Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.5 CrAccepted-AOC | ₹4.5 Cr Quoted ₹5.0 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹5.7 Cr+₹71.1 L (14.3%)Rejected-Finance | ₹5.7 Cr+₹71.1 L (14.3%) | L2 | Rejected-Finance L2 |
Tender Value
₹4.0 Cr
EMD Value
₹7.9 L
Closing Date
1 Mar 2024, 9:00 amClosed
ANKIT BHARDWAJ
Division FMDA
Master Sewerage Scheme Faridabad- Repair and rehabilitation of IPS sec-33 and sec-37 Kanishka Tower of Badshahpur Zone, Faridabad and all other works contingent thereto.
2024_HRY_353292_1
20247CC25C1A 17F8 49D7 99FF 1511078DD7FF1851002
Open Tender
Civil Works
Works
180 days
Faridabad (MC)
2 documents required · 2 mandatory
₹1,180
₹7.9 L
Yes
HSIIDC Office Complex, Sector-69, IMT Faridabad
24 Jun 2024
10 Feb 2024
1 Mar 2024
10 Feb 2024
1 Mar 2024
10 Feb 2024
19 Feb 2024
Amount
Supply and Erection of PC batten /LED batten (20Wattage, 3000kCCT) , Product dimension in mm (1140x23x38) for surface and suspended applications. PC housing with PC diffuser and spring steel clamps for surface mounting arrangement.
Supply installation testing and commissioning of Pressure/Vacuum Gauge (-760 mmHG to 0) Bourdon Type SS Body 4 Inch Bottom Connection Glycerin Filled
Supply installation testing and commissioning of 25A Phase Corrector for Transformer
Supply installation testing and commissioning of 50A Phase Corrector for Pumps
Supply installation testing and commissioning of 10 Sqmm Aluminium 4 core armoured Cable.
Supply installation testing and commissioning of 70 watt LED street light (70Wattage, 5700k CCT) , Product dimension in mm (362x232x72)
Supply installation testing and commissioning of LED Post top 20watt street light (20Wattage, 5700k CCT) , Product dimension in mm (330x330x405)
Supply and erection of DN 600 PN 10 Electromagnetic flowmeter (600mm) for sewage water Technical Specifications for Electromagnetic Flowmeter Process Data Fluid : Sewage Water Operating Pressure : Please Specify Operating Temperature : 50 Deg. C. Electromagnetic Flow Sensor Model : Optiflux 2000 Type : Pulsed DC Meter size : Refer table below Flow tube : SS 304 Coil housing : Fully welded Sheet Steel, PU coated Liner : Hard Rubber Electrodes : SS 316 Grounding type : Rings Grounding ring material : SS 316 Process connection : Flanged to DIN PN10 (fully welded) Flanges : CS, SORF Area classification : Non-Hazardous Cable entry : M20 x 1.5 Protection class : IP 67 Electromagnetic Signal Converter Model : IFC 100 Cable length : 20 Meters. Mounting : Remote wall mounted Output : 4-20mA, HART plus Pulse/Frequency plus Status Accuracy : ± 0.5% of measured value Display : Large back lit LCD Display, fully programmable Parameters : Actual flow rate, totalized flow (10 digit), flow direction, flow velocity, conductivity, mass flow rate (at constant density) Diagnostics : Empty pipe detection, Electrode error, Noise, Coil temperature, Coil resistance, Conductivity etc Power supply : 85-250VAC, 48-63Hz Housing : Die cast Aluminium with PU finish Cable entry : M20 x 1.5 Area classification : Non-Hazardous Protection class : IP 67 Accessories : NA
Supply installation testing and commissioning of Horizontal dewatering motor Pump set of 2.5HP for sewer disposal/ Intermediate Pumping Station Approved make as per satisfaction of Engineer- in-Charge complete in all respect.
Supply installation testing and commissioning of mechanical coarse bar screen CW: 1000 mm CD: 4000 mm WD: 1500 mm Bar Spacing: 20 mm Bar Size: 10x50 mm Inclination: 75degree MOC: SS-304 alongwith Panel and Sensor for sewer disposal/ Intermediate Pumping Station Approved make as per satisfaction of Enginee- in-Charge complete in all respect.
Supply installation testing and commissioning of mechanical coarse bar screen CW: 1500 mm CD: 8000 mm WD: 1500 mm Bar Spacing: 20 mm Bar Size: 10x50 mm Inclination: 75degree MOC: SS-304 alongwith Panel and Sensor for sewer disposal/ Intermediate Pumping Station Approved make as per satisfaction of Engineer- in-Charge complete in all respect.
Supply installation testing and commissioning of SS body control Panel for sewer disposal/ Intermediate Pumping Station Approved make as per satisfaction of Engineer- in-Charge complete in all respect.
Supply installation testing and commissioning of Belt Conveyor for sewer disposal/ Intermediate Pumping Station Approved make as per satisfaction of Engineer- in-Charge complete in all respect.
Supply Installation Testing and Commissioning of rising spindle flush bottom CI Sluice Gate size(1000mmx1000mm) generally conform to IS:133-19 material detail 1 Frame, door, guide, extension, wedge, wall thimble, floor standard. CI. to IS 210 Gr. Fg 260 2 Spindle SS: 304 3 Seating faces SS :304/SSCF8 4 Wedge Block DI with SS AISI: 304/CF8 Lining 5 Lift Nut High ternide brass(HT2) 6Fastner (Thimble/Adjustable wedge) Stainless steel 7. Other fastners Carbon steel 8 Extension spindle SS: 304 9 Guide bracket CI to IS.210 Gr. Fg.260 10. Coupling SS AISI: 304 for sewer disposal/ Intermediate Pumping Station Approved make as per satisfaction of Enginee- in-Charge complete in all respect.
Supply Installation Testing and Commissioning of rising spindle flush bottom CI Sluice Gate size(500mmx500mm) generally conform to IS:133-19 material detail 1 Frame, door, guide, extension, wedge, wall thimble, floor standard. CI. to IS 210 Gr. Fg 260 2 Spindle SS: 304 3 Seating faces SS :304/SSCF8 4 Wedge Block DI with SS AISI: 304/CF8 Lining 5 Lift Nut High ternide brass(HT2) 6Fastner (Thimble/Adjustable wedge) Stainless steel 7. Other fastners Carbon steel 8 Extension spindle SS: 304 9 Guide bracket CI to IS.210 Gr. Fg.260 10. Coupling SS AISI: 304 for sewer disposal/ Intermediate Pumping Station Approved make as per satisfaction of Engineer- in-Charge complete in all respect.
Supply installation testing and commissioning of energy efficient 200W Lamps including fittings on High Mast complete in all respects (6 for High mast and 4 on building)flood light (200Wattage, 5700k CCT) , Product dimension in mm (350x285x85) for sewer disposal/ Intermediate Pumping Station Approved make as per satisfaction of Engineer- in-Charge complete in all respect.
Supply of Safety Equipment`s like gloves 2 pair, Fire extinguisher (min. 5), rubber mat (05meter) etc.
Supply installation testing and commissioning of Non Clog HORIZONTAL PUMPS of 725cum/hr@20m of 100HP for sewer disposal/ Intermediate Pumping Station Approved make as per satisfaction of Enginee- in-Charge complete in all respect.
Supply installation testing and commissioning of Non Clog HORIZONTAL PUMPS of 200cum/hr@18m of 30HP for sewer disposal/ Intermediate Pumping Station Approved make as per satisfaction of Enginee- in-Charge complete in all respect.
Supply installation testing and commissioning of Non Clog HORIZONTAL PUMPS of 100cum/hr@15m of 20HP for sewer disposal/ Intermediate Pumping Station Approved make as per satisfaction of Engineer- in-Charge complete in all respect.
Supply installation testing and commissioning of Non Clog Submersible PUMPS of 530cum/hr@20m of 75HP. for sewer disposal/ Intermediate Pumping Station Approved make as per satisfaction of Engineer- in-Charge complete in all respect.
Nicking cement concrete surface (over 28 days old including preparation and laying slurry) in sewer sumpwell including loading ,unloading and carriage of material lead within 5 KM
Bidder Name
Amount
M/s Shree Jee Enterprises(GSTN-NA)--1038585
Anil Dahiya Contractor(GSTN-NA)--1035870
M/s Shree Jee Enterprises
M/s Shree Jee Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .