| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.4 LAccepted-AOC 521 DR K L ACHAL VANSHI COLONY JAISALMER 345001 RAJ | JAISALMER | RAJASTHAN | 345001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹32.5 L+₹3.7 L (12.8%)Rejected-Finance | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹33.5 L+₹4.7 L (16.5%)Rejected-Finance JAISALMER | BARMER | RAJASTHAN | 344001 | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹34.4 L+₹5.7 L (19.7%)Rejected-Finance | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹36.0 L+₹7.2 L (25.2%)Rejected-Finance JAISALMER | JAISALMER | RAJASTHAN | 342310 | L5 | Rejected-Finance Not being lowest |
Tender Value
₹40.2 L
EMD Value
₹80,480
Closing Date
20 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Army Jaisalmer
GE Army Jaisalmer - 345001
SPL REPAIRS TO BLDG NO P-549-B AT CERTAIN UNIT AT MIL STN JAISALMER
2024_MES_643364_1
8356/23-24/E8
Open Tender
Civil Works
Item Rate
180 days
Jaisalmer
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Army Jaisalmer
₹80,480
Yes
27 Nov 2024
21 Feb 2024
22 Mar 2024
21 Feb 2024
20 Mar 2024
6 Mar 2024
Amount
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and n exceeding 1.5 m in depth and getting out in soft/ disintegrated rock complete all as specified & directed by Engineer-in-Charge.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soft/ disintegrated rock all as specified & directed by Engineer-in-Charge.
Removing excavated soft/ disintegrated rock to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by the Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premise complete all as specified and directed by Engineer-in-charge.
Demolition of cement concrete (un reinforced) in ground floors and pavings n.exc 15 cm thick (below or above ground level) & removing rubbish off from out side MD land all as directed by Engineer-in-charge.
M&L for 25mm thick PCC (1:2:4) type B-0 (using 12.5mm graded stone aggregates) as in flooring & finished the surface even & fair without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles laid over and including 15mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed by Engineer-in-charge.
M&L for glazed ceramic colour tiles 350x250mmx7mm/ 450X350X7mm thick, in vertical surfaces etc set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 10mm thick backing coat in CM (1:4) complete all as specified and directed by the Engineer in charge.
M&L for Machine cut kota stone slab flooring 16-22mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over and including screed bed 15 mm thick in CM 1:6 complete all as specified and directed by the Engineer in charge.
M&L Kota stone slab 16-22mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over and including backing coat 10mm thick in CM 1:4 complete all as specified and directed by the Engineer in charge.
Taking down cement plaster of any description on stone or brick walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engineer-in-charge.
M&L for rendering 15 mm thick plaster in cement mortar (1:6) on fair faces of brick work or concrete surfaces of walls and finishing the surface even and smooth without using extra cement all as specified and directed by Engineer-in-charge.
M&L for rendering 5 mm thick in CM (1:4) on fair faces of concrete surfaces as in ceiling finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for rendering 15mm thick in cement mortar (1:4) in two layers first coat 10 mm thick even and smooth without using extra cement and second 5 mm thick using water proofing compound @ 3% by weight of cement and finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge. Note :-WPC will be measured and paid separetly.
M&L for preparing new plastered or unplastered surfaces and applying three coats of white wash on walls complete all as specified and directed by Engineer-in-charge.
M&L for preparing new plastered or unplastered surfaces and applying three coats of white wash on ceiling complete all as specified and directed by Engineer-in-charge.
M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of cement base paint over a coat of primer complete all as specified & directed by Engineer-in-charge.
M&L for preparation of old plastered or unplastered surface of walls and applying one coat of white wash complete all as specified & directed by Engineer-in-charge.
M&L for preparation of old plastered or unplastered surface of walls and applying one coat of colour wash complete all as specified & directed by Engineer-in-charge.
M&L for preparation of old plastered or unplastered surface of ceiling and applying one coat of white wash complete all as specified & directed by Engineer-in-charge.
M&L for preparation of old plastered or unplastered surface of wall and applying one coats of cement base paint complete all as specified & directed by Engineer-in-charge.
M&L for preparation of old steel surface of any description, over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint (ordinary tint) complete all as specified & directed by Engineer-in-charge.
Taking down chowkhats or frame with shutters (w/o taking off shutters from the frame) n exc. 1.5 Sqm each complete all as specified & directed by Engineer-in-charge.
Taking down shutters of any description exc 1 Sqm but not exc 2 Sqm each complete all as specified & directed by Engineer-in-charge.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified & directed by Engineer-in-charge.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with single piece extruded PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement of single piece extruded PVC profile for top rail, lock rail and bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement complete all as specified & directed by Engineer-in-charge.
S&F pressed steel frames (size 105 x 60mm) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete all as specified & directed by Engineer-in-charge. Note :- Rate quoted by the Contractor shall deemed to inclusive of filling of pressed steel door frame with PCC (1:3:6) type C1 (using 20mm graded stone aggregate).
S&F 35 mm thick flush shutters, solid core construction, with block board core & plywood face panels, commercial type on both sides all as specified & directed by Engineer-in-charge.
S & F, 35 mm thick Second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc size of members of shutters as specified in SSR Part-I, section 8, clause 8.24 (a) complete all as specified & directed by Engineer-in-charge.
M&L for preparing new or previously untreated wood and wood based surfaces of any description otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint (Ordinary tint) over a coat of pink primer complete all as specified & directed by Engineer-in-charge.
S&F 150 mm size aluminium anodised barrel tower bolts of extruded section all as specified & directed by Engineer-in-charge.
S&F in repair, 150 mm size aluminium handle, cast type, anodiesed complete all as specified & directed by Engineer-in-charge.
S&F, 100mm size, butt hinges, medium weight, cold rolled mild steel including necessary welding if required all as specified & directed by Engineer-in-charge.
S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy all as specified & directed by Engineer-in-charge.
S&F 200 mm size aluminium anodised barrel tower bolts of extruded section all as specified & directed by Engineer-in-charge.
S&F, glavanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aparture 1.18mm and fixed with tinned tack or galvanised wire stapples complete all as specified & directed by Engineer-in-charge.
S&F, 3mm thick, sheet glass ordinary quality and glazing with oil putty in squares not exceeding 0.50 sqm in each panes and including hacking out old broken glass of any thickness size, quality or description from steel/wooden frames complete all as specified & directed by Engineer-in-charge.
M&L for welding in repairs exc 2.5cm but not exceeding 5cm in length (thickness of metal to be welded not exc 6mm) including cleaning preparing the surface and holding the member in true position complete all as specified and directed by Engineer in charge.
M&L for preparation of new or previously untreated steel surface of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red- oxide, zinc chrome primer complete all as specified & directed by Engineer-in-charge.
S&F in repair 15mm dia bib taps cast copper alloy chromium plated with crown or capstan head, screwed down, high pressure screwed for iron pipe complete all as specified & directed by Engineer-in-charge.
S&F in repair 15mm dia pillar taps cast copper alloy with capstan head chromium plated screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts screwed for iron pipe complete all as specified & directed by Engineer-in-charge.
S&F in repair 15mm dia stop valves fancy type cast copper alloy chromium plated screwed down high pressure with crown or capstan head screwed both ends for iron pipe complete all as specified & directed by Engineer-in-charge.
S&F in repair 10 ltrs capacity PVC low level flushing cistern with inlet, ball valve, float, handle including fitting and fixtures and taking down the old damaged cisterns and providing connections to WC and flush pipe without any damage to the existing fittings complete all as specified & directed by Engineer-in-charge.
S&F in repair 600 mm long PVC connection pipe of 15mm bore with PTMT nut at both ends complete all as specified & directed by Engineer-in-charge.
S&F in repair CP grating (with & without hole) for Nahani trap and floor trap of size 100 mm dia fixed complete all as specified & directed by Engineer-in-charge.
S&F in repair brass chromium plated shower rose with swivel joints 125mm dia with 18mm dia chromium plated pipe complete all as specified & directed by Engineer-in-charge.
S&F in repair vitreous china squatting pan orissa pattern complete of size 580 x 440 mm white with integral foot rest and making good to the floor complete all as specified & directed by Engineer-in-charge.
S&F in repair Vitreous china wash down water closet pan(Pedestal pattern), white (EWC) with necessary P/S Trap and fixed in repairs including jet spray and seat cover complete all as specified & directed by Engineer-in-charge.
S&F in repair wash hand basin oval type vitereous china flat back size 550 x 400 mm white incl CP waste coupling waste pipe brackets complete all as specified & directed by Engineer-in-charge.
S&F rotational moulded polyethylene water storage tanks 1000 litres capacity triple layered (White) cylindrical vertical with closed top hoisted and 20mm ball valves high pressure with polythene float and flynut complete fixed in position including dismantling water tank of capacity exc 500 lt but n exc 1000 ltand removing to store of any description complete all as specified & directed by Engineer-in-charge.
S&F in repair 32 mm dia., Waste fittings, brass chromium plated for glazed ware sinks, wash basins etc, with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end complete all as specified & directed by Engineer-in-charge.
S&F in repair 15mm dia stop valves (concealed type) fancy type cast copper alloy chromium plated screwed down high pressure with crown or capstan head screwed both ends for iron pipe with long shank and cup complete all as specified & directed by Engineer-in-charge.
S&F in repairs vitreous china urinals with urinal spreader, half stall (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing or complete all as specified & directed by Engineer-in-charge.
S&F steel water tubing 15 mm bore dia medium grade galvanised with and including necessary all fittings and fixtures complete fixed to walls and ceilings or laid in floors etc including taking down existing GI pipe of any description complete all as specified & directed by Engineer-in-charge.
S&F steel water tubing 20 mm bore dia medium grade galvanised with and including necessary all fittings and fixtures complete fixed to walls and ceilings or laid in floors etc including taking down existing GI pipe of any description complete all as specified & directed by Engineer-in-charge.
M&L Granite (of any type) tile 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing laid on complete all as specified & directed by Engineer-in-charge.
S&F steel ventilators with top hung shutters fitted with box type hinges including MS peg stays, MS handle and glazing bars dovetailed or welded for receiving glass including painting with one shop coat of zinc chromate primer,and cutting holes in wall for fixing the window lugs in PCC 1:2:4 type B1 using 20mm graded aggregate and making good the disturbed surfaces in CM (1:3) and applying two coats existing wall finishes to match with existing colour complete all as specified & directed by Engineer-in-charge. Note : The rate quoted by the contractor deemed to inclusive of making good all the disturbed surfaces to match with the existing surfaces and including necessary scaffolding etc up to 4th floor.
S&F steel window with side hung shutters fitted with box type hinges including MS handles, peg stays, MS guard bar made out of 10 mm squre bar, glazing bars dovetailed or welded for receiving glass and including painting with one shop coat of zinc chromate primer including cutting holes in wall for fixing the window lugs in PCC 1:2:4 type B1 using 20mm graded aggregate and making good the disturbed surfaces in CM (1:3) and applying two coats existing wall finishes to match with existing colour complete all as specified & directed by Engineer-in-charge. Note : The rate quoted by the contractor deemed to inclusive of making good all the disturbed surfaces to match with the existing surfaces and including necessary scaffolding etc up to 4th floor.
Resecuring or easing & adjusting without taking down shutters of any description exc 1 Sqm but n exc 2 Sqm each complete all as specified & directed by Engineer-in-charge.
S&F in repair steel window handle left and right complete fitting complete all as specified & directed by Engineer-in-charge.
S&F in repair steel window stopper peg stay complete fitting complete all as specified & directed by Engineer-in-charge.
M&L perpartion of old existing wall surfaces including cornices, plastered or un-plastered surfaces by brooming down or steel wire brushing, moss efflorescent salt and trading oil and greasy spots and applying one coat of cement base paint over and including filling up of holes with putty wherever required complete all as specified & directed by Engineer-in-charge.
M&L perpartion of old existing wall surfaces including cornices, plastered or un-plastered surfaces by brooming down or steel wire brushing, moss efflorescent salt and trading oil and greasy spots and applying one coat of white wash on wall over and including filling up of holes with putty wherever required complete all as specified & directed by Engineer-in-charge.
M&L perpartion of old existing wall surfaces including cornices, plastered or un-plastered surfaces by brooming down or steel wire brushing, moss efflorescent salt and trading oil and greasy spots and applying one coat of white wash on ceiling over and including filling up of holes with putty wherever required complete all as specified & directed by Engineer-in-charge.
M&L hardcore of broken bricks filling of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified & directed by Engineer-in-charge.
M&L for plain cement concrete (1:5:10) type E2 (using 40 mm graded stone aggregate) as filling of sunken floors complete all as specified & directed by Engineer-in-charge.
M&L rendering 15 mm thick in CM (1:4) on fair face of brick work/ concrete surface finished even and smooth without using extra cement mix with using water proofing compound as per manufacturers instructions complete all as specifed and directed. Note:- Supply only water proofing compound shall be measured and paid seperately.
Supply only integral water proofing compound (ISI marked) complete all as specified and directed by Engineer-in-charge.
M&L for applying two coats of NITOBOND SBR polymer modified coating to a thickness of 1mm, 1st Coat (Nitobond SBR Chemical 1 ltr, Water 2 Ltrs, Cement 3 Kg) Second Coat (Nitobond SBR Chemical 1 ltr, Cement 3 Kg) including preparation thoroughly without any traces of dirt or laitance as in sunken floors complete all as directed by Engr-in-Charge.
Dismantling of 100 mm dia cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches of any size complete all as specified & directed by Engineer-in-charge.
S&F 75 mm bore PVC (SWR) pipe single socketed in any length with rubberring joints fixed to walls with clamps complete all as specified & directed by Engineer-in-charge.
S&F 110 mm bore PVC (SWR) pipe single socketed in any length with rubberring joints fixed to walls with clamps complete all as specified & directed by Engineer-in-charge.
S&F 75 mm bore PVC (SWR) pipe single socketed in any length with rubberring joints laid in trenches or in floors complete all as specified & directed by Engineer-in-charge.
S&F 110 mm bore PVC (SWR) pipe single socketed in any length with rubberring joints laid in trenches or in floors complete all as specified & directed by Engineer-in-charge.
S&F PVC (SWR) bend any radius of 75 mm bore complete all as specified & directed by Engineer-in-charge.
S&F PVC (SWR) bend any radius of 110 mm bore complete all as specified & directed by Engineer-in-charge.
S&F PVC (SWR) branch piece, single (single Y), equal or unequal any radius of 75 mm bore complete all as specified & directed by Engineer-in-charge.
S&F PVC (SWR) branch piece, single(single Y), equal or unequal any radius of 110 mm bore complete all as specified & directed by Engineer-in-charge.
S&F PVC (SWR) vent cowl any radius of 75 mm bore complete all as specified & directed by Engineer-in-charge.
S&F PVC (SWR) vent cowl any radius of 110 mm bore complete all as specified & directed by Engineer-in-charge.
M& L for PVC (SWR) floor trap of size 75mm, plain with grating including jointing with solvent cement complete all as specified & directed by Engineer-in-charge.
S&F PVC (SWR) 110 mm dia P trap complete all as specified & directed by Engineer-in-charge.
S&F in repair, tubular towel rail brass chromium plated, 20mm dia, D type, 60cm long between flanges fixed with chromium plated brass screws complete all as specified & directed by Engineer-in-charge.
S&F flush cutting of RCC chajjas, fins with reinforcement up to 150 mm depth by RCC mechanical cutting machine complete all as specified & directed by Engineer-in-charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified & directed by Engineer-in-charge.
S&F mild steel rolled sections Fe 410W (Gde-E 250 quality B) as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed by the Engineer in charge.
M&L for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by the Engineer in charge.
Demolition of Brickwork or stone/ boulder masonry, built in Cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles etc complete all as specified & directed by Engineer-in-charge.
M&L squared rubble walling Jodhpur type, brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified & directed by Engineer-in-charge.
Extra over stone walling for hammer dressing to face stones with maximum depression on face from a straight edge not exc 20mm & dressing face beds and joints as specified to squared rubble walling Jodhpur type brought up to courses complete all as specified & directed by Engineer-in-charge.
M&L for Keyed pointing to squared rubble masonry, coursed or uncoursed in CM 1:4 complete all as specified & directed by Engineer-in-charge.
Demolition of existing roof terracing of cement/brick concrete(un-reinforced) and existing water proofing treatment of any thickness in any position on top of roof of building, cleaning surface of roof with brush/mechanical brush and with water throughly to romove all dust/dirt and loose particles to expose bare concrete roof slab and romoval of rubbish/demolished material out side MD land complete all as specified Note : Demolition should be done by means chiselling.
M&L for PCC (1:2:4) type B-0 (using 12.5 mm graded stone aggregate) as in levelling padding course over RCC roof surface including rounded or chamferred on edges etc., with approved liquid water proofing compound all as per manufacturer's instructuions on the roof surface to achieve requisite slope complete all as specified & directed by Engineer-in-charge. (Note :- Supply only liquid water proofing compound shall be measured & paid separately).
Supply only liquid water proofing compound complete all as specified & directed by Engineer-in-charge.
M&L for providing APP based polymeric membrane minimum weighing 3kg/Sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/Sqm) land on primed surface by forced application incl applying evenly bitumen tack coat primer of industrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning surfaces and laying over finished surface with screed of 25mm thick CM 1:4 with water proofing compound complete all as specified with the following specifiations :-
ITEM NO. 96.00 CONTD... (a) Cleaning existing surface properly. (b) Apply oil bound bitumen primer @ 0.40 lit/Sqm manufactured by the same agency as that of APP with a density of 0.87 -0.89 Kg/Lit at 25 Degree Centigrade on the prepared dry roof surface. (c) Providing and Laying APP modified water proofing membrane reinforced with non wooven polyster matt with physical propertities as under :- (i) Membrane weight >3.6 Kg/Sqm. (ii) Net wooven polyster weight >160 gm/Sqm (iii) Softening point of membrane > 150o C (iv) Joint Tensile strength Longitudiual > 650 Sq Cm at 230o C & Transverse > 450/ Sq cm (v) Tear strength - Longitudual > 300 N & Transverse > 250 N Direction (vi) Elongation > 30 % (vii) Impermeability under water pressure > 3 Kg/Sq cm
ITEM NO. 96.00 CONTD... Note:- APP membrane shall be laid using butane torch by Torch application with minimum 10 cm side overlap and 15 cm end lap. The laying of membrane shall be got done through authorised applicator of manufacturer of membrane. (d) Over the membrance provide a finishing with solar reflective bituminous aluminium paint @ 0.1 Kg/Sqm as prescribed by manufacture of membrane
Taking down carefully surface aluminium or copper point wiring with PVC casing-caping (light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc ,removal to store for safe custody for issue under schedule of credit and making good disturbed surfaces complete all as specified & directed by Engineer-in-charge.
Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as existing at site including MCBs any type and capacity making good the disturbed surfaces to match with the existing finishes complete all as specified & directed by Engineer-in-charge.
Taking down the existing unservicable sub main wiring of any type / description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as specified & directed by Engineer-in-charge.
Taking down of old unsv tubelight fitting /surface panel light / flood light of any description light fitting any type any watt complete all as specified & directed by Engineer-in-charge.
M&L Point wiring with 1100 volts grade PVC insulated FR-LSH multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal boxes of thickness not less than 1.2 mm with 3 mm thick phenolic laminated white sheet cover for mounting of Piano Type switches, sockets, fan regulators complete for the following :-
(a) One light point controlled by one switch.
(b) One fan point controlled by one switch.
(c) One bell/buzzer point controlled by one push botton.
(d) One socket outlet 6 amp controlled by one switch on the same board with other switches.
(e) One light point controlled by two, 2 way switches.
All as per item No 101.00 here on before but with copper conductor cable of nominal class area 2.50 sq mm for phase, neutral & earth for One 2/3 pin socket outlet 5 Amps on independent board complete all as specified & directed by Engineer-in-charge.
All as per item No 101.00 here on before but with copper conductor cable of nominal class area 4.0 sq mm for phase, neutral & earth for power socket point 15 Amps complete all as specified & directed by Engineer-in-charge.
S&F switch piano flush button single pole one way 5/6 amp complete all as specified & directed by Engineer-in-charge.
S&F switch piano flush button single pole one way 16 amp complete all as specified & directed by Engineer-in-charge.
S&F socket outlet 2 in 1, 3 pin 6 & 16 amp flush type complete all as specified & directed by Engineer-in-charge.
S&F socket outlet 2 in 1, 2 & 3 pin, 6 amp, flush type complete all as specified & directed by Engineer-in-charge.
S&F hum free electronic step fan regulator 120 - 280 volts of 100 watt capacity (socket type) including connecting up complete all as specified & directed by Engineer-in-charge.
S&F of bell push flush type 5 Amps complete complete all as specified & directed by Engineer-in-charge.
S&F of switch piano, flush type, 5 amps, 230 volts, single pole, two way (ISI marked) complete all as specified & directed by Engineer-in-charge.
S&F of bell AC single pole Ding Dong type 230 volt complete all as specified & directed by Engineer-in-charge.
S&F Ceiling rose, three terminals PVC/polycorbonate, isolated body complete all as specified & directed by Engineer-in-charge.
S&F vertical DBs TPN 4 way 415 V double door powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 250 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required,suitable for TP/FP MCCB as incomer including MCCB 100 A , and with SP/TP MCCB's as incoming MCCB FP 100 A, 25 KA complete all as specified & directed by Engineer-in-charge.
S&F for MCB DB SPN 12 way double door IP 43 prewired including Bus Bar etc suitable for operation on 240 volt 50 Hz AC supply including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified & directed by Engineer-in-charge.
Supply and fixing MCB's single pole and neutral 63 Amps, 240 Volts, 10 KA rapturing capacity 'C' curve complete all as specified & directed by Engineer-in-charge.
Supply and fixing MCB's single pole 10 Amps to 32 Amps, 240 Volts,10 KA rapturing capacity 'C' curve complete all as specified & directed by Engineer-in-charge.
M&L for submain wiring with approved colour code/as per IS (Red,black & green for single phase)concealed conduit circuit with two single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 6.00 Sqmm (FRLS) in conduit including one run of PVC insulated multistranded copper conductor nominal cross sectinal area of 6.00 Sqmm (FRLS) of continous earth wire green in colour complete all as specified and directed by Engr-In-Charge. Note :- Two runs of 6.00 Sqmm cable & one run of 6.00 Sqmm cable as earth wire and one run of PVC conduit shall be measured and paid as one unit length.
S&F in repair sheet metal enclosure MCB 20 Amp single pole as incomer complete all as specified & directed by Engineer-in-charge.
S&F in repair building security light fitting LED 35 Watt IP 66 IK 07 pressure dia cast aluminium housing with high efficient LED as lighting souce and PC cover having TOP opening sepreate drive compartment etc and connecting complete all as specified & directed by Engineer-in-charge.
S&F bracket of GI pipe medium grade of 40mm dia, 1.2 meter in length clamps made of FI 40 mm x 6mm incl nuts, bolts & washers, painting and including taking down existing bracket complete all as specified & directed by Engineer-in-charge.
Supply and fixing of LED box type Integrated Batten 40 watt having Aluminum Extruded housing in white powder coated Finish with high translucent PC Cover, Elegant Design, IP 20 Protection. Dimensions of the Fitting Shall be Not less then 1200 mm (Length) X 40 mm (Width) X 63 mm (Height ). Lumens output of the fitting shall be not less then 4000 lm, CCT 5700 – 6500 K, buring hours 50,000 Surge Protector 4 KV, PF>= 0.95 , Separate detachable type Electronic constant current drivers for easy replacement and aintenance, THD < 10% , Necessary mounting arrangements .The fixture shall be suitable for wall mounting /suspension mounting as per site requirement . The Manufacturer of the fixture shall have in house NABL Accredited Lab and must produce certificate of the same along with LM-79 / LM80 / Test Report as per Crompton Cat Part No. Shelter . CIS -305-40-57-SL-DP-NWH or equivalent in Appx 'C' list of makes.
S&F LED tube light fitting 10 watt tube LED Neutral white in colour, 600 mm in length wall mounted LED batten, extruded aluminium heat shink provided for efficient heat dissipation & integrated electronic driver, optic diffused type ENDURA LINER NEO including all electric connection with whilte flexible cord 1.50 Sqmm 3 core as required complete all as specified & directed by Engineer-in-charge.
Taking down ceiling fan /exhaust fan of any sweep, dismanting blade and including preparation, filling cavity applying one coat of synthetic enamel paint by using mechanical spraying machine, re-assembling the fan body to fan and re-fixing in its original position or any other position complete all as specified & directed by Engineer-in-charge. Note :- Rate quoted by the contractor shall deemed to inclusive of replacing of quarter pin, nut bolt with check nut, rubber real etc.
S&F ceiling fan complete with three blade, down rod with all accessories 230 V, 1200 mm sweep including necessary connecting cable recommended / provided by manufacturer complete all as specified & directed by Engineer-in-charge.
S&F Steel body heavy duty exhaust fans AC single phase 230/ 240 V of size 300 mm sweep with louver complete all as specified & directed by Engineer-in-charge.
S&F water heater storage type (Geyser) vertical type, inner container of capacity 50 ltrs, power Consumption 2.0 KW, BEE 5 star rated pressure rating >8 Bar electrically operated, AC 230 Volts, including suitable size fastners/ rawal plugs as required at site for fixing in brick masonry/ stone masonry wall complete all as specified & directed by Engineer-in-charge. Make: Havells Cat Part No : Monza DX GHWAMGTWH050 or equivalent in Appx 'C' list of makes.
M&L for PVC connection pipe chromium plated 15 mm dia both end threaded incl brass coupling bolt cone washer complete, length of pipe is not less than 450 mm suitable for Hot/ cold water system complete all as specified & directed by Engineer-in-charge.
S&F 15 mm bore stop valve, cast copper alloy, screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or for union complete all as specified & directed by Engineer-in-charge.
S&F 15 mm bore bib tap, fancy type, chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified & directed by Engineer-in-charge.
Supply & fixing single pole and neutral enclosure with two pin and earth plug and socket with one SP MCB 20 Amps complete all as specified & directed by Engineer-in-charge.
S&F steel water tubing 15 mm bore dia medium grade galvanised with and including necessary all fittings and fixtures to walls and ceilings or laid in floors etc complete all as specified & directed by Engineer-in-charge.
M & L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, charcoal & salt up to ground level connected to galvanized iron wire 4 mm dia as earthing lead up to Panel /DB BOX as per site requirement by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection including test point terminal cover the earhing hole by PCC chamber and GI cover and testing on completion and including taking down existing earthing complete all as specified & directed by Engineer-in-charge.
NOTE FOR ITEM No. 132.00 [i]. Excavation & earth work in any type of soil including removing of surplus material upto 100M [ii]. PCC (1:3:6) type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC (1:2:4) type B1 cover 50x50 cm with 8mm round bar @ 15 cm C/C both ways. [iii]. Main earthing strip from earth electrode to test point upto 7.5 mtr. [iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs and charcoal & salt as reqd. [v]. GI protection pipe of size 40 mm bore light grade 7.5m.
Supply, lay, test and commissioning of LT UG, XLPE insulated, heavy duty, 1100V grade of size 25 sq mm. 4 core electric cable with aluminum conductor, served with an inner sheathing of PVC tape armored with galvanized steel wire or tape and overall PVC sheathed, laid in trenches or passing through pipe, making all connections with and including provision of necessary glands, lugs, bushing etc as required complete all as specified and as directed by Engineer-in-Charge of following sizes:- Note : Earth work excavation sand cushioning, Jodhpur Stone patti, GI protection pipe shall be measured and paid separately under respective items of this schedule.
M&L for sand cushioning to under ground cable using tibba sand and gently punning to cushioning to cable complete all as directed by Engineer-in-Charge. Note :- Punned thickness of sand cushioning shall only measured for the purpose of payment.
Supply & laying 40 to 50mm thick roughly hammer dressed Jodhpur stone patti cable cover 25cm to 30cm wide and n. exc 60cm long each laid dry abutting with each other with maximum gap between adjacent slabs n. exc 10mm complete all as specified & directed by Engineer-in-charge.
Material and labour for cutting the existing bituminous road / hard standing to size not exceeding 45cm wide and depth not less than 45cm for passing of UG cable through GI pipe and making good the disturbed surface filled with excavated material and top 200mm depth with plain cement concrete 1:3:6, type C1 using 20mm graded aggregate complete all as specified & directed by Engineer-in-charge.
S&F steel water tubing 40 mm bore, 'light grade' galvanised, with all fitting and fixed to walls and ceilings or laid in floors in trench on pole for protection of cable etc and including taking down existing pipe of any description complete all as specified & directed by Engineer-in-charge.
AMBEY MAA CONSTRUCTION COMPANY
M/s Shri Inder Construction Company
Bhawani Constructions
M/S MAYA CONSTRUCTION COMPANY
Paliwal Construction Company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .