Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.6 LAccepted-AOC SHOP NO 259 LOHOGAON ROAD KALWAD KHANDVE NAGAR PUNE 411032 | PUNE | MAHARASHTRA | 411032 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹19.7 L+₹75,792 (4.01%)Rejected-Finance | L2 | Rejected-Finance High Rate | |
| 3 | L3₹21.0 L+₹2.1 L (11.2%)Rejected-Finance | L3 | Rejected-Finance High Rate | |
| 4 | L4₹21.5 L+₹2.6 L (13.5%)Rejected-Finance FLAT NO 06 BLDG NO B 2 PLEASANT PARK WANWADI PUNE 411040 | PUNE | MAHARASHTRA | 411040 | L4 | Rejected-Finance High Rate | |
| 5 | L5₹23.0 L+₹4.1 L (21.6%)Rejected-Finance | L5 | Rejected-Finance High Rate |
Tender Value
₹35.1 L
EMD Value
₹70,300
Closing Date
1 Oct 2024, 6:00 pmClosed
Garrison Engineer (Central) Pune
Garrison Engineer (Central) Pune, Arjun Marg, Pune-411001
8536 REPAIR/ REPLACEMENT/ MAINT TO STREET/ SECURITY LIGHT FITTINGS, SOLAR STREET LIGHT FITTINGS, LANDSCAPE LIGHT FITTINGS, LIGHTENING PROTECTION, POLES, CABLES AND ALLIED ITEMS IN THE AREA OF AFMC AND OTHER AREAS UNDER GE (CENTRAL) PUNE
2024_MES_671340_1
8536REPAIR/ REPLACEMENT/ MAINT TO STREET/ SECURITY LIGHT FITTINGS, SOLAR STREET LIGHT FITTINGS, LAND
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Garrison Engineer (Central) Pune
As per Tender NIT
9 documents required · 9 mandatory
₹500
Garrison Engineer (Central) Pune
₹70,300
Yes
5 Dec 2024
3 Sept 2024
3 Oct 2024
3 Sept 2024
1 Oct 2024
17 Sept 2024
Amount
Excavation in trenches, not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of LT UG cable/ poles in hard and dense soil and getting out complete all as specified and directed.
All as per item No 1 above but exe 1.5 mtr but not exc 3.00 mtr depth.
Returning filling in incluiding spreading levelling watering and well ramming in layers n.exc 25 cm complete all as specified and diredcted.
Removing excavated material to a distance not exceeding 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point all as directed
M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate for coping of new pole / reconstruction old damaged copings including including necessary form work complete all as specified and directed
M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in foundation of poles/ feeder piller box repair to floor/paths, road cuttings, fencing etc including use and waste of necessary form work and fair finishing without using extra cement complete all as specified.
Supply and laying in trenches/Floor/road or fixed to Pole/Wall GI pipe light grade with fitting of size 40 mm bore for protection of cable including dismantling existing pipe complete all as specified and directed by the Engineer-in-Charge.
Cutting of PCC/Hard standing/WBM road not exceeding 30 cm in width not exceeding 30 cm in depth for passing of GI pipe /cable line and making good of disturbed surface with PCC all as specified and dir by EIC. Note - PCC will be measured and paid separately
Dismantling of existing PCC coping (unreinforced) of any description and removal of debris to out of defence land , and fixing of the same to other location as directed by EIC. Note Rate of excavation, PCC, returning and filling will be measured and paid separately.
M & L for 100 mm bore dia Reinforced concrete pipes Class NP-2 half round (each of 1 RM long for bottom and top) including levelling of ground before laying of pipe complete all as specified and directed. Note : Two Half Round bottom & top with to measured 1 RM as one RM.
Taking down unserviceable under ground cable from trench/pole/wall etc of size and any cap all as specified and as directed.
Supply, lay, test connect and commissioning underground cable LT 1100 volt grade heavy duty XLPE insulated with aluminum stranded conductor armoured complete laid in trenches/fixed to poles /drawn through pipes with suitable size cable glands criping type cable lugs etc including taking out old UG cable all as specified and directed of the following sizes :-
(a) 6 Sqmm 2 core
(b) 10 Sqmm 2 core
(c) 10 Sqmm 4 core
(d) 16 Sqmm 4 core
(e) 25 Sqmm 3.5 core
Disconnecting and taking down defective street light fittings of any type/capacity/ brand from pole for repairing/ refixing and replacement of unserviceable parts like internal wiring, screws, nuts and bolts etc including daily checkeing and giving workability complete as directed by Engr-in-charge. Note :(i) Cost of minor items such as Screws nut bolts, wiring will be included in quoted rates and No extra payment will be allowed on this account (ii) The street light fitting cover shall be cleaned properly as directed during repair works and rate of the same is deemed to be included in quoted rates. (iii) Necessary tools ladder and other testing equipments etc shall be arranged the contractor. (iv) GI Pipe brackets, Electronic Driver and clamps shall be measured and paid seperately under relevant items.
Supply and fixing Street light fitting electronic constant current drivers/PCB/electronic gear suitable for 45 to 60 Watt LED flood light/street light fitting as required at site or as per sample all as specified and directed .
Supply and fixing Street light fitting electronic constant current drivers/PCB/electronic gear suitable for 70 to 90 Watt LED flood light/street light fitting as required at site or as per sample all as specified and directed .
Supply and fixing Street / flood light fitting electronic constant current drivers/PCB/electronic gear suitable for 120 to 150 Watt LED flood light/street light fitting as required at site or as per sample all as specified and directed .
Supply and fixing all weather Integral LED Street Light Luminaire 45 Watt comprising of powder coated aluminium housing, covered with glass or fiber cover in frame suitable for 50/40 mm GI Pipe complete with accessories internally pre wired and 3 core wire and necessary mounting arrangements all as specified including taking down old fitting all as specified and as directed.
Supply and fixing Integral LED Street Light Luminaire 60 Watt comprising of powder coated aluminium housing, covered with glass or fiber cover in frame suitable for 50/40 mm GI Pipe complete with accessories internally pre wired and 3 core wire and necessary mounting arrangements all as specified including taking down old fitting all as specified and as directed.
Supply and fixing LED FLOOD Light Luminaire 120 Watt comprising of with pressure die-cast hosing and toughened glass and individual LEDs with secondary lens optic with IP 66 ingress protection, complete with all accessories internally pre-wired and 3 core wire and necessary mounting arrangements all as specified and as directed.
Supply and fixing LED FLOOD Light Luminaire 150 Watt comprising of with pressure die-cast hosing and toughened glass and individual LEDs with secondary lens optic with IP 66 ingress protection, complete with all accessories internally pre-wired and 3 core wire and necessary mounting arrangements all as specified and as directed.
Disconnecting and taking down defective Bollard light/ Post top lattern light fittings of any type/capacity/ brand from 1/1.5/2 mtr height repairing and refixing and replacement of unserviceable parts like internal wiring, screw nut blots etc, including daily checkeing and workability complete as directed by Engr-in-charge. Note :(i) Cost of minor items such as Screws nut bolts & wiring will be including in quoted rate. No extra payment will be allowed on this account. (ii) The light fitting cover shall be cleaned properly as directed during repair works and rate of the same is deemed to be included in quoted rates. (iii) Necessary tools and other testing equipments etc shall be arranged the contractor.
Supply and fix new generation, Bollard light with opal acrylic diffuser, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution with high power LEDs as light source of cap (Minimum) 9 watts IP 65 protection and grouted in foundation sutable bolts, nuts and washers etc including electrical concetion with suitable copper wire, from junction box to light complete including taking down old fitting complete all as specifide and directed fittings.
Supply and fix new generation, post top light for indirect light with IP 65 protection. resistant to impact and corrosion, glare-free and better uniformity Warm white/white cap (minimum) 25W complete including taking down old light fittings.
Supply and fix FRP junction box light weight suitable for pole mounting including MCB SP 6 Amps single pole and necasry terminal for loop in loop out cable connection and suitable size glands of size 250 x200x105mm complete including taking down FRP junction Box all as directed.
Supply and fixing PVC sheathed insulated wire round or flat in shape with copper conductor 3 core 1.5 sqmm working voltage 1100 Volt PVC cable, insulated passing through pole fixed to FRP junction box to street light fitting for 11/9 mtr long pole including suitable size of lugs for looping including taking down old wire complete all as specified and directed by Engineer-in-Charge
Supply and fixing Power contactors 4 pole , 40 amp with 230 V~ coil and handle Manual override for test and repair function, complete all as per installed and as directed by EIC
Supply and fix in replacement of MCB SP 10 Amps,10 KA,'B' Series 230 Volts
Supply and fix in repair MCB TPN 63 Amps ,10 KA ,'B' Series,415
M&L for preparation of old painted surfaces of 9 Mtr long street light pole above ground level without removing any acessories and Repainting the pole with one coat of alumimium paint including clamps GI bracket etc and writing pole no with black paint all as specified and as required at site as directed.
M&L for preparation of old painted surfaces of 11 Mtr long street light pole above ground level without removing any acessories and Repainting the pole with one coat of alumimium paint including clamps GI bracket etc and writing pole no with black paint all as specified and as required at site as directed.
M & L in Replacement earthing with galvanised steel earth plate electrode 60 cm x 60 cm x 6.3 mm buried directly in ground earth pit not less than 2.25 m deep below normal ground level, with top edge of the plate vertically to depth of not less than 1.5 m below ground level connected to and including GI wire 4 mm dia and GI Protection pipe 15 mm dia light grade for protection upto the extent of 7.5 Mtr as earthing lead by means of GI bolts, nuts and washers etc connecting to equipment with provn of charcoal and salt etc all as per electrical plate No 3 of SSR Part-I incl RCC cover, M S angle iron frame funnel watering arrangement with GI pipe 20 mm dia and MS funnel, concrete pit including excavation and earth work in any type of soil and testing on completion etc complete Note : GI earthing wire and 15 mm dia GI protection pipe beyond 7.50 Mtr will be measured and paise separately.
Supply and fix earth continuity conductor or main earthing GI lead fixed to wall or pole on floor of size 4mm dia steel wire.
M & L in Replacement earthing with galvanised steel earth plate electrode 60 cm x 60 cm x 6.3 mm buried directly in ground earth pit not less than 2.25 m deep below normal ground level, with top edge of the plate vertically to depth of not less than 1.5 m below ground level connected to and including GI strip 32X6 mm and 40 mm dia GI pipe light grade for protection upto extent of 7.5 Mtr as earthing lead by means of GI bolts, nuts and washers etc connecting to equipment with provn of charcoal and salt etc all as per electrical plate No 3 of SSR Part-I incl RCC cover and MS angle iron frame, watering arrangement with GI pipe 20 mm dia and MS funnel, concrete pit including excavation and earth work in any type of soil and testing on completion etc complete (NOTE:-GI earth strip and protection pipe 40mm beyond 7.5m will be measured and paid separately)
M&L in replacement for GI strip 32X6 mm with saddles and fixing screws etc for roof conductors and down conductors above ground complete all as specified.
M&L in replacement for Aluminium strip 25mm x 3 mm with saddles and fixing screws etc for roof conductors and down conductors above ground complete all as specified.
Supply and fixing in replacement air termination single pointed aluminium rod 12mm dia and 300mm long complete all as specified and as directed.
Taking out existing electric pole any type and size complete with all accessories and romove from existing foundation and shifting to pole and fixing complete with foundation wotk & connected accessories an other location as per direction by Enrg-in-Charge complete. Note: Exc & PCC work will be measured and paid separatly.
Repair to hight mast light by lowring of over all assembly and repair , removal and re fixing of after maint of high mast light head, high mast light ring, motor, , wire rope clamp and bobbin arrangement, SS wire steel rope, electricl connection and other minor nut ,bolt and placing back to its original position complete all as spd and directed by EIC. Note - High mast light head, high mast light ring, steel rope, motor will be measured and paid separately.
Supply and fixing Stainless Steel wire rope of 4/6mm dia or as per existing in high mast light complete all as spd and directed by E-in-C
Supply and fixing as in repairs of high mast head suitable for light upto 21 Mtr high mast light having 6/8 Nos of Lantern along with nut bolt and washer complete all as directed by EIC
Supply and fixing as in repairs high mast light ring suitable for 6/8 lantern along with nut bolt washers complete all as spd and directed by EIC
Supply and fixing of rainproof LED Driver for bill board hoardings compatable with Input voltage AC 180-250, 50 Hz, Input voltage DC 12 V +-5%, IP 43, complete of existing wattage, type and compatability and as per direction of EIC.
Supply and fixing of submersible water proof light 9/12 Volte, 2 amp, with LED driver having with input voltage AC 200-240, 50 Hz, output voltage DC 12 V +-5% along with bracket to hold and fix the light assembly complete all as existing type and as per direction of EIC.
Supply and fixing of LED Aviation light /obstriction light on top of hight mast poles or building after removing the old unsv light fittings and fixing and testing of new light all as per existing samples complete ll as spd and directed by EIC.
Supply fixing and testing of single automatic street light switch suitable for single phase 1 KW load , outdoor panel having light sensing devise, that allows automatic switching of all outdoor lights. Automatic Switching ON at dusk having Low voltage trip and auto reset, MCB based over load trip and latch, auto reset , IP 54 enclosure of make Swadeep model No 02EC1KW1P or equvalient complete all as spd and directed by EIC.
GI bracket not less then 1.2 Mtr long made out of 40mm bore light grade, GI pipe, bend to shape as required complete with two Nos MS clamps fabricated out of MS flat of size 40 x 5 mm, nuts and bolts duly painted with two coats of aluminium paint of superior quality over a coat of red oxide primer, to be fixed on pole/on roof of building including taking down old brackets complete all as specified and directed by the Engineer-in-Charge.
Supply, Errecting and fixing of true Vertical position steel tubular swaged pole complete with coat iron base plate, finial taper plug, bolt, nuts and screw,weld and reduced section and logitudional weld Seam through out entire length of pole including 2 coats of black bituminious paint through out intrnely and externely up to planting depth and remaining exterior portion of pole with two caot of aluminium paint over a coat of red oxide as specified type 410 SP 31 (9.00 Mtr long) incl taking down old unserviceable pole all as specified and directed at site. NOTE - Excavation and Earth work and PCC in foundation shall be measured and paid seprately.
Dimentling and taking down old/unsv cross arms, bracing, supports etc complete all as specified and directed.
S&F cross arms bracings supports clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paints complte all as specified and directed.
Supply and fixing of HDPE , DWC pipe with a bore size of 50 mm incl all necessary fixtures and fittings, safely insert the cable into the HDPE DWC pipe, ensuring no damage to the cable during the process complete all as spd and directed by EIC.
Taking out defective Motor of capacity 1 HP from Hight mast light pole enclosure for its repair to civil works and refixing, testing the same to its original position complete all as spd and directed by EIC.
Rewinding of motor of capacity 1HP, 3 phase motor, 50 Hz with PVC insulated, coated copper winding wire of existing guage and other winding maerial such as insulating papers, sleeves, including repair of small parts like terminal and connetors, connecting cable complete all as spd and directed by EIC.
M&L safely removing the elctric supply from electric pole and trimming of branches of trees touching LT pole/street light by providing ladder/suitable vehicle /crane, and depositing the trimmed branches where directed not exceeding 50 mtr, including making elecricl connection as previous complete all as Spd and directed by EIC.
Supply and fixing LED FLOOD Light Luminaire 250 Watt comprising of with pressure die-cast hosing and toughened glass and individual LEDs with secondary lens optic with IP 66 ingress protection, complete with all accessories internally pre-wired and 3 core wire and necessary mounting arrangements all as specified and as directed.
Sunhari Electricals (BID ID -3111929)
PURVA ELECTRICALS AND ENGINEERS (BID ID -3116604)
Chaulya Enterprises (BID ID -3109785)
SHREE VAIBHAV ELECTRICALS (BID ID -3110758)
UNIQUE ENGINEERS (BID ID -3111854)
Suchit constructions (BID ID -3102117)
GANGA ENTERPRISES (BID ID -3124324)
Akanksha Enterprises (BID ID -3111562)
CHAITANYA WINDWELL (BID ID -3107455)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .