Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.1 LAccepted-AOC 205 IIND PHASE INDUSTRIAL AREA BARMER 344001 | BARMER | BARMER | RAJASTHAN | 344001 | L1 | Accepted-AOC AOC | |
| 2 | L2₹25.4 L+₹60,701 (2.45%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹30.1 L+₹5.3 L (21.5%)Rejected-Finance 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 | BHAVNAGAR | GUJARAT | 364001 | L3 | Rejected-Finance Other than lowest | |
| 4 | Rejected-Technical MAHAVEER NAGAR BARMER RAJASTHAN 344001 MAHAVEER NAGAR BARMER RAJASTHAN 344001 | BARMER | RAJASTHAN | 344001 | - | Rejected-Technical Not approved | |
| 5 | Rejected-Technical 06 KHASRA NUMBER 56 KIRAN NAGAR BASNI JODHPUR JODHPUR RAJASTHAN 342001 UDYAM RJ 22 0002214 | JODHPUR | RAJASTHAN | 342001 | - | Rejected-Technical Not Approved |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
9 Apr 2024, 6:00 pmClosed
GE (AF) Utarlai
GE (AF) Utarlai PB No.11 Barmer 344001 (Raj)
REPAIR/ REPLACEMENT OF WATER SUPPLY DIST NETWORK AND ANTI FLOOD PUMPSET , LT PANEL AND CONNECTED ITEMS AT AF STN UTARLAI
2024_MES_646131_1
8463/E8
Open Tender
Civil Works
Item Rate
180 days
Utarlai
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) Utarlai
₹64,000
Yes
26 Jun 2024
12 Mar 2024
11 Apr 2024
13 Mar 2024
9 Apr 2024
26 Mar 2024
Amount
Material and labour for repairing/servicing the Electric induction motor and centrifugal pump coupled type by carefully disconnecting the connection cables and earthings, removing side covers, greasing wherever necessary, changing of defective minor parts and re-assembling, testing of capacity 50 to 75 HP to the satisfaction of Engr-in-Charge.
M & L for rewinding of submersible motor of capacity 1 HP 230 V capacity with super enamelled copper conductor of same guage weight and turns to achieve its full efficiency including tying the windings and connecting the coils and bringing the connections as that of exisitng complete including replacement of worn out/unserviceable bearings and water seal etc all as specified and directed by the Eng-in-Charge. Note: (i) The rate of transportation from site to workshop and back is deemed to be included in the rate quoted by contactor. (ii) The rent of T&P for handling the pump motor assembly during dismantling and refixing is deemed to be included in the rate quoted by contatcor.
M & L for luring & taking out from sump of submersible motor of capacity 1.5 to 2 HP 230V capacity with super enamelled copper conductor of same guage weight and turns to achieve its full efficiency including tying the windings and connecting the coils and bringing the connections as that of exisitng complete including replacement of worn out/unserviceable bearings and water seal etc all as specified and directed by the Eng-in-Charge. Note: (i) The rate of transportation from site to workshop and back is deemed to be included in the rate quoted by contactor. (ii) The rent of T&P for handling the pump motor assembly during dismantling and refixing is deemed to be included in the rate quoted by contatcor.
M & L for rewinding of submersible motor of capacity 3 to 5 HP 415 V capacity with super enamelled copper conductor of same guage weight and turns to achieve its full efficiency including tying the windings and connecting the coils and bringing the connections as that of exisitng complete including replacement of worn out/unserviceable bearings and water seal etc all as specified and directed by the Eng-in-Charge.Note: (i) The rate of transportation from site to workshop and back is deemed to be included in the rate quoted by contactor. (ii) The rent of T&P for handling the pump motor assembly during dismantling and refixing is deemed to be included in the rate quoted by contatcor.
M & L for rewinding of submersible motor of capacity 7.5 HP 415 V capacity with super enamelled copper conductor of same guage weight and turns to achieve its full efficiency including tying the windings and connecting the coils and bringing the connections as that of exisitng complete including replacement of worn out/unserviceable bearings and water seal etc all as specified and directed by the Eng-in-Charge. Note: (i) The rate of transportation from site to workshop and back is deemed to be included in the rate quoted by contactor. (ii) The rent of T&P for handling the pump motor assembly during dismantling and refixing is deemed to be included in the rate quoted by contatcor.
M & L for rewinding of submersible motor of capacity 10 HP 415 Vcapacity with super enamelled copper conductor of same guage weight and turns to achieve its full efficiency including tying the windings and connecting the coils and bringing the connections as that of exisitng complete including replacement of worn out/unserviceable bearings and water seal etc all as specified and directed by the Eng-in-Charge. Note: (i) The rate of transportation from site to workshop and back is deemed to be included in the rate quoted by contactor. (ii) The rent of T&P for handling the pump motor assembly during dismantling and refixing is deemed to be included in the rate quoted by contatcor.
Supply calcium based high strength granular chlorination chemical a white off white free flowing granular material which is free of foreign materials decompising at 177 degree C soluble in water and alcohol not hygroscopic practically clear in water solution auration level. The material should not contain more than 5% to 10% moisture. Granular should be as mesh passing through 100BS 1.5% maximum iron as Fe 0.05% maximum Mn 40 PPM maximum Mol wt 142.98, Toxicity: Oral rate LD 50-850mg/Kg. Make : Approved by AHQ E-in-c's Branch New Delhi/Zonal Chief Engineer
Cutting green growth / vegetation growth for cleaning out the area by cutting up root, unwanted plants/bushes and removal the same to a distance not less than 50 mtr directed by Engineer-in-Charge.
Cleaning of Semi U/G sump of capacity 300000 Gln, dewatering the tank below the suction pipe with submersible pump with suitable arrangements, desilting and removing of left over water from bottom, cleaning tank surfaces by using bleaching powder approx 80 Kg and remove all foreign materials and clean with plain water and then after cleaning making white wash of the inner surface with the lime complete all as directed by the Engineer-in-Charge. Note:- (i) The job shall be completed within 8 hrs to avoid any interruption in distribution of water supply (ii) The date of cleaning and due date should be written legible on the surface of the tank/sump as per existing old colour and font size.
Cleaning of Semi U/G sump of capacity 200000 Gln, dewatering the tank below the suction pipe with submersible pump with suitable arrangements, desilting and removing of left over water from bottom, cleaning tank surfaces by using bleaching powder approx 60 Kg and remove all foreign materials and clean with plain water and then after cleaning making white wash of the inner surface with the lime complete all as directed by the Engineer-in-Charge. (i) The job shall be completed within 8 hrs to avoid any interruption in distribution of water supply (ii) The date of cleaning and due date should be written legible on the surface of the tank/sump as per existing old colour and font size.
Cleaning of U/G sump of capacity 150000 Gln, dewatering the tank below the suction pipe with submersible pump with suitable arrangements, desilting and removing of left over water from bottom, cleaning tank surfaces by using bleaching powder approx 50 Kg and remove all foreign materials and clean with plain water and then after cleaning making white wash of the inner surface with the lime complete all as directed by the Engineer-in-Charge. (i) The job shall be completed within 8 hrs to avoid any interruption in distribution of water supply (ii) The date of cleaning and due date should be written legible on the surface of the tank/sump as per existing old colour and font size.
Cleaning of U/G sump of capacity 75000 Gln, dewatering the tank below the suction pipe with submersible pump with suitable arrangements, desilting and removing of left over water from bottom, cleaning tank surfaces by using bleaching powder approx 30 Kg and remove all foreign materials and clean with plain water and then after cleaning making white wash of the inner surface with the lime complete all as directed by the Engineer-in-Charge. (i) The job shall be completed within 8 hrs to avoid any interruption in distribution of water supply (ii) The date of cleaning and due date should be written legible on the surface of the tank/sump as per existing old colour and font size.
Cleaning of U/G sump of capacity 50000 Gln, dewatering the tank below the suction pipe with submersible pump with suitable arrangements, desilting and removing of left over water from bottom, cleaning tank surfaces by using bleaching powder approx 25 Kg and remove all foreign materials and clean with plain water and then after cleaning making white wash of the inner surface with the lime complete all as directed by the Engineer-in-Charge. (i) The job shall be completed within 8 hrs to avoid any interruption in distribution of water supply (ii) The date of cleaning and due date should be written legible on the surface of the tank/sump as per existing old colour and font size.
Cleaning of U/G sump of capacity 30000 Gln, dewatering the tank below the suction pipe with submersible pump with suitable arrangements, desilting and removing of left over water from bottom, cleaning tank surfaces by using bleaching powder approx 25 Kg and remove all foreign materials and clean with plain water and then after cleaning making white wash of the inner surface with the lime complete all as directed by the Engineer-in-Charge. (i) The job shall be completed within 8 hrs to avoid any interruption in distribution of water supply (ii) The date of cleaning and due date should be written legible on the surface of the tank/sump as per existing old colour and font size.
Cleaning of U/G sump of capacity 3000 to 10000 Ltr, dewatering the tank below the suction pipe with submersible pump with suitable arrangements, desilting and removing of left over water from bottom, cleaning tank surfaces by using bleaching powder approx 20 Kg and remove all foreign materials and clean with plain water and then after cleaning making white wash of the inner surface and outer surface with the lime complete, all as directed by the Engineer-in-Charge. (i) The job shall be completed within 8 hrs to avoid any interruption in distribution of water supply (ii) The date of cleaning and due date should be written legible on the surface of the tank/sump as per existing old colour and font size.
Cleaning of OH tank of capacity 20000 Gln first with plain water and then with the bleaching powder minimum 50 Kg after cleaning making white wash of the inner surface with the lime complete all as directed by the Engineer-in-Charge.(i) The job shall be completed within 8 hrs to avoid any interruption in distribution of water supply (ii) The date of cleaning and due date should be written legible on the surface of the tank/sump as per existing old colour and font size.
Cleaning of OH tank of capacity 50000 Gln first with plain water and then with the bleaching powder minimum 50 Kg after cleaning making white wash of the inner surface with the lime complete all as directed by the Engineer-in-Charge.(i) The job shall be completed within 8 hrs to avoid any interruption in distribution of water supply (ii) The date of cleaning and due date should be written legible on the surface of the tank/sump as per existing old colour and font size.
Cleaning of PVC tank of capacity 5000 Ltr, dewatering the tank, desilting and removing of left over water from bottom, cleaning tank surfaces by using bleaching powder approx 5 Kg and remove all foreign materials and clean with plain water all as directed by the Engineer-in-Charge. (i) The job shall be completed within 8 hrs to avoid any interruption in distribution of water supply (ii) The date of cleaning and due date should be written legible on the surface of the tank/sump as per existing old colour and font size.
Excavation in trenches as in hard / dense soil, not exc 1.5 mtr wide and not exc 1.5 mtr depth for laying of GI/CI pipe lines etc getting out including forming bottom surface to required level and gradient all as specified and directed by Engineer-in-Charge.
Returning, filling in excavated soil including spreading leveling, watering, well ramming in layers not exc 25 cm thick complete, all as specified and directed by Engineer-in-Charge.
Removing of excavated materials not exceeding 50 Mtrs and depositing at a level not exceeding 1.5 M above the starting point, all as specified and directed by Engineer-in-Charge.
Taking up or down GI water tubing and connections complete all as specified and directed for the following sizes :- Note: Excavation shall be measured and paid seperately
15mm dia bore
20mm dia bore
25mm dia bore
40mm dia bore
50mm dia bore
80mm dia bore
Taking up or down CI/DI pipe line and connections complete all as directed by the Engineer-in-Charge for the following sizes :- Note: Excavation shall be measured and paid seperately
100 mm bore
150 mm bore
Refixing old GI tubing and connections in new or old position (Walls, ceiling,floors, etc) steel water tubing including all suitable fittings fixture i.e. socket, bend tee, union, D joints for tapping/ extension of cable and connections complete all as specified and directed for the following sizes :- Note: Excavation shall be measured and paid seperately
15mm dia bore
20mm dia bore
25mm dia bore
40mm dia bore
50mm dia bore
80mm dia bore
Relaying of DI/CI pipe line and connections complete all as directed by the Engineer-in-Charge for the following sizes :- Note: Excavation shall be measured and paid seperately including suitable size D joint required
100 mm bore
150 mm bore
S&F GI pipe, medium grade ISI mark with all fittings laid in trenches complete all as specified and as directed for the following sizes:-
15mm dia bore
20mm dia bore
25mm dia bore
40mm dia bore
50mm dia bore
80mm dia bore
Supply and laying DI pipe (Ductile iron pipe) spigot and socket ends, class "K-9" with rubber gasket (tighten joint) , laid in trenches including necessary cut to length to match the existing fitting/pipes or insertion of new DI specials complete all as specified and directed by the Engineer-in-charge for the following sizes :- Note: DI specials shall be measured and paid seperately
100 mm bore
150 mm bore
Supply and fix, in repair of Gun - metal globe or gate valve with iron wheel head, screwed both ends for iron pipes and for unions and fixing including taking down existing unserviceable valves complete all as specified and directed for following sizes:-
50mm dia bore
40mm dia bore
25 mm dia bore
20mm dia bore
15 mm dia bore
Material and labour for DI specials such as bends, tees, collars, tail pieces, straight/angle connecting pieces any type (flanged ends, socketed ends or flanged/socketed ends) complete suitable for DI mains of sizes upto 300 mm complete all as specified and directed.
Repair,maintenance and servicing of pressure switch including dismantling, cleaning the dust deposits, greasing, checking for wear and tear, refixing, testing, installing and commissioning all as specified and directed by Engr-in-Charge.
Repair,maintenance and servicing of solenoid valve 15mm dia 230V AC including dismantling, cleaning the dust deposits, greasing, checking for wear and tear, refixing, testing, installing and commissioning all as specified and directed by Engr-in-Charge.
Repair,maintenance and servicing of solenoid valve 25mm dia 230V AC including dismantling, cleaning the dust deposits, greasing, checking for wear and tear, refixing, testing, installing and commissioning all as specified and directed by Engr-in-Charge.
Repair,maintenance and servicing of motorised butterfly valve of size 80mm dia including dismantling, cleaning the dust deposits, greasing, checking for wear and tear, refixing, testing, installing and commissioning all as specified and directed by Engr-in-Charge.
Repair,maintenance and servicing of motorised butterfly valve of size 150mm dia including dismantling, cleaning the dust deposits, greasing, checking for wear and tear, refixing, testing, installing and commissioning all as specified and directed by Engr-in-Charge.
S&F in repairs coil for solenoid valve 15mm dia 230V AC, direct acting/diaphragm type, pilot operated solenoid valve for air release of size 15mm dia, pressure 6 Kg/Sqcm, coil power 6W.
S&F in repairs coil for solenoid valve 25mm dia 230V AC, direct acting/diaphragm type, pilot operated solenoid valve for air release of size 15mm dia, pressure 6 Kg/Sqcm, coil power 6W.
S&F in repairs of relay card 1 C/O, 24V DC all as specified and directed
S&F in repairs of relay with base 2 C/O 240V AC all as specified and directed
S&F in repairs of 22mm LED indicator colour Red,Yellow,Green complete all as specified and directed.
S&F in repairs of 10mm LED indicator colour Red,Yellow,Green complete all as specified and directed.
S&F in repairs of push button with LED indicator 220V AC. Colour: Red/Yellow/Green.
S&F in repairs of SMPS input 230V AC, output 24 V DC complete all as specified and directed.
S&F in repairs ultrasonic level transmitter at sump and over head tank for measurement of level of range 0-5 metres, accuracy 0.5% minimum, supply voltage 24V DC, output 4-20mA, 0-10V DC.
S&F in repairs power contactor 9A 3 pole complete all as specified. Make: L&T/Schneider/ Siemens
S&F in repairs of limit switch for actuator of size 80/150mm bore valves complete al as specified and directed.
Blank
Supply and fixing in repairs of 4 core 1.5 sqmm PVC sheathed PVC insulated copper cable.
Supply and fixing in repairs of 6 core 1.5 sqmm PVC sheathed PVC insulated copper cable.
M&L for 'B' check for maintenance 160 KVA DG Set as per the recommendations of manufacturer (OEM) including renewal of necessary recommended filters, engine oil, 'O' rings etc., complete all as directed by Engineer-in-charge. Note: Engine oil will not be supplied by MES
M&L for 'B' check for maintenance 200 KVA DG Set as per the recommendations of manufacturer (OEM) including renewal of necessary recommended filters, engine oil, 'O' rings etc., complete all as directed by Engineer-in-charge. Note: Engine oil will not be supplied by MES
Repair & Calibration of Self Starter including re-winding of Commutator, replacing Carbon brush set, carbon brush holder, King Pins Holders, armature check nuts, body screws, clutch plate assembly and solenoid etc. as required for the capacity of 160 to 200 KVA DG Set complete all as specified and directed.
Removing the fuel pump and fuel injectors of the DG Set 160 to 200 KVA, servicing the pump, overhauling and calibrating the injectors, fixing back, connecting, priming and commissioning in the engine including replacing rocker cover gaskets etc. all as directed.
Decarburizing/cleaning complete Control panel of DG set 160 to 200 KVA by cleaning bus bar chamber with suitable chemical and ensure proper decarburizing, internal wiring and replacing the damaged wires of existing size, refixing the same after applying suitable solution to the bus bar insulator & checking all the connections, tightening the nuts, bolts & thimbles of in-coming/out-going system complete incl replacement of defective rusted bolts & nuts, repairing to door/ shutter hinges and locking arrangements all a directed by Engr-in-Charge all as specified and directed.
Chemical & bacteriological analysis of treated water from Govt. agency/recognized / authorized testing laboratory as and when recommended by the Engineer - in- charge.
M&L for attending to break down of 200 to 350mm dia DI pipe line bursting/cracks including necessary excavation, dewatering the water accumulated at site, removal of broken pipe pieces of various lengths through gas cutting/manual cutting as per site requirement including removing out the damaged DI pipe and inserting necessary DI specials such as collar, nipple etc as required at site and providing of new joints as required at site, clamping arrangements, PCC 1:3:6 type C-2 using 20mm graded stone aggregate work including testing for the leakages pipes complete all as specified and directed by Engineer-in-Charge. Note:-fitting & joint will be measured separately.
Material and labour for repairing/servicing the 3 phase 415V Electric induction motor and centrifugal pump coupled type by carefully disconnecting the connection cables and earthings, removing gland cover, filling the gland properly,greasing the necessary parts as required, changing of defective copper lugs of cable in pump/motor of capacity 40 HP to the entire satisfaction of Engr-in-Charge.
All as per serial item No. 57 here-in-before but monoblock pump 20 HP
All as per serial item No. 57 here-in-before but monoblock pump 12.5 HP
M&L for Rewinding of burnt out motor of capacity 20 HP 415 V by dismantling of motor, cutting and taking out burnt stator winding from motor cleaning the stator and rewinding with super enamelled copper wire of original gauge/size including tapping varnishing, drying, painting, assembling and complete necessary connection, commissioning and testing on full load. Note :- (i) Cost of minor spare parts deemed to have been included in quoted rates. (ii) The rate of transportation from site to workshop and back is deemed to be included in the rate quoted by contactor. (iii) The rent of T&P for handling the pump motor assembly during dismantling and refixing is deemed to be included in the rate quoted by contatcor.
All as per serial item No. 60 here-in-before but monoblock pump 12.5 HP
All as per serial item No. 60 here-in-before but monoblock pump 3 HP
All as per serial item No. 60 here-in-before but monoblock pump 2 HP 230V
Supply and fixing in repair of CI sluice valve with drilled flanged ends, stainless steel spindle with gun metal working parts with hand wheel, pressure type PN 1.0 including disconnection and removing the unserviceable sluice valves from the existing pipe line/valve chamber for the following sizes complete all as directed by the Engineer-in-Charge :-
80mm bore
100 mm bore
150mm bore
200mm bore
M & L for road/path cutting for laying of GI/DI pipes upto required depth n. exc 1.5 mtr complete all as directed by Engineer-in-Charge.
M&L for rectification of existing defective run lead joints including burning and removing the old defective lead joints and providing new lead joints with all required materials and testing the joints for leakages of the following pipes complete including excavation, returining and filling etc.all as directed by Engineer-in-charge.
150mm dia bore CI pipe
100mm dia bore CI pipe
S&F in repair saddle piece made out of MS flat iron of size 50 x 6mm duly welded with 25 to 50mm dia GI socket and 2 Nos nut/bolts of suitable size/length, necessary rubber packing for branch connections for the sizes of 80 to 150mm dia CI/DI mains complete including necessary earth work all as directed by the Engineer-in-Charge
Supply and fixing in repair of CI butterfly valve, heavy duty with necessary packing materials, nut/bolts & washers etc including disconnection and removing the unserviceable butterfly valve from the existing pipe line/valve chamber for the following sizes complete all as directed by the Engineer-in-Charge:-
80mm bore
100mm bore
150mm bore
Dismantling the old valve pit chamber and construct valve chamber 1000x1000x1000 mm (internal ) with PCC block masonary valve chamber, PCC foundation, plastering and necessary earth work in hard/ dense soil, MS sheet cover 3.15 mm thickness along with angle iron frame of size 40 x 40 x 6mm with locking arrangement with necessary fixing materials like hinges, nut/bolts etc (valve chamber cover shall be opened in two halves) and painting to MS cover with one coat of red oxide and two coats of synthetic enamel paint etc all as specified and directed by Engineer-in-Charge.
All as per item No. 71.00 above but size of valve chamber is 1200x1200x1200mm (internal)
M & L for road/path cutting for laying of GI/DI pipes upto required depth n. exc 1.5 mtr complete all as directed by Engineer-in-Charge.
M & L for boring of holes 150mm dia under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine complete all as directed by Engineer-in-Charge.
M & L for cement concrete in road surfacing, filling and mass concrete type B1, 1:2:4 (20mm graded stone aggregate) for repairs to road cutting for laying of pipe lines/complete all as directed by Engineer-in-Charge.
Supply and replacement in repair of CI foot valve 80mm dia ISI marked with all fittings complete all as directed by the Engineer-in-Charge
Supply and replacement in repair of PVC foot valve 50mm dia ISI marked with all fittings complete all as directed by the Engineer-in-Charge
Supply and replacement in repair of PVC foot valve 40mm dia ISI marked with all fittings complete all as directed by the Engineer-in-Charge
Supply and replacement in repair of PVC foot valve 25mm dia ISI marked with all fittings complete all as directed by the Engineer-in-Charge
Supply and replace in repair of ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of size 50mm dia with complete accessories all as directed. Make : Prayag/Water-Tec (Polytub) or Equivalent
All as per item No.78 above but of size 40mm dia
All as per item No.78 above but of size 25/20mm dia
Material and labour for repairing of valve pit chamber of any size by taking down the old plaster and 10mm thick in 1:4 mixed with water proof liquid in complete surface of valve pit and preparing of old steel surfaces and painting to MS cover with one coat of red oxide and two coats of synthetic enamel paint including removing debris/ sludge etc from valve chamber all as specified and directed by Engineer-in-Charge.
Material and labour for repairing of valve pit chamber of any size by taking down the old plaster and 10mm thick in 1:4 cement plaster in complete surface of valve pit and preparing of old steel surfaces and painting to MS cover with one coat of red oxide and two coats of synthetic enamel paint including removing debris/ sludge etc from valve chamber all as specified and directed by Engineer-in-Charge.
S & F of shock treatment chart all as specified and directed by engineer-in- charge.
S & F of operational procedure working of pump house on flexi banner of 24 inch x12 inch all as specified and directed by engineer-in- charge.
S & F of schmatic diagram with wooden framing of pump house on flexi banner of 4 feet x 3 feet all as specified and directed by engineer-in- charge.
S & F of Rubber mating for LT sample as per existing all as specified and directed by engineer-in- charge.
M & L for painting of motor and pumps all as specified and directed by engineer-in- charge.
S & F steel name plate of 6 inch x10 inch for fixing on motor and writing of MES No. / Sm No. of pump motor of all as specified and directed by engineer-in- charge.
Devi Engineeing
KRISHNA CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .