Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹73.5 LAdmitted-Finance 26 3 3RD CROSS GANESHA BLOCK SULTANPALYA RT NAGAR POST BANGALORE 560 032 | BANGALORE | BANGALORE | KARNATAKA | 560032 | L1 | Admitted-Finance | |
| 2 | L2₹78.4 L+₹5.0 L (6.75%)Admitted-Finance NO 49 MSN NILAYAM 3RD CROSS HILL VIEW GARDEN TUNAHALLI SUBRAMANYAPURA POST BANGALORE 560061 | BANGALORE | BANGALORE | KARNATAKA | 560061 | L2 | Admitted-Finance | |
| 3 | L3₹82.4 L+₹8.9 L (12.2%)Admitted-Finance NO 12 5TH B CROSS SHARADAMBA NAGAR M E S ROAD BANGALORE 560013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L3 | Admitted-Finance | |
| 4 | L4₹84.4 L+₹10.9 L (14.9%)Admitted-Finance 20 1ST A CROSS SAI NAGAR AREHLLI UTTARHALLI BANGALORE 560 061 | BENGALURU URBAN | KARNATAKA | 560061 | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | PRAGATHI BUILDERS L2 | K. VENKATESH NAIDU L4 | Shanthi Construction L3 | G K CONSTRUCTIONS L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above GL) all as specified and directed. | 26.88 | Cum | 510 ₹13,706.25 Lowest | 700 ₹18,812.5 | 600 ₹16,125 | 600 ₹16,125 |
| 2.00 | Taking down PVC pipes of 150mm dia (pipes for valley gutter) all as specified and directed. | 65 | RM | 100 ₹6,500 | 115 ₹7,475 | 200 ₹13,000 | 80 ₹5,200 Lowest |
| 3.00 | Dismantling of Plain or corrugated galvalume/carbonate sheet in roof covering / steel sheeting of any guage fixed on valley gutters including securing MS flat and screws etc and removal from the site all as specified and directed. | 1,437 | Sqm | 100 ₹1,43,700 | 95 ₹1,36,515 | 250 ₹3,59,250 | 60 ₹86,220 Lowest |
| 4.00 | Taking down cement plaster on brick work or stone wall etc including racking out joints, hacking for key, scrubbing down with water etc all as specified and directed. | 200 | Sqm | 50 ₹10,000 | 65 ₹13,000 | 50 ₹10,000 | 40 ₹8,000 Lowest |
| 5.00 | Dismantling of wrought iron or mild steel work of any description not otherwise provided for all as specified | 2 | Qtl | 600 ₹1,200 | 750 ₹1,500 | 500 ₹1,000 Lowest | 900 ₹1,800 |
| 6.00 | M& L for rendering 10mm thick cement plaster in CM 1:6 on fair faces of brick work on concrete surfaces including finished even and smooth all as specified and directed. | 140 | Sqm | 280 ₹39,200 Lowest | 350 ₹49,000 | 300 ₹42,000 | 330 ₹46,200 |
| 7.00 | M& L for rendering 15mm thick cement plaster in CM 1:4 on fair faces of brick work on concrete surfaces including finished even and smooth with water proofing compound (Water proofing compound shall be measured and paid seperately) all as specified and directed. | 60 | Sqm | 325 ₹19,500 Lowest | 380 ₹22,800 | 325 ₹19,500 Lowest | 349 ₹20,940 |
| 8.00 | Supply only integral waterproofing compound. | 20 | Kg | 150 ₹3,000 | 140 ₹2,800 | 120 ₹2,400 Lowest | 130 ₹2,600 |
| 9.00 | Material and Labour for preparation of new decorated plastered surfaces of walls and applying three coats of white wash complete all as specified and directed. | 140 | Sqm | 20 ₹2,800 Lowest | 30 ₹4,200 | 60 ₹8,400 | 24 ₹3,360 |
| 10.00 | M& L for preparing new plastered surfaces of walls and applying two coats of cement base paint all as specified and directed. | 60 | sqm | 80 ₹4,800 | 100 ₹6,000 | 65 ₹3,900 | 55 ₹3,300 Lowest |
Tender Value
Refer Docs
EMD Value
₹1.1 L
Closing Date
4 Apr 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COL MANOJ NEGI
CWE AF North Bangalore Bellary Road JC Nagar Post Bangalore 560006
IMPROVEMENT TO BUILDING NO P-393/2 AT 26ED AF UNDER GE (AF) MARATHAHALLI
2021_MES_498328_8
87690CWEAFNMAR
Open Tender
Civil Works
Item Rate
240 days
GE (AF) MARATHAHALLI
AS PER NIT
6 documents required · 6 mandatory
₹1,000
GE (AF) MARATHAHALLI
₹1.1 L
Yes
12 Apr 2023
10 Mar 2023
11 Apr 2023
10 Mar 2023
4 Apr 2023
21 Mar 2023
11 Mar 2023 - 14 Mar 2023
Amount
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above GL) all as specified and directed.
Taking down PVC pipes of 150mm dia (pipes for valley gutter) all as specified and directed.
Dismantling of Plain or corrugated galvalume/carbonate sheet in roof covering / steel sheeting of any guage fixed on valley gutters including securing MS flat and screws etc and removal from the site all as specified and directed.
Taking down cement plaster on brick work or stone wall etc including racking out joints, hacking for key, scrubbing down with water etc all as specified and directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for all as specified
M& L for rendering 10mm thick cement plaster in CM 1:6 on fair faces of brick work on concrete surfaces including finished even and smooth all as specified and directed.
M& L for rendering 15mm thick cement plaster in CM 1:4 on fair faces of brick work on concrete surfaces including finished even and smooth with water proofing compound (Water proofing compound shall be measured and paid seperately) all as specified and directed.
Supply only integral waterproofing compound.
Material and Labour for preparation of new decorated plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
M& L for preparing new plastered surfaces of walls and applying two coats of cement base paint all as specified and directed.
S & F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls of bore 150mm (pipes for valley gutter) all as specified and directed.
S & F Framed work (Fe 410 W grade E-250 Quality A) as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed.
M&L for anti-termite treatment (Post Construction) of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors all as specified and directed
M&L for anti-termite treatment (Post Construction) along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron all as specified and directed.
Removing building materials etc, to a distance of 10 km or above , beyond the lead included in the rates, including loading, unloading and stacking at the destination all as specified and directed.
S & F pre-painted galvalume sheet sandwiched with PUF sheet and bottom of plain galvalume sheet, Prepainted galvalume sheel shall be aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa sandwitched with PUF sheet of 50mm thickness and bottom of plain Galvalume sheet as in roof covering/ridges cladding to wall, fixed with self tapping screws all as specified and directed.
S & F 2 mm thick poly carbonate transparent roof glazing sheet fixed to existing steel purlin/steel membrance with non rust hidden screws and washer on overlap etc completeall as specified and directed.
S & F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strenght of 550Mpa as in roof covering/ridges cladding to wall, fixed with self tapping screws all as specified and directed.
M & L for PCC 1:2:4 type B1 (20mm graded aggregate) as in roof kerbs / PCC gola etc all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc.and Brushing neat cement slurry with 3.0kg of cement per sqm.
Material and Labour for 30mm thick wear proof topping mixed with approved metalic hardener, laid on concrete floor and pavings, finished even and smooth complete all as specified and directed. Note: 1) The floor hardner shall be mixed with crushed granite in the proporotion (1:2) by volume. 2) Metalic hardner shall be used 5 Kg/Sqm. 3) Metalic hardner shall be measured and paid separately.
Supply only metallic floor hardner.
M & L joint free coloured non skid ceramic tiles 7 to 8mm thick area of each tile exc 0.18 sqm but n.exc 0.38 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed 1:4 15mm thick all as specified and as directed
M & L joint free coloured glazed ceramic tiles on vertical surfaces of size 350x250x7mm/ 450x300x7mm, set and jointed in neat cement slurry and pointed in white or coloured cement to match including backing coat 10mm thick 1:3 on verical surface such as skirtings, dados risers to steps etc all as specified and directed.
M & L for preparation of old steel surface and applying one coat of Aluminium paint on steel surfaces all as specified and directed.
S&F plain galvanised mild steel sheeting 2 mm thick in ridges hips valley gutters , drip and straight flashing (length and girth as fixed) with grade of zinc coating 275 all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones
M&L 4 mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc. 0.5 Sqm in each pane
M&L 5.5 mm thick sheet glass ordinary quality and glazing with oil putty in square exc. 0.5 Sqm in each pane
Material and labour for preperation of old decorated wall surfaces including brooming down or steel wire brushing, scraping down smokes soot, module, moss and efflorescence salt, oil and greasy spots etc and applying two coats of white wash on wall complete all as specified and directed.
Preperation of old decorated wall surfaces including brooming down or steel wire brushing, scraping down smokes soot, module, moss and effloroscent salts, trading oil and gresy spots and applying one coat of cement based paint on walls complete all as specified.
Materials and labour for preperation of old decoratd surfaces of walls including washing, rubbing down and stopping of distempered surfaces and applying one coat of oil bound distemper complete all as specified & directed by Engr-in charge .
M&L for preparing old treated wooden surface over 10 cm width or girth with a filler coat of thin varnish or lacquer or shellac varnish and finishing coat with synthetic varnish all as specified and directed.
S&F mild steel works in Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 all as specified and directed.
M&L two coats of synthetic enamel paints over a coat of red oxide primer on steel surfaces over 10cm width or girth after preperation of new surfaces all as specified and directed.
M&L for PCC 1:3:6 type C2, 40 mm graded aggregate as in plinth protection (75 mm thick) finished even and smooth with using extra cement. Note: Joints of the plinth protection should be filled with sand and bitumen mortar and sealed with bitumen grading
M&L for filling joints of plinth protection 65 mm deep X 10 mm wide filled with sealing compound Grade A all as directed.
M & L for Groove cutting for concrete floor of size 10mm wide & 30mm Depth complete all as specified and directed.
M & L for filling construction joint with sealant compound (Thioflex 600PG) incl cleaning the grooves all as per manufacturers instruction.
S & F in repairs Self contained wind power design industrial turbo ventilator 60cm dia including ball bearing etc complete all as specified and as direced.
M&L for precast cement concrete Type B-1 (1:2:4) 20mm graded aggregate in cover slab for water troughs, drains etc all as specified and directed.
Mild steel TMT bars 10mm dia & over, cut to length bent to shape required, including cranking, bending spirally for hoping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed.
M & L for Powder coated Anodized Aluminium Frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. In repairs complete all as specified
M & L for Powder coated Anodised aluminium door shutters, aluminium section weighing 0.55Kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door hinges, anodised aluminium snap beading screws etc complete all as specified.
M & L for 12mm thk Particle board, medium density, flat pressed, single layer type or three layer type with BWR type adhesive, fixed with screws to aluminium frame work all as specified and as directed.
M & L for Anodized Aluminium snap grid frame work for false ceiling including provn of Hangers 6 mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by slabs by means of ceiling cleats made out of GI flat 40x3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia 40 mm long complete in repairs all as specified.
M & L 12mm thick Perforated particle board/tiles for insulation & acoustic purposes, 60*60cm in size, fixed with nails to timber frame work or with staples on snap grid all as specified.
S & F Ball bearing for rolling shutters in repairs all as specified and as directed.
M & L for Mild steel round bars 10mm dia & over, cut to length bent to shape required fixed for sliding shutters including removal of shutters and refixing in same position all as speicifed and as directed.
S & F rolled mild steel Fe-410-W(Gde- E-250) quality- B in Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment for ramp to withstand 5ton bearing load capacity of vehicle all as specified.
S & F Steel work in tubular trusses including special shaped washer,hinges etc. complete using ERW or induction butt welded tubes conforming to IS 1161- 1979 grade St.-240
M & L Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus hard/dense soil to a distance n exc 50 m and making good surface all as specified and as directed.
M & L Providing cement concrete type B-2, 1:2:4 (40 mm graded aggregate) in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) all as specified and as directed.
Taking down old point wiring for light/fan /5A/15A switch socket complete with switches/ switch sockets/ ceiling roses/Resistance type fan regulator / light fitting etc complete with all accessories.
Taking down submain wiring of any size and making good the disturbed surface of wall, floors, ceiling etc complete all as specified and directed
Taking down ceiling fan / Exhaust fan ,sealing cable end dismantling the fan blade kept in safe custody. re-fixing the same after the work completed with cleaning,servicing,painting and working condition all as per specified Note: cleaning servicing and painting of c/fan and Ex fan will be paid separtely
Taking down Unserviceble MCB DB,SPN,TPN with MCBs Main switch any rating
Point wiring with cable of FRLS copper multistranded conductor 1.5 sqmm 1100 volts grade drawn through in PVC conduit with all accessories fixing arrangements and all conduit accessories in conceled wiring fixed on ceiling / fixed to roof/truss/columns etc including provision of branded modular inner box and outer cover modular plate with frame and PVC surface type box of suitable size conceiled in wall, surface for housing switches / sockets / regulators etc with 1.5 sqmm PVC insulated multistranded copper earth continuity conductor connecting to common earth dolly complete all as specified and directed for the following Note:- Conduit pipes are run on surface/ wall where ever its required and making good the damaged wall/column/roof.Painting the wall to match the exisisting colour. (a) One light point controlled by one switch 5/6 amps AC 230 volts 50 Hz
(b) All as above item No 58 but of One ceiling fan/exhaust fan point controlled by one switch and a regulator
(c) All as above item No 58 but of One 5 amps socket point on independent board.
(d) All as above item No 58 but of One 5 amps socket point on the same board with other switches .
All as per item No 58 here in before but for using 2.5 sqmm copper conductor multi stranded for power points 15 amps all as specified and as directed.
Supply and fix Switch modular type single pole and one way 230 volts 5/ 6 Amps all as specified Make:- Anchor / Havells / L&T / Standard
Supply and fixing backalite ceiling rose two to three plate surface and jumpo type all as specified. Make:- Anchor / Havells / L&T / Standard
Supply and fixing for electronic fan regulator socket type modular type with 5 step speed control for fans all as specified.Make:- Anchor / Havells / L&T / Standard
Supply and fix Socket out let 3 /5 Pin, 5 / 6A modular type single pole and one way 230 volts 5 Amps all as specified Make:- Anchor / Havells / L&T / Standard
Supply and fix Switch modular type 16A modular type single pole and one way 230 volts 16 Amps all as specified Make:- Anchor / Havells / L&T / Standard
Supply and fix Socket out let 3/5 Pin, 15 /1 6A modular type single pole and one way 230 volts 16 Amps all as specified Make:- Anchor / Havells / L&T / Standard
Supply and fix for Sub main wiring complete with two runs of 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including PVC rigid conuit of 20 mm dia alongwith accessories on surface of wall ,roofs etc.,all as specified and asdirected. Make : Finolex / Anchor / polycab/ Havells Note : 2 Runs of PVC FRLS cable, one run of earth continuity conductor cable and one run of PVC conduit shall be measured as one length/running metre.Make : Finolex / Anchor / polycab/ Havells
Supply and fixing Sub main wiring complete with two runs of 2.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including PVC rigid conuit of 20 mm dia alongwith accessories on surface of wall , roofs etc., all as specified and as directed. NOTE :- 2 runs of PVC FRLS cable, one run of earth continuity conductor cable and one run of PVC conduit shall be measured as one length/running metre.Make : Finolex / Anchor / polycab/ Havells
Supply and fixing Sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including PVC rigid conuit of 20 mm dia alongwith accessories on surface of wall , roofs etc., all as specified and as directed. NOTE :- 2 Runs of PVC FRLS cable, one run of earth continuity conductor cable and one run of PVC conduit shall be measured as one length/running metre.Make : Finolex / Anchor / polycab/ Havells
Supply and fixing Sub main wiring complete with two runs of 6Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including PVC rigid conuit of 20 mm dia alongwith accessories on surface of wall , roofs etc., all as specified and as directed. NOTE :- 2 Runs of PVC FRLS cable, one run of earth continuity conductor cable and one run of PVC conduit shall be measured as one length/running metre.Make : Finolex / Anchor / polycab/ Havells
Supply and fixing Sub main wiring complete with four runs 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including PVC rigid conuit of 25 mm dia alongwith accessories on surface of wall , roofs etc., all as specified and as directed. Note :- 4 Runs of PVC FRLS cable, one run of earth continuity conductor cable and one run of PVC conduit shall be measured as one length/running metre .Make : Finolex / Anchor / polycab/ Havells
Supply and fixing in repairs LED Light fitting 2 x 20 W, Surface mounted , industrial box type luminaire with CRCA body, pre-coated in white & pre-wired for LED tube, bipin holders, connector block etc., including 20W - 2 Nos LED T8 tubular lamp with in built driver with all accessories and connecting up with 3 core 0.5sqmm copper wire between ceiling rose and fitting terminal complete all as specified and as directed Make : (i) Cat part No : IGP 132 LT8 - 16 of Crompton for fitting or equivalent model in Bajaj/Havells/ Philips (ii) Cat part No : LTT8-20 -865-2 of Crompton for LED light or equivalent model in Bajaj/Havells/ Philips.
Supply and fix 36 W LED, high efficacy 2 x 2 recess LED flat panel with high brightness LED for glare free homogenous illumination including LED driver complete all as specified. Make : Crompton (Polaris I) Cat No :LCTLRN-36-FO-CDL / Equivalent phillips/bajaj/ Havells
Supply and fix double stiff pendents, comprising of galvanised steel or chromium plated brass bell mouth connectors 02Nos with back plate and 2x1.5 m long paralleled 20mm dia galvanised or stove enamelled screwed steel conduit with two check nuts for fixing tube light fitting and upto 1.5 m long twin core 0.5 Sq mm copper conductor flexible wire all as specified and directed.
All as per item No 76 above but add for adjustment of extra length of conduit and flexible wire as specified.
All as per item No 76 above but deduct for adjustment of less length of conduit and flexible wire as specified.
Supply and fix MCCB DB TPN 4 way (Vertical), double door, 415 V, AC, 50 Hz, IP-43 protection conforming to IS-13032 universal mounting with copper bus bar, neutral link, earth link, earthing studs, detachable gland plates with knock outs on both sides all as specified Make: Legrand / ABB / Seimens / L&T
Supply and fixing sheet metal enclosure MCB DB SPN 8 ways double door type with suitable bus bar complete. Note :- (i) MCB TP / SP – as required will be measured & paid separately in relevant item. (ii) Rate deemed to be inclusive of Connecting the cables with Incoming /outgoing MCCB/MCBs with suitable Lugs & cable gland Make: Legrand / ABB / Seimens / L&T
Supply and fixing sheet metal enclosure MCB DB SPN 4 ways double door type with suitable bus bar complete. Note :- (i) MCB TPN as required will be measured & paid separately in relevant item. (ii) Rate deemed to be inclusive of Connecting the cables with Incoming /outgoing MCCB/MCBs with suitable Lugs & cable gland Make: Legrand / ABB / Seimens / L&T
Supply and fixingTriple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB all as specified and directed.
Supply and fix MCB SP 6 to 32 Amps,10KA, breaking capacity, 240Volts,50 Hz AC supply.Make: Legrand / ABB / Seimens / L&T
Supply and fix MCB SPN 6 to 32 Amps,10KA, breaking capacity, 240Volts,50 Hz AC supply.Make: Legrand / ABB / Seimens / L&T
Supply and fix MCB TPN 63 Amps rating'C' series10KA, breaking capacity, 415 Volts,50 Hz AC supply Make: Legrand / ABB / Seimens / L&T
Suppply and fix MCCB, 4 pole100 Amps, 25 KA ,breaking capacity, 415 volts, 50Hz.Make:Legrand/ABB/Seimens/ L&T
Material and labou for servicing ,painting of ceiling fan / Exhaust fan complete,insitu with synthetic enamelled paint by spraying including fiiling cavities with filler,one coat after cleaning all dust etc.
Taking down smoke detector,Hooter isolator switch SV lamp,fiood lights refixing same after repair work completed insitu with cleaning all dust and making working condition complete as specified Note:-All matrials to be kept in safe custody with out any damage at MES store same materials to be reuse after repair work completed.
Supply and fixing Entry / Exit display board , 3w single side display with 2 hours battery back up complete as specified and as directed Make Bajaj luminaire type BESL03 LED SSD WBB Red order product code : 220209 or equivalent to the makes specified in list of manufacturer here in after Make.Phillips/Bajaj/ Havells/ Crompton
Taking down carefully 30cm long Air termination rods with base plates and aluminium roof conductor including FRP insulators, after unscrewing nuts & bolts with washers and taking in safe custody and Material & Labour for proper refixing the same Alluminium conductor with new Expoy insulators for one metre on the roof sheets and on wall complete all as specified and directed by Eng - in -Charge Note.Same items to be reused after repair work completed in good condition properly..
Aluminium strip 25 x 3.15mm with saddles and fixing screws etc,for roof conductors and down conductors above ground.
M&L for earthing complete with galvanized steel earth plate electrode 600X600X6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5M below normal ground level connected to GI 32x6 strip through 40 mm GI pipe as earthing lead protection and 20mm GI pipe is connected water pouring funnel up to earth plate as earthing lead means of nuts, bolts, check nuts and washer of GI steel and connecting to testing point including provision of test point and all as shown in electrical plate No. 3 of SSR Pt I. The work is inclusive of necessary earth work and PCC chamber in type CI (1:2:4) with 8 CTD bar reinforcement both ways at 140 mm bents to centre complete all as directed by Engr-in-Charge. (for lightning arrester) Note:- GI earth strip beyond 7.5M shall be measured and paid separately. Note:-(i)Earth pit is required to be identified by Earth board. Earth Board Details are as under 1. EARTH PIT NO : EQ/ PS/ XXX 2. DATE OF MEASUREMENT : ................... 3. NEXT DUE DATE : ................... 4. STANDARD VALUE : ................... 5. VALUE OBTAINED : ...................... 6. MEASURED BY : ....................... 7. SUPERVISED BY : ........................
M&L for earthing complete with galvanized steel earth plate electrode 600X600X6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5M below normal ground level connected to 4.0 mm GI wire through 40 mm GI pipe as earthing lead protection and 20mm GI pipe is connected water pouring funnel up to earth plate means of nuts, bolts, check nuts and washer of GI steel and connecting to testing point including provision of test point and all as shown in electrical plate No. 3 of SSR Pt I. The work is inclusive of necessary earth work and PCC chamber in type CI (1:2:4) with 8 CTD bar reinforcement both ways at 140 mm bents to centre complete all as directed by Engr-in-Charge. Note:- GI earth strip beyond 7.5M shall be measured and paid separately Note:-(i)Earth pit is required to be identified by Earth board. Earth Board Details are as under 1. EARTH PIT NO : EQ/ PS/ XXX 2. DATE OF MEASUREMENT : ................... 3. NEXT DUE DATE : ................... 4. STANDARD VALUE : ................... 5. VALUE OBTAINED : ...................... 6. MEASURED BY : ....................... 7. SUPERVISED BY : ........................
Material and Labour for Maintenance free Earthing, each pit consisting of copper coated steel rod of size 17.2mm dia 3 mtrs long 250 Microns molecularly bonded, joined with connecting clamps filled with maintenance free earth enhancing compounds Curec+ 6 kgs & Curecon 10 kgs, compounds strictly be a Eco friendly and must comply to IEEE 80:2000 clause 14.5 (d), IEEE 80:2000 clause 14.5 (b) and this compound should be Electrically & Thermally conductive, must be tested for Long term in CPRI for at least 2 year to display its stability & compound must be ISO certified and the earth pit should be closed with high density polymer HDPE inspection pit of 308 X 308 X 214 mm depth Complete all as specified and as directed. Note:-(i)Earth pit is required to be identified by the specific marker, colour codes (a) Maint free earthing pits- Red colour and write proper earthing details all as directed by Engr-in-charge. (ii) Earth resistance value shall be 1.0 Ohms. (iii) Blank (iv) 25 mm x 5 mm x300 mm copper bus bar - 1 No. (v) 25 mmx 5 mm x 150 mm bus bar - 1No (vi) Earth conductor beyond 7.5 Mts shall be measured and paid separately under relevant items of this schedule.Note :- Earth Board Details are as under 1. EARTH PIT NO : EQ/ PS/ XXX 2. DATE OF MEASUREMENT : ................... 3. NEXT DUE DATE : ................... 4. STANDARD VALUE : ................... 5. VALUE OBTAINED : ...................... 6. MEASURED BY : ....................... 7. SUPERVISED BY : ........................
Material and labour for test point termianal block made of gun metal or phosphours bronze size 75 x 75 x25mm drilled and screwed including 3 Nos 8 mm dia 25mm long hex head screw including sutiable enclosure all as specified and directed
Material and labour for Cutting chases in brick walls for concealed conduit wiring, ,not exc 10 cm girth , pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc,and making good complete all as specified and as directed .
Material and labour for G.I. tubing light grade of size 50mm bore for protection of cables to be laid under roads, crossings/culverts including taking down/up old unserviceable GI tubing complete all as specified and as directed Make: TATA pipes/Jindal / Appllo/Swastic.
PRAGATHI BUILDERS
Shanthi Construction
K. VENKATESH NAIDU
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .