Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.7 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED BEING LOWEST BIDDER | |
| 2 | L2₹10.9 L+₹5,830 (0.54%)Rejected-Finance HOUSE NO 206 GAIKWAD ALI NEAR DATTA CHOWK MUNDHWA PUNE 411036 | PUNE | MAHARASHTRA | 411036 | L2 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER | |
| 3 | L3₹11.9 L+₹1.1 L (10.5%)Rejected-Finance | L3 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER | |
| 4 | L4₹12.0 L+₹1.2 L (11.1%)Rejected-Finance | L4 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER |
Tender Value
₹14.2 L
EMD Value
₹28,420
Closing Date
22 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE KHADKI
Headquarters CWE Khadki, Military Engineer Services, Range Hills Road, Khadki, Pune-411003
RENOVATION OF RECREATION HALL AND LECTURE HALL OF SQAE AND PROVITION OF SAFETY RAILING IN FRONT OF SQAE (A) HALL KHADKI AND RENOVATION OF LECTURE HALL IN IS/42 OF SQAE (A) KHADKI , PUNE UNDER UNDER GE (CENTRAL) KHADKI
2024_MES_661628_1
CWE/KKE/TOKEN-124 OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
KHADKI
AS PER TENDER
6 documents required · 6 mandatory
₹500
Yes
GE CENTRAL KHADKI
₹28,420
Yes
17 Dec 2024
24 Jun 2024
25 Jul 2024
24 Jun 2024
22 Jul 2024
9 Jul 2024
25 Jun 2024 - 1 Jul 2024
Amount
B/R PORTION Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings/wall cladding/ridge etccomplete all as specified and directed by Engineer-in-Charge
S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge
S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall/Ridge fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge
M & L for vitrified tiles light shade 10mm thick (square/rectangular) polished area of each tile n. exc 0.36 sqm in floor over and including 15mm thick screed bed or bedding layer in CM 1:6 for laying floor finishes, set and jointed in neat cement slurry and pointed in white or coloured cement to match including dismantling and removing the debris outside the defence land complete all as specified and directed by Engineer-in-Charge
All as per Ser item No 04 but in skirting and dado laid over and incl 10mm thick rendering in CM 1:4 and pointing including dismantiling and removing the debris outside the defence land complete all as specified and directed by Engineer-in-Charge
M & L for cement concrete 25mm thick type B-0, 1:2:4 (12.5mm graded aggregate) as in flooring complete all as specified and directed by Engineer-in-Charge
M & L for 15mm thick Rendering on brick /concrete or dubbed surface in CM 1:4 on wall with water profing compound finishing even & smooth without using extra cement and similar like at any height including necessary scaffolding , ladder & formwork including taking down cement plaster, raking out joints, hacking for key & scrubbing down with water and removing the debris outside defence land complete all as specifed and as directed. (Note : water proofing compound shall be measured & paid separetely)
Supply only Liquid water proofing compound complete all as specifed and as directed.
M & L for 15mm thick Rendering on brick /concrete or dubbed surface in CM 1:6 on wall with water profing compound finishing even & smooth without using extra cement and similar like at any height including necessary scaffolding , ladder & formwork including taking down cement plaster, raking out joints, hacking for key & scrubbing down with water and removing the debris outside defence land complete all as specifed and as directed. (Note : water proofing compound shall be measured & paid separetely)
M & L for preparing new plastered surface of walls and applying two coat of cement base paint over a coat of alkali resistant primer at any height including necessary scaffolding ladder etc complete all as specified and directed by Engineer-in-Charge
M & L preparation of New plastered wall surfaces and applying 3mm thick wall care putty to get smooth and even surfaces as directed and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and directed by Engineer-in-Charge
M & L for preparation of old plastered /concrete surface of ceiling and applying two coats of oil bound distemper emulsion, white or tinted upto height 10mtr including 1mm thick birla white putty over a coat of primer (where as required ) necessary scaffolding etc complete all as specified and directed by Engineer-in-Charge
M & L for preparation of old painted steel surface of any description, not otherwise described over 10cm width or girth and applying two coat of synthetic enamel paint complete all as specified and as directed
Taking down chowkhat or frame n. exc 1.5 Sqm each but with shutter (without taking off shutter from the frame) complete all as specified and directed by Engineer-in-Charge
Taking down chowkhat or frame exc. 1.5 Sqm but n. exc 4 Sqm each but with shutter (without taking off shutter from the frame) complete all as specified and directed by Engineer-in-Charge
S & F aluminium powder coated window sliding type (3 track) with frame size 100x35x1.2mm thick and shutter frame size 39.40x17.70x1.2mm thick with and including two glass shutter and one mesh shutter including necessary jointing cleats, glazing clips, rubber packing, powder coated aluminium snap beading screws with and including 5mm thick tinted float glass and 0.36mm dia apperture 1.4mm SS wire mesh and fittings etc complete all as specified and directed by Engineer-in-Charge
S & F Pressed steel frames of size 105x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, tarring back of chowkhats & holdfast etc, complete all as specified and directed by Engineer-in-Charge
S & F for 30mm thick flush shutter, solid core construction, with block board core plywood face panels, commercial type on both sides, chemically treated against termite infestation, complete all as specified and directed by Engineer-in-Charge
M & L for providing cement concrete type B1 (1:3:6) (using 12.5mm graded aggregate) as in pressed steel door frame (backfil),complete all as specified and directed by Engineer-in-Charge
M & L for providing cement concrete type C-1 (1:3:6) (using 20mm graded aggregate) as in hold fast, complete all as specified and directed by Engineer-in-Charge
M & L for preparation of new or previously untreated wooden surface of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer-in-Charge including
S & F Extruded brass handles, fabricated type polished 150mm long fixing with screws etc complete all as specified and directed by Engineer-in-Charge
S & F Aluminium alloy, anodised, sliding door bolt 300mm long, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy 12mm dia, complete all as specified and directed by Engineer-in-Charge
S & F Aluminium anodised, barrel tower bolt 200mm long, powder coated of extruded section and fixed complete all as specified and directed by Engineer-in-Charge
S & F for Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290,Gde-E-165 etc complete all as specified and directed by Engineer-in-Charge including
S & F 140mm size floor door stopper of aluminium alloy body and tongue, inodised, with hard drawn steel spring, fixed in floor for aluminium/wooden door, complete all as specified and directed by Engineer-in-Charge
M & L for Granite 20mm thick work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms, vertical surface of wall also and like in 12mm thick screed bed or bedding layer cement mortar (1:3) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by Engineer-in-Charge
S & F Harrison rails, anodised aluminium alloy with fixing brackets, stops, rollers etc complete all as specified and directed by Engineer-in-Charge
Dismantling of wall and ceiling boards (fibre, pulp, insulation,PVC Panelling etc) or insulation boards/slabs/blankets, any thickness, including cover fillets.complete all as specified and directed by Engineer-in-Charge
S&F for E-board 'Everest' make 600x600x4mm thick white prelaminated sett embosed reinforced designer ceiling board tiles of approved texture at any height laid on hot dipped galvanised iron imposed grid with 24mm wide T-section exposed flanges which shall be powder coated white. The frame work shall comprise of main runner made from 0.33mm thick GS sheet and of size 24x32x3000mm and spaced at 1200mm centers securely fixed to the structural soffits by approved hangers at 1200mm maximum centers, hangers of GI wire 4mm dia to be fixed by approved rawl plug, level and justers and screws etc., the last hanger at the end of each main runner shall not be greater than 450mm from adjacent wall, flush fitting of 1200mm long cross tee (with double stitching) to be interlocked between main runners at 600mm center to form 1200x600mm modules cross tee longer than 600mm to be supported independently. 600x600mm modules to be formed by fitting 600mm long cross Tee centrally between the 1200mm cross tee. Tee, Perimeter wall angle shall be of 0.45mm thick GS sheet of size 19x19mm and 300mm long of white colour all as per manufacture instructions, complete all as specified and directed by Engineer-in-Charge including
Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc 15cm thickness (below of above ground level) and removing the debris outside the defence land complete all as specified and directed by Engineer-in-Charge including
M & L for 100 mm thick plain cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as in sub base complete all as specified and directed by Engineer-in-Charge
M & L for 75mm thick plain cement concrete (1:3:6) type C-2, (using 40mm graded stone aggregate) finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge
M&L for Rubber moulded coloured glossy finish (Red, Yellow & Black) precast concrete interlocking paver blocks with grey cement and pigment any shape and size, shade as approved by GE, 60mm thick conforming to IS 15658-2006 M-35 grade and interstices filled with sand including 40mm thick sand cushion and including demolition of existing tiles and removal outside the MoD land complete all as specified and directed by Engineer-in-Charge
M & L for Stainless steeel railing of height of 1.1m with top rail pipe 50mm bore (16 gauge), verticle pipe 30mm bore 16 gauge at the 1.0 m c/c and to longitudinal paralel pipe of size 20mm bore (16 gauge ) incl T cross bend base coupling fixed with necessary fasteners for anchoring in floor and walls etc complete all as specified and directed by Engineer-in-Charge
E/M PORTION Taking down carefully copper/aluminium point wiring (light /fan , socket or power) complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc and making good disturbed surfaces of walls, floors etc to match with existing surfaces complete all as specified and directed by Engineer-in-Charge .
Taking down MCBs with sheet metal enclosure, main switch, DB etc and making good disturbed surfaces to match with existing surfaces complete all as specified and directed by Engineer-in-Charge .
Taking down sub main wiring of any size/capacity complete all as specified and making good disturbed surfaces to match with the existing surfaces complete all as specified and directed by Engineer-in-Charge
M&L for point wiring 1100 volt grade single core PVC and unsheathed FRLSH cable with multistranded copper conductor 1.5 sq.mm drawn in and including medium grade PVC Casing caping with all accessories like bends, Tees, Crosses etc on surface of wall/ceiling including PVC insulated unsheathed earth wire with copper conductor of size 1.5 sq.mm & to be terminated in PVC gang boxes suitable for modular fittings complete all as specified and making good disturbed surfaces for:-
a) One Light point controlled by one, one way switch.complete all as specified and directed by Engineer-in-Charge
b) One ceiling/exhaust fan point controlled by one switch and regulator complete all as specified and directed by Engineer-in-Charge including
c) One 5 pin socket outlet, 6 Amp 230 V on the same board with other switches complete all as specified and directed by Engineer-in-Charge
d) One 5 pin 6 amps socket outlet point on independent board for wall mounted fan point complete all as specified and directed by Engineer-in-Charge
All as per item Sl. No. 39 above but wiring with 2.5 sq.mm multistranded cable and earth wire with copper conductor of size 2.5 sq.mm for 15 amps power point.complete all as specified and directed by Engineer-in-Charge
S&F for Piano switch one way 6 Amp 230v AC complete all as specified and directed by Engineer-in-Charge
S&F for r socket 2 in 1, 5 pin 6 amp 240 volts AC complete all as specified and directed by Engineer-in-Charge
S&F for socket 2 in 1, 6 pin 16 amp 240 volts AC complete all as specified and directed by Engineer-in-Charge
S&F for switch 16 amps 240 volts, one way complete all as specified and directed by Engineer-in-Charge
S&F for ceiling rose surface PVC/Polycarbonate two to three terminals/plate complete all as specified and directed by Engineer-in-Charge
S&F for step fan regulator electronic Step type suitable for 1200/1400mm sweep ceiling fan working on 230 volt AC complete all as specified and directed by Engineer-in-Charge
S&F for LED luminaire 600 mm x 600 mm (2x2), 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper Cable of suitable size complete all as specified and directed by Engineer-in-Charge
S&F for LED bldg light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engineer-in-Charge
M& Lr for Sub Main Wiring with two run single core 4 Sqmm PVC insulated unsheathed (FRLS) cable with stranded copper conductor drawn through and including PVC casing caping with 4 Sqmm copper green colour earth wire complete all as specified and directed by Engineer-in-Charge
S&F for MCB DB TPN 4 way double door for 415 volts with 200 Amps bus capacity including fixing arrangement complete all as specified and directed by Engineer-in-Charge
S&F for sheet metal enclosure DB single pole and neutral for 240 volts 8 way with 200 Amps rated busbar flush/surface mounting. Double door including wooden board complete all as specified and directed by Engineer-in-Charge
S&F for Isolator (MCB) TPN 63 amp 415 volt complete all as specified and directed by Engineer-in-Charge
S&F for Isolator (MCB) SPN 240 volt 40 amp 10KA complete all as specified and directed by Engineer-in-Charge
S&F for MCB single pole 240 volt 6 to 20 amps 10 KA complete all as specified and directed by Engineer-in-Charge
S&F for exhaust fan steel body, 450 mm sweep heavy duty, 230 volts including taking down and depositing to MES store complete all as specified and directed by Engineer-in-Charge
M&L for Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5mtrs below normal ground level connected with galvanized iron/steel earth wire of 4 mm dia by means of bolts, nuts, check nuts and washers made out of galvanized iron or steel all as shown in electrical plate No 3 of SSR Part-I and earth wire protected by galvanized pipe light grade 15mm bore and connected to DBs including necessary earthwork and excavation in any type of soil, GI light grade 20mm bore watering pipe with funnel and wire mesh, PCC 1:2:4 type B1 chamber with 40mm thick RCC 1:2:4 type B1 design mix cover slab with 6mm dia MS bars at 100mm c/c both ways with MS Hook 6mm dia MS bars etc testing complete all as specified and directed by Engineer-in-Charge
Taking down ceiling fan of any type 1200/1400 mm from its location and deposit to MES store complete all as specified and directed by Engineer-in-Charge
S&F for ceiling fan of 1200 mm sweep , 230 volts, AC, with suitable downrod and MS hook complete all as specified and directed by Engineer-in-Charge
S&F for LED lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engineer-in-Charge
S&F for wall mounting fan high performance, high efficiency,400mm sweep, 230 volts complete all as specified and directed by Engineer-in-Charge
AJINKYA VIKRAM GAIKWAD (BID ID -3055429)
AGREN ENTERPRISES (BID ID -3070836)
M/S JAYCONSTRUCTION CO (BID ID -3070509)
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .