| 1 | L1₹90.7 LAccepted-AOC 1 OPP NAGAR NIGAM KATNI MAIN ROAD KATNI MADHYA PRADESH 483501 | KATNI | MADHYA PRADESH | 483501 | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹1.0 Cr+₹11.4 L (12.5%)Rejected-Finance | L2 | Rejected-Finance Being not lowest tenderer | |
| 3 | L3₹1.1 Cr+₹24.2 L (26.7%)Rejected-Finance | L3 | Rejected-Finance Being not lowest tenderer |
Tender Value
₹80.5 L
EMD Value
₹1.5 L
Closing Date
17 May 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE(AF) Tughlakbad
HQ Commander Works Engineers Air Force, Tughlakabad PO Sangam Vihar New Delhi 110 080
MODERNISATION OF ENGINE TEST BED AT PRODUCTON WING (POWER PLANT) AT BRD AF AF STN TUGHLAKABAD UNDER GE (AF) TUGHLAKABAD
2022_MES_512329_3
83262/E8/token-78
Open Tender
Civil Works
Item Rate
270 days
Tughlakabad
As per NIT conditions
7 documents required · 7 mandatory
₹1,000
GE(AF) Tughlakabad
₹1.5 L
Yes
2 Aug 2022
25 Apr 2022
19 May 2022
25 Apr 2022
17 May 2022
2 May 2022
60 days
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft/loose soil complete all as specified and directed.
Excavating in post holes( or similar holes) each n exc 0.5 cum getting out, returning,filling in and ramming earth of broken rubble mixed with earth around in layers not exceeding 25 cm in soft/loose soil complete all as specified and directed.
M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed.
M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed.
M&L for brick work with subclass 'B' Bricks straight or curved on plan exe 6 mtr mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for 15 mm thick rendering in cement mortar 1:4 on fair faces of brick or concrete surfaces finisded even and smooth without using exatra cement complete all as specified and directed.
M&L for rendering 10 mm thick in cement mortar 1:6 finished even and smooth without using exatra cement as on brick work surfaces complete all as specified and directed.
Demolition of cement concrete is ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, using broken stone or boulders watered and rammed to a true surface complete all as specified and directed.
M&L for 100 mm thick plain cement concrete 1:4:8 type D-2, using 40mm graded stone aggregate as in floor complete all as specified and directed.
M&L for 100mm thick plain cement concrete1:2:4 type B-1, using 20mm graded stone aggregate as in floor finished smooth with out using extra cement complete all as specified and directed.
Taking down chowkats or frame with shutter (without taking out shutter from the frame) exceeding 1.50 sqm and n exc 4.00 sqm each and removal from site complete all as specified and directed
M&L for anodised aluminium frame (having minimum 50 micron powder coating) for partitian frame work, doors, windows, ventilators with one or more rebates including cleat for fixing etc. complete all as specified and directed.
M&L for aluminium powder coated of any colour (thickness or powder coating not less than 50micron) doors shutters aluminium saction weighing 0.55 kg/sqm including necessary jointing cleats, glazing clips, rubber neoprene packing, handles two Nos in each door, hinges, anodised aluminium snap beading, screws complete all as specified and directed.
M&L for anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.). hinges type B-21 100mm long (2 No.) suitable handle (1 No.) fixed complete all as specified and directed.
M&L for aluminum anodized Deko grill MG 104(100mmx105mm) including necessry FUH channel joint cleats screws etc complete all as specified and directed.
S&F 12mm thick prelaminatd particle board, interior grade, prelaminated both side side with decorative choice lamination fixed with screws to timber/aluminium frame work complete all as specified and directed.
S&F door closer hydraulically regulated, designation No 3, universal type,Aluminium (extruded section body) suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80kg and fixed complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
M&L for steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 complete all as specified and directed.
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut , exc 22.5cm and n exc 30cm long dia of shank 16 to 20mm complete all as specified and directed.
S&F 12 mm thick gypsum board as in ceiling/walling fixed in anodised aluminium snap grid frame work for false ceiling of size of grid 605 x 605mm, with hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs/truss by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
M&L for vitrified ceramic dark shade tiles 10 mm thick (square/rectangular) polished , area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
M&L for glazed ceramic coloured tiles on vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match in walls etc over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed.
M&L for preparing new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
S&F framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290, Gde E 165 complete all as specified and directed.
M&L for TMT steel bars 10mm dia and over cut to length bent to shape reqd. incluing cranking, bending and binding with ms wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for TMTsteel bars 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders cut to length bent to shape reqd. incluing cranking, bending and binding with ms wire (annealed) not less than 0.9mm dia or securing with clips complete all as spcefied and directed.
M&L for formwork for flat surfaces to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, rough finished surface of concrete complete all as specified and directed.
M&L for formwork for flat surface to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and directed.
M&L for providing reinforced cement concrete 1:2:4 type B1 (nominal mix) using 20 mm graded stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
M&L for providing reinforced cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in chajjas and landing complete all as specified and directed.
M&L for preparation of newly plastered surface of wall and applying two coat of cement base paint complete all as specified and directed.
M&L for two coats of distemper oil emulsion to old surfaces of walls after complete removal of existing treatment including preparation of surfaces over 3mm thick wall care putty complete all as specified and directed.
M&L for rendering 5 mm thick in cement mortar 1:3 finished even and smooth as on concrete surfaces (with out using extra cement) complete all as specified and directed.
M&L for preparation of newly plaster surface of celling and applying three coats of white wash complete all as specified and directed.
S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates 410W(Gde-E-250)quality -A complete all as specified and directed.
S&F plate girder or single stanchions of grade 410W(Gde-E-250)quality -A, built up or one beam or channel section with flange plates consisting of ISMB or ISMB section, caps bases splices, angle bracket, cleats and other connections welded or fixed with screws, angle brackets, cleat and other connections welded or fixed with screws complete all as specified and directed.
Removing excavated material exc. 50 meter but n.exc. 250 meter complete all as specified and directed.
Returning filing in soft/loose soil including spreading, levelling ,watering and well rumming in layers not exceeding 25cm thick complete all as specified and directed.
Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in hard/dense soil and all as specified and directed
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and as directed
All as item No. 43 above but for each additional 1.5m or part thereof in depth beyound the first 1.5m and getting out in hard/dense soil all as specified and as directed
M&L for providing, precast cement concrete1:2:4 type B-1 (20mm graded stone agg) set in cement motar 1:4 as in cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces complete all as specified and directed.
M&L for cast iron work grade FG 150, unmachined, in brackets, gully traps, gratings, railing, frames,manhole covers, fire and soot doors, dampers, stop valve boxes, gate stops, parts of ranges, balusters and similar articles exc 5kg each complete all as specified and directed.
M&L for brickwork with subclass `B' bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1:4 complete all as specified and directed
M&L for brickwork with subclass `B' bricks, straight or curved on plan exc 6m mean radius, in half brick thick walls built in cement mortar 1:4 complete all as specified and directed.
M&L for RCC 1:2:4 type B-1, (nominal mix) using 20mm graded stone aggregate for slabs supported on walls, beams and column in floor canopies deck slab etc. complete all as specified and directed
M&L for rough finished flat formwork to soffits of suspended flat roof surface of slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) complete all as specified and directed
S&F framed work as in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe-410-W, Gde-E-250, quality 'B' complete all as specified and directed.
M&Lfor 15mm thick rendering in cement mortar 1:4 on fair faces of brick or concrete surfaces using water proofing compound complete all as specified and directed.
Supply only integral water proofing compound complete all as specified and directed.
M&L for 10mm thick rendering in cement mortar 1:4, on fair faces of brick or concrete surfaces complete all as specified and directed.
S&F PVC (SWR) 110mm dia pipes single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S&F PVC (SWR) 75mm dia pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S&F PVC (SWR) vent cowl of 75mm bore complete all as specified and directed.
M&L for PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in copings including necessary form work complete all as specified and directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc.complete all as specified and directed.
M&L for test benches modular type wleded, powder coated CRCA 2.5mm frame with modular front facia material, 03 rack mobile drawer, tube lighting inside the console, panel mountable pasolite lights for front work area illumination and minimum dimension 1500mm x 1500mm x 1000mm with AC mains power supply module including the following accessories complete all as per manufacturer instructions, specified and directed.:- (a) Rotary switch for on/off - 01 No (b) RCCB 40A rated current/30mA sensitivity - 01 No (c) Emergency push button -01 No (d) Main power on/off indication lamp red and green -01 set (e) Digital panel meter for voltage and current indication -01 No (f) 15/5A power socket 230 AC supply -02 Nos Make of Test Bench:- Fluke ICS model No Innovative-CAL-M-5025/ARCOM/Sensors India
M&L for power analyzer, 4 voltage+ 4 current + 01 motor channel, measure voltage, current, active power, reactive power, apparent power, power factor and harmonics with associated values, get accurate, precise results with 0.1% measurement accuracy, highly portable, battery powered analyzer weighing only 3.5 kg with upto 10 hours of battery life with logs data through software and can be reproted, 054 Nos current clamps conveniently measure current without having to disconnect the load 2000A, AC and DC current clamp maximum conductor size -52 mm maximum opening-81.5 mm complete all as per manufacturer instructions, specified and directed. Make:- Fluke model no 6004+ with 80i-2010s/ARCOM/Sensors India
M&L for pressure indicator/digital master gauge with PC interface and charging through USB port, pressure range 0 to 20 KG/cm2 with 0.02% FS USB powered, battery operated, PC interface complete all as per manufacturer instructions, specified and directed.. Make:- Fluke Model No 2700G-BG2M/ARCOM/Sensors India
M&L for Temperature probe/RTD (12" length) with temp range (-)200 degree C to 420 degree C + 0.04 to 0 degree C complete all as per manufacturer instructions, specified and directed. Make:- Fluke Model No 5627A-12-S with RTD compensation cable for 15-20mtrs 1 for oil temp and 1 for coolant temp/ARCOM/Sensors India
M&L for two channel temperature indicator measures with PRTs. RTDs. Thermistors and thermocouples resistance renge and accuracy from 0 ohms to 400 ohms + (.004% + 0.002 Ohms) complete all as per manufacturer instructions, specified and directed. Make:- Fluke Model No 1524-2562373-LPRT/ARCOM/Sensors India
M&L for software and desktop PC automatic interface with fluke master instruments datalogging,reporting and asset management complete all as per manufacturer instructions, specified and directed.:- Make:- Fluke ICS model no LCAL dell PC communication cable and accessories/ARCOM/Sensors India
S&F mild steel flexible exhaust pipe 4 inch dia (100mm) with flange fixing and with all fittings complete all as specified and directed.
S&F PP + FRP Wet Scrubber ( Double Stage Pack Bed ) Capacity :- 1200CFM , M.O.C. :- 3mm PPGL + 5mm FRP, Tank Size :- Ø1000mm x 1200mm Ht. M.O.C. :- 3mm PPGL + 5mm FRP ,Tower Size :- Ø600mm x 2400mm Ht. Air Inlet :- Ø300mm,Air Outlet :- Ø300mm' Drain Size :- 2" Over Flow Size :- 2" Packing Materials :- PP Pall Rings, three way/ 38mm x 38mm Interval,& Mist Eleminator. packing Height :- 1200mm, Pump :- 1 Hp , PP Pump, Pump Suction & :- 2", Delivery size :- 2", Scrubbing Media :- Alkaline Water Design Pressure :- Atmospheric, Operating Pressure :- Atmospheric, Design Temprature :- 60 °C, Operating Temprature :- 45 °C Flange Standard :- ANSI.16.5 CL-150# PP FRP Centrifugal Blower (Backword Curve) Motor :- 3 HP, 2880 RPM Motor Make :- Hindustan(NFLP)/KSB/Cromption Capacity :- 1800 CFM MOC :- 3mm PPGL + 5mm FRP Impeller :- FRVE, Drive :- Direct Drive, Pressure :- 200mm wc Make:- Ambalica FRP & Steel industries pvt ltd/Shivas projects pvt ltd/Green Genra tech pvt ltd
M&L for point wiring complete with 1.5 Sqmm (nominal area) PVC insulated, multi stranded, FRLS copper conductor cable unsheathed in and including PVC conduit with all fittings (concealed type) medium grade ISI Marked and PVC insulated FRLS copper conductor cable of size 1.5 sq mm as earth wire , connected to common earth dolly suitable for mounting modular switches complete all as specified and as directed for the folloiwing type of point wiring :- Note:- The works includes cutting of chases and making good disturbed surfaces and rate deemed to included in quoted rate.
One Light/Fan point controlled by one way switch
One 3 pin socket outlet point 5 Amp on same board.
One 3 pin socket outlet point 5 Amps on independent board.
All as per item No-68.03 above but One 3 pin socket out let 15 Amps on independent board with cables 4.0 Sqmm size and earth wire 4.0 sqmm.
M&L for sub main wiring with multistranded FRLS copper conductor cable PVC sheathed in and including concealed in brick wall/RCC as per the site condition, providing suitable PVC conduit with two runs of 4.0 Sqmm and 4.0 Sqmm FRLS copper conductor as earth wire and connected to earth dolly complete all as specified and directed. Note:- The work includes cutting of Chasis and making good the disturbed surfaces
M&L for modular socket outlet 6A, 2/3 pin combined 2 module complete all as specified and directed.
M&L for modular socket outlet 6A/16A, 2/3 pin combined 2 module complete all as specified and directed.
M&L for modular switch 1 way 6 Amps 1 module, suitable for 230 Volts Ac supply complete all as specified and directed.
M&L for modular switch 1 way 15/16 Amps 1 module, suitable for 230 Volts Ac supply complete all as specified and directed.
M&L for modular white cover plate with frame 3 module complete all as specified and directed.
M&Lfor modular white cover plate with frame 6 module complete all as specified and directed.
M&L for modular metal flush box 3 module complete all as specified and directed.
M&L for modular metal flush box for 6 module complete all as specified and directed.
M&L for ceiling rose 3 phase/PVC/ polycarbonate isolated body complete all as specified and directed.
S&F wall mounted LED batten 20 watt, 2000 lm in a compact batten (57.5 cm), decorative mushroom profile LED lighting fixture with extruded aluminium channel, environmental friendly, energy efficient & integrated electronic driver 230 Volt, AC, single phase, 50 Hz including all accessories prewired including making necessary electrical connection with 3 core copper coductor and testing complete all as specified and directed.
S&F for 2'x2' size LED panel lighting luminaire glare free illumination suitable for false ceiling Grid fitting size 595x595x70 mm (LXWXH) of 40 watts capacity recess mounting with high brightness SMD LEDs complete all as specified and directed.
M&L for distribution boards in sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB 240 Volts 20 Amps complete all as specified and directed.
M&L for MCCB sheet metal enclouser distribution board fabricated with CRCA sheet steel, powder coated included with insulated vertical phase bus bar, neutral bars and earth bars, cement spill protector and colour coded interconnecting wire set, cable ties, blanking plates of double door type suitable for housed 3/4 pole MCCB as incomer and SP/TP MCBs as outgoing, IP 43, metal door type, TPN 12 way, complete with MCCB 4 pole, 415 Volts, fixed type, 125 Amps with breaking capacity 16 KA complete fixed to MCCB DB enclouser and DB to be fixed with walls concelead type complete all as specified and directed.
M&L for MCB TPN 63 Amp, 16KA breaking complete all as specified and directed.
M&L for MCB 240 volts SP 6- 32 Amp 'C' curve 10KA breaking, capacity, ISI marked, complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI strip 25x4 mm main earthing lead by means of galvanized bolts, nuts and washers all as shown in electrical plate no 3 with connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt all around earth plate, test point of phosphorous bronze / gun metal of size 75 mmx 75 mm x25 mm, PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded black trap/granite/Basalt stone aggregate) 40mm thick cover reinforced with 8mm dia TMT bars 3 Nos both way with 12mm dia round bar handle, GI light grade watering pipe 20 mm dia with funnel and wire mesh, and 40 mm dia GI light grade earth lead protection pipe complete all as specified and directed. NOTE :- Earth lead and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth strip/protection pipe etc.
Supply and laying ground pass through wall and on wall connect test and commissioning the following XLPE LT armoured heavy duty electrical cable with aluminum conductor 1100 V grade of cross sectional area of the following size complete all as specified and directed.
LT UG Cable 3.5 C 70 Sqmm
LT UG Cable 4 C 25 Sqmm
M&L for sand cushioning in trenches for protection of LT under ground cable including watering and consolidation complete all as specified and directed.
Supply and laying well burnt sub class ‘B’ bricks, locally available in trenches for protection of underground cable complete all as specified and directed.
M&L in replacement of galvanised pipe of dia 50 mm, 'light grade' with all fitting,laid in trenches for passing of cable etc complete all as specified and directed.
Supply, installation, commissioing and testing wall split units indoor/ outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity with 410a refrigerant, 1.5 Ton capacity complete , comprising of the following :- (a) Room evaporaive indoor unit with speed blower fan of appropriate capacity including PCB, thermostatic control, air filter and drain for condensing water. (b) Out door condensing unit of capacity 18000BTU/Hr capacity with condenser fan motor of appropriate capacity - 01 No air cooled condenser pf 1.5 TR capaicty - 01 No shall be installed out side the building on and including suitable factory made mild steel brackets fixed on wall using fastners for fixing and installation of AC's. (c) Refrigerant copper pipe of suction and discharge line with insulation, condensing water drain pipe & protected by suuitable size of flexzible PVC conduit with control valves & safety accessories including control wiring for evaporator & condensing unit with suitable size of copper cable shall be fixed. (d) Making good the distrubed surface to match the existing surface after pluging the holes etc. Note : (i) Cutting holes in walls/window of any thickness for installation of AC etc connection and making good the distrubed surface to match with the thickness for installation of AC etc, connection and unit rate quoted by contractor shall deemed to be inclusive of this aspect. (ii) Electrical cable of required size & length to connect outdoor unit with indoor unit and indoor unit to viltage stablizer is deemed to be included in the quoted rates of contractor. (iii) Copper piping/with insulations and drain piping shall be also deemed to be inclusive in quoted unit rate. MAKE- Blue Star ICU518EBTU/Carrier/Hitachi RSOG518HDEA/LG/Voltas 4503108-185VD22
S&F voltage stablizer for automatic operation, single phase, naturally air cooled, indoor type, Copper wound, high low cut, time delay relay & designed for input variation between 170 V to 280 V with output voltage stabilized at 230 V with accuracy + 2.5% and of capacity 4 KVA completed all as specified and directed.
Balaji Constructions
A B K Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .