Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹2.1 CrAccepted-AOC | ₹2.1 Cr | L-1 | Accepted-AOC Awarded the work with due approval from TPC-1 |
| 2 | L-2₹2.2 Cr+₹5.1 L (2.41%)Rejected-Finance DIGAMBAR CHUCK JORHAT | JORHAT | ₹2.2 Cr+₹5.1 L (2.41%) | L-2 | Rejected-Finance L-2 bidder |
| 3 | Rejected-Technical JUNAKI NAGAR VIP ROAD BORBARI CHARIALI GUWAHATI 36 | GUWAHATI | - | - | Rejected-Technical Non-Responsive |
Tender Value
Refer Docs
EMD Value
₹5.5 L
Closing Date
16 Sept 2019, 12:00 pmClosed
CGM PPD
Office of CGM PPD 6th floor Bijulee Bhawan Paltanbazar Guwahati 781001
Construction of new 11 KV feeders for bifurcation of existing feeders under Mangaldoi Electrical Circle APDCL
2019_APDCL_13992_1
SOPD_19-20/MANGALDOI_3/19
Open Tender
Electrical Works
Turn-key
365 days
Mangaldoi
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,000
APDCL
₹5.5 L
Bijulee Bhawan Guwahati
5 Mar 2020
2 Sept 2019
16 Sept 2019
2 Sept 2019
16 Sept 2019
6 Sept 2019
5 Sept 2019
1) Construction of new 11 kV line from Bheruadol to Lathpara for bifurcation of 11 kV Dhuni feeder by joining with 11 Rajghat feeder originating from 33/11 KV Dipila S/S [Line Length = 1.75 kM] 2) Construction of new 11 kV line from Chengelia to Taragaon for bifurcation of 11 KV Sipajhar feeder along with diverting load from Futukitoli S/S to Dipila S/S by joining 11 kV Chengelia feeder originating from 33/11 kV Dipila Sub-Station [Line Length = 1.65 kM]. 3) Construction of new 11 kV line originating from 33/11 kV Futukitoli S/S for bifurcation of Sipajhar feeder [Line Length = 6.35 kM] 4) Construction of new 11 kV line at Gelabil feeder at Dhunsiri Ghat for bifurcation of Silbori Feeder [Line Length = 2.5 kM] 5) Construction of new 11 kV line from 33/11 kV Udalguri S/S to Bagaribari for load sharing of 11 kV Barnagaon feeder [Line Length = 7.0 kM] 6) Terminal Equipment for new 11 KV feeder emanating from 33/11 KV Futukitoli S/S under Mangaldoi Electrical Circle on full Turn Key basis under SOPD 2019-20 Scheme.
Description of Work / Item(s)
Construction of new 11 kV line from Bheruadol to Lathpara for bifurcation of 11 kV Dhuni feeder by joining with 11 Rajghat feeder originating from 33/11 KV Dipila S/S [Line Length = 1.75 kM]. (BoQ3)
Construction of new 11 kV line from Chengelia to Taragaon for bifurcation of 11 KV Sipajhar feeder alongwith diverting load from Futukitoli S/S to Dipila S/S by joining 11 kV Chengelia feeder originating from 33/11 kV Dipila Sub-Station [Line Length = 1.65 kM]. (BoQ4)
Construction of new 11 kV line originating from 33/11 kV Futukitoli S/S for bifurcation of Sipajhar feeder [Line Length = 6.35 kM]. (BoQ5)
Construction of new 11 kV line at Gelabil feeder at Dhunsiri Ghat for bifurcation of Silbori Feeder [Line Length = 2.5 kM] (BoQ6)
Construction of new 11 kV line from 33/11 kV Udalguri S/S to Bagaribari for load sharing of 11 kV Barnagaon feeder [Line Length =7.0 kM] (BoQ7)
Terminal Equipment for new 11 KV feeder emanating from 33/11 KV Futukitoli S/S (BoQ8)
Description of Work / Item(s)
Supply and of erection of PSC Pole 8.5 mtr with grouting
Supply and erection of ACSR Raccoon Conductor
Supply, Fitting & Fixing of Jointing sleeve for Raccoon
Supply, fitting & fixing of GI Channel Cross arm 100x50x6x2200mm
Supply, fitting & fixing of GI Channel cross arm (75x40x6x2200 mm)
Supply, fitting & fixing of GI Angle (50x50x6 mm) for cross bracing
Supply,fitting & fixing of 11 kV Polymeric Disc Insulator 45 KN, B&S
Supply, fitting fixing of H/W fittings for Disc, B&S, 45 kN, tension type
Supply, fitting & fixing of GI 11kV T-Cross Arm with angle size 50x50x6
Supply fitting & fixing of 11 kV Polymeric Pin Insulator
Supply, fitting & fixing of Pole clamp of GI flat 50x6 mm
Supply, Fitting & Fixing of Eye hook/eye bolt
Supply and erection of HT stay set
Supply, fitting & fixing of Stay wire 7/10 SWG
Supply, fitting & fixing of 11 kV Guy Insulator
Supply,fitting & fixing of GI wire 8 SWG (for guarding)
Supply, fitting fixing of GI barbed wire type A
Supply, fitting & fixing of HT Danger Plate
Supply, fitting & fixing of GI nuts & bolts with washer (assorted)
Description of Work / Item(s)
Supply and of erection of PSC Pole 8.5 mtr with grouting
Supply and erection of ACSR Raccoon Conductor
Supply, Fitting & Fixing of Jointing sleeve for Raccoon
Supply, fitting & fixing of GI Channel Cross arm 100x50x6x2200mm
Supply, fitting & fixing of GI Channel cross arm (75x40x6x2200 mm)
Supply, fitting & fixing of GI Angle (50x50x6 mm) for cross bracing
Supply,fitting & fixing of 11 kV LA, 9KA, station type
Supply, fitting fixing of 11 kV Polymeric Disc Insulator 45 KN, B&S
Supply, fitting & fixing of H/W fittings for Disc, B&S, 45 kN, tension type
Supply fitting & fixing of GI 11kV T-Cross Arm with angle size 50x50x6
Supply, fitting & fixing of 11 kV Polymeric Pin Insulator
Supply, Fitting & Fixing of Pole clamp of GI flat 50x6 mm
Supply, fitting & fixing of Eye hook/eye bolt
Supply, fitting & fixing of HT stay set
Supply, fitting & fixing of Stay wire 7/10 SWG
Supply,fitting & fixing of 11 kV Guy Insulator
Supply, fitting fixing of GI wire 8 SWG (for guarding)
Supply, fitting & fixing of GI barbed wire type A
Supply, fitting & fixing of HT Danger Plate
Supply, Fitting & Fixing of GI nuts & bolts with washer (assorted)
Description of Work / Item(s)
Supply and of erection of GI Steel Tubular Pole SP 66 with grouting
Supply and erection of PSC Pole, 8.5 mtr long with grouting
Supply and erection of ACSR Raccoon Conductor
Supply, fitting & fixing of Jointing Sleeve for Raccoon Conductor
Supply, fitting & fixing of GI Channel cross arm (100x50x6x2200 mm)
Supply, fitting & fixing of GI Channel cross arm (75x40x6x2200 mm)
Supply,fitting & fixing of GI Angle (50x50x6 mm) for cross bracing
Supply, fitting fixing of 11 kV, 9 KA, LA line type
Supply, fitting & fixing of 11 kV Polymeric Disc Insulator 45 KN, B&S
Supply fitting & fixing of H/W fittings for Disc, B&S, 45 kN, tension type
Supply, fitting & fixing of 11 kV Polymeric Pin Insulator
Supply, Fitting & Fixing of Pole clamp of GI flat 50x6 mm
Supply, fitting & fixing of Eye hook GI
Supply, fitting & fixing of HT stay set
Supply, fitting & fixing of Stay wire 7/10 SWG
Supply,fitting & fixing of 11 kV Guy Insulator
Supply, fitting fixing of GI Strip 25x3 mm for earthing
Supply, fitting & fixing of GI wire 8 SWG (for guarding)
Supply, fitting & fixing of GI barbed wire type A
Supply, Fitting & Fixing of 3-ph 4W ICS DLMS compliant HT Trivector energy meter CAT-A
Supply, Fitting & Fixing of Control Copper Cable 10C, 2.5 sq. mm
Supply and erection of 11 kV combined CT PT set with meter cabinet 200/5A
Supply, Fitting & Fixing of Bi-metalic Lug assorted
Supply, Fitting & Fixing of Meter cabinet
Supply, Fitting & Fixing of GI pipe 50 mm dia 3.0 mtr. Length
Supply, Fitting & Fixing of HT Danger Plate
Supply, Fitting & Fixing of GI nuts & bolts with washer (assorted)
Description of Work / Item(s)
Supply and of erection of PSC Pole 8.5 mtr with grouting
Supply and erection of 11 kV D.O fuse set
Supply , fitting & fixing of Pole clamp of GI flat 50x6 mm
Supply, fitting & fixing of GI Channel Cross arm 100x50x6x2200mm
Supply, fitting & fixing of GI 11kV T-Cross Arm with angle size 50x50x6
Supply, fitting & fixing of GI Angle (50x50x6 mm)
Supply,fitting & fixing of 11 kV Polymeric Disc Insulator 70 KN, B&S
Supply, fitting fixing of H/W fittings for Disc, B&S, 70 kN, tension type
Supply, fitting & fixing of 11 kV Polymeric Pin Insulator
Supply fitting & fixing of CI earth pipe, 1.8 mtr
Supply and erection of ACSR Raccoon Conductor
Supply, Fitting & Fixing of GI nuts & bolts with washer (assorted)
Supply, fitting & fixing of HT stay set
Supply, fitting & fixing of Stay wire 7/10 SWG
Supply, fitting & fixing of 11 kV Guy Insulator
Supply,fitting & fixing of GI wire 8 SWG
Supply, fitting fixing of GI barbed wire type A
Supply, fitting & fixing of HT Danger Plate
Description of Work / Item(s)
Supply and of erection of GI Steel Tubular Pole SP 66 with grouting
Supply and erection of PSC Pole, 9.75 mtr long (for bus bars) with grouting
Supply and erection of ACSR Raccoon Conductor
Supply and erection of ACSR Wolf Conductor (for bus)
Supply, fitting & fixing of 11 kV D.O fuse set, 150A
Supply, fitting & fixing of 11 kV G.O.A.B. Switch, 400A
Supply,fitting & fixing of 11 kV G.O.A.B. Switch, 400A (for bus bars)
Supply, fitting fixing of GI Angle (50x50x6 mm) for cross bracing
Supply, fitting & fixing of GI Channel cross arm (100x50x6x2200 mm)
Supply fitting & fixing of GI Channel cross arm (100x50x6x2200 mm) for bus bars
Supply, fitting & fixing of Pole clamp of GI flat 50x6 mm
Supply, Fitting & Fixing of GI Top cleat
Supply, fitting & fixing of 11 kV Polymeric Pin Insulator
Supply, fitting & fixing of 11 kV Polymeric Disc Insulator 45 KN, B&S
Supply, fitting & fixing of H/W fittings for Disc, B&S, 45 kN, tension type
Supply,fitting & fixing of GI pipe 50mm dia 3.0 mtr
Supply, fitting fixing of HT stay set
Supply, fitting & fixing of Stay wire 7/10 SWG
Supply, fitting & fixing of 11 kV Guy Insulator
Supply, Fitting & Fixing of GI wire 6 SWG
Supply, Fitting & Fixing of GI barbed wire type A
Supply, fitting & fixing of 3-ph 4W ICS DLMS compliant HT Trivector energy meter CAT-A
Supply and erection of 11 kV combined CT PT set with meter cabinet 200/5A
Supply, Fitting & Fixing of Bi-metalic Lug assorted
Supply, Fitting & Fixing of Meter cabinet
Supply, Fitting & Fixing of Cu. Control Cable, 10-core, 2.5 sq.
Supply, Fitting & Fixing of Cu. Control Cable, 4-core, 2.5 sq. mm.
Supply and erection of 11 kV outdoor VCB with GI mounting structure and marshalling box
Supply and erection of 11 kV Relay & Control Panel for outdoor VCB (with numerical relay & static TVM)
Supply and erection of 11kV Current transformer outdoor type(CT Ratio 200-100/5-5A) with terminal connector and all accessories, mounting structure & Marshalling box
Supply, Fitting & Fixing of 11kV Isolator, 630A with earth blade complete with GI mounting structure
Supply and erection of 11kV PT with terminal connector and all accessories
Supply, Fitting & Fixing of HT Danger Plate
Supply, Fitting & Fixing of GI nuts & bolts with washer (assorted)
Description of Work / Item(s)
Supply and of erection of 11 kV outdoor VCB with GI mounting structure and marshalling box
Supply and erection of 11 kV Relay & Control Panel for outdoor VCB (with numerical relay & static TVM)
Supply and erection of 11kV Current transformer outdoor type(CT Ratio 200-100/5-5A) with terminal connector and all accessories, mounting structure & Marshalling box
Supply, fitting & fixing of 11 KV GOAB Switch
Supply, fitting & fixing of 11kV Isolator, 630A with earth blade complete with GI mounting structure
Supply, fitting & fixing of GI Channel Cross arm (100x50x6x3200 mm)
Supply,fitting & fixing of GI Channel Cross arm (100x50x6x2200 mm)
Supply and erection of ACSR Raccoon conductor
Supply, fitting & fixing of PG Clamp for Raccoon conductor
Supply fitting & fixing of Cu. Control Cable, 10-core, 2.5 sq.
Supply , fiiting & fixing of Cu. Control Cable, 4-core, 2.5 sq. mm.
Supply, Fitting & Fixing of Cu. Control Cable, 2-core, 2.5 sq. mm.
Supply, fitting & fixing of Cable Tie
Supply, fitting & fixing of GI Strip 50x6 mm
Supply, fitting & fixing of GI wire 6 SWG for earthing
Supply,fitting & fixing of GI pipe 50mm dia 3mtr length
Supply, fitting fixing of GI nuts and bolts with GI washer
SURAJ KUMAR SHARMA
SURAJ KUMAR SHARMA
M/s. Nilgiri Electrical COnstruction
M/s. Nilgiri Electrical COnstruction
SURAJ KUMAR SHARMA
SURAJ KUMAR SHARMA
SURAJ KUMAR SHARMA
M/s. Nilgiri Electrical COnstruction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .