Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.2 CrAccepted-Finance | ₹2.2 Cr | L1 | Accepted-Finance L1 |
| 2 | L2₹2.3 Cr+₹8.7 L (3.98%)Accepted-Finance | ₹2.3 Cr+₹8.7 L (3.98%) | L2 | Accepted-Finance L2 |
Tender Value
₹2.7 Cr
EMD Value
₹3.4 L
Closing Date
9 Sept 2021, 1:00 pmClosed
Chief Executive Officer
Sadar Bazar, Delhi Cantt.
Construction of CNG Crematorium at Village Old Nangal, Delhi Cantt
2021_DGDE_468952_1
DCB/8/C-13/2021-22
Open Tender
Civil Works
Item Rate
365 days
Delhi Cantt.
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,000
Chief Executive Officer, Delhi Cantonment Board
₹3.4 L
30 Sept 2021
18 Aug 2021
10 Sept 2021
18 Aug 2021
9 Sept 2021
18 Aug 2021
18 Aug 2021 - 9 Sept 2021
Amount
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed.
All kinds of soil.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil.
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, inlayers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m in all kinds of soil
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Filling from available excavated earth, excluding rock/boulder in trenches, plinth, sides of foundation etc. in layers not exceeding 20cm in depth and consolidating each deposited layer by ramming and watering, lead upto 50m and lift upto 1.5m.
Supplying and filling in plinth with Jamuna sand under floors including, watering, ramming consolidating and dressing complete.
Supplying chemical emulsion in sealed containers including delivery as specified.
Chlorpyriphos/Lindane emulsiflable concentrate of 20%
Diluting & injecting chemical emulsion for anti-termite treatment (excluding the cost of chemical emulsion)
Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres/ Sqmt of the verticle surface of the substructure along wall & backfilling etc complete with chlorphriphos/ lindane E.C. 20% with 1% concentration
Along the external wall below concrete or masonary apron using chlorphriphos/ lindane E.C. 20% with 1% concentrators @ 2.25 litres per linear meter including drilling and plugging holes etc. (excluding of chemical emulsion)
Soil under floors foundation, plinth protection and like using chemical emulsion with chlorphyriphos/ lindane E.C. 20% with 1% concentration @ 5 ltrs/ Sqmt for creating continous chemical barrier under and around the columns, pits, walls, trenches, plinth protection etc (excluding cost of chemical emulsion) complete
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, drains, channels etc. upto floor five level, excluding the cost of centring, shuttering and finishing:
1:2:4 (1 Cement : 2 coarse sand : 4 graded stone nominal size) aggregate 20 mm
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size).
Applying a coat of residual petroleum bitumen of penetration 80/100 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil
Making plinth protection 75 mm thick of cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately).
All works upto plinth level
All works above plinth level upto floor V level
Centring and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, bases of columns etc. for mass concrete.
Suspended floors, roofs, landings, balconies, stairs and access platform.
Shelves (Cast in situ)
Lintels, beams, plinth beams, grinders, bressumers and cantilevers.
Columns, Pillars, Piers, Abutments, Posts and Struts
Edges of slabs and breaks in floors and walls.
Walls (any thickness) including attached pilaster, butteresses, plinth and string courses etc.
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured) [Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)]
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Up to plinth level.
Thermo-Mechanically Treated bars.
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Above plinth level.
Thermo-Mechanically Treated bars.
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth manholes, Parapet walls, retaining wall & like
Cement mortar 1:4 (1 cement: 4 coarse sand)
Half brick masonry with bricks of class designation 75 in superstructure above plinth level upto floor V level
Cement mortar 1:4 (1 cement: 4 coarse sand)
Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry (with F.P.S. bricks)
Providing and laying autoclaved aerated cement blocks masonry in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ) The rate includes providing and placing in position 2 Nos. 8 mm dia M.S. bars at every third course of masonry work.
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 lever and a pair of lever hanles of approved quality with necessary screws etc complete.:
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:
Providing and fixing bright finished brass hanging type floor door stopper with ncessary screws etc complete.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or dash fasteners shall be paid separately)
Second class teak wood
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and fixing MS tube/ pipe hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing and fixing aluminium work for doors, windows, ventilators and partitions [using powder coated aluminium (minimum thickness of powder coating 50 micron)] with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
for fixed portions
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required including all fittings like handles, tower bolts, casement stays etc. complete.
Providing & fixing glass panes and securing them in aluminium doors, windows, ventilators shutters etc complete
5.5 mm thick float glass panes
Colour tinted float glass 6 mm thick (with reflective soft coating on face, Visible Light Transmittence VLT of 25 to 35%, weight not less then 20 Kg/Sqmt)
Providing & fixing 12 mm thick prelaminated partcle board with decorative lamination on both sides, flat pressed three layer of graded (medium density) wood particle board confirming to IS 12823 grade 1, Type II, in panelling fixed in aluminium doors, windows, shutters and partition frame with CP brass/ stainless steel screws etc with fitting and fixtures fixed in position complete in all respect as directed by Engineer-in-charge.
Providing & Fixing double action hydraulic floor spin of approved brands and manufacturer confirming to IS 6315, having brand logo embossed on the body/ plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same, matching to existing floors finishing and cover plates with brass pivot and single piece MS Sheet outer box with slide plate etc complete as per direction of the Engineer-in-Charge, with stainless steel cover plate minimum 1.25 mm thick.
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5(1 cement : 5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :
With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand)
25 mm thick
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Extra for fixing granite stone in facia and drops of width upto 150 mm with expoxy risen based adesive including cleaning etc complete
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design:
In 75x75mm deep chase
Making khurras 45 x 45cm with average minimum thickness of 5cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20mm nominal size) over PVC sheet 1m x 1m x 400 micron, finished with 12mm cement plaster 1:3 (1 cement: 3 coarse sand) and coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing and fixing on wall face unplasticised - Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single socketed pipes
110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised - Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.
Coupler 110 mm
Door, bend 110 mm
Bend 87.5 110 mm
Providing and fixing M.S. holder bat clamps of approved design for rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. for 110 mm dia rainwater pipe :
Providing half round edge moulding to marble/ granite/ kota stone/ katni/ udaipur green stone provided in any position and thickness upto 25 mm
Providing and fixing machine cut, mirror/ eggshell polished , stone work for wall lining (veneer work) including dado, skirting, risers of steps etc., in required design and pattern wherever required, stones of different finished surface texture, on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with white cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charge.
20mm thick Kota (area of each slab not exceeding 0.10 Sqmt)
20 mm thick Kota (area of each slab exceeding 0.15 Sqmt, for risers and treads), single stone slabs shall be used for risers and treads without joints.
Providing and fixing machine cut, mirror/ eggshell polished , stone work for wall lining (veneer work) including dado, skirting, risers of steps etc., in required design and pattern wherever required, stones of different finished surface texture, on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with white cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charge.
20mm thick granite stone
Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of any size and diameter, double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head with polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge.
Cement Plaster 15 mm thick of mix, on any surface of bricks, AAC blocks, concerete surfaces etc.
1 : 1 : 3 (1 Cement : 1 Coarse Sand : 3 Fine Sand)
1 : 2 : 4 (1 Cement : 2 Coase Sand : 4 Fine Sand)
1 : 4 (1 Cement : 4 Coarse Sand)
1 : 4 (1 Cement : 4 Coarse Sand), finished with a floating coat of neat cement
10 mm thick cement plaster on ceiling and like
1 : 1 : 2 (1 Cement : 1 Coarse Sand : 2 Fine Sand)
Providing & finishing 10 mm thick P.O.P. on wall/ plastered surfaces using first quality lime finished smooth, including finishing/ preparing surfaces complete
Plastered wall surfaces
Plastered ceiling surfaces
Interior finishing, distempering with 1st quality acrylic distemper (readymix) of approved manufactuerer, of required shade and colour complete as per manufacturer specifications, including priming coat and preparation of surface as per manufacturer specifications on ceiling & wall surfaces
two or more coats on new P.O.P. wall surfaces
two or more coats on new P.O.P. ceiling surfaces
Exterior finishing, finishing walls with acrylic smooth exterior paint of required shade
New work (two or more coats applied @ 1.67 ltrs/ 10 sqmt over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqmt and preparation of surfaces)
Painting steel work with deluxe multi-surface paint to give an even shade. Two or more coat applied @ 0.90 litrs/ 10 sqmt over an undercoat of primer applied @ 0.80 litr/ 10 sqmt of approved brand and manufacturer
Painting wood work with deluxe multi-surface paint of required shade. Two or more coat applied @ 0.90 litrs/ 10 sqmt over an undercoat of primer applied @ 0.75 litr/ 10 sqmt of approved brand and manufacturer
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge for external work.
20 mm nominal outer dia Pipes
25 mm nominal outer dia Pipes
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
25 mm nominal bore
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :
15 mm nominal bore
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.
15 mm nominal bore
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
20 mm nominal bore lever handled operated
25 mm nominal bore lever handled operated
Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge.
Providing and laying cement concrete 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) all-round RCC pipes including bed concrete as per standard design :
250 mm diameter NP-2 Class RCC pipe
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
100 x 100 mm size P type, with sewer bricks confirming to IS 4885
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
250 mm dia. R.C.C. pipe
Supplying of SFRC Manhole covers & frames conforming to IS – 12592 (Part I) using M-35 concrete having clear opening of 560 mm dia as per details below:
Heavy Duty: . Over all Total Size in height mm mm Frame Details 875 155 Cover Details 720 80 APPROVED MAKES : Nimco precast Pvt. Ltd., K.K, TeraFerma, Koncrete Koncepts Ltd., NTC, NITCO UP Concrete products. Contractor to submit procurement vouchers along with the bill. Note :- (i) contractor to submit tax paid vouchers of Precast Polymer obtained from approved manufactures for claim of entire quantity of work incorporated. (ii) Contractor to submit manufacturer certificate of M-35 strength for designated site of work.
Medium Duty: . Over all Total Size in height mm mm Frame Detials 770 110 Cover Details 670 60 APPROVED MAKES : Pragati, Nimco precast Pvt. Ltd., K.K, Tera Ferma, Koncrete Koncepts Ltd., NTC, NITCO UP Concrete products. Contractor to submit procurement vouchers along with the bill. Note :- (i) contractor to submit tax paid vouchers of Precast Polymer obtained from approved manufactures for claim of entire quantity of work incorporated. (ii) Contractor to submit manufacturer certificate of M-35 strength for designated site of work.
Supplying & Fixing SFRC gratings confirming to IS 12592 (Part I) 70 mm thick square or rectangular in shape as directed by Engineer-in-charge using M-35 concrete. APPROVED MAKES: Pragati, Nimco precast Pvt. Ltd., K.K, TeraFerma, Koncrete Koncepts Ltd., NTC, NITCO UP Concrete products. Contractor to submit procurement vouchers along with the bill. Note :- (i) contractor to submit tax paid vouchers of Precast Polymer obtained from approved manufactures for claim of entire quantity of work incorporated. (ii) Contractor to submit manufacturer certificate of M-35 strength for designated site of work.
Providing & fixing to horizontal & vertical surfaces 24 gadge chicken mesh wire between junctions of columns/ beams, walls and conduit pipes wherever required, chicken wire mesh should be fixed with U nails 150 mm centre to centre before plastering the junction. The plastering of walls and beams/ columns in one vertical plane should be carried out in one go, all inclusive complete
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors
100 mm inlet and 100 mm outlet, Sand cast iron S&S as per IS: 3989
Providing and fixing SINTEX or equivalent approved SMC pannel tank of size 2m x 2m x 2m (capacity 8KL) with fittings for inlet, outlet,Over flow,drain, vents, float valve connections of required size and dia. Including provision for manhole with cover and connection from top for level controller and hoisting/fixing the same tank on roof and/or other places at all heights with all bye-works complete as per manufacturer's specification and direction of the Engineer-in- Charge. (Support of tank on brick/RCC/PCC will bepaid under relevent items)
Providing and fixing SINTEX or equivalent approved SMC pannel tank of size 3m x 3m x 3m (capacity 27 KL) with fittings for inlet, outlet,Over flow,drain, vents, float valve connections of required size and dia. Including provision for manhole with cover and connection from top for level controller and hoisting/fixing the same tank on roof and/or other places at all heights with all bye-works complete as per manufacturer's specification and direction of the Engineer-in- Charge. (Support of tank on brick/RCC/PCC will bepaid under relevent items)
Removal of demolished / excavated material to any approved dumping site out side Cantonment limit, under contractor's own arrangements as per direction of Engineer-in-Charge.
Demolition of cement concrete of any description manually or by mechanical means including disposal of material within 50 mtrs lead as per directions of the Engineer-in-charge, nominal concrete 1 : 3 : 6 or richer mix including equivallent design mix
Dismentling precast concrete or stone slabs or paver blocks of any description
Providing & laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all works upto plinth level
1:4:8 (1 Cement : 4 Coarse Sand : 8 graded stone aggregates 20 mm nominal size)
1:2:4 (1 Cement : 2 Coarse Sand : 4 graded stone aggregates 20 mm nominal size)
Providing & laying in position Ready Mix Cement concrete M-10, grade, machine batched, machine mixed, Design Mix Concrete (excluding the cost of centering and shuttering,) placing in position, mechanical vibrated and finished including addition of admixtures in recommended portions (as per IS-9103) to accelerate/retard setting of concrete to improve workability without tampering strength and durability laid to required slope and camber in panels as directed in accordance with IS 456-2000,transported to the site of work from approved RMC plant .
Providing & laying in position Ready Mix Cement concrete M-25, grade, machine batched, machine mixed, Design Mix Concrete (excluding the cost of centering and shuttering,) placing in position, mechanical vibrated and finished including addition of admixtures in recommended portions (as per IS-9103) to accelerate/retard setting of concrete to improve workability without tampering strength and durability laid to required slope and camber in panels as directed in accordance with IS 456-2000,transported to the site of work from approved RMC plant .
Providing and placing, machine cutting grooves, 10 mm wide and 60 mm deep in concrete surfaces for construction/ contraction joints and longitudinal joints, providing joint sealant compound of cold polysulphide in the groove after widening the groove to required width, cleaning the groove with air compressor, insertion of debonding strip, as per MORTH specifications Clause 602
Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment).
Providing and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with (machine cut edges) of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately). Dholpur Stone sand stone - 30mm thick gang saw cut stone.
Providing and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with (machine cut edges) of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately). Agra Stone sand stone - 30mm thick gang saw cut stone.
Providing and fixing structural steel frame (for dry cladding with 30 mm thick gang saw cut with machine cut edges sand stone) on walls at all heights using M.S. square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, welding etc. The frame work shall be fixed to the wall with the help of M.S. brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame and embedded in brick wall with cement concrete block 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) of size 300x230x300 mm, including cost of necessary centring and shuttering and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. Approved cramps/ pins etc. shall be welded to the frame work to support stone cladding, the steel work will be given a priming coat of Zinc primer as approved by Engineerin- charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Engineer-in-charge for approval before execution). The frame work shall be fixed in true horizontal & vertical lines/planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel cramps shall be paid for separately and nothing extra shall be paid).
Providing and fixing adjustable stainless steel cramps of approved quality, required shape and size, adjustable with stainless steel nuts, bolts and washer (total weight not less than 260 gms), for dry stone cladding fixed on frame work at suitable location, including making necessary recesses in stone slab, drilling required holes etc complete as per direction of the Engineer-in-charge
Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases.
Providing and fixing moudlings/cornices made out of single sand stone blocks (Dholpur or Agra) with aesthetic carvings as per architctural design fixed to walls at indicated location complete with stainless steel cramps, SS pins etc for proper rigidity fixed in position complete upto 12.50 mt height all as directed by Engineer-in- charge.
75mm depth
100mm depth
150mm depth
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete
2nd class teak wood. 50x12 mm
Providing and fixing decorative high pressure laminated sheet of plain/wood grain in gloss/matt/suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS: 2046 Type S including cost of adhesive of approved quality.
1mm thick
Providing and fixing aluminum die cast body tubular type universal hydraulic door closer (having brand logo with IS: 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete :
Supplying and fixing Joist, Channel, Angle, Girder or Tee sections,fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20 mm of the length indicated using Fe-410W(Gde-E-250) quality– ‘A’
Supplying and fixing framed work as in doors or gates of angle or other section with gusset plate rails, braces etc, complete, drilled for fixing of steel sheeting or other covering. Doors, etc, to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing complete using 410W (Gde-E-250) quality ‘A’
Supplying and fixing Mild steel, plain, black sheet 1.6 mm thick in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc, as required.
Supplying and fixing rolling shutters of approved make, made of required size M.S lath , interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shalf with brackets , side guides and arrangments for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS 4454-part 1 and M.S.top cover of required thickness for rolling shutters, 80x1.25mm M.S. laths with 1.25 mm thick top cover including providing and fixing ball bearing 02 nos. each side for rolling shutters
M&L filling broken brick graded aggregates of gauge 40 to 80 mm in soakage pit ,sockage pit/well as directed by Engineer incharge.
Supplying and mixing of liquid Water proofing compound for cement concrete, cement plaster conforming to IS specifications.
Supplying and stacking of Good Earth on locations as directed by Engineer-in-Charge for land scaping for horticulture/ arboriculture work or earth filling . The earth shall be brought from out side Cantonment Limits (earth supplied in stacks shall be reduced by 20% for payments on accounts of voids, including filling of good earth to levels , gradients, complete all as sepcified /directed by the Engineer-in- Charge.
Providing and fixing Precast Polymer Saucer drain of size and shape as indicated by Engineer-in-charge for surface drainage, fixed, laid over 20mm thick cement mortar 1 : 3 (1 cement : 3 coarse sand) and pointing with 1 : 2 cement mortar (1 cement : 2 find sand) laid to slopes complete as directed by Engineer-in-charge. Size of drain 900 mm length , width 300 mm and thickness 100 mm , design mix M-30 made using Vibro technology complete.
Transportation at site of work DTH Rig plant, equipment etc required for drilling in any earthen strata, and development and removal of the same from site on completion of job all as specified and directed by Engineer-in-Charge.
Drilling of 200mm (8”) dia bore hole by, DTH machine upto 100 mt depth below the ground level including disposal of surplus soil to distance not exceeding 125 mtr. at the site as specified and directed by Engineer-in-Charge.
Supplying and lowering and fixing of plain MS slotted black pipe 6”(150 mm ) nominal bore having(1.59 mm to 3 mm ) x 75 mm slot complete medium grade wall thickness 4.80 mm made of MS ERW sockets and socketed as per IS 1239 marked pipe in standard length complete with necessary fitting and jointing complete all as specified and directed by Engineer-in-Charge.
Supply & packing pea gravel of size 2.5mm around casing pipe all as specified and directed by Engineer-in Charge.
Supplying and filling of aggregate for loose filling of gauge exc. 63 mm and n. exc. 100 mm of broken stone/boulders.
Supplying and filling of coarse sand in recharge pit.
Point wiring in PVC conduit, with modular type switch :- Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. GROUP B
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit,and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. GROUP B
Power plug wiring in PVC conduit (2 x 4 Sq.Mm.) :- Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Circuit / Sub main wiring in PVC conduit :- Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire.
2 X 4 sq. mm + 1 X 4 sq. mm earth wire.
2 X 6 sq. mm + 1 X 6 sq. mm earth wire.
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
S/F light plug point modular type accessories :- Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
S/F power plug point modular type accessories :- Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
S/F modular type blanking plate :- Supply and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C' series, miniature circuit breaker (MCB)suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
single pole
Double pole
Supplying & fixing single pole, blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, four pole, (three phase & neutral) 415 volts, residual current circuit breaker (RCCB), having a sensivity current upto 300 miliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required :
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
6 way , Double door
8 way , Double door
Supplying and fixing following way, horizontal type TP&N, sheet steel MCB distribution board, 415 V on surface /recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolators).
4 way (4 + 12), Double door
6 way (4 + 18), Double door
8 way (4 + 24), Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar,din bar for mounting MCBs (but without MCBs and incomer ) as required (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
8 way (4 + 24), Double door
Supplying, fixing, connecting, testing and commissioning of following rating, ISI marked (IS 8828) 240 / 415 volts, 10 KA, Miniature Circuit Breaker (MCB) of single / double / three / four poles in the existing MCB DB or in existing MS enclosure complete in all respects.
63 Amp. FP MCB
Supply of Mounting rail with Master LED tube with all accessories as per standard item:
TMC 501 P 2xT-LED 22W P3241 with Master LED Tube 2x 18 W, 3200 lumen
Supply of recess / surface, round / square, ceiling mounting LED Light fixture having Powder coated die cast aluminium housing with heat sink, glare free diffuser with uniform light distribution, PF above 0.9, efficacy above 90 lm/watt, pre wired with constant current LED driver set, suitable for 1 phase, 240 V, 50 Hz, IP 20 complete in all respects. (colour temerature 3000oK / 4000oK / 6500oK - to be confirmed before supply)
12 watt LED
SUPPLY OF CEILING FANS: Supply of AC 230/250 volts, 50 HZ energy efficient ceiling fan with standard down rod, blades, 2 nos. caps etc. complete
1400 mm sweep
Installation, testing and commissioning of pre-wired, flourescent fitting / compact fluorescent fitting of all types, complete with all accessories and tubes etc. directly on ceiling / wall, including connection with 1.5 sq. mm. FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Supply, testing and Commissioning of Silent type Diesel Generating Set at 0.8 PF, 415 Volts, 50 cycles per second, 1500 rpm, 3 phase, suitable for parallel operation, 0.85 load factor including circuit breaker for isolation, sound proof acoustic and weather proof enclosure, residential type silencer (as per CPCB norms) fabricated out of CRCA sheet of 14 / 16 SWG thickness with min. 9 tank pretreated before powder coating with ventillation system complete in all respects comprising of the following. OEM - Jakson / Sudhir / Bhaskar / Sterling / TIL {Engine - Cummins, MTU, Perking , Volvo Penta , Kirlosker } {Alternator - Stamford / Leroy Somer}
Diesel Engine - Diesel Engine suitable for driving alternator of above rating, compression ignition, 4 stroke cycle, Radiator cooled, turbo charged, battery starting, 1500 RPM, suitable for above output of alternator at 40oC, 50% RH & at 1000 M MSL and confirming to BS 5514, BS 649, IS 10000, capable of taking 10% overloading for one hour after 12 hrs of continuous loading, complete with all the accessories i.e. tachometer with hour meter, flexible coupling with guard, crank case of steel, crank shaft, conncting rods, mechanical governing system, dynamically balanced flywheel, air intake manifold, Air cleaner, anti vibration pads, starter motor, including all other accessories required to complete the system. Instrument Panel - Engine mounted Instrument Panel fitted with and having digital display for followings : Start stop switch with key Water temperature indication Lubrication oil pressure indication. Lubrication oil temperature indication. Battery charging indication RPM indication Over speed indication Low Lube oil trip indication Engine hours indication
Alternator - Synchronous Alternator of above capacity at 0.8 PF, 3 phase, 415 volts, 50 cycles, 4 wire, 1500 RPM, suitable for operation at 40 deg C, 50% RH & at 1000 meter above MSL, capable of taking 10% overlioading for one hour after 12 hrs of continuous loading, brushless, self excited, self regulated through AVR, continuous duty confirming to IS 4722, BS 2613 suitable for tropical conditions, class H insulation, including terminal box suitable for cable termination as required.
Base Frame - Both the engine and alternator shall be mounted on suitable base frame made of MS channel which shall be installed on cement concrete foundation and vibration isolating arrangement as per recommendations of manufacturer. Inbuilt Fuel tank of standard capacity complete with inlet and outlet connections, oil indication gauge, drain plug, air breather, fuel transfer system for automatic fuel refilling system with pump, piping, valves, level indicators etc. complete. Daily service Fuel tank of 990 liters capacity fabricated out of 3 mm thick MS sheet complete with inlet and outlet connections, oil indication gauge, drain plug, air breather, fuel transfer system for automatic fuel refilling system with pump, C class MS fuel piping of suitable dia between fuel tank and diesel engine, valves, level indicators and all standard accessories etc. as required. Exhaust System - Exhaust manifold with silencer complete with rock wool insulation of minimum 75 mm thick of 150 Kg per cu M density on all sides, with chicken mesh wrapping and 26 SWG aluminium sheet cladding complete as required. Starting system - 24 Volt DC starting system comprising of starter motors : voltage regulator and arrangement for initial excitation complete with 12/24 Volts suitable nos. lead acid type batteries of suitable AH. Ventillation System - Arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air into the atmosphere as per standard specifications.
Supply, Fixing, testing and Commissioning of Exhaust gas piping system of Class `B' MS pipe as per IS:1239 for upto 125 mm dia and for 150 mm dia & above MS pipe as per IS:3589 with welded joints, cut to required lengths with necessary bends, fittings, expansion, flexible joints of suitable diameter including providing hot dip galvanized supporting / clamping arrangements on beam / wall with all accessories at suitable intervals, anti vibration mounting, with mineral wool / rock wool insulation of 75 mm thick of 150 Kg per cu M density on all sides of exhaust pipe, with chicken mesh wrapping and 26 SWG aluminium sheet cladding complete as required. The aluminum foil should be tightly cladded to insulation surface of pipe. The aluminum cladding shall be locked with sheet metal screws with other sections of aluminium foil. The exhaust piping shall be fixed with the help of hot dipped galvanized M.S angle iron of size not less than 50 mm x 6 mm duly grouted in the wall and with suitable GI angle/channel iron structure, design duly approved by the Consultant / Architect. The measurement shall be done longitudnally with any extra allownce for bends beyond centre line of bend. (Stack height should be in accordance with emission regulations of CPCB, which will go well above the top most terrace) The exhaust piping system should be suitable for upto 450oC temperature, the surface temperature of exhaust pipe shall not exceed more than 60oC.
100 mm dia (wall thickness - 4.85 mm)
InstalIation of Silent Type D G Set - The instalation of D G Set will include receiving, unloading, loading at designated place, installation, testing and commissioning, affecting proper connections with the power and control cables, coordination with the D G Set supplier, civil contractors and inlcuding the arrangement of required amount of fuel oil, lubricating oil, artificial load for testing of first run etc complete in all respects. The small items / accessories required for erection of D G Set will be included in the rates. (The civil work for the D G Set foundation will be seperate)
INCOMER : 40 AMP FP MCB (10 KA) BUS BAR : 200 AMP, 500 Volts, 3 phase 50 HZ TPN high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 1.00 sq mm / amp. The Maximum allowable temperature for the Bus bar to be restricted to 85 deg C. The temperature rise should be restricted to 35 deg C above ambient temperature. OUT GOINGS : 2 nos. 40 AMP DP MCB (10 KA) 6 nos. 16 AMP DP MCB (10 KA)
Vertical DB / Panel for Chambers Design, manufacture, supply, instalation, testing and commissioning of Vertical DB / Panel fabricated out of 16 SWG CRCA sheet steel, IP52, wall / floor mounting type. The sheet steel shall undergo minimum 9 tank treatment followed by finishing powder coating of min 60 micron thickness. the board includes 415 V electrolytic Aluminium Bus Bar, removable gland plates, cable glands, including connection with outgoing feeders complete in all respect. The incoming MCCB shall be thermal-magnetic based with inbuilt O/L & S/C release with E/F protection and all Outgoings MCCB's shall be thermal-magnetic based with inbuilt O/L & S/C release. All MCCB's shall be Ics = 100% Icu, Thermo-magnetic type with rotary handle & pad locking arrangement, with adjustable O/L & S/C trip setting as per load requirement. All TP MCCB shall be with solid isolable neutral link. The breaking capacity specified is Ics value. All outgoing MCB's shall be C type with 10 KA breaking capacity. INCOMER : 80 AMP FP MCCB (25 KA) BUS BAR : 200 AMP, 500 Volts, 3 phase 50 HZ TPN high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 1.00 sq mm / amp. The Maximum allowable temperature for the Bus bar to be restricted to 85 deg C. The temperature rise should be restricted to 35 deg C above ambient temperature.
Supply of ISI marked aluminium conductor XLPE insulated cable as per IS 7098, armoured, served, sheathed 1100 volts grade.
10 sqmm 4 core
16 sqmm 4 core
25 sqmm 3 1/2 core
120 sqmm 3 1/2 core
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
10 sqmm 4 core
16 sqmm 4 core
25 sqmm 3 1/2 core
120 sqmm 3 1/2 core
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Supply of street light Luminaire / post top lantern for external lighting complete with builtin integral heavy duty electronic, constant current LED driver, control gears, fabricated out of heavy gauge aluminium sheet, G I pole with base plate, foundation bolts, arm, builtin cable junction box with MCB & service door, prewired, terminal connector for loop in loop out suitable for three phase cable, finished with PU based paint over zinc phosphate primer, etc. IP 65 protection, complete system as required as per the standard catalogue item.
6 meter high 35 to 45 watt LED street light Luminaire / post top lantern
Supply of 6 to 12 watt LED type Bollard garden light for landscape lighting complete with builtin integral heavy duty electronic, constant current LED driver, integral control gear, base plate, foundation bolts, terminal connector for loop in loop out suitable for single phase cable, finished with PU based paint etc. IP 65 protection, complete system as required as per the standard catalogue item.
Supply of Octagonal Poles of 6 M height with 130 mm bottom A/F & 70 mm top A/F (across face) made up of 3mm thick HT sheet along with galvanized base plate of size 220x220x12mm suitable to withstand max wind speed of 169 KM/hr and including mounting of head frame suitable for single / twin 250 or 400 watt flood light luminaires. The internal and external surface of poles shall be hot dip galvanized to 70 micron DFT. The pole will have a weather proof camouflaged junction box at 500 mm ht. with flush cover for cable termination block & earth stud with washer & nuts etc i/c provision for supporting cable of size up to 2 Nos. of 4c x 25 sqmm i/c Supply of 4 nos. M20 X 600 mm long 'J' type EN 8 grade foundation bolts with nuts and washers, 63 Amp terminal block suitable for up to 4 c x 25 Sq.mm Aluminium conductor cable. The Pole should be complete with all required accessories to complete the work as directed by Engg-in-charge.
Installation, testing and commissioning of 6 meter high street light pole / post top lantern with LED / MH / CDMT type luminaires complete system with arm, control gears etc. including connection with 3x2.5 sqmm flexible fire retardant copper connecting wire of required length from cable junction box to luminaire complete including excavation and required Masonry work in cement concrete (1:2:4) for erection of pole as required.
Installation, testing and commissioning of CFL / LED type bollard garden light fixures with required lamps, control gears, including connection with 3x1.5 sqmm flexible fire retardant copper connecting wire of required length complete as required.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.
63 mm dia (OD-63 mm & ID-51 mm nominal)
200 mm dia (OD-200 mm & ID-175 mm nominal)
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. (d) Suitable cement concrete foundation duly plastered and with anti vibration pads.
900 lpm at 35 m Head
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :
Single headed Stainless steel
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :
Stainless Steel (Grade 304)
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :
Stainless Steel (Grade 304)
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. Each 1291.00
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
100 mm dia.
150 mm dia.
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
100mm dia.
150mm dia.
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :
100 mm dia.
150 mm dia.
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
25 mm nominal bore
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.
150 mm dia.
Providing and fixing following size Pressure gauge (0-15 Kg/Cm2) complete with shut off valve duly calibrated before installation complete as required & as per enclosed specification. 150mm dia.
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required
4 way - 150 mm dia M.S. Pipe
Providing and fixing heavy duty copper armored cables 1.1 KVA grade including necessary support clamps at ceiling level and connection legs complete in all respects.
Control cable 4 core 35 Sq.mm
Supply, installation, testing and commissioning ISI marked (IS:15683) Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kg. Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 and walll suspension braket as required as per specifications.
Supply, installation, testing and commissioning of 6kg ABC (Powder Type) Fire Extinguisher. Mild Steel Cylinders ISI marked fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged with ABC 90 powder (Mono Ammonium Phosphate) pressured by Nitrogen complete in all respects including wall suspension bracket and conforming to IS:15683 as required as per specifications.
Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. 23.1 100mm dia Each 7362.00
100mm dia
Providing & fixing standard carbon steel fireman axe with rubber insulated handle tested to 20000 Volts.
Supply, installation, testing and commissioning of Fresh Air injection system - Supply of fresh air forced draught fan having outforced capacity upto 300 water column, for supplying the fresh air to primary chamber for combustion of corpse and for supplying fresh air to dillution chamber/quenching chamber for reducing the outlet heat before before entering the chimeney through wet scrubber, with required dampers and gate valves etc. The motor installed should be 2 BHP 3 Phase. (Make: Kirlosker/ABB/Havells)
Supply & fixing of Inconel Thermocouple - Heat sensing range 0 to 1200 degree Celsius having (Cr - Al) sensor housed in SS 304 casing of dimension 600 mm long × 8 mm Outer Dia complete encased and to be fitted with terminal on other end for connection of fire retardant. Compensating wire of 2 cores 0.5 sq. mm. for heat sensing from thermocouple to Temperature controller covered with asbestos embedded rope about 50 m length as per direction of EIC.
Supply & laying of armoured cable from furmace control panel to different motors in Trench /Tray/Wall surface. 1.1 KV grade 4 core 2.5 sq mm Fire Retardant PVC (Copper) including S&F M.S. saddles with earthing attachment in 1 x no. 10 SWG G.I. wire making holes etc, as necessary (Polycab/Havells/KE/Gloster) including double compression flame proof glanding and termination.
Design, fabrication, supply and Installation and testing commissioning of complete MS structural work for furnace with structural pipes and sheets of minimum 5 mm thick for supporting the internal refractory linings / Bricks and to bear heat stresses of temprature upto 1600 degree centigradeas below: (a)MS Steel Cremation Machine Size - Hx1950mm. Wx1650mm. Lx2750mm. (b)Outside furnace skin Temp.- 3 ºC above ambient temperature (c) Door Operating Motor - 2 HP, 900-1440 RPM, 415 V, 3 PH.sq. cage. CONSTRUCTION OF INCINERATION CHAMBER : Design of the Furnace is a double/ stage combustion chamber. Primary chamber is to be used for corpse burning and secondary chamber is to be used for burning the odour and black heavy smoke or can be used as quenching chamber or tunnel, before discharging it into atmosphere via wet scrubber. The modulating burner installed in these chambers should work through ringelmann gas analyser and take command from it through PLC control panel for increasing or decreasing the flame. The outer structure of the combustion chamber is made of Prime Quality Mild Steel Plates/ structural pipes, of minimum 5mm, thickness as per IS specification suitable to withstand temperature of 1300ºC. The structure is sturdy to withstand any stresses or strains formed during operation. the external casing is reinforced with structural pipes ,angles & channels with minimum 2mm thickness and should be powder coated with any colour as approved by Engineer-in-Charge.
PRIMARY CHAMBER: Body is loaded into this chamber through a charging Door and loading trolley. This chamber is fitted with burners which are automatically operated and maintain the temperature in the chamber to the desired level of 800±50ºC or as desired. The temperature inside the chamber is controlled using a PLC control sensors and solid state digital temperature indicating controller. Once the desired temperature is achieved the burners will automatically trip off and vice versa the same shall automatically start to maintain the desired temperature. Altogether the indicators ensure complete combustion. This controlled temperature eliminates all possibilities of odour. (a) This PNG/LPG based human body cremation machine incorporates full automatic control including that of flue gas emissions. It should meets and exceeds the Indian and most stringent international pollution, environmental, health and air emission regulations controlled through Ringelmann chart of smoke detection through machine and to be work on online method, ie There should be a fully automatic control mechanism that normally results in flue gases without black smoke and odour. Any potential increase in black smoke must be automatically detected and the air increased so that waste gases are completely combusted at a sufficiently high temperature to eliminate odors. (b) The exhaust chimney should be preferably mounted off centre and should satisfy all local regulations pertaining to environmental norms. (c)The cremation machine operates on natural gas, LPG gas ,and employs the proven chamber design for clean discharge and reliable operation. There should be concentration on providing a simplified control interface requiring no special operator skills
MS with Furnace Charge Door motorized and manually operated with gear box or C.I. made counter weight. Dimesnsions of gate - 1150 mm Width X1050mm. Height X 150 mm thickness ( made from MS 8mm thick plate & B Class C channel ) MOTORISED BODY CHARGING DOOR : The CHARGNG DOOR should be motorized for automatically opening and closing the primary chamber by mere pressing the push buttons provided on the control panel. This enables the door to move to and fro (sliding on main structure), which eases the operation. The motor rating shall be 2 HP, 900-1440 rpm., 415 V, 3 Ph and the same shall be provided along with door operating mechanism, safety guards, Limit switches etc. In case of Power failure or while not in operation the door can be opened manually. It should be lined with 128 density of ceramic fibre and whytheat K quality castables.
Supply, installation, testing & commissioning of Hydrulic semi-autometic body Charging trolley with handle. Mechanically operated MS Steel chequered plate top 3mm thick and 75x40 mm. channel .
Supply, instaliation, testing and commissioning of complete set of refractory shaped bricks with Refactory work of furnace in both primary and secondary combustion chambers (a), The furnace is lined with 70% percent High Alumina Refractory Bricks, backed up with Cold Face and high quality insulation bricks/Hysil blocks and ceramic fibre blanket of 128 density for making the total wall thickness from outer surface of machine 325mm ,withstanding capacity of High Temperature of 1400ºC The inner most refractory, which is hot face is composed of 70% percent HIGH Alumina and having high thermal stress. Hot face refractory bricks are backed up with cold face refractory insulation/Hysil blocks . The two layers of ceramic wool or ceramic board insulation provided between the cold face refractory and the outer body of the Furnace. Thus the temperature of the outer body of the Furnace doesn't exceed 30ºC above the ambient temperature. Refractory Bricks confirm to IS 2042. (b)Complete lining & assembling of entire cremation chamber according to standard size with proper arrangement of accommodation of burners, resting of dead body with sufficient opening for falling of ashes to the ash chamber and sufficient ventilation for fresh air spraying (c) Complete lining and assembling of entire cremation chamber according to standard size with provision of drawing out ashes from the rear side and sufficient ventilation for fresh air injection (d) Complete lining and assembling of entire cremation chamber according to the standard size with provision of air inlet supplying by fresh air blower and arrangement of multi ventilation path for fresh air injection to the ash chamber and cremation chamber.
FLUE GAS DUCTINGS : The flue gas ducting shall be made from 3 mm thick S.S and M.S. sheet and flanges from 5 mm thick plate confirming to specifications, flanges, bends, gaskets. The ducting shall carry the gases from the Post Combustion Chamber to Venturi System and then Scrubbing System to the I.D. Fan/Blower. The diameter of the duct shall be 400/300 mm.
Design, engineering, fabrication, supply, installation testing and commissioning of Stainless Steel (304) Pollution Control Device - Stainless steel (grade 304) 3mm thick sheet,wet scrubber cyclone dia of 800 mm, with inbuilt facility of SS Jali and water spray on incoming gases, 200mm dia arrangement for inlet and outlet for gas , with 3mm Tank with minimum water capacity of 3200 litres. & A vertical type recirculation tank capacity 3200 litres, manufactured from 3mm thick stainless sheet of 304 grade with adequate drain system for circulating 5% caustic solution through cyclone scrubber shall also be provided. The complete accessories like valves, fittings are provided. Recirculation pump 2 BHP 3 phase, manufactured by branded company is to be provided for re-circulating scrubbing solution. An overhead HDPE tank of 1000 Liters shall also have to be provided by agency which shall be used to make up the water in this the tank.
Design, engineering, Supply, installation, testing and commissioning of induced draft fan impleller made of Mild steel to withstand temperature rise in continuous duty in surrounding ambience. MS sheet covering, with induction motor 3BHP, 3 phase, 415v, 50 hz and other accessories such as belt pulley & The gases coming from the wet Scrubbing System will pass to the chimney stack through the Blower/I.D. Fan . The I.D. fan/Blower shall be designed to suck the hot gases from the wet scrubber and pump them to the chimney stack and shall have the capacity to compensate the pressure drop in the wet scrubbing system. It shall be 'V' belt driven and provided with suitable bearings, dampers, anti-vibration rubber pads, safety guards where ever necessary.
Design, engineering, supply, delivery at site, installation, testing and commissioning of MS self supported chimney of 30 mtr with inspection door and MS Ladder upto Operating platfrom. Chimney should be made with 25 mm thick sheet at bottom plate & 25 mm bottom flange,8mm. then 6mm and then 5mm pipe of MS. Base should be 1200mm, and top is 300 mm. Base plates with ribs and stiffeners. 18 nos. foundation bolts with 32mm dia and 1500 mm length supported with steel rope of 8 mm square, 3 sides from 2nd top flange of chimney including 2 coat of heat resistant paint to avoid corrosion of metal.
Design, engineering, supply, installation ,testing and commissioning of re-circulation water pump motor alongwith necessary pipeline and accessories. 2 HP, 1440 RPM, 415 V, 3 Phase sq cage.
CNG MANIFOLD Made From CS Seamless Sch 10 , 25 NB Pipe,( Manifold 8 X2 ), Flexible hose Pipe 1M , NRV Brass, Pin Type Cylinder ADOPTER , C.S. Ball Valve flange type With Flanges 25 NB,Regulator By pass system ,REGULATOR Inlet Pressure 17 Bar, Out Let 10 Bar, Flow 100 CUM/Hr Flange End, Providing & Fixing of SS 304 Pressure Gauge with Needle valve, Dial Size 100mm , range 0-16kg./sq. cm, Bottem Connection 1/2', Filter Flange 1" Type Flange End with matching flanges & Nut Bolt, MS Support , Nut bolt, Fastener , Copper Jumper etc,Testing Installation and Commissioning of manifold,
Providing and fixing CS Seamless 40NB Sch 40 pipes, complete with all fittings such as elbow, socket, reducer, G.I. U clamps. Including painting pipes and fitting with two coat of synthetic enamel paint of approved quality as per pipe colour over a coat of red oxide. (Sprial Wonded Gasket & Copper Jumper on All flange Joints) and Providing & Fixing of SS 304 Pressure Gauge with Needle valve, Dial Size 100mm , range 0-4 kg./sq. cm, Bottem Connection 1/2'.
Bidder Name
Amount
AMIT ASSOCIATES(GSTN-07ACUPG0847K1Z7)
M/s. Kansal Construction Co.(GSTN-07AALPK1176E3ZR)
AMIT ASSOCIATES
AMIT ASSOCIATES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .