Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.5 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹45.4 L+₹1.5 L (3.42%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹46.9 L+₹3.0 L (6.77%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹48.5 L+₹4.6 L (10.5%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹41.5 L
EMD Value
₹83,000
Closing Date
11 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 869 EWS
GE 869 EWS C/o 99 APO Pin-913869
SPL REPAIR TO CHAIN LINK FENCING AND CERTAIN E/M WKS NEAR BLDG. NO P-75 AND CERTAIN REVENUE WORKS AT LEIMAKHONG MIL STN
2022_MES_554069_3
8441/E8
Open Tender
Civil Works
Item Rate
210 days
LEIMAKHONG MIL STN
AS PER TENDER DOCUMENTS
2 documents required · 2 mandatory
₹500
GE 869 EWS
₹83,000
Yes
29 Apr 2023
20 Jan 2023
13 Feb 2023
20 Jan 2023
11 Feb 2023
28 Jan 2023
Amount
Schedule 'A'
Dismantling of existing RCC/ Steel /Wooden posts or struts (wood, steel or R.C.C.) any section,concrete ,brick work ,massonery etc . including taking out embedded portion and making good disturbed ground complete all speciified and directed
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, and getting out in hard/dense soil complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cms thick in soils complete all as specified and as directed.
Removing excavated material (soil) not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed.
M & L for PCC 1:4:8 Type D2 (Nominal mix) (using 40mm graded stone aggregate), as in foundation, filling and mass concrete complete all as specified and as directed.(Note:- using dimapur sand)
M & L for PCC 1:3:6 Type C2 (Nominal mix) (using 40mm graded stone aggregate), as in post holes, foundation, filling and mass concrete complete all as specified and as directed.(Note:- using dimapur sand)
M & L for PCC 1:2:4 Type B2 (Nominal mix) using 40mm graded crushed stone aggregate as in wall or retaining wall, any thickness, size or shape including pilasters, buttresses coloumn, pillars, boundary pillar and posts (including caps and bases) complete all as specified and as directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws as specified.
S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges, hips, valley gutters, drip, straight flashing etc fixed with self tapping screws as specified.
S&F 0.63mm plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip, wall cladding and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as directed.
Dismantling framed steel trusses span nexc 10m complete all as specified and as directed by the Engineer-in-Charge
Demolition of cement concrete un-reinforced of any description and any position not otherwise specifically provided for complete all as specified and directed.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor and pavings not exc 15 cm thick thickness below or above ground level complete all as specified and directed.
S&F structural steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St.-240 complete all as specified and as directed.
S&F Structural steel work in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe 410-W (Grade E-250) quality-A complete all as specified and as directed.
M&L for Expanded metal weight n.exc 4kg per sqm , cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members complete all as specified and as directed.
Erection and Re-fixing only steel work in tubular trusses/post including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161-1998 grade St-240 complete all as specified and as directed. (Note:- serviceable material obtained from item no 12.00)
S & F rolled mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe 410-W (Gde-E-250 quality-A) complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed. Note :-Dismantling of false ceiling to be carried out carefully without damaging existing fitting and fixtures of flase ceiling items
S&F exposed GI powder coated snap grid frame work for false ceiling of grid size 600 x600mm comprising of wall/cleat angle of size 25 x25 x0.35mm and main/cross tee of size 24 x38 x0.70mm with 4mm dia GI wire as suspender and including 4mm thick Plain E-Board including fixing arrangement from steel truss of any type and applying two coats of oil bound distemper over one coat of chalk whiting complete all as specified and directed.
M&L for 2nd class hardwood weather boarding, clean sawn, plain, 20mm thick or feather edged 15 mm to 20mm thick and fixed with 30mm laps complete all as specified and directed
M & L for 4mm thick plywood (no of ply 03), grade BWR, type BB fixed with nails or screws to timber frame work complete all as specified and directed.
M & L for preparation of new or previously untreated wooden surfaces of any description, not otherwise described, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer on wooden surfaces complete all as specified and directed.
M & L for preparation of new plastered surface of walls and applying two coats of soil emulsion distemper over one coat of cement primer and putty complete all as specified and directed
M&L for preparation of old painted wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of new or previously untreated surfaces of steel of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for preparation of old painted surfaces of steel of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M & L preparation of newly plastered surfaces and applying three coats of white wash on wall on all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc. 1.5 sq. m each and removing all unserviceable materials from site complete all as specified and directed.
S&F 2nd class hardwood plain solid straight chowkhats and frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints complete all as specified and directed.
S&F 30mm thick factory made flush shutter, solid core construction with block board core and plywood face panels, commercial type on both sides kiln seasoned and chemically pressure treated complete all as specified and as directed.
Supply & Fix for 30mm thick factory made of shutter 2nd class HW glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); kiln seasoned and chemically pressure treated complete as sepecified and directed by Engineer-in-Charge.
Dismantling timber scantlings 40 sq. cm and over in section, in unframed work and in any position complete all as directed.
M&L for well seasoned 2nd class hard wood in scantling, clean sawn timber framed work complete all as specified and directed.
S & F in door or window frame of any description with aluminium sections, coloured powder coating not less than 50 micron and fixing in position including all necessary cleats, lugs, breading and jointing arrangements complete all specified and directed
M & L for Anodised aluminium powder coated sliding window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. including all fitting complete all as specified
M & L for 4.8 mm thick plain tinted sheet glass, ordinary quality and glazing with including necessary joining cleats, glazing clips, rubber packing in any shape n exc 0.5 sq. m in each pane for aluminum window complete all as specified and directed
S & F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F, angle iron (Fe-310) as in posts, struts in fencing,gate including cutting top to shape required, drilling holes, notching for wire etc complete all speciified and directed
M&L for PCC M10 grade (Nominal mix) using 20mm graded stone agg as in hold fast etc. complete all as specified & directed.
M&L for Framed work as in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to beprepared for hangingor slidingwith and including either hooksand hinges or steel hangingdoor fittings (exclusive of steelsheeting or other covering,running rails and guides) and hanging; also fastening andfixing complete all as specified & directed.
M&L for Hand rails, half round or other steel section or core for wooden hand-rail straight portion,drilled and countersunk for balusters running bars, fordoors, balusters, nosing to steps including embeding in concreteand screwing etc. wind ties forroof including securing bolts; posts and struts in fencingn including cutting tops to shapeas directed, drilling holes,notching for wire, etc.; flat ironfillets (for securing wire meshetc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165 complete all as specified & directed.
S&F Mild steel machine made screw bolts with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed ends to be fitted with washers and one hexagonal or square nut of length of bolt exc 30 cm with dia of neck exe 20mm bot n. exe 25mm complete all as specified & directed.
Supply only Chain link MS galvanisd fencing, any size complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed.
S&F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at rossings with and provision of galvanised mild steel wire, taples or steel pins, etc. as directed each line wire to be measured) complete all as specified and directed.
M&L, two coats of synthetic enamelled paint over a coat of red oxide primer including preparation of new steel/iron surfaces not exceeding 10cm width or girth.complete all speciified and directed
S&F 100mm long butt hinges medium weight cold rolled mild steel complete all as specified and directed.
S&F 150mm long aluminium anodised of extruded section barrel tower bolts complete all as specified and directed.
S&F 150mm long alumiunium handles cast type anodised complete all as specified and directed.
S&F aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolt of extruded section or cast aluminium alloy and fixed 300mm long complete all as specified and as directed.
S&F floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor with 150mm overall length of cover plate complete all as specified and directed.
M & L for RCC 1:2:4 Type B1 nominal mix (using 20mm graded crushed stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; basesfor columns, etc.; basement slabs, under-reamed piles and mass concrete vcomplete all as specified and directed.
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, flat, rough finished surface of concrete complete all as specified and directed.
M&L for Reinforced cement concrete ( nominal mix) type B1 (1 :2:4)(using 20 mm graded stone agg.)in roof beams , cantilevers , bressummers , lintels over 1.5 m span complete all as specified and directed.
Formwork to soffits of suspended slabs as roof slabs, floor slabs, landinqs, lintel / chajja and similar work not exceeding 200 mm thick for fair finished surfaces of concrete complete all as specified and directed.
M & L for mild steel TMT bars 10mm dia and over, cut to length bent to shape required, including cranking bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and directed.
Ditto as per item no 61.0 but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.
M&L for Joint free Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 15 mm thick screed bed in CM 1:4 complete all as specified and directed.
M&L for Joint free Non - skid Ceramic tiles in vertical surface 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in skirting/dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 10mm thick plaster in CM 1:3 as backing coat to receive tiles complete all as specified and directed.
M & L for non skid coloured ceramic tiles 7 to 8mm thick jointless (Square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed.
M & L for Glazed Coloured Ceramic tiles in vertical surface 350x250x7mm / 450x350x7mm thick jointless set and joint in neat cement slury and pointed in white or colour cement to match over and including 10mm thick plaster in CM 1:4 as backing coat to receive tiles complete all as specified and directed.
M & L for 75 mm thick cement concrete type C-2 1:3:6 using 40mm graded aggregate as in sub base complete all as specified and as directed by the Engineer-in-Charge
M&L for 75mm thick PCC 1:3:6 Type C2 (Nominal Mix) using 40mm graded crushed stone aggregate as in plinth protection finishing surfaces even and smooth without using extra cement complete all as specified and directed.
M & L for 100mm thick cement concrete type C-2 1:3:6 using 40mm graded aggregate complete all as specified and as directed by the Engineer-in-Charge.(Sand :- USe Dimapur sand)
M&L for Forming Contraction (Dummy) joints 75mm deep x 10mm wide, filled with sealing compound grade 'A' complete all as specified and directed
S & F 1.25mm thick steel rolling shutters without ball bearing of gear oerated type with bevel gear box and crank handle as specified, including top cover, anchoring rod, hasp & staple and one shop coat of primer; erected in position as indicated complete all as specified and directed.
S & F ball bearing for rolling shutters erected in position as indicated complete all as specified and directed.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and pre-cast concrete articles and removing unserviceable materials from site of work complete all as specified and directed.
M&L for Hardcore of broken stone or boulder of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for brick work with subclass ‘B’ bricks, (locally available best quality) old size bricks straight or curved on plan exc 6 m means radius, built in cement mortar (1:6) complete all as specified and directed.
M&L for brick work with subclass ‘B’ bricks, (locally available best quality) old size bricks straight or curved on plan exc 6 m means radius, built in cement mortar (1:6) except bricks complete all as specified and directed. (Note:-servicable bricks obtained from item no 74.00)
M & L for brick work with sub class ‘B’ brick, old size (locally available best quality) straight or curved on plan to any radius in half brick thick wall built in cement mortar (1:4) complete all as specified and directed.
M & L for brick work with sub class ‘B’ brick, old size (locally available best quality) straight or curved on plan to any radius in half brick thick wall built in cement mortar (1:6) complete all as specified and directed.
M & L Rendering 15 mm thick in cement and sand mortar 1:4 on fair faces of brick work or cement concrete surfaces including finishing the surface fair and evenwithout extra using cement
M&L for PCC 1:2:4 Type B1 (Nominal Mix) using 20mm graded crushed stone aggregate as in coping incl necessary formwork complete all as specified and directed.
M & L for rendering 15mm thick plaster in cement mortar (1:6) on other than fair faces brick work or concrete surfaces finish the surfaces even and smooth without using extra cement complete all as specified and as directed. (using Dimapur Sand)
M&L rendering 15mm thick on other than fair faces of brick work in cement mortar(1:4) using water proofing compound @2% by weight or cement as per manufacture instruction and finishing even and smooth without using extra cement all as specified. (Note: Plastering shall be carried out using Dimapur Sand. Note: WPC will be measured and paid separately)
Supply only intergral water proofing compound ISI marked complete all as specified and as directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper using Airless spray technology with max working pressure of 3300 PSI and capable of operatinh single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on surface complete all as specified and directed. Note :- (a) Sanding of surface to be done by mechinical sander with 1500-2700 rpm, with internal dust extraction system for cleaning environment certified by paint manufacturer. Proper mixing to be carried out before primer and paint application. (b) The work pertaining to periodical services & water proofing shall be excuted as per manufacturer instructions of which the materials i.e Paint, Distemper, Putty etc is proposed to be used by contractor and approved by Garrison Engineer. (c) Cost of scaffolding as per requirement of building height is included in this item.
Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a one coat primer complete all as specified and directed.
Taking up or down 15mm dia of steel tubing and connections and removal from site complete all as specified and directed.
S&F GI tubing 15mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
Cutting chases, pinning in. Making good to facings on brick wall where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed.
Taking up or down 20mm dia of steel tubing and connections and removal from site complete all as specified and directed.
S&F GI tubing 20mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
Disconnecting existing water tanks capacity exc. 250 litres and n.exc. 500 liters, setting aside (or lowering if required ) for repairs, cleaning, etc. and hoisting if required reconnecting and refixing in position complete all as specified and directed.
S&F rotational moulded polyethylene water storage tank, ISI marked, 1000 litres capacity of multilayered layer wall construction (Cylindrical, vertical with closed top) hoisted and fixed in position including all necessary inlet/outlet connections & brass ball valve complete all as specified in SSR Part-I and as directed.
S&F Gun metal, globe or gate valves, ISI marked with iron wheel head, screwed both ends for iron pipe for 20 mm bore dia of pipe and fixed complete all as specified and directed.
M&L for providing cement concrete 1:3:6 Type C1 in lintels upto 1.5m clear span, cills, steps; seismicand other similar bands,plinth courses, string courses,lacing courses,parapets and railings upto 60 cm in height,copings, kneelers, apex stones,bed plates, watertroughs and the like includingweathering, slightly rounded or chamfered angles andthroating complete all as specified and directed.
S&F brass chromium plated, 600mm long between flanges tubular towel rail , 20mm dia, D type. fixed with and including chromium plated brass screws and wooden plastic cleats, complete all as specified and directed.
S&F stainless steel sink with drainage board 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm. (Make: Blue Star Model No BSSBSD-52 or equivalent in Jain Brothers / Prayag/ Cera)
S&F in repair stainless steel plate rack of size 24" x 36" x 10" complete all as specified and directed. (Make: Blue Star cat No KPR-312 or equivalent in Nirali/Jain Brothers/Prayag)
S & F in repair coloured wash basin, vitreous china (flat back or angle back type), white, (550 x 440) mm size, white, waste fittings including waste coupling, 32mm dia, waste pipe,PVC connection 45 to 60cm long complete all as specified and directed.
M & L for Soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and as directed
S & F vitreous china wash down water closet pan (pedestal pattern) white with plastic seat, closed pattern with flat bottom and with ‘P’ or ‘S’ trap (excluding flushing cistern and flush pipe) including all fitting complete all as specified and as directed.
S&F in repair PVC low level flushing cistern, white, 10 ltrs capacity, valveless, syphonic action type including all fittings and flush pipe, PVC connection pipe 600mm long 15mm bore with brass heads and washers all as specified and directed.
S & F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long fixed to walls with screws complete all as specified and directed.
S & F in repair 15mm bore bib taps, cast copper alloy, chromium plated long shank with capastain head fancy screwed down, screwed for iron pipe or for brass ferule complete all as specified and directed.
S&F pillar taps, ISI marked cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks for iron pipes for 15 mm bore dia of pipe and fixed complete all as specified and directed.
S&F 125mm size chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed.
S&F stop valves, ISI marked, 15 mm dia cast copper alloy, chromium plated, fancy type, with long shank and cup (concealed type) screwed down high pressure, screwed both ends for iron pipe or unions complete all as specified and directed.
S&F in repair stop valves, ISI marked, 15 mm dia cast copper alloy, chromium plated, fancy type, with long shank and cup (concealed type) screwed down high pressure, screwed both ends for iron pipe or unions complete all as specified and directed.
S&F of CP brass, chromium plated angle stop valves of 15mm bore fancy type screwed down high pressure, screwed both ends for iron pipe or unions complete all as specified and directed.
S&F in repairs brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed for 15 mm bore dia of pipe and fixed complete all as specified and directed.
S&F 75mm dia PVC (SWR) floor trap / Gully trap plain with grating including setting and jointing with solvent cement complete all as specified and directed.
S&F Grating square 100 mm size of PTMT complete all as specified and directed. (Minimum weight 25gms)
S&F 75mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints and fixed to wall with steel clamps or laid in trenches or in floor as in waste/soil pipe complete all as specified and directed.
S&F 110mm bore PVC (SWR) bend door type complete all as specified and directed.
S&F 75mm bore PVC (SWR) bends complete all as specified and directed.
S&F 110mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed.
S&F in repair 20mm dia harrison rails of anodised aluminium alloy with fixing brackets, stops, rollers etc.complete all as specified and directed.
M & L for machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with gray cement and pigment complete all as specified and directed.
M & L Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
M&L for precast cement concrete chequred tiles (ISI approved) of size 300mm x300mm x25mm thick, set and jointed and pointed in neat cement slurry in floor with grey cement and pigment including 20mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors laid bedded and pointed in any mortar complete all as specified and directed.
M&L 20mm granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
M&L 18/19mm particle board medium density flat pressed single line layer type or three layer type with BWR type adhesive fixed with screws to timber frame work. Including leaping complete all as specified and directed.
M&L 0.9mm decorative laminated type 1, of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions.
S&F 30m wide continuous (piano) hinges, mild steel, bright finish or electrogalvanised complete all as specified and directed.
S&F 40mm dia cupboard knobs fixed with nuts, screw and washer of mild steel bright finish complete all as specified and directed.
Mateirial & labour for Preparation of old decorated surfaces of wall including washing, rubbing down and stopping of distempered and painted surfaces ,brooming , scraping down. Smoke spot, moss, efflorescent salts, trading oil, grasy spots and stopping nails marks by applying white cement base putty in patches as required and one coat of oil emulsion distemper all as specified and directed.
S & F Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed.
S&F Galvanised iron strip 32 x 6 mm with saddles and fixing screws etc complete all as speicified and directed
S & F Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed.
S uppy an dlaying 40mm bore GI tubing light grade with all fittings complete in walls, ceiling or in floors complete all as specified and directed.
Point wiring completed with 1.5 Sqmm (nominal area) PVC insulated unsheathed stranded copper conductor cable in and including ERW rigid conduit (slove enameled) concealed conduit for one light point/fan point/5 Amp multipurpose switch socket with other than FP junction box, FP bend, FP reducer independent for 2 light point controlled by one (MCB) including copper wire as specified above for earth wire to common earth and connected to earth dolly complete all as specified. Following and all another flame proof fitting for wiring shall be incorporated in wiring as required basic and cost there of shall be included in the rate quoted (a) Flame proof junction box 3 way suitable for 3/4'' ET conduit material LM-6 (b) Flame proof junction box 2 way suitable for 3/4'' ET conduit material LM-6 (c) Flame proof junction box 3 way suitable for ET conduit material LM-6 (d) Supply and fixing flame proof union suitable for 20mm dia ERW conduit complete all specified and directed.
Supply and fixing flame proof rotary type switch with terminal box in cast aluminium alloy (LM-6) construction, epoxy powder coated, single pole 16 amps on off type 250 V AC certified by CRMI for Group II A & II B completed including compression glands complete all all as specified and directed
Supply & fixing LED light fitting 1 x 16 watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, zone 1 & 2 and IP 65 protection with die cast aluminium housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed
Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized iron earth strip of size 32x6mm by means of galvanized iron or steel bolts nuts check nuts and washers and other end connected with earthing testing point including providing suitable testing points as directed including funnel, watering pipe of 20mm bore, light grade galvanized iron pipe, wire mesh charcoal of coal dust and common salt in alternative layer all around the earth electrode compacted thickness 15cm with concrete pit in PCC 1:3:6 type C1 50mm thick pre cast RCC 1:2:4 type B1 cover slab set in CM (1:4) re-enforcement with 8mm dia deformed bars @ 15cm C/C and suitable handle of 10mm dia MS round bars, including earth work in hard/dense soil as required complete all as shown in electrical plate No 3 of MES Schedule Part I and testing on completion all as specified and as directed. (Note: GI Earthing lead upto 7.5m in length is deemed to be included in the unit rate. The lead required beyond 7.5m shall be measured and paid for separately)
Taking down copper/aluminium point wiring (light, fan, socket or power) complete including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing unserviceable materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc. complete all as specified and directed
M & L for point wiring surface type with two single core 1.5 Sq mm (nominal area) FRLS PVC insulated and unsheathed,multi-stranded, copper conductor cable in and including suitable size PVC casing capping with all fittings and fixing accessories and suitable size PVC box for mounting switches, regulatorete including multi-strand PVC insulated unsheathed stranded copper cable as earth continuity conductor of size 1.5 Sq mm and connecting to light fitting/fans etc complete all as specified and directed for following : - ( colour code to be followed). (a) One light point controlled by one, one way switch.
(b) One celling / exhaust fan point controlled by one, one way switch.
(c) One socket outlet 5 Amps 5 Pin on independent board
(d) One socket out let 5 Amps 5 pin on same board
All as per item No 2 here in before but with cable size 2.5 Sq mm for one 5 pin 15 Amps socket out let on independent board and multistrand insulated copper earth continuity conductor of size 2.5 sqmm complete all as specified and directed (ciruit to be laid seperatly )
S&F modular switch, 6 Amps, single pole, one way complete all as specified and directed.
S&F modular socket outlet 2/3 Pin 6 Amps combined 2 module complete all as specified and directed.
S&F modular socket multipurpose 3 pin 16 Amps and 3 pin 6 Amps combined 2 module complete all as specified and directed.
S&F Ceiling rose, 3 terminals, PVC/ polycarbonate, isolated body complete all as specified and directed.
S&F modular switch, 16 Amps, single pole, one way, one module complete all as specified and directed.
S&F modular white cover plate with frame for fixing of 8 module.
S&F modular white cover plate with frame for fixing of 3 module.
S&F modular white cover plate with frame for fixing of 2 module.
S&F blank spacer plate for single module.
S & F modular step type two module electronic fan regulator heavy duty 120watts 240 volts
Taking down old unserviceable main switch/ DBs/ MCB DBs with MCB including making good the disturbed surface complete as directed.
S&F sheet metal enclosure for MCB’s distribution board, 240 Volts, 12 ways single pole and neutral including 200 Amps rated busbar, neutral link, din rail double door complete all as specified and directed.
S&F sheet metal enclosure for MCB’s distribution board, 240 Volts, 8 ways single pole and neutral including 200 Amps rated busbar, neutral link, din rail double door complete all as specified and directed.
S& F sheet metal enclosures SPN , DB of 4 way double door with neutral earth dolly with 200 amps rated complete all as specified and directed.
S&F MCB single pole and neutral 32 Amps, ‘C’ series 240 Volts, breaking capacity 10KA complete all as specified and directed.
S&F MCB single pole 06 to 32Amps, ‘C’ series 240 Volts, breaking capacity 10KA complete all as specified and directed.
S&F PVC Board (30 x 25 x 5) cm depth medium quality ISI marked complete all as directed.
Supply and fixing in repair LED lights fitting 1x20 Watt, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed
S & F LED light fitting 1x9W / 1X10W bulk head luminaires including LED light driver holderconnecting up with three core flexible copper conductor cable of suitable for surface and wall mounting complete all as specified and directed.
Taking down old unserviceable service cable from and including battens/ suspending wires complete all as specified and directed.
S&F Service wire connection with one twin core 10 sq mm, 2 core, 1100 volts grade heavy duty flat or circular cable, multi stranded aluminium conductor, PVC insulated served with inner sheathing of PVC tape armoured, suspended by insulating hangers not more than one mtr apart incl 4mm dia GI suspension wire complete all as specified and directed.
Taking down Ceiling fan/Exhaust fan, dismantling blades and kept in safe custody for refixing to its origianl position including provision of cable from ceiling rose or connected to fan complete all as specified and directed
Refixing ceiling fan/exhaust fan received from item No - 21 here in before and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed
S & F ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, with squirrel cage induction motor complete all as specified and directed
S & F exhaust fan made of sturdy engeineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm complete all as specified and directed
S & F in repair Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 20 watts with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting and GI pipe bracket made out of GI pipe medium grade 32 mm dia 1.5 mtr long bend to required shape complete incl removal of old unsv fitting all as directed by Engineer-in-Charge.
M & L earthing complete with GI earth plate Electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth plate not less than 2.25 Metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanished earth wire 4.0 mm dia by means of bolts, nuts check and washers of G I or steel all as shown in electrical plate No. 3 of SSR Pt -I connected to earthing test point all as specified or indicated including GI pipe 15 mm dia light grade for earth wire protection, necessary excavation, earth work in any type of soil, PCC chamber and RCC cover slab, connecting lead wire from test point to DB complete all as specified & as directed.
M/S BIJOYA LAXMI ENTERPRISE
L BINOD CONSTRUCTION CO
M/s Ritz Marketing
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .