SITC OF 5 STAR RATED INVERTER SPLIT AC UNITS WITH
6268559
GEM/2024/B/4821809
Two Packet Bid
Supply of BEE approved 1.5TR 5 Star rated Inverter Split AC units,Installation testing and commissi
60 days
Odisha; Khordha
Total value wise evaluation
BOQ
11 documents required · 11 mandatory
3 yrs
₹3
80%
₹55,812
10 Apr 2024
27 Mar 2024
10 Apr 2024
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) |
|---|---|---|---|---|---|---|
| 1 | Supply of BEE approved 1.5TR 5 Star rated Inverter Split AC units | Supplying of BEE approved 1.5 TR 5 Star rated Inverter or dual inverter type split Air Conditioning unit having nominal rated cooling capacity not less than 5100 watts with copper Evaporator and Condenser coil and Rotary Compressor suitable for operation on single phase 230 V plus or minus ten percentage 50 Hz AC supply minimum room air flow 500 CFM and minimum Indian Seasonal Energy Efficient Ratio ISEER 5 point 2 filled with R32 or R410A refrigerant gas with installation kit comprising of standard lengths of copper refrigerant pipes PU or foam insulation drain pipe and interconnection copper cable etc complete as reqd. Note. The manufacturers or suppliers shall give a warranty of the air conditioner for 15 months from date of supply or 12 months from date of installation whichever is earlier. Thereafter 4 years or 48 months additional warranty on PCB for both Indoor and Out door printed circuit board card and 9 years or 108 months additional warranty on the compressor. | 50 | Number | bsnl00006185 | 60 |
| 2 | Installation testing and commissioning of 1.5TR Inverter Split AC units | Installation and testing and commissioning of 1.5 TR Split A.C. Unit and mounting or Fixing of indoor and outdoor unit and fixing of refrigerant piping with expanded polythene foam insulation and laying of cable for interconnections and laying drain pipe of standard length which is supplied along with AC unit with minor civil work including making holes on wall for laying refrigerant pipe lines control cable and drain pipes and closing the extra openings with cement sand and making good the damages etc. as reqd. The Extra length of Refrigerant piping and cable shall be paid extra. | 50 | Number | bsnl00006185 | 60 |
| 3 | Providing and fixing of powder coated MS bracket for installation of condenser units | Providing and fixing of suitable size L shaped powder coated MS bracket with 2 nos. per set for fixing of the outdoor unit of the split AC units and fixing on wall with anchor bolts and drilling holes etc. complete as reqd. | 50 | Set | bsnl00006185 | 60 |
| 4 | Providing and laying of additional copper refrigerant pipes with expanded polythene foam insualtions | Providing and laying of additional refrigerant copper pipe for suction and discharge line with size not less than 1 by 4 inch and 1 by 2 inch dia or as recommended by the manufacturer along with expanded polythene foam insulation including cutting brazing and making joint etc as reqd. The measurement shall be taken on linear basis for one circuit which includes suction and discharge line and foam insulation. | 150 | Mtr | bsnl00006185 | 60 |
| 5 | Supply and laying of Extra Electric cables for interconnection of indoor and out door units | Supplying and laying of Extra Electrical cable of 3 core 2.5 sqmm PVC insulated and sheathed copper for electrical connection of AC units etc as reqd. Make Finolex or L and T or Polycab or Havells. | 150 | Mtr | bsnl00006185 | 60 |
| 6 | Supply and laying of Extra Electric cables for extending power supply to AC point. | Supplying and laying of Extra Electrical cable of 4 core 2.5 sqmm PVC insulated and sheathed copper for electrical connection of indoor and outdoor units of ACs etc as reqd.Make Finolex or L and T or Polycab or Havells. | 150 | Mtr | bsnl00006185 | 60 |
| 7 | Providing and laying of additional drain pipes | Providing and laying of additional drain pipe of size 25mm dia polythene or U PVC M class ISI marked pipe along with all accessories and fixing on surface of wall with saddles or C clamps if required suitable for drainage of condensate water etc. as reqd. | 150 | Mtr | bsnl00006185 | 60 |
| 8 | Providing and charging of extra Refrigerant gas | Providing of additional R32 or R410A refrigerant gas if required and charging or top up into the Split AC units etc. as reqd. | 15 | Kg | bsnl00006185 | 60 |
| 9 | Supply and fixing of MCB protected socket outlet AC control box with socket MCB and plug top | Supply and Fixing of MCB protected 3 pin socket outlet box with metal board consisting of 1 no 20 Amps 3 pin socket outlet with 20 Amps plug top and 1 no 20 or 25 amps SP MCB of C series suitable for 220 to 230 volts single phase 50 Hz AC supply as required. | 30 | Number | bsnl00006185 | 60 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_6268559.pdf
GEM_BID
kptsacadspec_2024-03-27-19-02-44_6151b3149b4f8f063cce880f52648b83.pdf
BOQ
boq_item_sample_file_2024-03-27-19-02-44_4e7a191cff6fd9de297e9e13a54cf053.csv
BOQ
ATCKPTSAC_0d27e217-6c48-45c3-9e9e1711552587689_bsnl00006890.pdf
OTHER
gtc.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .