Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 2₹4.1 LAccepted-Finance | ₹4.1 L | 2 | Accepted-Finance Quoted Rates Accepted |
| 2 | 1₹4.2 LRejected-Finance J 219 LANE W 15 WESTERN AVENUE SAINIK FARMS NEW DELHI | ₹4.2 L | 1 | Rejected-Finance Quoted Rates Rejected |
| 3 | 3₹4.7 LRejected-Finance | ₹4.7 L | 3 | Rejected-Finance Quoted Rates Rejected |
| Sl No | Description | Qty | Unit | SMART FITNESS L1 | Syncotts International L2 | PASSION SPORTS L3 |
|---|---|---|---|---|---|---|
| 1.00Synthetic Tennis Surface | ||||||
| 1.01 | Synthetic court Nine layer with cushion minimum thick 3.5 mm
(Approved by ITF in category 3)
Category 3, Medium
1 coat of small rubber
1 coat of Acrylic Resurfacer
3 coats of large rubber granule cushion
2 coats of small rubber granule cushion
2 coats of Base clolor | 1 | Per Sq. fit | 69 ₹133 | 70 ₹135 | 77 ₹149 |
| 1.02 | Synthetic court Five layer with cushion minimum thick 2.5mm
(Approved by ITF in category 4)
Category 4, Medium Fast
1 coat of small rubber
2 coat of Acrylic Resurfacer
2 coats of Base Color | 1 | Per Sq. Fit | 49 ₹94 | 50 ₹96 | 55 ₹105 |
| 1.03 | Synthetic court Four layer without cushion minimum thick 1.5 mm
(Approved by ITF in category 5)
Category 5, Fast
1 coat small rubber
1 coat of Acrylic Resurfacer
2 coats of Base Color | 1 | Per Sq. Fit | 44 ₹86 | 45 ₹88 | 49 ₹95.50 |
Tender Value
₹1 Cr
EMD Value
₹3 L
Closing Date
22 Dec 2025, 4:00 pmClosed
DIRECTOR SPORTS AND YOUTH WELFARE
T T NAGAR STADIUM BHOPAL
E Tender for supply and installation of Tennis Synthetic Court Surface 2025FifthCall
2025_DSYW_468896_1
8941/DSYW/INFRA/2025
Open Tender
Miscellaneous Works
90 days
BHOPAL
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,000
₹3 L
Yes
6 May 2026
16 Dec 2025
23 Dec 2025
16 Dec 2025
22 Dec 2025
17 Dec 2025
Amount
Synthetic Tennis Surface
Synthetic court Nine layer with cushion minimum thick 3.5 mm (Approved by ITF in category 3) Category 3, Medium 1 coat of small rubber 1 coat of Acrylic Resurfacer 3 coats of large rubber granule cushion 2 coats of small rubber granule cushion 2 coats of Base clolor
Synthetic court Five layer with cushion minimum thick 2.5mm (Approved by ITF in category 4) Category 4, Medium Fast 1 coat of small rubber 2 coat of Acrylic Resurfacer 2 coats of Base Color
Synthetic court Four layer without cushion minimum thick 1.5 mm (Approved by ITF in category 5) Category 5, Fast 1 coat small rubber 1 coat of Acrylic Resurfacer 2 coats of Base Color
Description of Work / Item(s)
Amount
Part-II (Base Work)
Excavation and cutting of soil
Murum filling, rolling, creating a slope
WBM - 100 mm compacted
Anti termite and weedicite by rodding at 1 foot intervals
Asphalt - 2 layers Providing & Laying 30mm Premix carpet mix of 12 mm + 20 mm metal with BITUMAN M. 3.5% BY METALWEIGHT 80/100 GRADE) and rolling
Drain (9" × 9" - 4"thick wall )
Edge wall (1' × 1' ×360")
R.C.C.Drain Cover 17" wide and 3" thick length may be upto 2ft.
Tennis Pole and Net
Description of Work / Item(s)
Amount
Part-III (Lighting and Fencing)
Specification of Fencing System: The Architectural Panel 3D Fencing to a height of 3.10 Meters. Entrance door must be provided with a single pivot door of width 0.80 Meter. Fence Post: Fence post must be made by MS Tubular section of size: 80mmX40mm with specific weight of not less than 4.15 Kg per Meter. Mounting plate to hold 3D Panel Fence must be welded to the fence post and clamp along with M10 Alen Bolt to be used to fix the 3D Panel Fence with the post. The distance between 2 posts should not be more than 2.60 Meters. Base plate of 0.80 KG must be provided with each post for Base plate mounting system and for grouting system minimum 18% of the post length (with 2 stoppers welded at equal distance) should be grouted with suitable cement mixture. Fence Post must be coated with powder coating and a plastic top cap should be fixed on fence post. Architectural 3D Panel: Panel should be made with 8SWG Galvanized Wire with mesh Maximum opening of 200mmX50mm with minimum 3V Bends in each panel and should follow IS 4948: 2002. The height of each panel should not be more than 1.575 Meters. Each Panel must be coated with powder coating.
Light System “Factory made 114 mm (OD) X 6 mtr High x 1 Nos of Powder coated thick, vertical Lamp post. To install the light system the six poles (which are part of fence) should be extended by required height and lights will be installed on it. Lamp post should have arrangement for fixing MCB with metal cover at bottom of vertical post, Lamp bracket for fixing of 3 LED Light fitting as per Lux level, with 8 nos x 150W LED WH MB LED Floodlight fixture. , cable and electric Work Luminous flux (±10%) 30,000 lm Luminaire efficacy 120 lm/W Correlated Color Temperature 5700K ±355K Color Rendering Index >70 Maintenance of lumen output 5000 hrs. Operating Temperature Range -10C to +45C Beam Type 35 without the cost of incoming electric line as per the direction of the Engineer in charge.
Syncotts International (BID ID -1398056)
PASSION SPORTS (BID ID -1398723)
Syncotts International (BID ID -1398056)
PASSION SPORTS (BID ID -1398723)
Syncotts International (BID ID -1398056)
PASSION SPORTS (BID ID -1398723)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.06 MB
BOQ_551308.xls
BOQ • 0.33 MB
ETenderforTennisSyntheticCourtSerface2025FifthCall.pdf
Tender Documents • 0.17 MB
Download all tender documents and submit your bid