Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹59.8 LAccepted-AOC AMBALA CANTT | 1st | Accepted-AOC 1st lowest | |
| 2 | 2nd₹69.6 L+₹9.9 L (16.5%)Rejected-AOC | 2nd | Rejected-AOC 2nd | |
| 3 | 3rd₹71.5 L+₹11.7 L (19.6%)Rejected-AOC DINDHAR NAMUNDA V P O DINDHAR NAMUNDA DINDHAR PANIPAT HARYANA 132101 | PANIPAT | HARYANA | 132101 | 3rd | Rejected-AOC 3 rd | |
| 4 | 4th₹75.8 L+₹16.1 L (26.9%)Rejected-AOC DG 33 PUSHPA COMPLEX FIRST FLOOR HISAR | HISAR | HISAR | HARYANA | 4th | Rejected-AOC 4 th lowest | |
| 5 | 5th₹78.4 L+₹18.7 L (31.3%)Rejected-AOC VPO DAULATPUR DISTT HISAR 125122 | DAULATPUR | HISAR | HARYANA | 125122 | 5th | Rejected-AOC 5 th lowes |
Tender Value
Refer Docs
EMD Value
₹1.0 L
Closing Date
21 Jun 2021, 3:00 pmClosed
Executive Engineer
Public Health Engg. Division No.1 Hisar
DNIT for Renovation repair of water works structures alongwith distribution system including Functional Household Tap Connection in village Fransi Tehsil Distt Hisar
2021_HRY_173030_3
SE endst no. 6815-16 dated 17/05/2021
Open Limited
Civil Works
Works
120 days
Hisar
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,000
Yes
₹1.0 L
Yes
27 Aug 2021
14 Jun 2021
21 Jun 2021
14 Jun 2021
21 Jun 2021
14 Jun 2021
Amount
Supply & erection of Horizontal spindle split casing type puming sets of following duties directly coupled to AC squirrel cage induction type motor with 1440 RMP, 3 Phase, 50 Hz and accessories as described in Schedule No.II complete in all respect with priming arrangement with complete base frame. (A) Raw water pump set 600 LPM 12 mtr. head
B) Clear water pump set 600 LPM 40 mtr. Head
Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900 mm having following items. A )For Raw water Pumpsets for 600 LPM 12 mtr head = 2 nos. a) Main switch 63 Amp 2 No.(L&T Siemens, ABB) b) Volt meter 100x100 mm range 0 to 500 volt 1 No.(AE/KAPPA/L&T) C) Amp meter 100X100mm range 0 to 100 Amp 2 Nos. (AE/KAPPA/L&T) D) CT 100/ 3 Nos. (AE/KAPPA/L&T) E) VSS & ASS 4 No. of approved make F) SPP 4 No. of approved make g) Motor starter, Star delta 2 No.for 600 LPM x 12 Mtr Head (L&T Simens. ABB) H) Capacity suitable capacity = 2 Nos. I) Indicating Lamp - One Set j) Change over switch 100 Amp = 1 No.
Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900 mm having following items. A )For Clear water Pumpsets for 600 LPM 40 mtr head = 2 nos. a) Main switch 63 Amp 2 No.(L&T Siemens, ABB) b) Volt meter 100x100 mm range 0 to 500 volt 1 No.(AE/KAPPA/L&T) C) Amp meter 100X100mm range 0 to 100 Amp 2 Nos. (AE/KAPPA/L&T) D) CT 100/ 3 Nos. (AE/KAPPA/L&T) E) VSS & ASS 4 No. of approved make F) SPP 4 No. of approved make g) Motor starter, Star delta 2 No.for 600 LPM x 40 Mtr Head (L&T Simens. ABB) H) Capacity suitable capacity = 2 Nos. I) Indicating Lamp - One Set j) Change over switch 100 Amp = 1 No.
Supply erection testing of ISI marked copper wire for 4 Nos motors with under ground system in PVC and flexible pipes copper wire size 6 Sq. mm complete in all respects with accessories like thimble etc.
Supply erection testing of ISI marked copper wire for 2 Nos panel boards from main switch to panel and wiring of panel with size 10 sq. mm (copper wire ) ISI marked complete in all respects with accessories like thimble etc. complete in respects.
Supply ,errection testing of light fitting including wire in the Pump Chamber with material upto 10 point including switch button , plug PVC, condut pipe & copper wire etc as per approved specifications complete in respects.
Supply and fixing following CI D/F pipe and specials/ bell mouth/ including cost of joining materials laying jointing, refilling of including making adequate support of masonry/ concrete for delivery and suction pipe from bell mouth in collecting tank upto the rising main laid by the department as per plan shown from the foundation wall of pump chamber for all the raw water and clear water pumping sets at water works in position as per specification given in schedule No.II. for Pumping Machinery (i) 200 mm i/d
Taking out all layer of filter media and placing after washing & cleaning in to the filter bed
Taking out RCC bed plat washing and relaying the same afea of filter bed
GI special G.I. Nipple / please approval / 15 mm Having length 150 mm long 1/2' x6'
GI special / G I elbow / providing and fixing GI special Elbow class -II medium duty to entire satisfaction of Engineer- in- charge (make- Jindal/ Parkash/ Tata) complete in all respect (15 mm i/d) /15 mm
Credit of old Pumping machinery (i) Raw water
Credit of old Pumping machinery (ii) Clear water
Bidder Name
Amount
M/s San Enterprises(GSTN-06ACSFS5827K1ZE)
sonu sangwan contractor(GSTN-06BZWPS4038J1ZM)
NASEEB SINGH CONTRACTOR(GSTN-NA)
RAVINDER KUMAR(GSTN-NA)
SANDEEP KUMAR CONTRACTOR(GSTN-NA)
RAVINDER KUMAR
sonu sangwan contractor
NASEEB SINGH CONTRACTOR
M/s San Enterprises
M/s San Enterprises
RAVINDER KUMAR
sonu sangwan contractor
NASEEB SINGH CONTRACTOR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .