Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.4 LAccepted-Finance F IA 24 4210 CO JAYKRISHNAPUR P O BEGAMPUR DIST HOOGHLY | BEGAMPUR | HOOGHLY | WEST BENGAL | ₹35.4 L | L1 | Accepted-Finance Offer Lowest bid therefore Provisional order issued |
| 2 | L2₹35.6 LRejected-Finance 10B DR LAHIT BANERJEE SARANI GROUND FLOOR KOLKATA 700 073 | KOLKATA | KOLKATA | WEST BENGAL | 700073 | ₹35.6 L | L2 | Rejected-Finance That the bid is not L1 |
| 3 | L3₹36.7 LRejected-Finance 86 TOLLYGUNGE CIRCULAR ROAD KOLKATA WEST BENGAL 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | ₹36.7 L | L3 | Rejected-Finance That the bid is not L1 |
| 4 | L4₹41.6 LRejected-Finance 19 LAKE TEMPLE ROAD KOLKATA 700029 | KOLKATA | WEST BENGAL | 700029 | ₹41.6 L | L4 | Rejected-Finance That the bid is not L1 |
| 5 | L5₹41.8 LRejected-Finance | ₹41.8 L | L5 | Rejected-Finance That the bid is not L1 |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
2 Jan 2026, 1:00 pmClosed
EE-II KNHED PWDte.
KIT Building Annex, 4thFloor,P-16, India Exch. Place Extn., Kolkata -700073
Replacement of old unitary A.C (more than 10 years) machine at different locations of MCH Main building, Ezra, Shyamacharan, Principal Office, Pathology, Central Lab and Anatomy building under MCH
2025_WBPWD_962929_1
WBPWD/EE-II/KNHED/NIQ-59/ 2025-26
Open Tender
A/C ORG
30 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹84,000
OFFICE OF THE EE KNHED PWDte.
17 Feb 2026
28 Nov 2025
5 Jan 2026
28 Nov 2025
2 Jan 2026
5 Dec 2025
4 Dec 2025
Amount
Dismentaling the existing A.C Machine (including electrical connection) both indoor & outdoor and submit the PWD section office as per direction of EIC
Supply & delivery 1.5 TR capacity concealed type Split Air Conditioner of rated cooling capacity of 18000 BTU/hr, with 1 No. Rotary compressor, 1 No. IDU of rated power supply - 230V - 1ph-50Hz, 1 No. ODU of rated power supply - 230V, 1ph, 50 Hz, Air-flow/per IDU :- 600cfm, (Gas : R410A )(Make : Hitachi / DAIKIN/O General)
Supply & delivery 2.0 TR capacity concealed type Split Air Conditioner of rated cooling capacity of 24000 BTU/hr, with 1 No. Rotary compressor, 1 No. IDU of rated power supply - 230V - 1ph-50Hz, 1 No. ODU of rated power supply - 230V, 1ph, 50 Hz, Air-flow/per IDU :- 800cfm, (Gas : R410A )(Make : Hitachi / DAIKIN/O General)
Erection, testing and commissioning charges for the above said 2.0 / 1.5 TR concealed Split AC. The Indoor (IDU) & Outdoor (ODU) unit must be supported by structure made of 40 x 40 x 5 mm amgle and tie rod incl. necy. Painting & as per direction & satisfaction of EIC.
Copper Refrigeration pipe line for Liquid Line hard drawn / Soft Cu piping (1/4" OD with 0.6 mm thick) & Copper Refrigeration pipe line for Suction Line hard drawn/ soft Cu piping (5/8" OD with 0.7 mm thick) with necy supports & brackets , elbow, Socketing , Brazing as per direction of EIC. (MK: Ryoku/ Totaline/ Mandeep)
Supply & Fixing of Nitrile Rubber tube insulation (make : Twiga/ supreme) of 9 mm thick on Suction & Liquid Line Copper Pipe incl rarring/ Bube tape.
Control Cabling from Condensing Unit to Control Panel, 4 core 2.5 sq.mm. communication Copper Cable (Mk. Finolex / Havell's/ KEI/ Polycab)
Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007, with all necessary accessories. specials viz, socket, bend, tee, union, cross, elbo, nipple. longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete în all respect including cost of all necessary fittings as required jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. CPVC Pipes Class-1, SDR-11 of dia PWD Sch S&P P-29, Item no-1(a) (make-- Finolex/ Oriplast/supreme) a) 25mm
Charges for Scaffolding arrangement including lifting for outdoor & indoor units.
FRAME WORK Enclosed Safety Cage for ODU :: Supplying, fabrication & fixing 3 Nos. M.S U-channel of 6mm thick of size (75mm X 40 mm X 40mm) of 1m length for making platform for installation of outdoor unit of 1.5TR / 2.0 TR Concelled split AC incl. drilling 2 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete (1:1 1/2:3) etc. fabricated with 2 Nos. horizontal angle of 25mm X 25mm X 5mm of 1m. length incl. S&F of enclosed safety cage (for ODU) made of angle (25 X 25 X 5 mm) and flat (25 X 5 mm) iron with necessary painting with 02 coat of R.O. primer (Asianpaint / Shalimer / Berger) incl. shade arrangement with corogated PVC shade with proper clamping arrangement incl. fixing of ODU as per direction of EIC.
Cu Pipe Line Safety Grill Enclosure :: S & installation of rectangular type M.S frame of size 1’ x 1’ x 1’ of 25 mm M.S flat with 02 nos interconnections by 25 x 6 mm M.S.flat with 25 x 25 x 5 mm M.S angle with suitable clamping arrangement as required. All angle are jointed by argon welding system. M.S. bar gap at 2’’ distance. Whole structure are grouted on wall at each 18" gap with 3" M.S. flat leg splitted at end ( 4" bullet fastener are to be used where grouting will not be possible) and mending good the damage to original finish incl all necy. materials, tools and tackles incl charges of scaffolding and painting with 02 coat of Synthetic enamelled paint over 02 coat of R.O. primer (Asian Paint / ICI / Berger) incl. welding, carriage and transportation.
Wrapping both the copper pipe with kenofoam insulation by 26 SWG aluminum sheet to make it vermin proof.
Cutting of Grill of a window ;in shut two number hinge & lock & key arrangement and mending good the damages by making door like arrangement for permanent access to ODUs.
Supplying and Fixing of 9.5mm plywood board incl. painting for closing the opening of the window AC as per direction of EIC.
Cost of cutting the wall for the installation of refrigerant pipe line and mending good the damages to original finish incl. damp proff treatment with water resistant materials so that no water seepage happen though the wall of the working area as per direction of EIC.
SITC of 1.8 Ton 3 Star Non Inverter Window AC (Copper Condenser) , 3 Star Rating, Hyper Tropical Rotary Compressor For Rooms up to 200 sq.ft Power Consumption: 1950 Watts Refrigerant: R32/ R 410A , (MK: O GENERAL -AXGB22BBAA-B/ Mitsubishi Heavy) (Brand as per choice of EIC) . Fream work should be consider during installation.
Supply & Delivery 250V control starter type OLP 30M, 11-21A range, starter with AC looad display (make-- ultratech/Electron)
Supply & Delivery of 110-240 V, 50HZ 16A (NO) & 5A (NC)Digital time Switch- CRONO CAT NO: 67DDTO MK: LK/ equivalent of Seimens/Schneider
Supply & Deliver OF 25A 2 NO 230V 50/60HZ Modular type Contactor. (Make - LK - Cat No - AUMC2002501 / equivalent of Seimens/Schneider)
(Rate should be quotated including PF, ESI, and Bonus all taxes and duties, GST)
CARRION AIR COOLING (BID ID -7631159)
Lyric International (BID ID -7792465)
Shinryo Suvidha Engineers India Pvt. Ltd. (BID ID -7777210)
TRANSTECH (BID ID -7753607)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx