Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹10.0 L
EMD Value
₹20,000
Closing Date
16 Jul 2021, 6:00 pmClosed
AGE I RD AVADI
AGE I RD AVADI CHENNAI 600054
REPAIRS DAY TO DAY MAINTENANCE OF INTERNAL ELECTRIFICATION AT TECHNICAL AREA AT CVRDE AVADI
2021_MES_452787_1
8317/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
AVADI
As per NIT
8 documents required · 8 mandatory
₹500
AGE I RD AVADI
₹20,000
Yes
20 Jul 2021
19 Jun 2021
19 Jul 2021
19 Jun 2021
16 Jul 2021
2 Jul 2021
19 Jun 2021 - 2 Jul 2021
Amount
Notes:- 1) All works under this contract shall be day to day maintenance and repair of Internal electrification. Contractor shall provide and deploy adequate experience tradesmen (minimum one electrician and one helper daily) to carry out day to day repair against complaint in MES complaint centre in Technical area on working days at 0830 hrs to 1630 hrs. Contractor shall be penalised @ Rs. 120/- per complaint per day, If fails to attend the complaint within 8 hours. 2) In case of any breakdown /emergency contractor shall make arrangement to attend and rectify the complaints in odd hours on Sunday holiday also. The rates quoted by contractor shall deemed to be include this aspect. Every day contractor shall deposit the completed job card to complaint cell/JE. The contractor shall provide necessary tools, plants and ladders to carryout day to day maintenance and repair works. 3) The contractor will get the names of tradesman approved from Engr-in-Charge. The accepting officer reserves the right to reject the employment of such person forthwith. No claim what-so ever be entertained on this regard.
Taking down S & F in repair switch piano flush button type 15 amps single pole one way. complete all as specified and directed.
Taking down S & F in repair switch piano flush button type 5 amps single pole one way. complete all as specified and directed.
Taking down S & F in repair Switch socket combination 3 pin t 5A/16A, 5 in 1 flush type complete all as specified and directed.
Taking down S & F in repair Switch socket combination 5 A 250V AC universal with box in polycarbonate. complete all as specified and directed.
Taking down S & F in repair only socket outlet multipurpose 2 in 1, 5 and 15 Amps. complete all as specified and directed.
Taking down S & F in repair only socket outlet multipurpose 2/3 pin 5 amps flush button. complete all as specified and directed.
Taking down S & F in repair only fan regulator, electronic, step type 120 watt and connection complete as directed
Taking down S & F in repair electric bell Ding-Dong AC 230 Volt SP with screws washers complete all as specified and directed.
Taking down S & F in repair bell push flush type 5 amps complete all as specified and directed.
Taking down S & F in repair Supply only single pole and neutral enclosure with a two pin earth plug and socket complete with one single pole MCB 20 Amp
Taking down S & F in repair double door Distribution board TPN 4 way suitable rated busbar complete all as specified and directed.
Taking down S & F in repair double door Distribution board TPN 6 way suitable rated busbar complete all as specified and directed.
Taking down S & F in repair double door Distribution board TPN 8 way suitable rated busbar complete all as specified and directed.
Taking down S & F in repair double door Distribution board SPN 8 way suitable rated busbar complete all as specified and directed.
Taking down S & F in repair double door Distribution board SPN 4 way suitable rated busbar complete all as specified and directed.
Taking down S & F in repair Angle Lamp holder, PVC/ Polycarbonate type with back plate suitable for batten fittings. complete all as specified and directed.
Taking down S & F in repair Hylem sheet 3 mm thick size 9'' x 11'' including cutting of switch,socket. complete all as specified and directed.
Taking dopwn S & F in repair Hylem sheet 3 mm thick size 8'' x 5'' including cutting of switch,socket complete all as specified and directed.
Taking down S & F in repair SPN MCB 32 amp, 240 v, 50 Hz AC and suitable for 10 KA breaking capacity,
Taking down S & F in repair Single pole MCB 6 to 32 amp, 240 v, 50 Hz AC Made10 KA breaking capacity. complete all as specified and directed.
Taking down S & F in repair TPN MCB 40 240 v, 50 Hz AC Made10 KA breaking capacity. complete all as specified and directed.
Taking down S & F in repair TPN MCB 63A 240 v, 50 Hz AC Made10 KA breaking capacity. complete all as specified and directed.
Taking down and S & F in repair retrofit LED tubelight with very high efficacy 4 ft length not less than 20W with double side connection suited for installation in existing T8 fitting with G13 lamp holders complete all as specified and directed.
Takng down and S & F in repair surface and wall mounting LED batten fittings 4ft not less than 20W high 5700K lumen efficiency batten with Aluminium housing & integrated electronic driver complete all as specified and directed. Havells Cat NoLUMILINE PLUSBS20WLED865SPCSS/ WIPRO Cat No LL20-221-XXX-65NE3/ PHILIPS Cat No BN021C LED20S PSU CW GR
Taking down S & F in repair surface and wall mounting LED not less than 10W batten with aluminium housing of 2ft length complete all as specified and directed. Make Havells Cat NoLUMILINEPLUSBS10WLED865SPCSS/ Philips Cat No:BN 021 LED10S 6500PSUGRS1/ Wipro Cat No LL20-111-XXX-65NE3
Taking down S & F in repair 1x36/40 watt tube rod 4 ft for in existing T8 fitting with complete all as specified and directed.
Taking down S & F in repair 1x 20 watt tube rod 2ft for in existing T8 fitting with complete all as specified and directed.
Taking down S & F in repair for two single core (submain) FRLS PVC insulated cable with 4 sqmm nominal cross sectional area stranded copper conductor and one single core green FRLS PVC insulated 4 sqmm stranded copper conductor earth continuity cable drawn through non metallic rigid PVC conduit in wall/ceiling complete all as specified and directed.
Taking down S & F in repair for two single core (submain) FRLS PVC insulated cable with 2.5 sqmm nominal cross sectional area stranded copper conductor and one single core green FRLS PVC insulated 2.5 sqmm stranded copper conductor earth continuity cable drawn through existing non metallic rigid PVC conduit in wall/ceiling complete all as specified and directed.
Taking down S & F in repair electronic ballast of 1x36/40w suitable for FTL fittings complete all as directed.
Taking down S & F in repair starter suitable for 18/28W/36/40W tube light fittings complete all as specifed and directed.
Taking down S & F in repair modular switch 1way 6/10A one module all as specifed and directed.
Taking down S & F in repair modular switch 1way 16A one module all as specifed and directed.
Taking down S & F in repair modular Bell push 6A 1 module complete all as specifed and directed.
Taking down S & F in repair replacement of modular socket, 6A - 2/3 pin combined 2 module,complete all as specifed and directed.
Taking down S & F in repair replacement of modular socket, 15A - 2/3 pin combined 2 module,complete all as specifed and directed.
Taking down S & F in repair replacement of modular type fan step regulator 100W 2 Module type all as specifed and directed.
Taking down S & F in repair replacement of white cover plate with frame, 3module complete all as specifed and directed.
Taking down S & F in repair replacement of white cover plate with frame, 4module complete all as specifed and directed.
Taking down S & F in repair replacement of white cover plate with frame, 6module complete all as specifed and directed.
Taking down S & F in repair replacement of modular metal flush box 3 module complete all as specifed and directed.
Taking down S & F in repair replacement of modular metal flush box 4 module complete all as specifed and directed.
Taking down S & F in repair replacement of modular metal flush box 6 module complete all as specifed and directed.
Taking down and S & F in repair recess mounted 2x2 feet LED light fitting min 30W,5700K,230V, 50Hz high lumen efficiency extruded aluminium/ polycarbonate/CRCA body incl integrated electronic driver, pre wired connecting up twin core twisted flexible copper cable complete all as specifed and directed. Havells Cat No PLUTONEO2X2PLR34WLED857S/ Philips Cat No RC380B LED30S -6500 G4 L60 W60 PSU OD OC / CG Cat No LCTLRNE-30-FO-CDL or equivalent updated Cat No of respective brands.
Taking down and S & F in repair replacement of recess mounted 2x1 feet LED light fitting 20W high lumen efficiency, min 5700K , 230V 50Hz extruded aluminium/polycarbonate/CRCA body incl integrated electronic driver, pre wired connecting up twin core twisted flexible copper cable complete all as specifed and directed. Havells Cat No PLUTO2X1PLR20WLED857S/
Taking down and S & F in repair in fluorescent PL-36W 4Pin 230V, 50Hz on surface/recess mounting fittings any size complete all as specifed and directed.
Taking down carefully (copper/aluminum) point wiring complete of any type (batten/surface conduit) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants regulators etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster or tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed.
S & F in repair for Point wiring with 1100Volts grade, single core, PVC insulated FRLS cable multi-stranded copper conductor of size 1.5 sqmm nominal area for phase and neutral, drawn through and including PVC casing caping of suitable size, with all necessary fittings and accessories fixed on walls/ ceiling with one run neutral and one run of single core cable of same description above but green colour in continous earthing wire 1.5 Sqmm connected to common earth dolly including PVC junction / mounting boxes on / in the wall / ceiling for piano switches/ switch socket combination/ fan regulators etc and MS/GI junction box duly covered with 3mm thick hylam sheet complete for the following :-
(a) One light point controlled by one single pole 5A switch
(b) One fan point controlled by one single pole 5A switch
(c) One switch socket out let point 5A on independent board
(f) One bell point controlled by one single pole 5 Amps bell push
All as per item No 49 here in before but for PVC insulated FRLS copper conductor of size 2.5 sqmm for switch socket multipurpose 15 Amps including provision of 2.5 Sqmm PVC insulated FRLS copper conductor cable as earth continuity conductor on independent board omplete all as specifed and directed.
All as per item No 49 here in before but for PVC insulated FRLS copper conductor of size 4.0 sqmm for switch socket multipurpose 15 Amps/metal clad point including provision of 4Sqmm PVC insulated FRLS copper conductor cable as earth continuity conductor on independent board complete all as specifed and directed.
Taking down and S & F in repair ceiling rose 3 phase/PVC/ polycarbonate, isolated body three terminal complete all as all as specifed and directed.
Taking down S & F in repair sub main wiring with 2runs of 6sqmm single core PVC insulated FRLS cable with copper conductor multistranded 1100 volts grade including PVC casing and capping and accessories and fixing arrangements fixed to surface on wall, floor or ceiling etc including one run 6 sqmm PVC insulated FRLS multistranded copper earth continuity conductor and connecting to main earth dolly incl taking down u/s aluminium wiring any size complete all as specified and directed. Note : Three run of copper conductor and one run of PVC casing and capping together taken as one length for measuring unit length.
Taking down and S&F fix GI earthing complete with galvanised steel earth plate electrode 60x60cm x 6.0mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to and including using of 4 mm GI wire as earthing lead by means of bolts, nuts, check nuts and washers of galvanised steel , connected to earthing test point, all as specified & indicated, including testing on completion including earth work and excavation in any type of soil/rock, PCC 1:3:6 type C1, earthing chamber, precast RCC slab 50mm thick in cement concrete 1:2:4 type B1 reinforced with welded steel wire febric weight hot less than 4 Kg/Sqm, funnel with GI watering pipe of 20mm bore, medium grade wire mesh and lugs, GI protection pipe of 15mm bore light grade upto 7.50 mtr long test point and testing complete etc all as specified and directed.
Taking down and S & F in repair Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire.all as specified and directed.
EASHWAR ELECTRICALS
M/s GM Constructions
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .