Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.2 LAccepted-AOC 31 1 6 SEBADAL ROAD UDAYPUR NIMTA KOLKATA 49 | 24 PARAGANAS NORTH | WEST BENGAL | 700049 | L1 | Accepted-AOC AOC | |
| 2 | L2₹39.3 L+₹2,152.79 (0.05%)Rejected-Finance MATHURAPUR SONARPUR KOL 700150 | MATHURAPUR | SOUTH 24 PARGANAS | WEST BENGAL | 700150 | L2 | Rejected-Finance HIGHER THAN L1 | |
| 3 | L3₹41.3 L+₹2.0 L (5.13%)Rejected-Finance 2 JORA BAGAN STREET KOLKATA 700 006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | L3 | Rejected-Finance HIGHER THAN L1 | |
| 4 | L4₹47.9 L+₹8.7 L (22.2%)Rejected-Finance 46 SHYAMA PRASAD MUKHERJEE ROAD KOLKATA 700 026 | KOLKATA | KOLKATA | WEST BENGAL | 700026 | L4 | Rejected-Finance HIGHER THAN L1 |
Tender Value
₹48.3 L
EMD Value
₹96,670
Closing Date
18 Mar 2024, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE_KCED_PWD
Khadya_Bhawan_11A_Mirza_Ghalib_Street_Block_A_3rd_Floor_Kokata_700087
Repairing and renovation to the existing Electrical Installation works of State Swimming Academy at Subhas Sarobar swimming Pool.
2024_PWDE_675315_1
WBPWD/EE/56/IR/T/KCED/II of 2023-24
Open Tender
Electrical Work/ Equipment
Item Rate
45 days
Subhas Sarobar swimming Pool
Please refer Tender documents.
4 documents required · 4 mandatory
₹96,670
Office_of_EE_KCED_PWD
7 Jan 2025
27 Feb 2024
20 Mar 2024
27 Feb 2024
18 Mar 2024
5 Mar 2024
4 Mar 2024
Amount
Dismantling of old existing Panel, Main Switch, Switch boards, wire, cable, fittings- fixture etc and and submit that to the concerned authority.
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand RR Kable/Polycab/KEI approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Anchor make) fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC
Average run 6 mtr
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand RR Kable/Polycab/KEI approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point incl. S&F 240 V 5A 3 pin flush type plug socket & piano key type switch (Anchor make) incl. S&F earth continuity wire, fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish
On Board
Average run 6 mtr
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed]
Average run 8 mtr
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand RR Kable/Polycab/KEI approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish
On Board
Average run 6 mtr
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works incl. supply & fixing bakelite/perspex top cover by Brass screws as per GS.
150mm x 100mm x 65mm
Cutting channel of 40 mm x 40 mm size on masonry wall incl.S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works
19 mm dia 3 mm thick polythene pipe without earth continuity wire
Cutting channel of 43 mm x 43 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works
25 mm dia 3 mm thick polythene pipe without earth continuity wire
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works
20mm size
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand RR Kable/Polycab/KEI approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required
3 x 22/0.3 (1.5 sqmm)
2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC
2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC
2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC
4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC
S & F solderless Copper socket by crimping of Copper wires.
a)1.5 sq mm
b) 2.5 sq mm
c) 4 sq mm
d) 6 sq mm
e) 10 sq mm
Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.
100 A (On Angle iron frame) (Make- L&T/Siemens]
32 A (On Angle iron frame) (Make- L&T/Siemens]
63 A (On Angle iron frame) (Make- L&T/]
200 A (On Angle iron frame) (Make- L&T/Siemens] [Required for I/C Raw Power at Meter Room & Pump Room I/C SFU]
Supplying and fixing Sheet steel Main Switches on flat iron frame on wall
32 A DP, 240 V with fuse on L & N [Make:- Havells]
Supplying and fixing 415V, TPN on load front operated Changeover switch open execution type in SS enclosure/cubical with nuts bolts etc
125 A [Make- L & T}
Supplying and fixing sheet steel (16SWG) cable end box on TPN SFU enclosure with nuts bolts etc incl. powder coated painting.
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment
2 Way [Make- Legrand]
4 Way [Make- Legrand]
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment
8 Way Make- Legrand]
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment
4 Way [Make- Legrand]
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.
2+16 Way [Make- Legrand]
2+12 way [Make- Legrand]
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection
100 A [Make- Legrand]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection.
40 A DP [Make- Legrand]
63 A FP [Make- Legrand]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection
SP 6-32 A [Make- Legrand]
DP 40 A [Make- Legrand]
TP 63 A [Make- Legrand] [Required for VTPNDB O/G]
FP 40 A [Make- Legrand] [Required for Suction Motor Fidder Piller box O/G]
FP 32 A [Make- Legrand] [Required for Suction Motor Fidder Piller box O/G]
FP 63 A [Make- Legrand]
Repairing the existing Main Panel at meter room and cleaning the dust particle and removing some damge wire, cable and other accessories(like MCB, Isolatror, TPN/DP SFU, Voltmeter, Ammeter, Indicating Lamp etc, including Painting the exsiting Main Panel box inner and outer both side with one no. of coats of primer of approved make, and 1st coat of aluminium paint over one coat of RO priming. 2nd coat of aluminium paint over 1st coat. After that Proper colour code to be provided by PVC heat shrink sleevesar on Bus bar. S & F of the following items:-
Outgoing:-a)415V, 125 A 4 Pole MCCB 25/35 KA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting ( Make- Legrand) 1 nos.
b) 240/415 V 63 A 4 Pole MCB of Breaking capacity 10kA & C characteristics fixing on din rail ( Make- Legrand) 08 nos. c) 240/415 V 100 A 4 Pole MCB of Breaking capacity 10kA & C characteristics fixing on din rail ( Make- Legrand) 02 nos.
Supply,erection & installation of outdoor hooded type KIOSK made of 5 mm thick MS sheet having height-1400 mm, width-1000 mm & depth-750 mm provided with gasketed double leaf double door arrangement. The doors should have both railway type locking arrangement as well as pad locking system. The Kiosk shoul be provided with four nos lifting lugs on opposite sides of vertical walls.The Kiosk to be provided with brass mesh for proper ventilation at the top at the fixed two vertical sides of the body of the Kiosk. The hood of the Kiosk should be extended sufficiently to prevent rain water infiltration through the brass mesh and the door leafs to be overlapped sufficiently to prevent rain water ingress inside the kiosk.There should have at least 2 (two ) nos earthing terminals provided on the opposite fixed vetical outer walls near the base.All inside and outside walls to be painted with two coats of synthetic enamel paint over one coat of R.O. primer. The kiosk to be erected on the brick pedastal of size 1600 mm x 1300 mm & height -600 mm having hollow space inside filled with dry sand and neat cemented finish with properly maintained slope on the outside to prevent water logging at the foot of the Kiosk provided with cable entry and exit facilities at the base of the pedastal. The metal structure should have self supporting and long angle iron legs having bifercation at the bottom for grouting inside the muffing of the pedastal.The kiosk to be provided with two layers of horizontally alligned 50 mm x 5 mm MS flats welded properly with the body of the kiosk in which each layer should have at least 4(four) nos of MS flats with holes provided with proper size of nuts and bolts for fixing switches and bus bars so that all switches and bus bar chamber can be fixed in door facing orientation.The Kiosk to be provided with the followings-
415 Volt,200 amps TPN main switch with HRC fuses (L & T) as incomming switch-1 no.
415 V, 250 amps,4 bar copper bus bar of size 20 mm x 5 mm with chamber of adequate size- 1 set.
415V, 100A TPN SFU with 3 nos DIN type HRC fuses ( L & T )- 4 Set
415 V,32 Amps TPN main switch with HRC fuses (L & T)- 1 Nos.
415 V,63 Amps TPN main switch with HRC fuses (L & T)- 2 Nos.
EI Danger Board of size 12" x 8" - 2 sets
Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket (Brand approved by EIC), without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 2 nos 6A, plug socket with separate 2 nos 6 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections.
Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & fixing automatic single phase AC starter of 27Amp capacity equipped with Timecheck, Voltcheck & Ampcheck and 3-digit display (Make- Electron-model no.-OPL-3+ or equivalent model of LT/Legrand as per dierction of E.I.C) to be fixed on wall in 4M GI modular S.B with all fixing accessories complete as to G.S
Supplying & Fixing Industrial Plug & Socket board with 415 V, 30A,TPN & Earth Metal Industrial Plug socket & 30A Industrial top incl.S&F 32 A TPN/FP MCB breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and cecessary conection.
Supply & delivery of of 4 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Nicco/ Gloster/KEI/Polycab/ Havells]
2 Core 10 Sq. mm
4 Core 10 Sq. mm
4 Core 16 Sq. mm
4Core 35 Sq. mm
4Core 50 Sq. mm
4Core 120 Sq. mm
4Core 150 Sq. mm
Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting.
Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting
Laying of cable above 3½ core 90 sqmm and upto 3½ core 150 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed
Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS.
2 Core 10 Sq. mm
4 Core 10 Sq. mm
4 Core 16 Sq. mm
4Core 35 Sq. mm
4Core 50 Sq. mm
4 Core 120 Sq. mm
4 Core 150 Sq. mm
Supply and delivery of XLPE insulated 1100 V grade, 4C, 10 sqmm armoured copper cable(Make- Gloster,KEI,Polycab)
S & Delivery of single 4 ft., 22 watt LED light fitting complete with all accessories with tube lamps as follows:[Make -Philips cat no. TMC 502 P1 x T- LED 22 W ] or eqiv, Crompton/Havells as per choice of EIC.
S & Delivery of Double 4 ft., 22 watt LED light fitting complete with all accessories with tube lamps as follows:[Make -Philips cat no. TMC 502 P2 x T- LED 22 W ] or eqiv, Crompton/Havells as per choice of EIC.
Supply and fixing 9W LED bulb (Bajaj/CG/Philips/wipro /Havells) on existing batten holder
Supplying & Fixing of 10 Watt LED bulk head light fitting (Make- Crompton, Cat no.- LBHP-10-CDL of equivalent model of Philips/Bajaj/Wipro) suiitable for Surface and wall mounting application incl. necessary connection as per direction of EIC.
S & F 12 W LED (6'' dia)recess type light fittings complete with all accessories after cutting the false ceiling (Make-Crompton, Cat no- LCDEP-18-CDL or equivalent make Havells/ Philips as per choice of EIC. Incl. neccesary connection required.
Supply of ceiling fans with burst-proof P2/S3 Capacitor complete with all accessories without regulator. ( Make - Usha, Model- Striker or equivalent model of CG/Orient/Havells as approved by EIC)
1200 mm Sweep [
Supply of ceiling fans with burst-proof P2/S3 Capacitor complete with all accessories without regulator. ( Make - Usha, Model- Striker or equivalent model of CG/Orient/Havells as approved by EIC)
1400 mm Sweep
Supplying & Fixing MS fan clamp of two piece type for RCC as per approved specification as per GS.
Supplying & Fixing iron beam fan clamp of two piece type, as per approved specification, fabricated from 40 mm x 9 mm MS sheet flat suitable for beam having flange upto 150 mm wide
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS.
Extra for supplying additional wire for down rod & painting the rod exceeding 30 cm by 2x1.5 sqmm flexible copper wire as per GS.
Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc.
Supply & Delivery 450 mm/ 18 ", 85 Watts sweep wall bracket fan(high speed) with metal body & blades(Make- EPC, Model- Typhoon Circulator, 1420 RPM,or equivalent cat of CG/Orient /Cinni) with necessary wooden board on wall with nuts, bolts, washer etc.
Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length
Supply & Delivery heavy duty Exhaust fan(Make-EPC or equivalent make Crompton/Usha as approved by E.I.C]
9"( 230 mm ) Speed 1370 RPM
12''(300 mm) Speed 1420 RPM
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter:
Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall as per GS
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Fixing only single/twin LED Batten light fitting complete with all accessories Directly on wall/ceiling as per GS.
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVCround block / round bakelite on wall/ceiling as per GS.
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board
Fixing only outdoor / street light type fluorescent light fitting complete with all accessories to be fixed/projected from the wall of the building incl. making holes to building, S&F 40 mm dia GI pipe (ISI-Medium) 1.50 mts. average length, with GI socket at one end and thread at the other end & suitable bend to house the fitting making necy. connections with S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall and painting
Supply & Fixing of 240V, 30 W LED Street light luminarie complete with all accessories and equipped with IP65 Protection (Crompton Geaves-Cat no.- LSTS-30-CDL/NL-M or equivalent model of Havells/Philips/Bajaj//wipro/other equivalent make as approved by E.I.C) on existing MS Pipe/Mini Pole as per direction of E.I.C
Supply & Fixing of 240V, 120 W LED Street light luminarie complete with all accessories and equipped with IP65 Protection (Crompton Geaves-Cat no.-TRP-411-120-57-SL-GL-NSG or equivalent model of Havells/Philips/Bajaj//wipro/other equivalent make as approved by E.I.C) on existing MS Pipe/Mini Pole as per direction of E.I.C
Supply & fixing of 240V, 150 W LED Flood luminarie complete with all accessories and equipped with IP66 Protection (Crompton Geaves, Cat no.- LFLN-150-CDL/60-M or equivalent model of Havells/Philips/Bajaj//wipro/other equivalent make as approved by E.I.C) on existing MS Pipe/Mini Pole as per direction of E.I.C
Supply & fixing of 240V, 200 W LED Flood luminarie complete with all accessories and equipped with IP66 Protection (Crompton Geaves, Cat no.- LFLN-200-CDL/60-M or equivalent model of Havells/Philips/Bajaj//wipro/other equivalent make as approved by E.I.C) on existing MS Pipe/Mini/MS. Structure Pole as per direction of E.I.C
S & F only outdoor post top type LED light fitting complete with all accessories to be fixed/ projected from wall of the building/pillar incl. making holes on pillar top, S & F 40 mm di GI pipe (ISI-M) 0.40 mtr average length, with GI socket/ nipples at one end and thread at the other end to house the fitting & making necy connections with S & F necy length of 3 X 1.5 sq mm PVC insulated single core stranded annealed cu wire & making connections as reqd & mending good the damages to wall/pillar and painting.(Havells,CAT No-LHEVBHP7PN6K025 or equv. Crompton Type- MAPLE cat No.- LPTO-40-CDL-M)
Supply and Erection of (0.6x0.6x1.7)mtr. Of 9 mtr Single Steel tubular pole of length as given below with/without sole plate & Cap etc.
S & F 1.2 Mtr long 40 mm Dia Detachable type G.I Single Arm bracket with stifner plate, Pole Cap etc as required incl making through hole on bracket assembly for fixing the bracket rigidly on pole top.
S & F 1.2 Mtr long 40 mm dia detachable type G.I Double Arm bracket with stifner plate, pole cap etc as required incl making through hole on bracket assembly for fixing the bracket rigidly on pole top. [NS]
S&F MS square type structure(2 ft x 2 ft) made up of 40 x 40 x 5 mm MS angle and 40 x 5 mm MS flat incl painting with necy holes, nuts , bolts etc to be fixed with pole cap to be fixed on pole top for fixing three nos 200 watt LED flood light.
Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly
Upto 9.0 mtr. Size 0.6x0.6x1.70 mts [H-1/1(a)]
Extra on items 1& 2 above, for providing CC (6:3:1) base block (around the pole) dimension 0.60x0.60x0.76 mt. above ground level, neatly cemented finish (3 mm thick), at the base pole (in lieu of CC muffing) suitable for alkathene/ polythene pipe entry as directed for street light wiring, incl. S & F 25cmx25cmx10cm GI Loop box, 16SWG & incl. drilled hole in pole
S/F PVC type water proof looping cable box of size 200x150x100mm having hinged top Cover with rubber gasket lining, railway type mechanical locking anangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same on pole above 5ft from ground level by necessary pole clamp .(make-Sintex-GSJB 2014 195X135X90)mm
Painting of Steel Tubular Pole of lengths and no. of coats of paint,as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint
Upto 9.0mtr. Long pole (a)1st coat of aluminium paint over 1 coat of RO priming
Upto 9.0mtr. Long pole (ii) 2nd coat of aluminium paint over 1st coat
Connection between loop box & the HPSV fittings with 2 x 2.5 sq mm PVC insulated copper conductor as to G.S.( for 9 mtr pole)
S & F of MN 16 DOL (09 -15 A Range) (Make-L&T, Cat no.- SS94351) starter on angle iron frame as to GS.
Supply & Fixing 415 V, 11KW ,(14-23A Range) MN 25 DOL Starter on iron legs on wall incl. connection [Make- L& T] (For Compound Light only)
Supply & Fixing 240 V,MF-1 (12-20A range) Starter on iron legs on wall incl. connection [Make- L& T cat no SS97227OOCO] (For Compound Light only)
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below By TATA-M GI pipe.
Excavation of soil for installation of Earth Electrode and filling & ramming. (For Soft Soil)
Extra of treatment of soil by using salt & charcoal for pipe electrode.
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages
No. 10 SWG
Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required
25 mm Dia
40 mm Dia
50 mm Dia
Supply and fixing of three phase timer box recessed in wall, with locking arrangement & DIN Rail consisting of following items including necessary interconnection by suitable size of stranded PVC insulated 1.1 kv grade copper wire after crimping as per direction of EIC and suitable auto-manual bypass arrangement .a) Double door (12) way SPNDB with IP-42/43 protection (Make-Legrand/Hager/ABB). b)DIN mounted Digital/ Analog timer having provision of adjustment 24 hour( Make- L&T / Legrand/ ABB). c) DIN mounted power contractor with 415 volt magnetic coil with 4- pole 63A having 2 NO & 2 No. NC contactor.( Make- L&T / Siemens / Havells / Legrand / Schneider/ABB). d) 4- pole 63 Amp 10 KA DIN mounted FPMCB 'C' curve ( Make- Legrand/ Siemens / L&T / Schneider/ ABB). e) One No. red 240 V LED indicator for indicating Auto & Bypass indication ( Make- L&T / Kayee/ ABB/ Schneider) -- 1 Set.
S/F 250V, 25A timer controller in SS double door 12 way DB enclosure (LT make cat no. LTSD12N) with S/F following electrical accessories & front door locking arrangement with all connection, earthing attachment on wall as per direction of EIC. [For AC Machines] a) 25A DPMCB (LT make ) ------- 1 No b) 24 Hr adjustable Analog timer (LT make )----------- 1 No. c) 2 Pole power contractor (LT Make Cat No. MNX25/230V)with auxiliary contact--------- 1 Nos. d) 25A On-Off-On toggle switch -------- 1 No. e) LED indication lamp ------------ 1 No. (L&T)
S/F of 415V ML2 type star delta starter with relay range 13-21A (Make LTLK,cat no. SS90707COCO)
S/F of 415V 415A Main Switch in sheet steel enclosure having 3 nos HRC fuse as per GS
Arrangement of 3 nos LED Sign Board .
Supply & Installation of 6" depth box type M.S. structure duly fabricated & welded by 40 mm x 40 mm M.S. square pipe 3 mm thick ISI mark frame with back side & four sides covered by 24SWG M.S. sheet including Aluminum channel and fixing arrangement with out ACP sheet including painting. size : 16' x 4'6'' to be made such a manner that it can be opened towards up direction for taking maintenance.
S&F 4 mm thick white ACP sheet on MS structure. Size 16 ft. X 4'6'' 'ft.
Supply & Fixing of special type imported acrylic letter 300 mm height fixed on ACP sheet. The letter font (English & Bengali, Bold) Letter colour = Blue. Encrypted with : BISWA BANGLA LOGO BENGAL SWIMMING ACADEMY. (LOGO) DEPARTMENT OF YOUTH SERVICE & SPORTS GOVERNMENT OF WEST BENGAL 46, SUREN SARKAR ROAD, kOLKATA-700010" NB. SOME MODIFICATION MAY BE REQUIRED AS PER REQUIREMENT OF AUTHORITY END.
Supply fixing of LED inside the acrylic letters. The specification of the LED is given below : A) LED: White- Samsung SMD 5630 (Korea) module: B) Type: Double line fixed C) Life: 70,000 burning hours D) Intensity: Same & smooth throughtout, no brighter or light or dark patches. E) Visibility: 50 mtr. at least for normal eye. F) Power supply: Required AMP (meanwell LRS-<...>-12) G) Ambient Air: 0-50C.100% relative humidity. H) Power Consumption: 1.08 watt per module.
Supply & fixing of logo (12")
M.S. structural works with hollow sections (square or rectangularshape) conforming to IS: 806-1968 & IS:1161-1998) connected toone another with bracket, gusset, cleat as per design, drawing &direction of Engineer-in-Charge complete including cutting torequisite shape & size, fabrication including metal arc weldingconforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidentalchages (such as electricity, labour insurance) etc. complete.Payment to be made on the basis of calculated weight of structuralmemebrs of MS Holow Section as specified in relevent IS code infinished work. Payment for gusset, bracket, cleat may be made byadding the actual weight of such items with weight of finishedstructural members. The rates are considered for a hight of erection8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part there of i)a-- Span upto 12 mtr
M.S. works in brackets made from flats, angles, tees etc. to sizesspecialy bent, twisted, forged; making holes drilled and fitted torafter of trusses with necessary bolts, nuts, washer or screws etc.(length of straight not less than 230 mm)
Holding down bolt with nut including 100 x 100 x 6 mm plate washer at bottom fitted complete and packing the hole with cement concrete or cement grout as directed.(20mm dia bolt 450 mm long)
Providing CC Platform for installation of TOWER with dimension of CC foundation is 1.5feet x 1.5 feet X 5 feet depth after necessary excavation of earth work with Supply and delivery of all raw material i.e. stone chips, sand and cement and the height of platform 0.15 mtr from ground level with 3mm thick neatly finished cement plaster all round as per GS
S/F 250V, 25A timer controller in SS double door 12 way DB enclosure (LT make cat no. LTSD12N) with S/F following electrical accessories & front door locking arrangement with all connection, earthing attachment on wall as per direction of EIC. [For AC Machines] a) 25A DPMCB (LT make cat no. B20250C) ------- 1 No .b) 24 Hr programmable Digital dial timer (LT make CAT no. 67DDT0------------ 1 No. c) 3 Pole power contractor (LT Make Cat No. MNX22/230V)--------- 2 Nos. d) 2 Moduler 25 A AC motor starter (Legrand / Myrius Cat No. 673031) ----------------1 No. e) 25A On-Off-On toggle switch -------- 1 No. f) LED indication lamp ------------ 1 No. (L&T)( For Control of sign board)
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20 mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required.
Supply & Fixing PVC loop box with 32 A three pole terminal and 16A Kit Kat fuse with 02 nos flat iron frame on wall (Make-Sintax.GSJB 2525 /250X200X105 mm)
Taken down the old damaged sign board from its position and to be placed at authrities marked location within 50 mtr area (including loading & unloading charged)
Arrangement of Air-Conditioning System.
Dismantling the existing Air-conditioning system (Split/window type) i.e. indoor unit, outdoor unit, piping, cabling, along with all accessories from its position, storing the same properly in good condition.
R410 A Gas Charging Top Up
S/F of 3 core round copper cable of 2.5 Sq. mm, 5/8 '' & 1/4 '' copper pipe nitrile rubber insulation cover ( Minimum 9 mm thick), 19 mm dia PVC water drainage pipe, insulation tape, fastner, etc as per direction of EIC.
Supply & laying drain Water piping work out of PVC/HDPE hard pipe of 25mm. Dia 4mm thickness ( Make - HB / Supreme) incl fitting, accessories bend, elbows, tees, flanges, tapings, wall sleeves, hangers, supports, anchors etc.
Breazing of copper pipes(1/4" and 1/2") by welding.
Through cleaning of spare parts. Cleaning of housing body, cooling coil and back condencer by coastic soda and refitting the same
Split Type
Leak testing by N2 gas of cooling coil & condenser coil including copper pipes by air pressure and repair.
Re-Installation, testing & commissioning of Split Air Conditioner machine after proper serviving.
TARAKESHWAR ELECTRO ENTERPRISE
R.N.ROY ELECTRICAL CONTRACTOR
C. CHOWDHURY AND CO
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .