Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.6 LAccepted-AOC | L1 | Accepted-AOC Awarded Being Lowest Bibber | |
| 2 | L2₹23.9 L+₹60,004 (2.57%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹26.0 L+₹2.7 L (11.4%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹27.9 L+₹4.6 L (19.8%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | Rejected-Technical | - | Rejected-Technical Residual Worl Load is more than twice the tendering limit |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
23 Jul 2021, 6:00 pmClosed
Garrison Engineer (N) Ahmednagar
Military Engineer Services Garrison Engineers (North) Nagar Pathardi Road Ahmednagar Fort Ahmednagar 414 002
Repairs / Replacement of Submercible Motors / Monoblock Pumps Cleaning and Periodical Services to overhead water tanks and Sluice valves Gate valves Float valves at various locations at ACCS area under GE(N) Ahmednagar
2021_MES_445801_1
8543 / E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE (N) Ahmednagar
Class D Cat a(ii)
8 documents required · 8 mandatory
₹500
Yes
Garrison Engineer North Ahmednagar
₹50,000
Yes
25 Aug 2021
26 May 2021
26 Jul 2021
26 May 2021
23 Jul 2021
9 Jun 2021
Amount
Excavation in trenches n' exc 1.5 m wide and n' exc 1.5 m in depth and n' exc 10 Sqm on plan and getting out in Soft / loose soil etc complete all as specified and directed by Engineer-in-Charge.
All as per serial item No 1 (here-in-before) but in Hard / dense soil
Returning, filling in excavated material (soil) including spreading, levelling, watering and well ramming in layers not exc 25 cm etc complete all as specified and directed by Engineer-in-Charge.
Removing excavated material to a distance n' exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point etc complete all as specified and directed by Engineer-in-Charge.
Taking up or down GI steel tubing and connections from trenches / walls / floors etc cleaning for re-fixing for 100 mm bore pipe etc complete all as specified and directed by Engineer-in-Charge.
All as per Sl item No 5 (here-in-before) but 80mm bore of pipe
All as per serial item No 05 (here-in-before) but 50 mm bore pipe
All as per serial item No 05 (here-in-before) but 40 mm bore pipe
All as per serial item No 05 (here-in-before) but 25mm bore pipe
All as per serial item No 05 (here-in-before) but 20 mm bore pipe
All as per serial item No 05 (here-in-before) but 15 mm bore pipe NOTE for item Nos 5 to 11 : Earth work & excavation shall be measured and paid separately & Earth work & excavation shall be manual or with mechanical equipments such as pockland, JCB etc, (i) The contractor/his supervisor will report the office of Engineer-in-Charge at 09.00 clock morning every day to collect the complaint slips from JE and will render the completion within 12 hours failing which Rs 500/- per day per complaint will be charged as an penalty & same will be recovered from contractor's due (ii). The contractor and his supervisor will provide the mobile number so that they can be communicated about the complaints, the SMS will be sent on those mobile and will be treated as an official complaints. The contractor will render the completion in writing to the Engineer-in-Charge within 12 hours hours failing which Rs 500/- per day per complaint charged as penalty to the contractor.
Supply and fix GI pipes, medium grade including necessary fittings such as sockets, elbows, tees, reducers, unions, nipples etc laid in trenches / walls / floors etc for the 100 bore pipe etc complete all as specified and directed by Engineer-in-Charge.
All as per serial item No 12 (here-in-before) but 80 mm bore pipe
All as per serial item No 12 (here-in-before) but 50 mm bore pipe
All as per serial item No 12 (here-in-before) but 40 mm bore pipe
All as per serial item No 12 (here-in-before) but 25mm bore pipe
All as per serial item No 12 (here-in-before) but 20 mm bore pipe
All as per serial item No 12 (here-in-before) but 15 mm bore pipe
All as per serial item No 12 (here-in-before) but using old retrieved pipe from srl item No 05 with new GI fittings.
All as per serial item No 13 (here-in-before) but using old retrieved pipe from srl item No 06 with new GI fittings.
All as per serial item No 14 (here-in-before) but using old retrieved pipe from srl item No 07 with new GI fittings.
All as per serial item No 15 (here-in-before) but using old retrieved pipe from srl item No 08 ,with new GI fittings.
All as per serial item No 16 (here-in-before) but using old retrieved pipe from srl item No 09,with new GI fittings.
All as per serial item No 17 (here-in-before) but using old retrieved pipe from srl item No 10 ,with new GI fittings.
All as per serial item No 18 (here-in-before) but using old retrieved pipe from srl item No 11 ,with new GI fittings. NOTE for item Nos 12 to 25 : Earth work & excavation has already been considered under srl item Nos 5 to 11. (i) The contractor/his supervisor will report the office of Engineer-in-Charge at 09.00 clock morning every day to collect the complaints from JE and will render the completion within 12 hours failing which rs 500/- per day per complaint will be charged as an penalty & the same will be recovered from contractors due. (ii). The contractor and his supervisor will provide the mobile number so that they can be communicated about the complaints, the SMS will be sent on those mobile and will be treated as an official complaints. The contractor will render the completion in writing to the Engineer-in-Charge within 12 hours hours failing which Rs 500/- per day per compaint charged as penalty from the contractor.
Repairs/rectification of GI Pipe leakage by replacing short piece length up to 0.50 mtr in wall/floors etc and excavation upto 1 cum as in trenches and including providing unions, reducers,nipples etc for 15 mm bore pipe and making necessary connections to make it functional etc complete all as specified and directed by Engineer-in-Charge.
All as per serial item No 26 (here-in-before) but 20 mm bore pipe
All as per serial item No 26 (here-in-before) but 25 mm bore pipe
All as per serial item No 26 (here-in-before) but 40 mm bore pipe
All as per serial item No 26 above but 50 mm bore pipe
Supply and fixing in replacement of unserviceable PVC insulated cable 3 Core 10 Sqmm, 1100 Volts grade, heavy duty, multistranded copper conductor for connecting motor to panel board with copper lugs duly encased through and including suitable size PVC pipe fixed to wall / laid in floors, Taking down/up unserviceable items included in Rate Quoted etc complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement Rubber packing 3mm/ 6mm thick suitable for flanged joints etc complete all as specified and directed by Engineer-in-Charge.,Taking down/up unserviceable items included in Rate Quoted.
Supply and fix in repairs cast iron sluice valve ,80 mm bore , Class PN1, ISI marked with stainless steel spindle, both ends flanged including rubber gasket, nuts, bolts and washers etc complete all as specified and directed by Engineer-in-Charge.
All as per serial item No 33 (here-i-before) but 100 mm bore pipe
All as per serial item No 33 (here-in-before) but 150 mm bore pipe
All as per serial item No 33 (here-in-before) but 200 mm bore pipe
All as per serial item No 33 (here-in-before) but 250 mm bore pipe
All as per serial item No 33 (here-in-before) but 300 mm bore pipe
Material and labour in replacement of run lead joints 150mm bore in old pipes/specials etc complete all as specified and directed by Engineer-in-Charge.
All as per item No 39 (here-in-before) but 200 mm bore
All as per item No 39 (here-in-before) but 250 mm bore
Supply & Fixing in replacement MCCB 63 Amp, 3 pole 50 Hz 415 Volts, with rupturing capacity 25 KA etc complete all as specified and directed by Engineer-in-Charge.,Taking down/up unserviceable items included in Rate Quoted.
All as per srl item No 42 above but 160 Amp, 4 pole 50 Hz 415 Volts, with rupturing capacity 25 KA.
All as per srl item No 42 above but 200 Amp 4 pole 50 Hz 415 Volts, with rupturing capacity 35 KA
Supply & Fixing in replacement pressure gauge of capacity 0-100 kg as per sample suitable fo 10 to 50 HP pump set etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of monoblock pump of 0.5 HP for removing of leakage water at wet well etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for gland packing of sluice valves 80 mm bore with proper size asbestos grafite gland packing rope etc complete all as specified and directed by Engineer-in-Charge.
All as per item No 47 (here-in-before) but 150mm dia
All as per item No 47 (here-in-before) but 200mm dia
All as per item No 47 (here-in-before) but 250mm dia
Supply and fixing in repair of PVC pipe of size 80mm for replacing of sewage collecting well air vent pipe with jallies etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs, non return valve, ISI marked confirming to relevent IS of size 150 mm etc complete all as specified and directed by Engineer-in-Charge.
All as per item No 52 (here-in-before) but 200mm dia
Repair/replacement of Iron coupling including rubber coupling as per site requirment as per etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for Servicing of motor and pump 12.5 HP, 3 Ph, 415 Volts, 50 Hz, pump set installed at KK Range. by disconnecting from pump/dealigning from pump taking out end covers ,cleaning of end covers, bearings, fan blade etc and greasing of bearings with best quality heavy duty grease ,reassembling and testing to the pump by taking out unserviceable gland packing , greasing to bearing and shaft of pump providing new gland packing including tightening of gland packing to stop leakage of water from gland , tightening of all nuts, bolts etc to ensure smooth functioning of pump refixing back motor to its original position or desired location, adjusting for proper alingment etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs Bearing for 12.5 HP motor/pump etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement Coupling nuts bolts of existing size shape and length for 30 / 12.5 HP motor etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of Star Coupling rubber bushes of existing Size / Shape for 30 / 12.5 HP pump sets etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for Repair of motor/ pump 12.5 HP, 3 Ph, 415 Volts by disconnecting of pipes, foundation, transporting to workshop, opening of pump, cleaning of parts, segregating unserviceable parts carrying out repairs / machining / winding / grinding / metalling works ,greasing, oiling ,reassembling including checking for smooth functioning ,transporting back to site, fixing on existing foundation, connecting with pipes and motor adjusting for proper alignment ensuring smooth functioning complete all as specified and as directed. pump set installed at KK Range by replacement of etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for Removal / taking up of submersible pump of any capacity from existing borewell depth up to 150 mtr by disconnecting of electric cable and delivery pipes etc and lowering pump along with pipe and cable on completion of repairs including connecting and testing etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for Repair of submerssible pump/motor up to 7.5 HP, 230/415 volts by transporting to civil work shop, opening, taking out old burnt out winding, preparing for re -winding with PVC insulated copper winding of suitable guage including all materials as required, re-assembling, testing at work shop, transporting back to site and connecting with pipe & electric supply after the pump is lowered and testing the pump for smooth functioning etc complete all as specified and directed by Engineer-in-Charge.
Supply, laying, connecting and testing in replacement flat PVC cable, water proof of size 3 Core, 4 Sq mm, 1100 Volts grade copper conductor, multi stranded for submersible/centrifugal pumps etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs nylon rope 20 mm dia of best quality etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement in line Pressure Booster pump of 0.3 to 0.5 HP, single phase etc complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of CI foot valves of size 300 mm flanged ends, lift type confirming to IS 4038 etc complete all as specified and directed by Engineer-in-Charge.
All as per item No 65 (here-in-before) but size of 80 mm at KK Range Pump house
Material and labour for applying two coat of synthetic enamel Painting to Cast iron water mains upto 200 mm dia of OH reservoir of height up to 20 metre etc complete all as specified and directed by Engineer-in-Charge.
Dewatering, cleaning of overhead reservoir with high pressure jet to remove all mossess , algea ,dirt ,diposits and other sediments ,scubbing of internal portions with wire brushand removal of dirt with sludge machines /industrieal vaccumc leaners and disposal of the same to a safe distance including sterlizing the complete internal surfaces of the tank by using ISI mark grade I bleaching powder /liquid chlorine, washing with fresh water drying up ,applying one coat of anti fungal cement paint on internal surfaces including marking /writing the words on external wall at visible place "Military Engineer Services ' Tank Capacity Date of cleaning " using synthetic enamel paint in white colour over back background and letters height 50mm and width 40mm etc complete all as specified and directed by Engineer-in-Charge for following capacities:- Note: Cleaning of the OHT's shall be done once in Every Six Months
(a) (i) OH Tank at New KLP 100000 Glns capacity (ii) OH Tank at BTR 100000 Glns capacity iii) OH Tank at New AC Depot 100000 Glns capacity (iv) OH Tank at Dhobi Ghat 100000 Glns capacity
(b) (i) OH Tank at New KLP 150000 Glns capacity (ii) OH Tank at Annex 150000 Glns capacity
(c) (i) OH Tank at queens Rd MAP Qtr 30000 Glns capacity (ii) OH Tank at New AC Record 30000 Glns capacity
(d) (i) OH Tank at MH DMR 120000 Glns capacity (ii) OH Tank at BTR 120000 Glns capacity (iii) OH Tank at Dhobi Ghat 120000 Glns capacity
(e) (i) OH Tank at Kiran Line 50000 Glns capacity (ii)OH Tank at Casstle Rd 50000 Glns capacity
(f) (i) OH Tank at Tarapore Enclave 100000 Ltrs capacity OH Tank at JK Road 100000 Ltrs capacity
(g) OH Tank at KK Range 5000 Glns capacity (h) OH Tank at EME WKsp 5000 Glns Capacity
(h) UG Sump at KK Range 10000 Glns capacity
S&F in repairs high pressure polythelene float valve with PVC ball suitale for fixing to GI pipe of 20 mm dia etc complete all as specified and diected by Engineer-in-Charge.
S& F in repairs high pressure polythelene float valve with PVC ball suitale for fixing to GI pipe of 25 mm dia etc complete all as specified and directed by Engineer-in-Charge.
S& F in repairs high pressure polythelene float valve with PVC ball suitale for fixing to GI pipe of 15 mm dia etc complete all as specified and directed by Engineer-in-Charge.
Material and labour in repairs gun metal gate valve/brass stop valve, high pressure both ends screwed down with crunch or butterfly handle with suitable size sockets on both ends nipples, unions, etc suitable for up to 50 mm bore GI pipe etc complete all as specified and directed by Engineer-in-Charge.
All as per serial item No 80 (here-in-before) but 40 mm bore pipe
All as per serial item No 80 (here-in-before) but 25 mm bore pipe
All as per serial item No 80 (here-in-before) but 20 mm bore pipe
All as per serial item No 80 (here-in-befoe) but 15 mm bore pipe
Material and labour for opening of unserviceable sluice valves, cleaning the serviceable parts, adjusting of moving parts , greasing , re-assembling of valve and fixing to the desired position with and including replacement of rubber gaskets, nuts ,bolts, washers , gland packing,Brass Checknuts and SS Spindle suitable for 80 mm bore valve etc complete all as specified and directed by Engineer-in-Charge.
All as per serial item No 85 (here-in-before) but 100 mm bore pipe
All as per serial item No 85 (herwe-in-before) but 150 mm bore pipe
All as per serial item No 85 9here-in-before) but 200 mm bore pipe
All as per serial item No 85 (here-in-before) but 250 mm bore pipe
All as per serial item No 85 (here-in-before) but 300 mm bore pipe
Material and labour for Removal / taking up of submersible pump of any capacity from existing borewell depth up to 150 mtr by disconnect of electric cable and delivery pipes etc and flushing the waste soil from borewell after that fixin the extra heavy grade GI/HDPE pipe of 50mm dia which is required and lowering pump along with pipe and cable on completion of repairs including connecting and testing etc complete all as specified and directed by Engineer-in-Charge. Note:- GI/HDPE pipe will be measured and paid seperately.
Supply and Lay HDPE pipe 6 kg/Sqcm pressure P-63 grade 50mm Bore with fitting heavy duty for fixing with submersible pump including clamps nuts and bolts GI fittings all as required as per site requirement etc complete all as specified and directed by Engineer-in-Charge.
An amount of Rs 73,900.00 shall be deducted from BOQ on account of schedule of credit
Mangesh Murlidhar Darwade
m/s shivam tools and equipment
BHAVIN INFRA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .