Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹14.0 L+₹12,996 (0.94%)Rejected-AOC BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | L2 | Rejected-AOC Being not L1 Bidder | |
| 3 | L3₹14.1 L+₹26,496 (1.91%)Rejected-AOC G 58 KIRAN GARDEN UTTAM NAGAR NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L3 | Rejected-AOC Being not L1 Bidder | |
| 4 | L4₹15.7 L+₹1.9 L (13.4%)Rejected-AOC M S 4BC PITAMPURA DELHI 110034 | DELHI | NORTH WEST DELHI | DELHI | 110034 | L4 | Rejected-AOC Being not L1 Bidder |
Tender Value
₹17.6 L
EMD Value
₹35,300
Closing Date
1 Sept 2020, 6:00 pmClosed
GE U WATER SUPPLY DELHI CANTT 10
GE U WATER SUPPLY DELHI CANTT 10
REPAIR MAINTENANCE OF SUBMERSIBLE PUMP SETS AND CONNECTED WORKS IN THE AREA OF AGE U WATER SUPPLY NO III UNDER GE U WATER SUPPLY DELHI CANTT 10
2020_MES_366396_1
GE/WS/D-58 OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
GE U WATER SUPPLY DELHI CANTT 10
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE U Water Supply Delhi Cantt 10
₹35,300
Yes
2 Nov 2020
4 Aug 2020
3 Sept 2020
4 Aug 2020
1 Sept 2020
18 Aug 2020
Amount
Disconnecting of electric connections from LT control panel and starter of submersible pump set of size 5 to 15 HP ,removing the pipe line connections from discharge side and taking down/out submersible pump set along with column pipe from bore well with the help of chain pully block including transportation to workshop for repairs and back , lowering the pump in bore well after repair and replacement of rusted nuts, bolts, washers, rubber gasket etc including testing complete all as specified and as directed .
Opening the submersible pump set of capacity 5 to 15 HP , taking down/out the burnt winding wire , cleaning the slots including rewinding the pump set with super enamelled copper winding wire of existing gauge ,weight etc. including all other insulating material complete all as specified and as directed. Note:- Copper winding wire of appropriate gauge shall be measured and paid separetely
Supplying and winding super enamelled copper winding wire of appropriate gauge suitable for 5 to 15 HP capacity submersible pump sets complete all as specified and as directed.
Supply Only following spare parts for submersible pump set of 5 to 15 HP capacity complete all as specified and as directed. NOTE :- (i) All the submersible pumps are type V6. (ii) If the contractor fails to repair the motor and pump within the seven days the same will be got repaired through other agency by calling spot quotation at his risk and cost. This shall be in addition to penalty as mentioned in clause 7.1 of Particular Specification. The decision of the Accepting officer in this regard shall be final concluding and binding on the contractor.
GM bush
SS Rotor Sleeve
Water seal and cable seal
Thrust bearing
Revolving Disc
CI Connection piece
GM Sand Guard
Sealing Ring
CI upper Housing
CI lower Housing
Flange upper with stud and nut
Flange lower with stud and nut
Seal bush
Motor Base
Thrust plate
stainless steel coupling with key
key for coupling
stud and nuts for connection piece
T Bolt with Nut
submersible cable joint
wire mesh
CI Suction Chamber
CI Stage bowl
GM Impeller
EPV Impeller
EPV Stage Bowl
Guide Bush
GM DOWL Bush
SS DOWL Sleeve
Inter ring
CI DOWL Piece
CI NRV body
Impeller key
SS pump shaft single stage
pump sand guard
SS Distance Sleeve
pump shaft key for stage
pump jacket single stage
hook bolt with nut
GM Neck Ring
stainless steel stud with nut
drain plug
Labour Only for following items of submersible pump set of 5 to 15 HP capacity complete all as specified and as directed. NOTE :- (i) All the submersible pumps are type V6. (ii) If the contractor fails to repair the motor and pump within the seven days given to him the same will be got repaired through other agency by calling spot quotation at his risk and cost. This shall be in addition to penalty as mentioned in clause 7.1 of Particular Specification. The decision of the Accepting officer in this regard shall be final concluding and binding on the contractor.
Rotor end repairing and key way
Remetling of Rotor, turning and balancing
Repairing of stator stamping
rotor balancing and epoxy painting
remetling of GM impeller & turning
Preperation to existing submersible pump set of capacity 5 to 15 HP and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed .
Supply and fixing in replacement GI Nipple with flange welded, heavy duty 40 x 300 mm size complete all as specified and as directed.
Supply and fixing in replacement GI Nipple with flange welded, heavy duty 50 x 300 mm size complete all as specified and as directed.
Supply and fixing in replacement GI Nipple with flange welded, heavy duty 80 x 300 mm size complete all as specified and as directed.
Supply and fixing in replacement GI column pipe, heavy grade, class 'C', 50 mm bore of 3 metre length, heavy duty, flange welded on both ends complete all as specified and as directed .
Supply and fixing in replacement GI column pipe, heavy grade, class 'C', 80 mm bore of 3 metre length, heavy duty, flange welded on both ends complete all as specified and as directed .
Supply and fixing in replacement submersible copper cable of size 2.5 Sq mm 3 core, 1100 Volts complete all as specified and as directed .
Supply and fixing in replacement submersible copper cable of size 4.0 Sq mm 3 core, 1100 Volts complete all as specified and as directed .
Supply and fixing in replacement submersible copper cable of size 6.0 Sq mm 3 core, 1100 Volts complete all as specified and as directed .
Supply and fixing in replacement moulded case circuit breakers, 3 pole, 63 Amps with breaking capcity 10 KA , 415 volts, type DU-100 complete all as specified and as directed. Make :- L&T or Equivalent in Siemens /ABB/ HAVELL'S .
Supply and fixing in replacement moulded case circuit breakers, 3 pole,100 Amps with breaking capcity 10 KA , 415 volts, type DU-100 complete all as specified and as directed. Make :- L&T or Equivalent in Siemens /ABB/ HAVELL'S .
Supply and fixing in replacement 3 pole power contactor ML-1.5, 25 Amps suitable for fixing in existing panel complete all as specified and as directed.
Supply and fixing in replacement 3 pole power contactor ML-2, 32 Amps, 415 Volts, 50 HZ suitable for fixing in existing panel complete all as specified and as directed.
Supply and fixing in replacement 3 pole power contactor ML-3, 40 Amps suitable for fixing in existing panel complete all as specified and as directed.
Supply and fixing in replacement 3 pole power contactor ML-4, 70 Amps, 415 Volts, 50 HZ suitable for fixing in existing panel complete all as specified and as directed.
Supply and fixing in replacement 3 pole power contactor ML-12, 120 Amps, 415 Volts, 50 HZ suitable for fixing in existing panel complete all as specified and as directed.
Supply and fixing in replacement 3 pole power contactor MNX-18, 32 Amps, 415 Volts, 50 HZ suitable for fixing in existing panel complete all as specified and as directed.
Supply and fixing in replacement 3 pole power contactor MNX-25, 45 Amps, 415 Volts, 50 HZ suitable for fixing in existing panel complete all as specified and as directed.
Supply and fixing in replacement 3 pole power contactor MNX-32, 55 Amps, 415 Volts, 50 HZ suitable for fixing in existing panel complete all as specified and as directed.
Supply and fixing in replacement thermal over load relay, type ML 1.5 relay, range upto 16 Amp complete all as specified and as directed.
Supply and fixing in replacement thermal over load relay, type ML 2/3 relay, range upto 42 Amp complete all as specified and as directed.
Supply and fixing in replacement thermal over load relay type MN2, relay range 6-10 Amp, complete all as specified and as directed.
Supply and fixing in replacement thermal over load relay type MN2, relay range 9-15 Amp, complete all as specified and as directed.
Supply and fixing in replacement thermal over load relay type MN2, relay range 14-23 Amp, complete all as specified and as directed.
Supply and fixing in replacement thermal over load relay type MN2, relay range 20-33 Amp, complete all as specified and as directed.
Supply and fixing in replacement fully automatic star-delta starter in sheet enclosure type ML-1.5, FASD, relay max range 13-21 Amp complete all as specified and as directed.
Supply and fixing in replacement fully automatic star-delta starter in sheet enclosure type ML-2 , FASD, relay max range 20-32 Amp complete all as specified and as directed.
Supply and fixing in replacement fully automatic star-delta starter in sheet enclosure type ML-3 , FASD, relay max range 28-42 Amp complete all as specified and as directed.
Supply and fixing in replacement single phase preventor, type VSP-II complete all as specified and as directed.
Supply and fixing in replacement Amp Meter 0 to 100 Amp of size 96 mm x 96 mm, analog type complete all as specified and as directed.
Supply and fixing in replacement Volt meter 0 to 500 Volts of size 96 x 96 mm, analog type complete all as specified and as directed.
Supply and fixing in replacement Amp Meter 0 to 100 Amp of size 96 mm x 96 mm, digital type complete all as specified and as directed.
Supply and fixing in replacement Volt meter 0 to 500 Volts of size 96 x 96 mm, digital type complete all as specified and as directed.
Supply and fixing in replacement phase Indicating lamp RYG, LED type assembly complete all as specified and as directed .
Supply and fixing in replacement Analog Timer complete all as specified and as directed. Make :- L&T/C&S or equivalent.
Supply and fixing in replacement Change over switch Upto 250Amps, 4 Pole with enclosures.
Supply and fixing in replacement Automatic Phase sequence corrector having Capacity 20-30 HP, Automatically correct Input supply reverse phase also protections against single phasing voltage unbalancing and low & high voltage within 3 to 5 seconds. Make :- SECO or equivalent.
An amount of Rs 85245.00 shall be deducted from BOQ on account of schedule of credit
Rahul Enterprises
Sumit Enterprises
Friends fire Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .