Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.4 LAccepted-AOC KRISHNA SOCIETY OPP TODI XRAY AND DIAG CENTRE MAKUM ROAD TINSUKIA ASSAM 786125 | TINSUKIA | ASSAM | 786125 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹28.6 L+₹13,835 (0.49%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹30.0 L+₹1.6 L (5.50%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹31.7 L+₹3.3 L (11.6%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹32.9 L+₹4.5 L (15.9%)Rejected-Finance | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
7 Jun 2024, 6:00 pmClosed
GE NAMS
GE NAMS AMRITSAR
REPAIR/MAINT OF PUMP SET, MOTORS AND ALLIED WORKS AT WATER SUPPLY PUMP HOUSE AT NAMS
2024_MES_653386_1
GE NAMS-47/2024-25
Open Tender
Civil Works
Item Rate
270 days
GE NAMS
CLASS D CATEGORY b(i)
8 documents required · 8 mandatory
₹500
GE NAMS
₹70,000
16 Jul 2024
10 May 2024
14 Jun 2024
10 May 2024
7 Jun 2024
24 May 2024
Amount
M & L for taking out / lifting from bore well and shifting submersible pump/motor set to wksp for repairing including dismantling / opening carefully all burnt winding wire by strip opening of 3 phase A.C submersible motor, any make of the following capacity as mentioned below and rewinding the motor with PVC insulated superior quality water proof submersible motor copper winding wire of suitable size including PVC shelves, Varnishing, packing etc and reassembling, testing and lowering the submersible pump set in borewell complete all as specified and directed Note : (a ) The cost of copper winding wire of any size/gauge deemed to included in this job.(b) The Cost of transportation such as vehicle , T & P and man power deemd to include in this job.(c) Old Copper winding wire will be the property of Contractor.
(ii) 40 HP to 45 HP
(iii) 30 HP to 35 HP
(iv) 20 HP to 25 HP
(v) 10 TO 15 HP
(vi) 1 HP to 2 HP
S & F in replacement of thrust plate of the same make as of submersible motor of following capacity:-
(ii) 40 to 45 HP
(iii) 30 to 35 HP
(iv) 20 to 25 HP
(v) 10 to 15 HP
(vi)1 to 2 HP
S & F in replacement of rubber bush suitable for the following capacity submersible electric motor complete all as specified and directed.
(ii) 40 HP to 45 HP
(iii) 30 HP to 35 HP
(iv) 20 HP to 25 HP
(v) 10 HP TO 15 HP
(vi)1 HP to 2 HP
S & F in replacement of stainless steel bush with key suitable for the following capacity submersible motor complete all as specified and directed.
(ii) 40 HP to 45 HP
(iii) 30 HP to 35 HP
(iv) 20 HP to 25 HP
(v) 10 HP TO 15 HP
(vi)1 HP to 2 HP
S & F in replacement of Gun Metal bush suitable for the following capacity submersible motor complete all as specified and directed.
(ii) 40 HP to 45 HP
(iii) 30 HP to 35 HP
(iv) 20 HP to 25 HP
(v) 10 HP TO 15 HP
(vi)1 HP to 2 HP
S & F in replacement of mechanical oil seal suitable for the following capacity of submersible pump motor complete all as specified and directed :-
(ii) 40 HP to 45 HP
(iii) 30 HP to 35 HP
(iv) 20 HP to 25 HP
(v) 10 HP TO 15 HP
(vi)1 HP to 2 HP
M & L for taking out / lifting from bore well dismentaling, opening of any type of submersible pump set 60 HP of any stage/size/make and re-assembling the pump after repair/replacement of the defective parts of pump testing and lowering the pump complete all as specified and directed. Note: The following defective parts replacement will be measured and paid separetly.
(i) Pump shaft of stainless steel of suitable size.
(ii) Impellor bronze/gun metal of suitable size.
(iii) CI neck ring.
(iv) Gun metal bush
(v) Sand cup.
(vi) Shaft coupling of stainless steel.
M & L for taking out / lifting from bore well dismentaling, opening of any type of submersible pump set 40 to 45 HP of any stage/size/make and re-assembling the pump after repair/replacement of the defective parts of pump testing and lowering the pump complete all as specified and directed. Note: The following defective parts replacement will be measured and paid separetly.
(i) Pump shaft of stainless steel of suitable size.
(ii) Impellor bronze/gun metal of suitable size.
(iii) CI neck ring.
(iv) Gun metal bush
(v) Sand cup.
(vi) Shaft coupling of stainless steel.
M & L for taking out / lifting from bore well dismentaling, opening of any type of submersible pump set 30 to 35 HP of any stage/size/make and re-assembling the pump after repair/replacement of the defective parts of pump testing and lowering the pump complete all as specified and directed. Note: The following defective parts replacement will be measured and paid separetly.
(i) Pump shaft of stainless steel of suitable size.
(ii) Impellor bronze/gun metal of suitable size.
(iii) CI neck ring.
(iv) Gun metal bush
(v) Sand cup.
(vi) Shaft coupling of stainless steel.
M & L for taking out / lifting from bore well dismentaling, opening of any type of submersible pump set 20 to 25 HP of any stage/size/make and re-assembling the pump after repair/replacement of the defective parts of pump testing and lowering the pump complete all as specified and directed. Note: The following defective parts replacement will be measured and paid separetly.
(i) Pump shaft of stainless steel of suitable size.
(ii) Impellor bronze/gun metal of suitable size.
(iii) CI neck ring.
(iv) Gun metal bush
(v) Sand cup.
(vi) Shaft coupling of stainless steel.
M & L for taking out / lifting from bore well dismentaling, opening of any type of submersible pump set 10 HP to 15 HP of any stage/size/make and re-assembling the pump after repair/replacement of the defective parts of pump testing and lowering the pump complete all as specified and directed. Note: The following defective parts replacement will be measured and paid separetly.
(i) Pump shaft of stainless steel of suitable size.
(ii) Impellor bronze/gun metal of suitable size.
(iii) CI neck ring.
(iv) Gun metal bush
(v) Sand cup.
(vi) Shaft coupling of stainless steel.
M&L for re-metalling of gun metal/bronze/impeller, turning, facing of required size.10 to 25 HP
M&L for re-metalling of gun metal/bronze/impeller, turning, facing of required size.30 to 60 HP
M & L for taking out / lifting from bore well dismentaling, opening of any type of submersible pump set 1 HP to 2 HP of any stage/size/make and re-assembling the pump after repair/replacement of the defective parts of pump testing and lowering the pump complete all as specified and directed. Note: The following defective parts replacement will be measured and paid separetly.
(i) Pump shaft of stainless steel of suitable size.
(ii) Impellor bronze/gun metal of suitable size.
(iii) CI neck ring.
(iv) Gun metal bush
(v) Sand cup.
(vi) Shaft coupling of stainless steel.
Material and labour in replacement the spares/components of motor protection starter in panel complete all as specified and directed as follows :-
(a) Supply and fixing in replacement 3 Pole power contactor 25 Amp 3 pole all as specified and directed
(b) Supply and fixing in replacement 3 Pole power contactor 45 Amp 3 pole all as specified and directed
(c) Supply and fixing in replacement 3 Pole power contactor 70 Amp 3 pole all as specified and directed
(d) Supply and fixing in replacement 3 Pole power contactor 85 Amp 3 pole all as specified and directed
(e) Single phase preventor SCP 4 type.
(f) Relay range 45 Amp to 65 Amp
(g) Timmer ET 100 to 30 sec 415 volt
(h) Motor protection relay range 9-45 A
(j) Add on auxiliary contact block type MNX 1NO + 1NC
Excavation in trenches not exc 1.5 m wide and not exc 1.5 mtr deep and getting out in any type of soil complete only for rectify leakage in exisiting Ductle Iron pipe/ PPR pipe upto 200 mm dia all as specified and directed.
Returning filling in (soil) including spreading levelling, watering and well ramming in layers not exc 25 cm thick all as specified and directed by Engineer -in-charge.
Removing excavated material (soil) to a distance not exceeding 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed.
Supply & fixing in Replacement including connecting, commissioning and testing of LT panel . Indoor type panel ,weather proof , dust and vermin proof (IP 4X) suitable for 440 V grade 3 phase 50 HZ AC supply floor mounted with front door and Back opening having locking arrangement on both sides prewired with copper conductor PVC insulated flexible wire size not less than 1.5 sq mm / extension strips and connected with suitable size copper thimbles / lugs duly painted with siemens grey epoxy powder coating after suitable chemical treatment , legs duly embedded in ground in PCC 1:2:4 type B-1 [using 20 mm graded crushed stone aggregate] of suitable size including locking arrangement on both sides suitable for mounting , with required sheet metal enclosures, thimbles , based application complete all as specified and directed by Engr-in-Charge and comprising of the following accessories :-
(a) Incommer MCCB 250 Amp , Four Pole, Thermal based release with adjustable O/L ,Adj S/C Setting Class II Front Face, 36KA rupturing capacity, Ics=100%Icu, Isolation with Positive Break Indication , Standard Extended Rotary Handle, Spreaders, Phase Barrier- 1 No (b) Metering Section- Digital Voltmeter showing 0-500V with duly prewired with copper cable of suitalbe size with 3x2A SP MCB, 3 x indicators RYB-01 No (c) Metering Section- Digital Ammeter showing 0-300 Amp with duly prewired with copper cable of suitalbe size with 3x2A SP MCB, 3 x indicators RYB-01 No (d) Insulated Busbar of Aluminium of 300A Capacity for 3 phase,, fixed on Insulators, Busbar shall be PVC Sleeved with red / Yellow/ Blue Colour, Busbar Support shall be of SMC/DMC - 1 set. (e) Outgoing MCCB 160 Amp , Four Pole, Thermal based release with adjustable O/L ,Adj S/C Setting Class II Front Face, 25KA rupturing capacity, Ics=100%Icu, Isolation with Positive Break Indication , Standard Extended Rotary Handle, Spreaders, Phase Barrier- 1 No
(f) Outgoing MCB 32 Amp , Four Pole, 10kA breaking capacity with fault indication .- 1 No (g) MCCB AUXILARY CONTACTS 1 CO (h) TRIP ALARM CONTACT (j) SHUNT TRIP 220VAC (k) EMERGENCY STOP PUSH BUTTON STAY PUT MASHROOM HEAD WITH ELEMENT (l) 06A SP 10KA MCB - FOR CONTROL "C" CURVE (m) Star Delta Stater 50 kW
Ventilating fans of required size to dissipate the heat with automatic switching on/off of fans depending upon the temperature of the panel, 230VAC 1500rpm, 160cum/h flying leads Notes for LT Panels : 1. Make of Switch gear and Panel Board should be same . 2. All accessories prewired with suitable size copper wire with stand high temperature, housed in cubical panel made out of 3.15 MM thick MS/CRCA sheet factory made duly powder coated front and rear door open able with locking arrangement complete with foundation as required or recommended by manufacturer.
Excaving trenches not exc 1.5m wide and not exc 1.5 mtr deep and getting out in any type of soil complete all as specified and directed .
Returning filling in (soil) including spreading levelling, watering and well ramming in layers not exc 25 cm thick all as specified and directed by Engineer -in-charge.
Removing excavated material (soil) to a distance not exceeding 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed.
Supply, lowering,commissioning & testing of Submersible pump capacity 45 Hp, 6 stages, discharge 1500 LPM at head of 80 mtr with out let size 100 mm dia bore including electric motor driven 415 V 50 HZ complete all as specified and directed.
Supply, lowering,commissioning & testing of Submersible pump capacity 50 HP, 1650 LPM at head of 80 mtr with out let size 100 mm dia bore including electric motor driven 415 V 50 HZ complete all as specified and directed.
Supply and fix in replacement of submersible flat 16 Sqmm, 3 core copper cable, 1100 volts conforming IS 694:1990
Supply and fix in replacement of submersible flat 10 Sqmm, 3 core copper cable, 1100 volts conforming IS 694:1990
Supply and fix in replacement of submersible flat 25 Sqmm, 3 core copper cable, 1100 volts conforming IS 694:1990
Supply in replacement of MS Nut bolts machine made with hexagonal or square head at one end screwed the other, each screws and to be fitted with washers and nut and suitable size of gasket, exc 5 cm but not exc 10 cm long and dia of bolt 10cm complete all as specified and directed.
Material and labour for Repair to pump house bore well cap cover made out from mild steel sheet 3 mm thick and angle iron frame in any shape and size complete with making holes , nut bolts welding etc as reqd at site including painting of two coat of synthectic enamel paint over a coat of red oxide complete all as specified and directed.
Supply and fix in replacement of MCCB 100 Amp , 3 pole, 415 volt, 16KA
Supply and fix in replacement of MCCB 200 Amp, 4 pole , 415 Volt, 36 KA
To attend elect complaint of water supply installations replacing burnt lugs of cable, to check auto star delta starter, voltmeter, ampere meter or any other items in pump panel changeover switch and make functional if minor repair involves to above equipments complete all as specified and directed.
Supply only Calcium based granual disinfectant for water treatement more stable than chlorine gas and stronger than bleaching powder and Calcium Hypo chlorite 65% to 70% Chlorine content in granular. (Packing in Plastic drum) as appoved by E-In-C's all as specified and directed.
Supply and fixing in replacement Digital Ampere meter.
Supply and fixing in replacement Digital Voltmeter.
Supply and fix in replacement Push Button Red & Green for On and Off.
Supply and fix in replacement 3 Phase indicater R,Y, B
Supply and fixing in repair / replacement of heavy duty chemical dozing system plunjer type suitable to inject solution up to 25 LPH working pressure 10 kg /cm2 comprising dosing pump coupled with three phase electric motor of capacity 0.5 HP,1440 RPM assembly with agitator in one motor ,agitator with SS sweep blade duly FRP coated, FRP tank 150 ltrs capacity ,complete unit mounted on heavy duty MS fabricated frame duly anti corresive paint complete with chemical grade PVC NRV. alongwith control panel for Dosing pump suitable for model SSAPS/CDSPT/25 made of powder coated MS fabricated box consisting of LED indicator, digital Volt meter, Amp meter, Single phase preventor, High voltage low voltage protection.
Supply, lowering and fixing in replacement MS heavy duty flanged pipe 5.4 mm thick 150 mm bore or nearest higher size bore (length not less thatn 3 mtr each) MS Flanged not less than 15mm thick on both side, with drilled holes and welded to MS pipe, including material and labour for jointing, fixing with nuts, bolt, rubber packing complete all as specified and directed.
Supply, lowering and fixing in replacement MS heavy duty flanged pipe 5.4 mm thick 100 mm bore or nearest higher size bore (length not less thatn 3 mtr each) MS Flanged not less than 15mm thick on both side, with drilled holes and welded to MS pipe, including material and labour for jointing, fixing with nuts, bolt, rubber packing complete all as specified and directed.
Supply and laying Sand cushioning to cable with dry fine sand in trenches/ ducts of Water supply installation complete all as specified.
Material and labour in replacement for Ductile Iron fittings ISI marked for flanged or spigot socketed pipe such as tail piece, connecting pieces, bends tapers, tea pieces (single or double branch) any type and angle / radius and straight connecting piece suitable for upto 250 mm bore pipe complete all as specified and directed.
Supply and lay in replacement ductile Iron, S/S including specials, Class “K-7” ,200 mm (8”) dia including rubber gasket complete all as specified and directed by Engr in Charge.
Supply and lay in replacement ductile Iron, S/S including specials, Class “K-7” ,150 mm (6”) dia including rubber gasket complete all as specified and directed by Engr in Charge.
Supply and lay in replacement ductile Iron, S/S including specials, Class “K-7” ,100 mm (4”) dia including rubber gasket complete all as specified and directed by Engr in Charge.
Supply and fixing in replacement 3- layer PP-R Polypropylene random copo?lymer) conceal?ed pipes SDR 7.4 (PN16) UV stabi?lized and antimi?crobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches all as specified and directed.
Material and labour for painting with approved color to existing MS/ GI pipe (rising main, delavery, over flow and washout) of size 150 mm dia 30 mtr height over head tank with two coat of synthetic enamelled paint including scrapping out old paint all as directed Note : All T & P, 30 mtr staging mtrl and men power risk contractor responsibility
Material and labour for chequared 6 mm thick MS plate for duct cover complete all as specified and directed by Engr in Charge.
Taking out old DI pipe upto 200 mm dia and cleaning and rectifiy the leakages and change Rubber gasket or fittings required on ground , replacement of broken pipe etc all as specified and directed by Engr-in Charge. Note : (I) Required pipe , DI / PPR fittings and Excavation to be paid separately.
S & F DWC high density polyethelene pipes in replacement having dia 63 mm / 50 mm, inner as per site requirement having corrugation on the wall and plain surface on the inner wall conforming to IS: 14930 (Part-I & II) for protection of underground cable laid along pole/ along wall / in PCC on GL/ Roof and including all fittings as required at site complete all as specified and as directed.
pee kay construction
Bharat Builder
Mahajan Builder
CHINAR ENGINEERS AND BUULDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .