Executive Engineer, Bankura Division, PWD
Office of the Executive Engineer Bankura Division PWD Kenduadihi Bankura
Repair and renovation of damaged ramp at Mother and Child-hub building (towards Cancer building) at Gobindanagar campus of Bankura Sammilani Medical College and Hospital under Bankura Division, PWD. (Civil Work)
2026_WBPWD_984752_4
WBPWD/EE/BANKURA DIVISION/NIT- 17/2025-2026
Open Tender
CIVIL WORKS
Percentage
30 days
Bankura
Please refer Tender documents.
4 documents required · 4 mandatory
₹3,662
10 Feb 2026
7 Jan 2026
29 Jan 2026
13 Jan 2026
27 Jan 2026
13 Jan 2026
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm.
Supplying and laying Polythene Sheet (150 gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or infoundation trenches.
I) Cement concrete with graded stone ballast (40 mm size excluding shuttering). (A) [Pakur Variety] (a) 1:3:6 proportion In Gound Floor
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor). (a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. In Gound Floor
Brick work with 1st class bricks in cement mortar (1:6). (a) In foundation and plinth
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor). [Excluding cost of chipping over concrete surface] (i) With 1:6 Cement mortar (c) 15 mm thick plaster. In Ground Floor
Neat cement punning about 1.5 mm. thick in wall dado, window, sills, floor, drain etc. NOTE: Cement 0.152 cu.m per 100 sq.m.
Supplying and laying chequered tiles of any shade & of approved quality with (1:1½:3) cement concrete laid in panels or patterns as directed in pavement, footpath etc. including necessary underlay 25 mm thick [avg] cement mortar (1:3) complete in all respect with all labour and materials. [Using cement slurry @ 4.4 kg/Sq.m at back side and @2.4 kg/Sq.m for joint filling] Red Variety (ii) 30 mm. thick
Supplying and laying in the specified pattern of Interlocking Concrete Block Pavements (ICBP) with concrete blocks (with concrete grade as specified as per Table 1 of IS 15658:2006) manufactured from BIS licensee manufacturer, with spacer nib (small protruding profiles on the vertical face of a paver block used as a device for keeping minimum joint gap in between the paving blocks, as per Cl. No. 3.26 of IS : 15658) and of specified size and shape with aspect ratio (The ratio of length to thickness of a paver block, as per Cl. No. 3.3 of IS: 15658) as per Table 2 of IS : 15658 with flexural strength/breaking load as per annexure G of IS: 15658, on the prepared base course of specified CBR as per Table 1 of IRC SP 63 (2018) or else as mentioned in design and drawing with a cushion of compacted bedding sand of 25-35 mm thick (grading of the bedding sand as per clause 6.5.1 of IRC SP 63) and filling up the gaps in between paver blocks with joint filling sand (the grading of the joint filling sand will be as per clause 6.5.2 of IRC SP 63) and completing the edges with cut blocks as per Cl. No. 8.7 of IRC SP-63(2018) with proper confinement of bedding and joint filling sand compacting levelling and filling up of the edge gap. 60 mm thick. (ii) Coloured decorative
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. In Ground Floor: (b) Two coats
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. (Two Coat) b) Premium 100% Acrylic Emulsion
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.11 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.94 MB
2911-ii.pdf
Tender Documents • 0.58 MB
BOQ_2403231.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .