| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.2 CrAccepted-AOC E 261 AMAR COLONY LAJPAT NAGAR IV LAJPAT NAGAR IV SOUTH DELHI DELHI 110024 UDYAM DL 08 0001872 09AAACB0262A1ZF B S 07AAACB0262A1ZJ R 09AAACB0262A1ZF M | SOUTH EAST DELHI | DELHI | 110024 | ₹1.2 Cr | L-1 | Accepted-AOC L-1 |
| 2 | L-2₹1.5 CrRejected-AOC | ₹1.5 Cr | L-2 | Rejected-AOC L-2 |
| 3 | L-3₹1.5 CrRejected-AOC 96 ELECTRONIC CITY COMPLEX BANGALORE KARNATAKA 560100 | BENGALURU URBAN | KARNATAKA | 560100 | ₹1.5 Cr | L-3 | Rejected-AOC L-3 |
| 4 | Rejected-Technical B 46 INDUSTRIAL AREA SECTOR 59 NOIDA UP 201301 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | - | - | Rejected-Technical Un-Responsive Bid |
| 5 | Rejected-Technical G1 12 INDEXEL ENGINEERING ROAD NO 4 I P I A KOTA KOTA RAJASTHAN 324005 UDYAM RJ 24 0006878 08AADCI0760M1ZF R M MII STATUS AS VERIFIED | KOTA | RAJASTHAN | 324005 | - | - | Rejected-Technical Un-Responsive Bid |
Tender Value
Refer Docs
EMD Value
₹3.3 L
Closing Date
24 Jun 2020, 5:00 pmClosed
Chief Engineer
Office of the Chief Engineer, Equipment and Material Management, Irrigation and Water Resource Department, Ganga Sinchai Bhawan, Telibagh, Lucknow, Uttar Pradesh
Supply, Installation, Testing, Commissioning, Training, Maintenance, Electrification and Automation with SCADA System Including Renovation and Furnishing of existing Barrage Control Room at Adwa Barrage, Mirzapur, Uttar Pradesh
2020_IRRWB_458615_1
22/CE(E and MM)/NHP/UP(SW)/2019-20
Open Tender
Miscellaneous Works
365 days
Adwa Barrage
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
Yes
NATIONAL HYDROLOGY PROJECT UPSW IWRD LUCKNOW
₹3.3 L
Lucknow
17 Feb 2021
16 Apr 2020
25 Jun 2020
16 Apr 2020
24 Jun 2020
16 Apr 2020
21 May 2020
LOCAL CONTROL SYSTEM FOR ADWA BARRAGE CONTROL
Supply of PLC/RTU system with software development of PLC/RTU, Control Panel with front door opening cabinet, fitted with Power buses, MCBs & modem. Suitable power supply to power up PLC/RTU panel, 7” or above HMI display & Industrial type electrical fitting & cabling with suitable conduits complete for all related field instruments, as per technical specification.
Supply of Shaft Encoder based rotary position sensor with local digital Display & Proximity limit switches type Gate Position Sensors for indication and monitoring of Spillway gates, Intake Gates, Silt flushing gates including cabling & integration with PLC/RTU as per technical specifications.
Supply of 3 Phase VFD Starter panel for each motor of Barrage gates which shall consists of VFD, S.P.P, MCB, OLR, Timer, Main Switches including cabling & Electronic Digital Indicator complete as per technical specifications.
Supply of LTE Surveillance IP based 3G/4G Bullet Camera with Sim Card Slot, 2 Mega Pixel 2 OR 4 Array/ 72 LED Color Camera. 6 or 8 or 12mm (according to site suitability) with storage facility of at least 24-hour video recording, in elegant metal Die cast housing. Outdoor weather resistant IP 66, for monitoring the gates operation at Barrage & head regulators complete as per Technical Specifications.
Supply of Pan Tilt Zoom (PTZ) 36 X Optical and 12 X Digital Zoom; 2 Mega Pixel IP based (DIGITAL) camera, 500 meter. Night Vision (Multiple Intelligent Array system) in IP66 Weather Resistant Outdoor Metallic Housing. Outdoor weather resistant IP 66 including cabling required for monitoring. As per technical specifications.
Supply of Water Level transmitter non-contact RADAR type having 30m range for measuring Barrage pond level including all necessary cabling with suitable conduits & electrical fittings & mast complete as per technical specifications.
Supply of Water Level transmitter non-contact Ultrasonic type having 10m range for measuring downstream discharge of head regulator of main canal, including all necessary cabling with suitable conduits & electrical fittings & mast complete as per technical specifications.
Supply of solar panel, charger regulator, batteries, lightening arrestor with all connectors, cables and conduit for cables for providing un interrupted power supply to each PLC/RTU and instrumentation system, as per technical specifications.
Supply & installation of Air conditioning system with requisite furniture, Renovation & Furnishing of existing Barrage Control Room for establishment of SCADA Control room long with necessary electrical fittings as per technical specification.
Supply of Early Streamer Emission (ESE) Lightning Arrestor (Protection radius 87 meter) with all necessary accessories as per technical specifications
BARRAGE CONTROL ROOM EQUIPMENT’S
Supply of Main PLC Controller system with firm ware based hot redundancy which shall include software development of PLC, Control Panel with front door opening cabinet, fitted with Power buses, MCBs & modem. All the Electrical fittings will be Industrial type. Including suitable switch mode power supply (SMPS), 12” or above display & interconnection with related PLC/RTU’s, complete as per technical specification.
Supply, engineering and development of customized SCADA software for complete System with life time licensed version as per technical specifications.
Supply of Master server which includes Server with server Rack and industrial grade monitor with USB, RS232/RS485, Ethernet Ports, OS Windows 8 or higher compatible to SCADA System complete as per technical specifications.
NETWORK VIDEO RECORDER (NVR) 32 Channel 1080 P Full HD, Real time Recording and Reviewing in Compression Format. With HDD along with dedicated sufficient Hard Drive to have memory of at least 30 days as per technical Specifications.
Supply of IT Hardware which includes required Static IP, Router with modem, Switch, firewall system and A3 color printer as per technical specifications.
supply of 75” LED Display/ Video wall/ DLP based System for monitoring of SCADA & surveillance system at Barrage Control Room as per technical specifications
Supply of laptops & 4G/3G internet dongle along with licensed version Client SCADA software for remote viewing & monitoring of Complete SCADA system as per technical specifications.
Supply of online 3 KVA UPS with Battery system for power back up of barrage control room equipment’s including all necessary cabling & electrical fittings complete as per the technical specifications
Supply of Diesel Generator Set 10.0 KVA with 04 Earth Pits for earthing along with accessories complete as per technical specifications.
LOCAL CONTROL SYSTEM FOR BARRAGE AND HEAD REGULATOR
Installation, testing & Commissioning of PLC/RTU system with software development of PLC/RTU, Control Panel with front door opening cabinet, fitted with Power buses, MCBs & modem. Suitable power supply to power up PLC/RTU panel, including 7 inches or above HMI display & Industrial type electrical fitting & cabling with suitable conduits complete for all related field instruments, as per technical specification.
Installation, testing & commissioning of Shaft Encoder based rotary position sensor with local Digital Display & Proximity limit switches type Gate Position Sensors for indication and monitoring of Spillway gates, Intake Gates, Silt flushing gates including cabling & integration with PLC/RTU as per technical specifications.
Installation, testing & commissioning of 3 Phase VFD Starter panel for each motor of Barrage gates which consists of VFD, S.P.P, MCB, OLR, Timer, Main Switches including cabling & Electronic Digital Indicator complete as per technical specifications.
Installation, testing and Commissioning & integration of LTE Surveillance IP based 3G/4G Bullet Camera with Sim Card Slot, 2 Mega Pixel 2 OR4 Array/ 72 LED Color Camera. 6 or 8 or 12mm (according to site suitability) with storage facility of at least 24-hour video recording, in elegant metal Die cast housing. Outdoor weather resistant IP 66, communication with NVR located at Barrage control room for monitoring the gates operation complete as per Technical Specifications.
Installation, Testing & Commissioning & integration with NVR Located at Barrage Control Room of Pan Tilt Zoom (PTZ) Cameras, 36 X Optical and 12 X Digital Zoom; 2 Mega Pixel IP (DIGITAL) Camera, 500 meter. Night Vision (Multiple Intelligent Array system) in IP66 Weather Resistant Outdoor Metallic Housing. Outdoor weather resistant IP 66 including cabling & conducting required for monitoring. As per technical specifications.
Installation, testing & Commissioning of Water Level transmitter non-contact RADAR type having 30 m range for measuring Barrage Pond level. Including all necessary cabling, conduits, electrical fitting & mast complete, as per technical specifications.
Installation, testing & Commissioning of Water Level transmitter non-contact ultrasonic type having 10 m range for measuring downstream water level/discharge of head regulator of main canal system. Including all necessary cabling, conduits, electrical fitting & mast complete, as per technical specifications.
Installation testing and commissioning of solar panel, charger regulator, batteries, lightening arrestor with all connectors, cables and conduit for cables for providing un interrupted power supply to Instrumentation system, as per technical specifications.
Installation, testing & Commissioning of Early Streamer Emission (ESE) Lightning Arrestor with all connectors, cabling and all required accessories etc. As per technical specifications
BARRAGE CONTROL ROOM EQUIPMENT’S
Installation, Testing & Commissioning of Main PLC Controller system with firm ware based hot redundancy which shall include software development of PLC, Control Panel with front door opening cabinet, fitted with Power buses, MCBs & modem. Including suitable switch mode power supply (SMPS), 12” or above display & cabling with Industrial grade type electrical fittings for related remote PLC/RTU’s, as per technical specification.
Installation, testing, Commissioning and development of customized SCADA software for complete System with life time licensed version as per technical specifications.
Installation, Testing & Commissioning of Master server with SCADA Software which includes Server with server Rack and industrial grade PC with USB, RS232/RS485, Ethernet Ports, OS Windows 8 or higher compatible to SCADA System complete as per technical specifications
Installation, testing & commissioning of NETWORK VIDEO RECORDER (NVR) 32 Channel 1080 P Full HD, Real time Recording and Reviewing in Compression Format with dedicated Hard Drive to have memory of at least 30 days as per technical Specifications.
Installation, Testing & Commissioning of IT Hardware which includes required Static IP, Router with modem, Switch, firewall system and A3 color printer as per technical specifications
Installation, testing and commissioning of 75” LED Display for monitoring of SCADA & surveillance system at Control Room as per technical specifications
Charges for high speed synchronous internet connection (min. 8 mbps upload and download speed) & Static IP for Four years.
Charges for High speed 4G/3G internet dongle for laptop with Client SCADA software for remote viewing & monitoring of system for Four years.
Installation, Testing & Commissioning of Online 3 KVA UPS with Battery system for power back up of Barrage control room equipment’s as per the technical specifications
Installation, Testing and Commissioning of Diesel Generator Set 10.0 KVA with 04 Earth Pits for earthing, Starter Panel, Energy meter & cabling Complete in all respects as per technical specifications.
Four Years Operation & Maintenance and Comprehensive Warranty for Adwa Barrage & head regulator SCADA based system as per Price schedule after final acceptance of SCADA & Surveillance system. This includes replacement of material & consumable as & when required at bidders’ cost. The cost of Communication for GPRS & SIM charges for data transmission, maintenance and other related charges. Minimum one Service Engineer shall be placed at Barrage Control room for Operation of SCADA & Surveillance system.
Training of the purchaser's personnel at the supplier’s plant and/or/onsite in assembly, start up, operation, maintenance and/or repair of the supplied goods. Course topics will include sensor calibration, PLC/RTU & SCADA configuration, data downloading, data retrieval, collection, Trouble shooting, processing maintenance requirements and procedure for equipment configuration, installation, site testing and commissioning including training kit containing course material in soft and hard copies.
Alpha Pacific Systems Pv. Ltd.
Yokogawa India Limited
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid