Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.4 LAccepted-AOC 180 10 STREET NO 10 HARPAL NAGAR NEAR TRIVENI MANDIR BHATTI ROAD BATHINDA 151001 | BATHINDA | PUNJAB | 151001 | ₹18.4 L | L1 | Accepted-AOC Low Bid |
| 2 | L2₹18.4 L+₹7,264 (0.40%)Rejected-Finance | ₹18.4 L+₹7,264 (0.40%) | L2 | Rejected-Finance High Bid |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
26 May 2023, 11:00 amClosed
Executive Engineer S.A.S Nagar
XEN office, Vikas Bhawan, Sector 62, SAS Nagar
P/Laying Interior Furnishing for Recording Studio and Control Room at SIRD Complex Sec-62, S.A.S Nagar.
2023_DRDP_102441_1
PRD/SASN/2023/07
Open Tender
Civil Works
Item Wise
60 days
SIRD Complex, Sector 62
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,000
Yes
₹40,000
Yes
9 Jun 2023
16 May 2023
26 May 2023
16 May 2023
26 May 2023
16 May 2023
Amount
RECORDING STUDIO Supplying and Fixing Acoustic False Ceiling of Sound Dampner 12mm made of compressed Wood Fibre made with inorganic compound with mat black colour size 1218x1218mm installed on VIB Curb hanger with Engineered Wooden Studs and infill of Absorb Wool 50mm 1000GSM for excellent Results.Supplying and Fixing ‘APHONY FIBRETTE ‘ tiles made of Wood Fibre 1mm width cement composites 15mm thick with an option of colours as per the choice of the Architect/ person in charge of size 595x595 mm . Has excellent noise absorption of 1 NRC as per ISO: 354-1985 and ASTM 423-90 a, Density 400 Kg/ m3, meets stringent Fire Ratings ASTMD-876 and Fire Class -1 as per BS 476 part 5 and 6,Class P-not easily ignitable as per BS-476-Part 5 (Ignitability for material).This is applicable for core and class 1 as per BS 476-Part 7 (Method for classification of surface spread of flame) , weather resistance as per IS 3308, Thermal Insulation as per IS:3346-1980 with relative humidity of 90% RH at 60o Celsius(140o Fahrenheit) for 15 days= No deterioration. Conforms to En 131682001 and are RoHS Complaint. Can be installed on T24 grid system of 0.6mm thick Main ‘T’ length minimum 3000mm, web minimum 35mm to be placed at 600mm centre to centre and secondary cross ‘T’ of length 600mm web minimum 35mm inter locked, Wire Support for Main T to be taken at every 1200mm length wise and 600mm width wise,Specially designed for Acoustic Vibration management and long life with a backing of 50mm 1000 GSM thick absorbwool tested as per Fire Retardant ASTMD 635-1991 and IS 15061-2002 for excellent results. Himalyan Acoustics, Anutone.
Supplying and Fixing Acoustic Wall Panneling of Sound Dampner 12mm made of compressed Wood Fibre made with inorganic compound with mat black colour size 1218x1218mm installed on VIB Curb hanger with Engineered Wooden Studs and infill of Absorb Wool 50mm 1000GSM for excellent Results.Supplying and Fixing ‘APHONY FIBRETTE’ tiles made of Wood Fibre 1mm width cement composites 20 mm thick with an option of colours as per the choice of the Architect/ person in charge of size 600X1200 mm with taper edge. Has excellent noise absorption of 0.70 NRC as per ISO: 354-1985 and ASTM 423-90 a, Density 400 Kg/ m3, meets stringent Fire Ratings ASTM D- 876 and BS:476 , weather resistance as per IS 3308, Thermal Insulation as per IS:3346-1980 with relative humidity of 90% RH at 60o Celcius(140o Farenhite) for 15 days= No deterioration. Conforms to En 131682001 and are RoHS Complaint.Himalyan Acoustics, Anutone.
Supplying and Fixing of ISO Board 12mm on Floors made of compressed Wood Fibre made with inorganic compound with mat black colour size 1218x1218mm installed on Engineered Wooden Studs and infill of High density insulation for excellent Results.3" PCC will spread over the Board to be done by the Client.
Supplying and fixing of acoustic door of 56 mm having an STC rating up to 50. The Door will be filled with high acoustic materials of 2 layers of 8mm water Proof Acoustic Ply with Dampner sheet, 2 layers of 10mm thick absorb wool 300 GSM, Sound Dampner 12mm 1218X1218mm made of 10mm compressed wood cement Composites 1250kg/m3 and 2mm dampner sheet 37 STC as per ISO 140 (part III) -1995. Final finish with teak ply 4mm thick interior ad exterior side. The door frame will be made of engineered Wood/teak wood, frmae on all four sides or three sides frame and drop seal below will be provided along with the door. High load bearing hinges will be provided along. Fire resistant for 120 min as per IS 36 (4 part-II) & (Part 20 &22) Door Accessories : Door Closer, Door H-Type Pull Handle, & Outdoor Liver (Trim Lock).
Providing and fixing Cut pile tufted Carpet flooring made of 100% BCF heatset nylon, Dyed by Chromojet injection dye with a tufted weight of +/- 800 G/SQM , and a total weight of 2000 G/SQM with primary backing in woven polypropelene and secondary synthetic action back. Approved Makes:Wellspun, Goldface ,Interface
RECORDING/BROADCASTING Providing and fixing Fiber cement board 75mm thick drywall partition system, which include Galvalume wall frame system, comrprising of 51mm Floor and Ceiling track profile, 0.5mm thick, having two equal flanges of 32mm, fixed to the floor and ceiling,in plumb with each other, with nylon sleeves and steel screws at 610mm; Vertical Galvalume studs of size 51mm, 0.5mm thick, having one flange of 42mm and another flange of 44mm and two equal lips of 5mm insert fixed into the track profiles at 610mm centres. 12mm thick Fibre Cement Board (confirming to IS 14862;Type-B, catagory-3) are then screw fixed on the either side of the framework, with 25mm Screw Fibre Cement screw, at 300mm centres.The joints of Fibre cement board are to be filled with jointing Compound. The rate shall include providing openings for windows glazing and doors with additional support, wherever required. all complete as per direction of Engineer-in-charg
Providing and fixing mineral fibre false ceiling tiles at all heights With 16 mm thick beveled tegular mineral fibre Anti-microbial false ceiling tile of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflection > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge.
Supply & installation of frameless glass Door of size 2100 x 1000 of make with overpanel / sidelight using 12mm thick toughened glass of approved make with die cast patch fitting with stainless steel cover PT 10,PT 20 , PT 24 ,US-10, . pull Handle TGDI-H 450 back to back with 350mm CTC, adjustable fixing for glass ,Length =450mm, 25mm dia, -SS304 Finish: mill , Floor spring BTS 75V with std. spindle and cover plate. As per DIN EN 1154.(500,000 cyle tested ) , Finish: Satin stainless steel. Floor stop half dome with 45mm dia with fixing accessories, in satin Chrome ,Final certifications of products should be submitted be from the product manufacturer for the originality of the product and manufacturer should be have its own service team . The above work complete in all respect as per approved drawings and to the satisfaction of Architect /Engineer-in-Charge.
Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats)
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish
onkar plaster decoration works
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .