Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 801 VENUS BENECIA PAKVAN DINING LANE OPP RAJPATH CLUB S G HIGHWAY BODAKDEV AHMEDABAD 380053 | AHMADABAD | GUJARAT | 380053 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance NORTH SITE TROMBAY MUMBAI 400 085 | MUMBAI SUBURBAN | MAHARASHTRA | 400085 | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹96.5 L
EMD Value
₹1.9 L
Closing Date
15 Jul 2022, 6:00 pmClosed
Chief Engineer and Head, Technical Services Divisi
TSD, BARC
Maintenance and Addition/Alteration of Electrical Installations of various buildings at North site, BARC, Trombay, Mumbai-85
2022_BARC_693428_1
BARC/TSD/29/2022-23
Open Tender
Electrical Works
Item Rate
730 days
BARC, Trombay
As per NIT
8 documents required · 8 mandatory
₹0
₹1.9 L
Yes
TSD, BARC
22 Aug 2022
15 Jun 2022
19 Jul 2022
15 Jun 2022
15 Jul 2022
15 Jun 2022
15 Jun 2022 - 6 Jul 2022
4 Jul 2022
Amount
Deployment and operation of Four wheeler (5 seater) with driver as per TSS 1
Deployment of above said Vehicle
Operation of above said vehicle
Servicing and maintenance of electrical utilities as per TSS 2
S&M of Main panels up to 20 feeders.
S&M of Sub panels up to 10 feeders.
S&M of Change over panels with 2 feeders.
S&M of Distribution boards.
Maintenance of Lightning arrestor as per TSS 3
Maintenance of Earth station as per TSS 4
SITC of Spare parts as per TSS 5
20A 3Pin Metal clad Socket & plug Top
5/10A, 3pin plug top
15/20A 3pin plug top
120W fan stap regulator modular type.
6/10A, SP Modular switch.
16/20A, SP modular switch with indicator
6/10A, 5 pin modular socket.
16/20A, 5 pin modular socket.
3/4 Modular plate
6 Modular plate
8 Modular plate
12 Modular plate
6 to 32 A SP MCB
16 to 32 A DP MCB
40A TP MCB D-curve
63A TP MCB D-curve
40 A FP MCB,D-curve
63 A FP MCB D-curve
40 A, 30 mA DP RCCB (ELCB)
63 A, 30 mA DP RCCB (ELCB)
40 A, 30 mA FP RCCB (ELCB)
63 A, 30 mA FP RCCB (ELCB)
125 A FP, 36KA, MCCB
4 modular box with accessories.
8 modular box with accessories.
8 Modular plate with accessories for DLP
12 modular box with accessories.
Hylem sheet 3mm
TubeLight Starter 110/230V
Capacitor for fan
SITC of Light point wiring as per TSS 6
Primary switch box points with 2.5sqmm FRLS wire
Secondary switch box points with 2.5Sqmm FRLS wire
Primary lighting points with 1.5Sqmm FRLS wire
Secondary lighting points with 1.5Sqmm FRLS wire
Ceiling fan point With 1.5Sqmm FRLS wire
Exhaust fan point With 1.5Sqmm FRLS wire
SITC of Power point wiring as per TSS 7
Primary power points with 2.5sqmm FRLS wire
Secondary power points with 2.5sqmm FRLS wire
Power point for A/C and geyser with 4.0sqmm FRLS wire
Primary power points in DLP
Secondary power points in DLP
SITC of Lighting fixtures as per TSS 8
20 watts LED lighting fixture
40 watts LED lighting fixture
38 Watts Fullglow LED lighting fixture Recessed type.
70/75W LED Lighting fixture outdoor type.
35/36W LED Lighting fixture outdoor type.
9 watts LED Bulkhead Lighting fixture.
10W LED Lighting Fixtures Recessed Type.
18/20 watts 4" fts LED tube for existing fluorecent lighting fixture(Retrofitting).
9/10 watts 2"fts. LED tube for existing fluorecent lighting fixture(Retrofitting).
SITC of Fans as per TSS 9
1200 Sweep Ceiling fan powered by BLDC motor with remote
Wall fan, sweep 400mm
Padestal fan, sweep 400mm
Exhaust fans, Sweep 205/225mm
Air circulator fan, sweep 750mm
Exhaust fan 300mm
SITC of PVC conduit/ casing capping as per TSS 10
25mm PVC rigid conduit
25mm PVC flexible conduit
32mm X 12mm casing capping
SITC of Wiring with PVC FRLS copper wire as per TSS 11
1.5 Sq.mm PVC FRLS copper wire
2.5 Sq.mm PVC FRLS copper wire
4CX 2.5 Sqmm TRS wire
4CX 4 Sqmm TRS wire
SITC of Distribution Boards as per TSS 12
8 Way, TPN DBs with RCCB as PPI.
6 Way, TPN DBs with RCCB as PPI.
8 Way, VTPN DBs with 125A MCCB as incomer.
SITC of End termination as per TSS 13
4 C x 2.5/4/6 Sq.mm
4 C x 10/16 Sq.mm
3.5C/4 C x 25/35 Sq.mm
3.5 C x 50/70/95 Sq.mm
3.5 Core x 150/185 sq.mm.
3.5 Core x 300sq.mm.
3.5 Core x 400 sq.mm.
SITC of MCB/MCCB with MS Enclosure as per TSS 14
32 Amp. FP, MCB, D-curve
63 Amp. FP, MCB, D-curve
125 Amp. 25KA, FP, MCCB
SITC of Earth station as per TSS 15
SITC of Earthing strip/wire as per TSS 16
14 SWG copper wire
25mm x3 mm copper strip
SITC of MS box as per TSS 17
SITC of MS supports as per TSS 18
SITC Portable emergency light (LED) as per TSS 19
SITC of Extension Board as per TSS 20
Only installation of cable as per TSS 21
On Surface-Only installation of cable of size 4 C x 2.5/6/10 sq.mm
On surface-Only installation of cable of size 4 C x 16 / 25 sq.mm.
On surface-Only installation of cable of 4C or 3&½C x 35sq.mm. - to -95 sq.mm.
Underground-Only installation of cable of size 4 C x 10/16 / 25 sq.mm
Underground-Only installation of cable of 4C or 3&½C x 35sq.mm. - to -95 sq.mm.
Temporary Power Supply connection as per TSS 22
Painting of DB/Outdoor Panel/switch Box as per TSS 23
Painting of DB/switchbox
Painting of Panel
SITC of Insulating mat as per TSS 24
SITC of Straight through Joints as per TSS 25
3.5C/4 C x 10-to-25 Sq.mm
3.5C/4 C x 50-to-95 Sq.mm
3.5C/4 C x 185 Sq.mm
3.5C/4 C x 300-400 Sq.mm
Fault finding Work of LT cable of 4C/ 3 & ½ C x 25 to 400 Sqmm Cable as per TSS 26
Excavation work as per TSS 27
Soft Soil
Hard Rock/Road
Electrical Job Rectification as per TSS 28
MARINE AUTOMATION
AEW ELECTRICAL PVT.LTD
JAMES ELECTRICALS PRIVATE LIMITED
ABHISHEK INTEGRATIONS LIMITED
ELITE ELECTRICALS AND GROUP OF ENGINEERING SERVICES
G-TECH CONSTRUCTION & FABRICATORS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .