| 1 | 1₹9.9 LAccepted-AOC 1442 1 NANADANPURA BABINA CANTT TEHSIL DISTT JHANSI UP | BABINA | JHANSI | UP | 1 | Accepted-AOC LOWEST BIDDER | |
| 2 | 2₹11.0 L+₹25,550 (2.38%)Rejected-Finance HOUSE NO 164 SHASTRI NAGAR NEAR JAL NIGAM BABINA CANTT DISTT JHANSI UP | BABINA CANTT | JHANSI | UTTAR PRADESH | 2 | Rejected-Finance NOT LOWEST BIDDER | |
| 3 | 3₹11.2 L+₹44,450 (4.14%)Rejected-Finance CIVIL LINE MATATILA ROAD TALBEHAT DISTT LALITPUR U P | TALBEHAT | LALITPUR | U P | 3 | Rejected-Finance NOT LOWEST BIDDER | |
| 4 | 4₹11.4 L+₹66,098 (6.15%)Rejected-Finance SHIV NIWAS DHANDA P O TOTU DISTT SHIMLA HP 171011 | SHIMLA | SHIMLA | HIMACHAL PRADESH | 171011 | 4 | Rejected-Finance NOT LOWEST BIDDER | |
| 5 | 5₹11.7 L+₹99,730 (9.28%)Rejected-Finance | 5 | Rejected-Finance NOT LOWEST BIDDER |
Tender Value
₹10.0 L
EMD Value
₹19,980
Closing Date
5 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
BRIJ BIHARI
LAKEVIEW CAMP MIL STN TALBEHAT 284125
REPAIR/ MAINT TO CEILING, EXHAUST, WALL MOUNTED FANS, GEYSER FITTINGS AND FIXTURES AT MIL STN TALBEHAT
2024_MES_659642_1
AGE (I) TBT/TOK-17/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
TALBEHAT MIL STN
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
AGE I TALBEHAT
₹19,980
23 Sept 2024
14 Jun 2024
8 Jul 2024
21 Jun 2024
5 Jul 2024
28 Jun 2024
Amount
GEYSER :-
Taking down un serviceable Geyser having complete damaged Inner/Outer tank any capacity and type.
Supply and fix in repair Geyser element of 1500 watt (Screw/Cup type) suitable for 25/35 litre geyser of any make and type as directed by Engineer-In-Charge.
Supply and fix in repair Geyser element of 2000 watt (Screw/Cup type) suitable for 50 litre geyser of any make and type as directed by Engineer-In-Charge.
Supply and fix in repair indicator lamp suitable for 25/50 litre geyser of any make and type as directed by Engineer-In-Charge.
Supply and fix in repair 3 core PVC seathed flexible cable of size 1.5 sqmm complete as directed by Engineer-In-Charge.
Supply and fix in repair of inner tank (Steel) of Geyser 50 litre capacity complete as directed by Engineer-In-Charge.
Supply and fix in repair of inner tank (Steel) of Geyser 25 litre capacity complete as directed by Engineer-In-Charge.
Supply and fix in repair of outer tank/cover (Steel) of Geyser 50 litre capacity complete as directed by Engineer-In-Charge.
Supply and fix in repair of outer tank/cover (Steel) of Geyser 25 litre capacity complete as directed by Engineer-In-Charge.
Supply and fix in repair of Aperture plate (On which Heating Element and Thermostate switch Installed) of Geyser 25/50 litre capacity complete as directed by Engineer-In-Charge.
Supply and fix in repair of mettalic pipe connector flexible 15 mm bore (For hot & cold water) including two nos CP brass coupling, 250 mm long complete as directed by Engineer-In-Charge.
Supply and fix in repair of thermo state switch suitable for 25/50 litre Geyser complete as directed by Engineer-In-Charge.
Supply and fix in repair of safety valve 15/20 mm dia as requirement of site suitable for 25/50 litre Geyser complete as directed by Engineer-In-Charge.
Supply and fix in repair of fuseable plug 15/20 mm dia as requirement of site suitable for 25/50 litre Geyser complete as directed by Engineer-In-Charge.
Supply and fix in repair plug top, 3 pin, 15 Amp for 25/50 litre Geyser complete as directed by Engineer-In-Charge.
S&F in replacement single pole and neutral enclosure with a two pin and earth socket complete with one single pole MCB of 20 Amp 240 volt.
M&L for Grouting of fast nut in replacement 150 mm long and 16 mm dia in wall with drilling arrangement/by suitable aggregate of cement and sand, for fixing of Geyser complete with one nut and one washer.
CEILLING/EXHAUST FAN :-
M&L for rewinding of ceilling fan, 1200-1400 mm sweep, AC 220 volt, Single phase, 50 Hz, of any make, Model and vintage with super enameled copper wire with same gauge and turn with and including top quality of insulation material such as varnish, cotton tape and sleeve etc., Including painting one coat of white sinthetic enamel paint on body and blade also and marking Fan No on that. Complete all as specified and directed by Engineer-In-Charge.
M&L for rewinding of Exhaust fan, 225-300 mm sweep, heavy duty, AC 220 volt, Single phase, 50 Hz, of any make, Model and vintage with super enameled copper wire with same gauge and turn with and including top quality of insulation material such as varnish, cotton tape and sleeve etc., Including painting one coat of smoke grey sinthetic enamel paint on body and blade also and marking Fan No on that. Complete all as specified and directed by Engineer-In-Charge.
M&L for rewinding of Exhaust fan, 400-450 mm sweep, heavy duty, AC 220 volt, Single phase, 50 Hz, of any make, Model and vintage with super enameled copper wire with same gauge and turn with and including top quality of insulation material such as varnish, cotton tape and sleeve etc., Including painting one coat of smoke grey sinthetic enamel paint on body and blade also and marking Fan No on that. Complete all as specified and directed by Engineer-In-Charge.
M&L for rewinding of wall mounted fan, 300-450 mm sweep, heavy duty, AC 220 volt, Single phase, 50 Hz, of any make, Model and vintage with super enameled copper wire with same gauge and turn with and including top quality of insulation material such as varnish, cotton tape and sleeve etc., Including painting one coat of existing colour sinthetic enamel paint on body and blade also and marking Fan No on that. Complete all as specified and directed by Engineer-In-Charge.
S&F in replacement of ball bearing No.6201.
S&F in replacement of ball bearing No.6202.
S&F in replacement of ball bearing No.6203.
S&F in replacement of ball bearing No.6204.
S&F in replacement of Gun Metal Bushes for ceiling fans.
S&F flexible copper cable of size 23/0.0076, 2 core, for ceilling and exhaust fan complete for connection and directed by Engineer-In-Charge.
S&F in repair of MS clamp for holding ceilling fan with nut, bolt & split pin etc, complete all as specified and directed by Engineer-In-Charge.
S&F in replacement Ceiling fan blade 1200-1400 mm sweep (Set of three) complete all as specified and directed by Engineer-In-Charge.
S&F in replacement Canopy Suitable for Ceiling Fan of any make and size complete all as specified and directed by Engineer-In-Charge.
S&F in replacement exhaust fan blade 300 mm sweep complete all as specified and directed by Engineer-In-Charge.
S&F in replacement wall mounted fan blade 300 mm sweep complete all as specified and directed by Engineer-In-Charge.
supply and fixing capacitor 3.15 mfd suitable for exhaust fan/ceilling fan complete all as specified and directed by Engineer-In-Charge.
Supply and fixing capacitor 2.5 mfd suitable for ceilling fan complete all as specified and directed by Engineer-In-Charge.
M&L for cutting of hole 300mm dia at 9" wall for exhaust fan including PCC (1:3:6) type C-1 and one coat of exsiting white wash over distrubed area complete all as specified and directed by Engr-in-Charge.
Fixing only repair digital Meter in place of defective meter, proper wiring by lugs complete all as specified and directed by Engr-in-Charge (Note: Repair Meter provided by the Department on no cost basis in (E/M) yard)
M&L for sub main wiring with two single core PVC insulated of size 6 sqmm FRLS unsheathed copper conductor 1100 volt grade multistandard and including flexible PVC conduit of 25 mm external dia for digital meter connection complete all as specified and directed by Engr-in-Charge.
M&L for cutting exceeding 20 cm girth chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc, and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good,
S & F for Rigid non-metallic PVC 20mm dia conduit exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.
M&L for cutting of PCC/roads for earthing pipe including PCC (1:3:6) type C-1 for distrubed area complete all as specified and directed by Engr-in-Charge.
Supply and laying or fixing GI tubes light grade 25 mm dia, on support of cables, on pole/wall/laid in floor/in trenches including clamp and nut bolts.
S & F Square 2x2 Panel LED Panel Light, Warm White, 6000 K Make : Panasonic or equivalent complete all as specified and as directed.Make : Havells/ Panasonic/ Surya
S&F Bajaj BZRSQL 18 W WH 240V, 50 Hz 42 LED Series Recessed downlight or equivalent make and size as per existing and cutting of the surface/ ceiling and making good to the surface/ ceiling all as specified and as directed. Havells/ Panasonic/ Surya
S&F Modular Socket, 6A/16A-2/3 pin combined 2 module.
S&F Socket outlet 2 in 1, 3 pin , 6 and 16 amps flush type.
Suppl and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of sutable size complete all as aspecified and directed. Make : Havells/ Panasonic/ Surya
Note :- (i) Disconnection of Geyser and fans from electric source, inspection of problem, taking down to ground, and transportation from site to market for repair/brazing will be deemed to be included in the rate quoted by the contractor without incurring any extra cost to the department. (ii) Srl Item No 11 and 12 will be issue under Schedule ,B, free for fixing only. (iii) Debris obtained from all items should be removed in low lying areas as directed by Engr-in-charge out of MOD Land. (Rates quoted for items are deemed to be included for this, where removal of debris in the items is not considered.)
m/s bobby enterprises (BID ID -3049198)
HARNAM SINGH ANIL SINGH (BID ID -3048264)
M/s Dinesh Kumar (BID ID -3050550)
M/s Indu Enterprises (BID ID -3050980)
M/S Kharya Associates (BID ID -3050536)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .