Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.8 CrAccepted-AOC 4 195 38 PARAMESHWARA NILAYA MARAKADA KUNJATHBAIL DAKSHINA KANNADA KARNATAKA 575014 UDYAM KR 11 0021217 | DAKSHINA KANNADA | KARNATAKA | 575014 | ₹15.8 Cr | L1 | Accepted-AOC BEING LOWEST |
| 2 | L2₹16.3 CrRejected-Finance | ₹16.3 Cr | L2 | Rejected-Finance NOT BEING L1 |
| 3 | L3₹18.5 CrRejected-Finance UNIT B2 AUTONAGAR VISAKHAPATNAM VISAKHAPATNAM ANDHRA PRADESH 530012 | VISAKHAPATANAM | ANDHRA PRADESH | 530012 | ₹18.5 Cr | L3 | Rejected-Finance NOT BEING L1 |
| 4 | L4₹21.3 CrRejected-Finance | ₹21.3 Cr | L4 | Rejected-Finance NOT BEING L1 |
Tender Value
Refer Docs
EMD Value
₹15 L
Closing Date
26 Nov 2021, 6:00 pmClosed
CHIEF ENGINEER CG GOA
HQ CE CG GOA 403806
PROVISION OF DEFICIENT TYPE II MARRIED ACCOMODATION AT NEW MANGALORE
2021_MES_481454_1
82013/E8
Open Tender
Civil Works
750 days
MANGALORE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹3,000
GE (I) (CG) GOA
₹15 L
Yes
21 Dec 2021
12 Oct 2021
29 Nov 2021
12 Oct 2021
26 Nov 2021
12 Nov 2021
Amount
SCHEDULE ‘A’ PART-I (BUILDING & STRUCTURE WORKS) Details of prepriced schedule is given in tender documents.
SCHEDULE "A" PART-II ( SITE CLEARENCE, EXCAVATION AND EARTH WORK ) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-III (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IV (INTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-V (ROAD/ PATH/ CULVERT/ HARDSTANDING) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VI (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VII (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VIII (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IX (EXTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-X (FIRE FIGHTING) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XI (LIGHTENING PROTECTION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XII (AVIATION OBSTRUCTION LIGHT) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XIII (TELEPHONE/ TV CONDUIT) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART -XIV (MISCELLANIOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' E ' signifies this fact only.
INTERNAL WATER SUPPLY S & F Two way bib tap 15 mm Make – Drizzel or equivalent
S & F Health faucet with wall hook Make Hindware Model No F160027 or equivalent.
M&L Gun-metal, globe or gate valves with iron wheel head screwed both ends for iron pipe and fixed of the following (a) 80mm dia
(b) 100mm dia
(c) 150mm dia
INTERNAL ELECTRIC SUPPLY: S & F modular type bell ding dong of 2 module size, conforming to IS: 8884- 1978 complete all as specified and directed.
S & F modular type 1 module TV socket complete all as specified and directed.
S & F BEE five star rated energy efficientn BLDC high-speed ceiling fan having 1200 mm blade sweep, air-flow not less than 210 CMM, operating voltage 220-240 V and frequency 50 Hz, including a downroad of suitable size and electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fan complete all as specified and directed.
S & F engery efficient non-metalic fresh air fan having blade sweep 250 mm, air delivery not less than 860 CMH, operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fresh-air fan complete all as specified and directed.
S & F engery efficient metalic exhaust fan having blade sweep 300 mm, air delivery not less than 900 CMH, operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fresh-air fan complete all as specified and directed.
S & F MCB for AC applications conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, biconnect IP 20 protected lower terminals and sliding shutters, etc. complete all as specified and directed by engineer-in-charge.Make: Schneider, Legrand, Havells 6 A, SP MCB, C- curve
16 A, SP MCB, C- curve
32 A, DP MCB, C- curve
S F RCBO 32A, 30mA, 230V, 50Hz, DP confirming to IS 12640 (Part-2): 2016, assembled for AC applications having front face indication for earth leakage fault, sliding shutters, IP 20 protected 35 sqmm terminals, colour coded on/off indication on dolly, integrated label holder..etc complete specified and direcetd
Supply, installation, testing and commissioning of factory made, CPRI type tested, indoor cubical compartmental type LT PANEL 1 of suitable size, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 43 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enamelled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete all as specified and directed by engineer-in-charge. The Panel shall comprise of the following:
[A] BUSBAR CHAMBER [i] 01 Set (3L + N) of copper busbar of rated capacity 400 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection [B] INCOMING [i] 300 A, 415 V, Ics = 100% Icu = 50 kA, 50 Hz FP MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and pre-alarm & Overload), etc. [ii] LED phase indicators (Red, Yellow, Blue)- 01 Set
(C] OUTGOING [i] 250 A, 415 V, Ics = 100% Icu = 50 kA, 50 Hz FP MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and pre-alarm & Overload), etc. [ii] 250 A, 415 V, Ics = 100% Icu = 50 kA, 50 Hz FP MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and pre-alarm & Overload), etc. [iii] 63 A, 415 V, Ics = 100% Icu = 50 kA, 50 Hz FP MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and pre-alarm & Overload), etc.
Supply, installation, testing and commissioning of factory made, CPRI type tested, indoor cubical compartmental type LT Panel 2 of suitable size, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 43 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enamelled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete all as specified and directed by engineer-in-charge. The Panel shall comprise of the following:
[A] BUSBAR CHAMBER [i] 01 Set (3L + N) of copper busbar of rated capacity 400 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection [B] INCOMING [i] 250 A, 415 V, Ics = 100% Icu = 50 kA, 50 Hz FP MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and pre-alarm & Overload), etc [ii] LED phase indicators (Red, Yellow, Blue)- 01 Set [C] OUTGOING [i] MCB SPN 10 Amp (2 Nos) [ii] MCB SPN 32 Amp (26 Nos) [iii] Tempered Proof Digital Energy Meter single Phase 0-40 Amp (24 Nos)
Supply, installation, testing and commissioning of factory made, CPRI type tested, indoor cubical compartmental type LT Panel 3&4 of suitable size, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 43 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enamelled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete all as specified and directed by engineer-in-charge. The Panel shall comprise of the following:
[A] BUSBAR CHAMBER [i] 01 Set (3L + N) of copper busbar of rated capacity 400 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection [B] INCOMING [i] 250 A, 415 V, Ics = 100% Icu = 50 kA, 50 Hz FP MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and pre-alarm & Overload), etc. [ii] LED phase indicators (Red, Yellow, Blue)- 01 Set [C] OUTGOING [i] MCB SPN 32 Amp (28 Nos) [ii] Tempered Proof Digital Energy Meter single Phase 0-40 Amp (30 Nos)
External Water Supply: Supply, install, test and commissioining pump set centrifugal monoblock three phase electric driven motor on AC 415 Volts of capacity 9.35 LPS at 50 Meter head, bronze impeller, C-40 shaft, RPM 3000 not less than 10 HP complete with starter ,"B" class insulation including PCC foundation, GI suction pipe of suitable size and foot valves, priming arrangement, pressure gauges etc complete. Make : Kirloskar Model No KDS 1030++ or equivalent.
Supply and fix Non return valve CI of size 80mm with bypass arrangement.
Supply and fix Non return valve CI of size 50mm with bypass arrangement.
M&L for PCC solid block masonery chamber (valve pits) built in CM 1:6 for sluice valve/ stop valves etc including necessary excavation and earth work in any type of soil/strata, fabrication of MS cover, angle iron frame ect all as specified and directed of the following internal dimensions 900x900x900 mm.
External Electric Supply: S & F 9 mtr hot dip galvanized octagonal pole as per IS2629-BSEN 100025/100027 bottom dia-155mm, top dia 70mm wall thickness-3mm base plate-240x240x16mm thick with inbuilt junction box , single arm bracket (dia42mmx2.6mm thk x 1mtr length) and foundation 'J' bolt sets-M20x 900 mm long complete with excavation, PCC foundation and other necessary work as directed by Engr-in-charge.
Construction of Block-in-course stone masonary well bonded plinth of size 2.2 x 2.2 x 2 Mtr height for installing Out door type Transformer 100 KVA by carryingout the following:- a) M&L Block-in-course stone masonary well bonded plinth built in cement mortar 1:4 b) M&L PCC 1:4:8 type C-2 using 40mm graded stone aggregate as in mass foundation c) M&L PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in flooring of foundation
Supply and fix New generation energy saving and environmental friendly long life LED 70 W street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device. Make : Havells/Philips/Crompton greaves .
Supply and fix Rubber mat of 1 mtr x 2 mtr x 19 mm
Design supply, install testing & commissioning 08 passengers lift, speed 1.5 metre/sec, lift with single speed motor 415 volts, 3 phase, AC 50 Hz supply conforming to IS-14665, suitable to serve G+09 upper floors with AC Variable Voltage & Variable Frequency drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (08 Nos,one each in car, Machine room less & near Ground floor landing door) complete all as specified.
Design supply, install testing & commissioning 13 passengers lift, speed 1.5 metre/sec, lift with single speed motor 415 volts, 3 phase, AC 50 Hz supply conforming to IS-14665, suitable to serve G+ 09 upper floors with AC Variable Voltage & Variable Frequency drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (13 Nos,one each in car, Machine room less & near Ground floor landing door) complete all as specified.
FIRE FIGHTING SYSTEM: Supply and fix sided LED signage with built in battery backup for 2 hrs, Make- Bajaj or equivalent, Cat No. BESL 03 LED SSD WBB Red 220209
Supply, installation, testing & commissioning of networkable 2 Loop Micro processor based 2 wire fault tolerant loop with optional redunadant network module ,each loop shall have the cpability of connecting 126 devices.The fire alarm control panel shall have built in degarde mode function.The panel should have inbuilt TCP/IP communication for Panel Program and Remote Monitoring option through LAN or WAN communication.The panel shall be able to give location of all fire and More Fire /fault and Isolation conditions of addressable units via the address codes.The panel shall have the capacity of storing upto 2000 events.Further, the panel must be able to automatically switch ON /OFF respective control module when ever any alarm is triggered. The panel should have inbuilt common Alarm, Fault and monitored sounder output. The panel shall have a 8x40 characters LCD display with resolution of 256 X 112 pixels, and analog output, external/inbuilt printer to log all fire or fault events complete in all respects.The Panel Should have protection caregory of IP30. Also the panel should have the option to operate in manned and unmanned mode.The Panel Shall have 99 Zones with Individual LED Indicators or with in the Loop mimic driver for 96 LED indicators.The panel shall have a built in power supply and battery charger along with maintenance free 24 AH, 2 x 12 volt SMF Lead acid batteries capable of running for a minimum of 24 hours with battery charger complete as required.and as per specifications and Duly Approved by EN54/LPCB/VDS/FM
4c x 1.5 sqmm PVC insulated , FRLS armoured and overall PVC sheathed cable , laid on wall / ceiling using GI clamps as required includung final termination on Reapeator Panel. Make :- Polycab
Aviation Light: Supply and fix aviation obstruction light 2x100W LED yellow painted die cast aluminium alloy housing,red coloured with polycarbonate dome and accessories (Make Bajaj Cat No. BJAOL 2 BC, lamp Type GLS2x100W BC)
S&F metal enclosure DB 3 module IP 20 complete with Timer switch, Power condactor,Control MCB DP 16 A etc complete. Make : Indoasian Model :TL 016AB0
Stand by supply: Diesel engine driven generating set with AMF PANEL panel 62.5 KVA with Air cooled engine of 83 BHP for 50 KW power generation @ RPM 1500, brushless frame with silencer and Canopy for sound less mode (sound level not exceeding level specified by central pollution control board) and all engine accessories such as self starter, alternator/dynamo and 50 kW/ 62.5 kVA electric alternator, 415 volts, 3 phase, 4 wire,50 Hz, Voltage Regulation ± 15, Insulation class H coupled to engine with suitable coupling and base frame on foundation as recommended by the manufacturer and consisting of other electrical components, fuel tank of capacity of not lesss than for 12 hour run with level indicator installed on suitable steel frame with PCC foundation as per manufacturers instructions, Power Command genset Controller, fuel pipes, Dual spin on fuel filter, Dry type Aircleaner, Shutt off coil with safeties for LLOP/HWT , fuel pipes , bar metre, hour meter , oil temperature gauges, ammeter, ignition switch, radiator with cooling fan, maintanance free battery battery 12 V including suitable size of copper cable leads with terminals, all mountings ,accessories and necessary foundation and AVM pads complete as per manufacurers recommendations and to the satisfaction of Engr in charge..MAKE: Engine- CUMMINS/ASHOK LEYLAND / KIRLOSKAR.
(A) PRIME MOVER :- Suitable for driving 50 KW/62.5 KVA alternator Air cooled battery staart diesel Engine of suitable capacity confirming of ISO 3046 / BS 5514 BSS 649 and fuel tank suitable for 12 hrs running capacity mounted on MS frame pedestal supported with anti-vibration mounting rated for continuous running capable of taking 10% over load for one hr in any 12 hrs operaton complete with the following standard accessories :- (B) ALTERNATOR : 50 KW/62.5 KVA at 0.8 PF Brushless self excited, self regulaed 3 phase 50 Hz 415 V 1500 RPM 4 wire screen protected drip proof free from simulation problems continuous rating confirming to BS 5000 complete with automatic voltage regulator O/P voltage regulated between +/- 1% or set voltage from no load to full load. (C) AUTOMATIC MAINS FAILURE PANEL :- AMF panel for 50 KW/62.5 KVA DG Set fabricated out of sheet steel factory made suitable for floor mounting hinged from panel for easy asessibility with suitable rated bus bar internal wiring and with provision for connecting incomming/outgoing leads with the folowing accessories :-
Earthing complete with galvanized iron earth plate electrode 600x600 x6.0mm thick buried directly in ground( earth pit not less than2.25 mtr deep below ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level ,connected to galvanized iron strip of size 32x6 mm as earthing lead by means of nuts and bolts check nuts and washers of galvanized iron connected to test point, GI tubing 40mm bore medium grade protection pipe, GI watering pipe 20mm bore medium grade with funnel and wire mesh, charcoal and salt,Ci cover with suitable handle,PCC pit 1:2:4 including earth work in any type of soil and connecting to earthing test point/panel and testig on completion all as shown on electrical plate No -3 of SSR 2009- Part 1.
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion
Telephone & TV sockets: S & F Modular TV Socket 1 module
S & F Modular Telephone Socket 1 module
SEWAGE DISPOSAL: M&L for PVC SWR Pipes single socketed in any length 160mm dia with rubber ring joints laid in trenches or in floors all as specified
M&L for PCC 1:3:6 Type C2 concrete bed to drain pipes using 40mm graded stone aggregate for 160 mm pipe including packing under and haunching against the sides of pipes laid and tested complete all as specified and directed
BAVA INFRASTRUCTURE DEVELOPERS PRIVATE LIMITED
GOPAL TEKNOCON PRIVATE LIMITED
Agarwal Jagdish Construction Company Pvt. Ltd.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid