rectification/replacement of unserviceable parts and keeping the heating system in good working condition.
M/S P W ENTERPRISES
M/S K D CONSTRUCTION
M/S KHANDU CONSTRUCTION
M/S RHEGON CONSTRUCTION
SHELLUNG CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .