Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.7 LAccepted-AOC E 30 RAJIV NAGAR BEGUMPUR NEW DELHI 110086 | NEW DELHI | NEW DELHI | DELHI | 110086 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹41.8 L+₹1.9 L (4.83%)Rejected-Finance | L2 | Rejected-Finance Being Higher Bidder | |
| 3 | Rejected-Technical | - | Rejected-Technical Not enlisted in appropriate gatagory i.e b(i) |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
11 Aug 2022, 6:00 pmClosed
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
REPAIR/MAINTS OF INTERNAL/EXTERNAL ELECTRIFICATION SYSTEM, B/R WORKS AND OTHER CONNECTED WORKS, FIRE FIGHTING EQPT, WATER SUPPLY LINE, SUBMERSIBLE PUMP AT WATER SUPPLY INSTALLATION AT PRABUDDH VIHAR (PCDA) DEVIKHERA AND VIVEK VIHAR UNDER GE E/M LUCK
2022_MES_533195_2
GE/EM/LKO/EXT(ELECT)/T-36 OF 2022-2023
Open Tender
Civil Works
Item Rate
240 days
GE E/M Lucknow
As per NIT
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹80,000
Yes
26 Sept 2022
25 Jul 2022
13 Aug 2022
25 Jul 2022
11 Aug 2022
30 Jul 2022
Amount
Taking down chowkhats or frame n. exc. 1.5 Sqm each with shutters (with out taking off shutters from the frame) and taken as credit complete all as specified and directed.
Taking down chowkhats or frames with shutters without taking off shutter from the frames exc. 1.5 but n. exc 4 sqm each complete all as specified and directed.
Taking down shutter only n. exc 1.0 sqm each, complete all as specified and directed.
Taking down shutters of any description exc 1 sq.m and n exc 2 sq.m each complete all as specified and directed.
S & F IInd Class Hardwood (Sal) plain, solid, straight, chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed.
S&F mild steel work as in hold fasts and similar articles conforming to Fe-410-0 or Fe-310-0, complete all as specified and directed.
M&L PVC door frame of size 50mm x 47mm made out of 5mm plain colour pvc sheet reinforced with MS square tube, suppling & fixing in opening as per specificationn & drawing, complete all as specified and directed.
S &F factory made solid PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm with stuck inside with cut, complete all as specified and directed.
M&L glazed and skeleton shuitters 30m thick of 2nd class hard wood open rebated and prepared to receive glass, gauage etc(with sash bars) in door, window, ventilators are provided with sytle and rails edges of framing plain, chamfered or rounded fitted with cut, complete all as specified and directed.
S&F 35 mm thick factory made Flush shutters , solid core construction , with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S&F 100 mm size butt hinges extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed type B21, complete all as specified and directed.
S&F continuous (piona) hinges, mild steel bright finish or electrogalvanised 30mm wide, complete all as specified and directed.
S&F 200mm long aluminium anodised barrel tower bolts of extruded section and fixed, complete all as specified and directed.
S&F 125 mm extruded aluminium alloy handles, fabricated type, anodised, complete all as specified and directed.
S&F 250 mm aluminium alloy anodised sliding door bolt with hasp staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolt and sliding bolts of extruded section or cast aluminium alloy and fixed, complete all as specified and directed.
S&F galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm in steel window clips and wooden beading in wooden joinery complete all as specified and directed.
M&L for preparing of new previously untreated surfaces of wood or wood based material over 10 cm width or girth & applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
S&F in repair galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm in steel window clips and wooden beading in wooden joinery complete all as specified and directed.
Demoltion of brick work built in cement mortar complete all as specified and directed.
Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth for foundation,etc n.exc 10 sqm on plan and getting out in soft / loose soil complete all as specified and directed.
Returning filling in including spreading levelling, watering and well ramming in layers n exc 25 cm in soft/loose soil, complete all as specified and directed.
Removing excavated materials n exc 50 m and depositing where directed at a level n'exc. 1.5 m above the starting point, complete all as specified and directed.
M&L for PCC 1:4:8 type -D2 using 40mm graded stone aggregate in filling and mass concrete complete all as specified and directed.
M&L fly ash bricks, old size as per IS 1489 (Part I)-2002 buit in CM 1:6 straight or curved on plan exc. 6 M mean radius complete all as specified and directed.
M&L for RCC Jallies 1:2:4 type B0 set in CM1:4 including moulding, complete all as specified and directed.
M&L Mild steel TMT bars 10mm dia and over, cut to length bent to shape required including crancking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S&F for 6 to 8 mm TMT bar including cranking, bending, binding with M S annealed wire not less than 0.9 mm dia, complete all as specified and directed.
M&L for cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in coping,padding and bed block, wall through and the like including weathering slightly rounded or chamfered angles and throating including necessary form work, complete all as specified and directed.
M&L 75 mm thick cement concrete 1:3:6 type C2 (using 40 mm graded stone aggregate) as plinth protection and the like complete all as specified and directed.
Taking down cement plaster on brick wall, racking out joints hacking for key scrubbing down with water complete all as specified and directed.
M&L for rendering 10 mm thick on brick work/ concrete surfaces in cement mortar 1:6 on fair faces finished fair & even, complete all as specified and directed.
M&L for 15 mm thick rendering in CM 1:4 on fair faces of brick work surface finished even and fair without using extra cement, complete all as specified and directed. (Note : Integral WPC shall be measured and paid seprately )
Supply only integral WPC conforming to IS spcification quality, complete all as specified and directed.
M&L rendering 5 mm thick on concrete surfaces in ceiling , in cement and sand mortar 1:3 complete all as specified and directed.
M&L for preparing surfaces, plastered or unplastered new surfaces of ceiling and applying three coats white wash complete all as specified and directed.
Preparation of newly plastered surfaces and applying two coat of oil bound disemper over one coat of oil base primer all as specified on walls surface.Incl a coat of 3mm wall care putty, complete all as specified and directed.
M&L for complete removal existing treatment incl preparing unplastered old surfaced and distempering walls with two coats of oil bound distemper white or tinted over a coat primer on wall sufaces.Incl a coat of 2mm thick wall care putty, complete all as specified and directed.
M&L Preparation of newly plastered or unplastered surfaces of walls by brooming down and priming plastered and other surfaces with cement paint primer ( before application of cement base paint) including two coats of cement base paint complete all as specified and directed.
Preparation of old plastered or unplastered surfaces of walls by washing, rubbing down & stopping etc, and applying one coat of cement base paint of any tint/shade complete all as specified and directed.
Preparation of old painted surfaces of steel of any description, not otherwise described over 10 cm width or girth, including knotting and stopping and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L applying one coat of Apex ( Asian Paint) / Weather coat (Berger) over old painted surface including preparation of wall surface complete all as specified and directed.
Taking up or down steel tubing and connections , including cleaning for re-fixing or removal of store, 15 mm bore complete all as specified and directed.
Taking up or down steel tubing and connections , including cleaning for re-fixing or removal of store, 20 mm bore complete all as specified and directed.
S & F 15 mm nominal bore Mild steel galvanised water tubing , medium grade , with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed.
S & F 20 mm nominal bore Mild steel galvanised water tubing , medium grade , with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed.
Demolition of floor hearth or wall tiling including cement mortar bedding (But not backing) removeing serviceable tiles to store and rubbishoff the premishes, complete all as specified and directed.
M&L for non skid ceramic tiles of 7-8 mm (square or rectangular) area of each tile exceeding 0.11 sqm but n.exc 0.16 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles over and including 15mm thick screed in CM 1:6, complete all as specified and directed.
M&L Vitrified ceramic tiles 10mm thick (square/ractangular) Coloured polished tiles, area of each tile n.exc 0.38 sq m in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement and pigment to match over and including 15 mm thick screeding in CM 1:6, complete all as specified and directed.
M&L for glazed ceramic tiles in vertical surfaces 350 x 250 x 7 mm / 450 x 350 x 7 mm [thick] set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles over and including 10mm thick screed in CM 1:4, complete all as specified and directed.
Repairing of existing aluminium door double leaf including oiling and greasing of floor springs and making the door and shutter serviceable complete all as specified and directed. (Note :- Floor door springs where renewed shall be measured and paid separately under appropriate items.)
Supply & fixing in repair Double action floor spring hydraulically regu-lated made up of mini-mum 1.25 mm thick alu-minium alloy sheet foun-dation box,main body with stainless steel cover, governing pivot made of mild steel heavy duty fixed, complete all as specified and directed.
S&F in repairs Aluminium body ( extruded section ) body Door closer hydraulically regulated, designation No. 3 , universal type , suitable for door shutters 851 to 1000 mm in width and of weight between 61 to 80kg and fixed, complete all as specified and directed.
S&F in repair for 100 mm mild steel 4 lever mortice lock vertical type of size, complete all as specified and directed.
S&F Powder coated Aluminium sections ( conforming to IS) door frames with double leaf shutters complete duly fitted with neosprene rubber beading,heat absorbing glass panes 4.8 mm nominal thickness, Alu anodised with rubber shoe floor door stoppers- 2 Nos, 100mm aluminium hinges 4 Nos per shutter, Handle 2 Nos in each shutter, Aluminium tower 1 Nos in each shutter and necessary locking arrangement with mortice lock with duplicate key complete all as specified and directed.
S&F Powder coated Aluminium sections ( conforming to IS) door frames with single leaf shutters complete duly fitted with neosprene rubber beading,heat absorbing glass panes 4.8 mm nominal thickness, Alu anodised with rubber shoe floor door stoppers- 1 Nos, 100mm aluminium hinges 4 Nos per shutter, Handle 2 Nos in each shutter Aluminium tower 1 Nos in each shutter and necessary locking arrangement with mortice lock with duplicate key complete all as specified and directed.
S & F in repair for 150 mm floor door stopper of aluminium alloy body and tonge,anodised with hard drawn steel spring, complete all as specified and directed.
Hacking out old broken glass, any thickness, size, quality, or description, from frame nexc 1.5 Sqm each pane, complete all as specified and directed.
S&F for 3.0 mm thick sheet glass ordinary quality and glazing with oil putty nexc 0.5 Sqm each pane, complete all as specified and directed.
S&F for 3.0 mm thick figured glass ordinary quality and glazing with oil putty n.exc 0.5 Sqm each pane, complete all as specified and directed.
S&f for 4.8 mm thick sheet glass odinary qulity and glazing with neosprene beading n.exc 0.5 Sqm in each pane, complete all as specified and directed.
S&F in repairs Chromium plated fancy long body Bib taps with cup , cast copper alloy with crutch handle, screwed for 15 mm bore dia. iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repair cast iron floor trap with chromium plated grating including jointing to waste pipe wih cement mortar (75 mm bore of pipe), complete all as specified and directed.
S&F in repairs Brass chromium plated shower rose without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed.
S&F in repairs Chromium plated ,Concealed stop cock Reduced body ISI Marked, , cast copper alloy, screwed down for 15 mm bore dia. pipe, high pressure, with crutch handle , screwed externally both ends for unions etc. and fixed complete all as specified and directed.
S&F in repair CP Angle stop cock ( one way) long thread with wall flange , fancy type screwed down for 15 mm bore dia. pipe, high pressure, with crutch handle , screwed externally both ends for unions etc. and fixed complete all as specified and directed.
S&F in repairs Pillar taps, fancy type cast copper alloy , with capstan heads, chromium plated , screwed down for 15 mm bore pipe,high pressure , with or without l'ettered ' 'HOT' or 'COLD' with long screwed shanks and fly-nuts, screwed for iron pipe, complete all as specified and directed.
S&F in repairs CP Angle stop cock( two way) long thread with wall flange , screwed down for 15 mm bore dia. pipe, high pressure, with crutch handle , screwed externally both ends for unions etc. and fixed complete all as specified and directed.
S&F in repairs CP mild steel gratings suitable for 75/100 mm dia NT/ FT complete all as specified and directed.
S&F in repairs Chromium plated Brass Tubular towel rod, of 24" (60 cm long) complete all as specified and directed.
S&F in repair vitreous China wash down water closet pan (padestal pattern Water Closet Cat No.20012, white) , (excluding fixing bolts, flushing cistern and flush pipe) , including connection to drain ( or outgoing pipe) and to flushing pipe, etc, complete all as specified and directed.
S&F in repairs VC WHITE Squatting pan ,'Orissa' pattern size 580x440mm with integral footrests water closet) with 'P' or 'S' trap front or back inlet complete including lime concrete for bedding, connection to drain pipe and to flushing pipe , anti syphon, complete all as specified and directed.
S&F in repairs Low level flushing cistern, moulded from virgin poly propylene complete all as specified and directed.
Supply and fixing in repairs Plastic water closet seat, white, closed pattern with flat bottom , and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
S&F for fixed in repair brass CP Wall mixer complete all as specified and directed.
S&F for fixed in repair single lever brass CP basin mixer complete all as specified and directed.
S&F in repair toilet paper holder brass CP complete all as specified and directed.
S&F in repair health faucet brass CP with 15 mm dia flexible pipenot less than 900 mm long equivalent complete all as specified and directed.
S&F in repairs PTMT connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed.
S&F in repair vitreous china wash basin (WHB) , white , flat back, size 550mmx400mm including brackets, waste fittings , brass Chromium plated for glazed basins etc. with long screw shanks and fly nuts , flange end embedded in red lead cement , including cutting, complete all as specified and directed.
Supply only 32mm bore flexible pipe of PVC fixed to WHB/ urinals as waste pipe ( not less than 600mm) including PVC coupling complete all as specified and directed.
M&L in repairs 32 mm waste fittings , brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed.
S&F in repairs 32 mm bore flexible pipe of PVC fixed to WHB/ urinals as waste pipe ( not less than 600mm) including PVC coupling complete all as specified and directed.
S&F in repair Gun metal , globe or gate valves, with iron wheel head, screwed both ends for 20 mm bore dia. iron pipe and fixed complete all as specified and directed.
S&F Gun metal, in repair globe or gate valves, with iron wheel head, screwed both ends for 15 mm bore dia. iron pipe and fixed complete all as specified and directed.
S &F door seal with aluminium 20 x 1.5 mm strips with wool, complete all as specified and directed.
Taking down pipes (any sizes) incl all fittings, complete all as specified and directed.
S &F 110mm bore (SWR) pipe single socketed in any length with rubber ring joints,fixed to walls, complete all as specified and directed.
S&F 110mm bore PVC (SWR) junction single, (single Tee) equal or unequal with access door, complete all as specified and directed.
All as per item No 89 above but dia of 75mm
S&F 110mm bore PVC (SWR) vent cowl, complete all as specified and directed.
S&F 110mm bore PVC (SWR) bend of any radius, complete all as specified and directed.
All as per item No 92 above but dia of 75mm
S &F 110mm bore (SWR) pipe single socketed in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed.
All as per item No 94 above but dia of 75mm
Taking down existing PVC water tank capacity exc 500 & n.exc 1000 ltr and S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Pt I. capacity of tank 1000 litres complete all as specified and directed.
S&F Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball , suitable for 20 mm bore pipe, screwed for iron pipe and fixed. (Minimum weight 20mm-210gms) complete all as specified and directed.
S & F in repair of PVC coated drapery rod of 20mm dia, complete all as specified and directed.
S & F brass coated knob at both ends of drapery rod of 20mm dia, complete all as specified and directed.
Temporarily blocking of inlet of septic tanks/manhole with suitable wooden plugs/gunny bags and pumping/bailing out effluent and taking out/removing the accumulated sludge soil sewage/any other foreign/foul materials etc (solid/semisolid) from the septic tanks/manholes. complete and cleaning the septic tank/manholes with water by mechanically including taking out the blocking arrangements of inlet and making the system functional complete all as specified and directed. NOTE: (i) Depth of manhole/SOAK WELL/SEPTIC TANK exc 0.5 to 1.5M from below GL (ii) Size of tank upto water level shall be measured
Temporarily blocking of inlet of septic tanks/manhole with suitable wooden plugs/gunny bags and pumping/bailing out effluent and taking out/removing the accumulated sludge soil sewage/any other foreign/foul materials etc (solid/semisolid) from the septic tanks/manholes. complete and cleaning the septic tank/manholes with water by mechanically including taking out the blocking arrangements of inlet and making the system functional complete all as specified and directed. NOTE: (i) Depth of manhole/SOAK WELL/SEPTIC TANK exc 1.50M to 4.50M from below GL (ii) Size of tank upto water level shall be measured
Temporarily blocking of sewage line with suitable wooden plugs/gunny bags and cleaning the same by rod-ding and removing the sludge alongwith brick bats/stones/broken bottles/any other foreign materials etc complete and cleaning the sewage line with water by mechanilly as directed by EIC, and taking out the blocking arrangements of inlet and making the system functional for 150 mm bore size of pipe lines, complete all as specified and directed.
All as per item No 102 above but 200 mm bore
All as per item No 102 above but 250 mm bore
Preparation of old painted wood and wood based surfaces of any description, not otherwise described over 10 cm width or girth, including knotting and stopping and applying one coat of synthetic enamel paint complete all as specified and directed.
M & L for French polishing on surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler on old works with one or more coats complete all as specified and directed.
M & L for hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, welding etc., and similar work conforming to Fe-290 Gde E-165 fixed in repair, complete all as specified and directed.
M & L for Machine pressed precast conctete interlocking paver block with grey cement and pigment any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade over and including 40mm thick sand layer including filled interstices complete all as specified and directed.
M & L for cement concrete type D 2, 1:4:8 (40mm graded aggregate) 75 mm thick as in sub base of floor complete all as specified and directed.
S&F for 18/19mm thick Prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws and hinges to timber frame work or to brick wall complete all as specified and directed.
Cleaning and removing all scale and dirt etc from tanks and from mouths of circulating pipes etc exc 250 & n.exc 500 ltrs capacity and writing date of cleaning using synthetic enamel paint complete all as specified and directed.
Cleaning and removing all scale and dirt etc from tanks and from mouths of circulating pipes etc exc 4000 & n.exc 5000 ltrs capacity and writing date of cleaning using synthetic enamel paint complete all as specified and directed.
Taking down old unserviceable/deteriorated batten/PVC conduit point wiring aluminium/ copper from existing place i.e. light, fan, socket or power points complete with all unserviceable fittings such as switches, sockets,bell push , ceiling rose, pendants, Holders, etc and making good all disturbed surface to wall, floor etc by means of cement mortar (1 : 3) or plaster of Paris and to match / finish new surface as the existing surface either by using same colour distemper, Putty or white / colour wash complete all as specified and directed.
M & L for concealed point wiring One light /Fan/Bell point controlled by one switch 6/5 Amp one way single pole on wall and ceiling/roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic white / ivory PVC conduit medium grade ISI marked not less than 20 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and Bakelite laminated sheet 3mm thick ISI marked for fixing of switches / sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour surfaces complete all as specified and directed.
All as per item No 114 above but One 3 pin socket outlet 6/5 Amps controlled by one switch on the same board with other switches.
All as per item No 114 above but One 3 pin 6/5 Amp socket outlet controlled by one switch independent board.
All as per item No 114 above but One 3 pin 6/5 Amp socket outlet controlled by one switch independent board but below/ side the switch board of light point in same vertical / horzintal plane.
All as per item No 114 above but for power point wiring with 4.0 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead.
One 3/5 pin 15 Amp socket outlet controlled by one switch indep board but below/ side the switch board of light point in same vertical / Horzintal plane, complete all as specified and directed.
S&F switch piano flush type (ISI marked), single pole, one way 6 Amp, 240 Volts complete all as specified and as directed.
S&F switch piano flush type (ISI marked), single pole, one way 16/15 Amps, 240 Volts including complete all as specified and directed.
S&F socket outlet 3 pin, 6 Amp piano flush type including complete all as specified and directed.
S&F socket outlet, 2 in 1, 3/5 pin 6 / 16 Amp, piano flush type complete all as specified and directed.
S&F bell push 5/6 Amps SP flush type complete all as specified and directed.
S&F ceiling rose, surface bakelite, 65mm x 50mm, two to three terminals complete all as specified and directed.
S&F for batten angle lamp holder insulated body with back plate suitable for batten fittings including complete all as specified and directed.
S&F Ding dong sound door call bell electric AC 240 volt, 50 Hz ding dong type including taking down unserviceable complete all as specified and directed.
Supply & Fixing medium step type fan regulator 80 Watt, 240 Volt AC, socket size, medium step" ISI marked complete all as specified and directed.
M & L for sub main wiring in replacement of worn out aluminium conductor wire with two run of FR PVC insulated unsheathed flexible copper conductor (Multistrands), single core of size 6.0 Sqmm, 1100 Volts grade and one run of 4.00 Sqmm FR PVC insulated unsheathed as earth (In Green Colour), flexible copper conductor (Multistrands) for continuous earthing conforming to IS 694 with latest amendments and drawing in PVC rigid conduit , connecting incoming / outgoing electric connections by using required size copper lugs / thimbles and making good the disturbed surface to match with existing complete in all respect all as specified and directed. Note :- 1. Two run of single core cable with one run of contineous earth wire of copper conductor wire Flexible (Multistrand) of FR PVC insulated shall be measured and paid as one unit length. 2. PVC conduit pipe with fitting shall be measured and paid separately .
M & L for sub main wiring in replacement of worn out aluminium conductor wire with two run of FR PVC insulated unsheathed flexible copper conductor (Multistrands), single core of size 4.0 Sqmm, 1100 Volts grade and one run of 2.5 Sqmm FR PVC insulated unsheathed as earth (In Green Colour), flexible copper conductor (Multistrands) for continuous earthing conforming to IS 694 with latest amendments and including draw in PVC rigid conduit 25 mm dia , connecting incoming / outgoing electric connections by using required size copper lugs / thimbles and making good the disturbed surface to match with existing colour (distumber, Oil bound, Samosem etc ) complete in all respect all as specified and directed. Note :- 1. Two run of single core cable with one run of contineous earth wire of copper conductor wire flexible (Multistrand) of FR PVC insulated shall be measured and paid as one unit length 2. PVC conduit pipe with fitting shall be measured and paid separately .
S & F service connection with twin core 10 Sqmm 240 volt heavy duty un armured PVC insulated solid aluminium conductor cable served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than one metre apart including 4mm GI supporting wire of suitable size in replacement of old unseriveable conductor cable complete all as specified and directed.
S & F service connection with twin core 6 Sqmm 240 volt heavy duty un armured PVC insulated solid aluminium conductor cable served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than one metre apart including 4mm GI supporting wire of suitable size in replacement of old unseriveable conductor cable complete all as specified and directed.
Supply & Fixing in replacement of DB by SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 8 way complete all as specified and directed.
Supply & Fixing in replacement of DB by SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 12 way complete all as specified and directed.
Supply & Fixing in replacement of DB by TPN Distribution Box vertical, double door of protection grade IP 43 provn for 4 Pole MCCB frame upto 200 Amps , upto 50 KA breaking capacity as incomer in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of way, confirming to IS 13032 & 8623 including chasing/cutting of wall and concealed and making good as existing surface complete all as specified and directed.
Supply and fixing in repair of MCCB 125 Amps 16 KA with fixed thermal magnetic release frame 4pole complete all as specified and directed.
Supply and fixing in repair of MCCB 100 Amps 16 KA with fixed thermal magnetic release frame F2 optim 1.0 , 4pole complete all as specified and directed.
Supply & Fixing in repair MCB SPN, 5 to 40 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed.
Supply & Fixing in repair MCB SP, 06 to 40 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed.
S&F in repair MCB TPN, 63 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed.
S&F Wall mounted LED batten 18/20 Watt with 01 No LED tube rod, extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver including dismantling taking down unsv FTL fitting T8 type any type complete all as specified and directed.
S&F LED building security light 35 watt, 230V complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable, One GI medium grade suitable size dia bracket of total length 50 cm and fixed to wall with 2 Nos MS Clamp and fastener incl dismentling taking down unsv fitting any type complete all as specified and directed.
Supply and Fix LED lamp 10 watt, CDL, B-22 cap, (Pin type), 230V, PF-0.95 (min) incl dismentling taking out unsv CFL/LED Bulb, complete all as specified and directed.
Supply and Fix LED lamp 15 watt, CDL, B-22 cap, (Pin type), 230V, PF-0.95 (min) incl dismentling taking out unsv CFL/LED Bulb, complete all as specified and directed.
Supply in replacement and installed steel tubular swaged pole type 410 SP - 31 (9 mtr long) complete with MS base plate of size 300x300x6mm thick at bottom, welded at the centre with through hole of 14mm dia at a height of 300mm above the coping finial cap and painted with two coats of aluminium paint over a coat of red oxide primer with writing number including excavation upto required depth and PCC type C-2 1:3:6 (using 40mm graded) at bottom and PCC type B-1 1:2:4 (20mm graded) for mass filling and pole coping (60x60x30cm) and rendering of coping with 10mm thick in1:6 cement mortar complete all as specified and directed.
M & L for PCC 1:4:8 type D2 using stone aggregate of 40mm nominal size in foundation concrete for pole/strut complete all as specified and directed.
M & L for PCC 1:3:6 type C2 using stone aggregate of 40mm nominal size in foundation concrete for stays complete all as specified and directed.
M & L for PCC 1:3:6 type C1 using stone aggregate of 20mm nominal size in foundation concrete for coping of poles complete all as specified and directed.
S&F GI tubing 80mm bore light grade for cable protection on pole / trench incl dismentling taking down unserviceable one, complete all as specified and directed.
All as per item No 149 above but 40 mm
All as per item No 149 above but 50 mm
M&L for painting of steel tublar/rail pole 09/11 meter long with silver aluminium paint of two coat after preparing surface & Marking number on pole with black paint complete all as specified and directed.
Supply and fixing in replacement of 60 W LED Street light fitting having epoxy powder coated pressure die cast aluminium housing front cover with polycarbonate lens with silicon gasket, with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant.IP lens for better distribution and toughened glass fixed to housing with screws , street light should have IP 66 protection and impact resistance of IK 07 , Lumen efficiency of LED not less than 110>_ lumen per watt system efficency ,power factor >0.95, THD<10% at Full load CRI> 70% ,Street light should have built in potted DriverTHD, open circuit protection , over voltage protection , surge voltage protection 5KV in built & 10KV SPD , and provided with company LOGO ingraved on housing of the Street light complete including taking down of old UNSV fittings complete all as specified and directed. Note :-The contractor should take approval of techincal specification of luminaries and driver from department before procurement .
Supply and fixing in replacement of 90 W LED Street light fitting having epoxy powder coated pressure die cast aluminium housing front cover with polycarbonate lens with silicon gasket, with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant.IP lens for better distribution and toughened glass fixed to housing with screws , street light should have IP 66 protection and impact resistance of IK 07 , Lumen efficiency of LED not less than 110>_ lumen per watt system efficency ,power factor >0.95, THD<10% at Full load CRI> 70% ,Street light should have built in potted Driver THD, open circuit protection , over voltage protection , surge voltage protection 5KV in built & 10KV SPD , and provided with company LOGO ingraved on housing of the Street light complete including taking down of old UNSV fittings complete all as specified and directed. Note :-The contractor should take approval of techincal specification of luminaries and driver from department before procurement.
Supply and fixing in replacement of 45 W LED Street light fitting having epoxy powder coated pressure die cast aluminium housing front cover with polycarbonate lens, with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant.IP lens for better distribution . street light should have IP 66 protection and impact resistance of IK 07 , Lumen efficiency of LED not less than 100>_ lumen per watt system efficency ,power factor >0.95, THD<10% at Full load CRI> 70% ,Street light should have built in potted IP 66 electronic LED driver with APFC, lower THD, open circuit protection , over voltage protection , surge voltage protection 5KV in built & 10KV SPD , and provided with company LOGO ingraved on housing of the Street light complete including taking down of old UNSV fittings complete all as specified and directed. Note :-The contractor should take approval of techincal specification of luminaries and driver from department before procurement .
Supply and fixing in replacement of 120 W LED flood light fitting having epoxy powder coated pressure die cast aluminium housing front cover with polycarbonate lens with silicon gasket, with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant.IP lens for better distribution and toughened glass fixed to housing with screws , flood light should have IP 66 protection and impact resistance of IK 07 , Lumen efficiency of LED not less than 110>_ lumen per watt system efficency ,power factor >0.95, THD<10% at Full load CRI> 70% ,Street light should have built in potted IP 66 electronic LED potted driver with open circuit protection , over voltage protection , surge voltage protection 5KV in built & 10KV SPD and provided with company LOGO ingraved on housing of the flood light complete including taking down of old UNSV fittings complete all as specified and directed. Note :-The contractor should take approval of techincal specification of luminaries and driver from department before procurement
Supply and fixing bollard light 60 cm long 10 - 12 watt LED Bollard light having epoxy powder coated pressure die cast aluminium housing Light optic /Diffuser - High impact polycarbonate/Optic colour temprature 5700K CRi>70,THD<10% PF >.90 surge protection 4KV inbuilt ,Rated voltage and frequency 240 Volt,50 Hz street furniture with touch if aesthetic innovative design with uniformly lit diffuser at the upper portion acts a beacon of path guidance in a landsscape IP 65 environmental complete with foundation work nut,bolt and washer etc complete all as specified and directed.
S&F Post top energy saving 240V,50Hz AC, environmental friendly, aesthetically designed electronic constant current,IK07, having epoxy powder coated pressure die cast aluminium housing Top cover spun Al sheet powder coated,front cover Clear acrylic diffuser with indirect symmetrical light distributio, IP-65 luminaire with high power LED as light source of capacity 40 Watt, 5700K PF >0.9, THD<10% and light efficiency 85>_ ,CRI > 70,Surge protection 5KV incl dismentling taking down unsv fitting any type complete all as specified and directed.
Supply and fixing security light Bracket made out of galvanised steel light grade pipe of 40mm dia 1.5 mtr long bend to an angle of 120 degree with 02 Nos clamp made out of 50mm x 5mm flat iron and 06 sets of nuts, bolts and washers painting with two coats of synthetic enamel paint over a coat of red oxide primer including taking down complete all as specified and directed.
Supply and fixing street light junction box of suitable size for three phase cable connection outdoor type, weather proof, factory made out of PVC sheet 1.8mm thick with front side hinged opening having locking arrangement with nuts & bolts & arrangement for incoming and out going cable/wire complete comprising with the followings :- (a) Bus bar with four aluminium strips, 100 Amps capacity insulated with insulators, including colour coding strip, including PVC cable of suitable size from bus bar to MCB (b) MCB SPN 5 to 30 Amps - 01 No (c) Clamps made out of 40mm x 5mm flat iron duly welded with nuts & bolts including taking down complete all as specified and directed.
Supply and fixing Street light fitting electronic constant current drivers/PCB/electronic gear suitable for 45 to 90 Watt LED flood light/street light fitting as required at site or as per sample including taking out old unserviceable complete all as specified and directed.
Supply and fixing Street light fitting electronic constant current drivers/PCB/electronic gear suitable for 120 to 150 Watt LED flood light/street light fitting as required at site or as per sample including taking out old unserviceable complete all as specified and directed.
Supply and fixing Street light fitting electronic constant current drivers/PCB/electronic gear suitable for 200 Watt LED flood light/street light fitting as required at site or as per sample including taking out old unserviceable complete all as specified and directed.
M&L for 15mm dia galvanised iron, light grade, ISI marked, complete with all fittings fixed to pole with fixing arrangement including clamps, nut and bolts of suitable size complete all as specified and directed
S&F in repair PVC insulated, PVC sheathed twin flat core 1100 volts grade, 4 sqmm aluminium stranded conductor from OH conductor or from junction box to street/security light complete all as specified and directed.
S&F in repair 1100 volts grade heavy duty flat twin core cable PVC insulated with stranded aluminium conductor of size 16 sqmm and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension GI wire from pole to pole complete all as specified and directed.
Taking down and refixing after recify the defects carefully of ceiling fan any size and any sweep including replacement of blades, down rods fan for recognize defects except winding at site or deposit to store complete all as specified and directed.
Taking down and refixing after recify the defects carefully of exhaust fan any size and any sweep including replacement of blades, for recognize defects at site or deposit to store complete all as specified and directed.
M & L for overhauling of ceiling fan any Make and sweep including dismantling, cleaning internally and externally, oiling, greasing, checking of electric connections, replacement of worn out check nuts, split pins, nuts, bolts and washers, sockets rebber real, clamps and minor repairing works and items etc. reassembling and testing on completion complete all as specified and directed. Note :- Winding works will be taken seperatly
All as per item No 169 above but for exhaust fan/wall fan/fresh air fan etc
Painting of ceiling fan of any size sweep including blades and canopies with white enameled approved spray paints one coat after cleaning dust etc and Marking of MES No ceiling fan such as MES No, and height of letter 2.5 cm in figures including sign writing with black enameled paints complete all as specified and directed.
Painting of Exhaust fan of any size sweep including blades and canopies with white enameled approved spray paints one coat after cleaning dust etc and Marking of MES No Exhaust fan such as MES No, and height of letter 2.5 cm in figures including sign writing with black enameled paints complete all as specified and directed.
Removing the burnt copper winding of ceiling fan ,cleaning to cores and rewinding of ceiling fans with copper enameled wire of suitable size including film paper, sleaving and varnishing , 56” (1400mm) complete all as specified and directed.
All as per item No 173 above but exhaust fan 12” sweep(300 mm) dia complete
All as per item No 173 above but exhaust fan/ fresh air fan 9" (250mm) dia complete.
All as per item No 173 above but Wall fan 12'' /15" (300 mm/350 mm) dia complete
Renewal of ball bearing for 6201ZZ size where required and complete all as specified and directed. Make SKF/NBC :-
All as per item No 177 above but 6202ZZ
All as per item No 177 above but 6203ZZ
Replacement of condensor 2.5 MFD where required and directed for ceiling fan, complete all as specified and directed.
Replacement of condensor 4.00 MFD for exhaust fan where required and complete all as specified and directed.
Renewal of Gun metal bush where required as directed for ceiling fan or exhaust fan complete all as specified and directed.
Renewal of shaft suitable for any make of ceiling fans and exhaust fans complete all as specified and directed.
Replacement of existing ceiling fan down rod with medium grade galvanized iron/ stove enameled pipe 20mm / 15 mm dia including threading both side or MS conduit heavy duty including both end hole with clamp with rubber real and split pin cable entry hole and check nuts including 3 core copper conductor 23/76, PVC insulated wire complete complete all as specified and directed.
M & L for dry Sand cushioning in trenches for protection of cable including watering and consolidation complete all as specified and directed. Note: Punned thickness shall be considerd for measurment purpose
M & L for well burnt fly ash bricks, old size as per IS 1489 (Part I)-2002 laying in trenches perpendicular to axis of the cable complete all as specified and directed.
Boring/drilling (Horizontly) manually/mechanically under existing road max 10 M in depth) suitable for passing GI Tubing 40 to 100 mm bore complete all as specified and directed.
Supply, laying jointing and testing in replacement LT UG cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured IS 7098 marked, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sq mm 3.5 core, laid in trench/laid under floor or fixed naked with wall/on wall/in ducts/in GI pipes etc. with and includings MS Clamps, nuts,bolts,washers complete all as specified and directed. Note- Excavation and earth works,and sand cushioning,protection bricks/tiles/blocks and pipe shall be measured and paid seprately under given items.
All as per item No 188 above but size 35 sq mm 3.5 core
All as per item No 188 above but size 95 sq mm 3.5 core
All as per item No 188 above but size 70 sq mm 3.5 core
All as per item No 188 above but size 16 sq mm 4 core
All as per item No 188 above but size 10 sq mm 4 core
All as per item No 188 above but 10 sq mm 2 core
Supply and fix street light panel single phase up to 6 KW load with Astronomical digital timer and MCCB of capacity 32/TP and SPN 40 Amps fixed on wall /pole with clamps nut bolts including taking down complete all as specified and directed.
S&F GI tubing medium grade, ISI Marked conforming to IS 1239 Part-I 2004, 15mm bore with and including all fittings fixed and laid in trenches/floor/under culvert/road crossing etc, fixed as in repair including dismentling taking down old unserviceable one complete all as specified and directed. (Note: Exacavation and earhwork shall be measured and paid for separately.)
All as per item No 196 above but of size 20mm bore
All as per item No 196 above but of size 25mm bore
All as per item No 196 above but of size 40mm bore
All as per item No 196 above but of size 50mm bore
S&F Bronze gate valve for 15mm bore pipe, with iron wheel head, screwed both ends for iron pipe and fixed, ISI marked conforming to IS 778 : 1984, fixed as in repair including dismentling taking down old unserviceable one complete all as specified and directed.
All as per item No 201 above but of size 20mm bore
All as per item No 201 above but of size 25mm bore
All as per item No 201 above but of size 40mm bore
Supply and fix LED tube rod18/20 Watt 4 fit retro T5/T8 complete all as specified and directed.
M&L for earthing as per IS:3043 with galvanized steel earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized iron wire 4 mm dia (8 SWG) as earthing lead protected by GI pipe medium grade 15 mm bore for protection of GI earth wire and 20 mm dia GI pipe medium grade for watering with alternate layers of charcoal /coke and salt including all accessories like nut, bolts, reducer, nipple, wire meshed/screened funnel and making brick masonry finished chamber of internal size 300 mm x 300 mm x 300 mm with concrete base, covered with PCC cover which shall be embedded in the block masonry including excavation works, refilling, connected to main switch/MCB DB for feeding the electric supply to domestic quarters compete all as specified as shown in electricall plateNo. 3 of SSR Part-I and testing of earth resistance as required. Note : Earthing lead/G.I.Earth wire upto 7.5 metre length shall be deemed to be included in quoted unit rate beyond 7.5 metre, the same shall be measured and paid separately).
Supply and fix in replacement water heater (Geyser) storage type 25 Ltr capacity (5 Star BEE rating) including PVC connections 15mm dia for hot and cold water and 3 core copper cable with plug top 15 Amp AC 230 V fixing on existing wall complete all as specified and directed. Note:- Geyser will be fitted with fastners-04 Nos including bolts washers etc and making good disturbed surface.
Material and labour in replacement for Ceiling fan 230 Volts complete with regulator and accessories with 1200mm sweep complete all as specified and directed.
S&F in repair Cable jointing kit for 1100 V (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core 25 to 50 sqmm XLPE armoured aluminium conductor, complete all as specified and directed.
S&F in repair Cable jointing kit for 1100 V (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core 70 to 95 sqmm XLPE armoured aluminium conductor, complete all as specified and directed.
S&F in repair Cable jointing kit for 1100 V (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core 120 to 150 sqmm XLPE armoured aluminium conductor, complete all as specified and directed.
S&F in repair Cable jointing kit for 1100 V (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core 185 to 340 sqmm XLPE armoured aluminium conductor, complete all as specified and directed.
Disconnecting all existing electric connection from panel taking out unserviceable MCCB and cable from LT panel Board and supplt fixing connecting and testing of MCCB 63 Amps 3 pole 25 KA 415 Volt 50 Hz with spreader with suitable size of cable lugs/thimble complete including all electric connection with making good complete all as specified and directed.
Disconnecting all existing electric connection from panel taking out unserviceable MCCB and cable from LT panel Board and supplt fixing connecting and testing of MCCB 100 Amps 3 pole 25 KA 415 Volt 50 Hz with spreader with suitable size of cable lugs/thimble complete including all electric connection with making good complete all as specified and directed.
Disconnecting all existing electric connection from panel taking out unserviceable MCCB and cable from LT panel Board and supplt fixing connecting and testing of MCCB 125 Amps 3 pole 25 KA 415 Volt 50 Hz with spreader with suitable size of cable lugs/thimble complete including all electric connection with making good complete all as specified and directed.
Disconnecting all existing electric connection from panel taking out unserviceable MCCB and cable from LT panel Board and supplt fixing connecting and testing of MCCB 250 Amps 3 pole 25 KA 415 Volt 50 Hz with spreader with suitable size of cable lugs/thimble complete including all electric connection with making good complete all as specified and directed.
Disconnecting all existing electric connection from panel taking out unserviceable MCCB and cable from LT panel Board and supplt fixing connecting and testing of MCCB 400 Amps 3 pole 25 KA 415 Volt 50 Hz with spreader with suitable size of cable lugs/thimble complete including all electric connection with making good complete all as specified and directed.
Overhauling, Oiling, Greasing and servicing of Air blower of any capacity by Opening of all parts , suction air filter ,bush ,bearing , rotor ,drum , bearing of motor shaft ,Neck ring, coupling with studs between motor & air blower ,& all other parts and re-assemble the same after greasing , oiling complete all as specified and directed. ( Note : - ( i ) Parts renewed shall be measured and paid separately under appropriate items ) (ii) Overhauling and servicing of Air blower should be carried out by Auth company or dealer Which is specialist of above .)
Labour for taking out unserviceable raw non clog submersible type raw effluent sewage lifting Submersible pump set of capacity upto 10 HP of rating 3 phase 440 Volts supply from raw sewage collection sump of STP plant well upto 15 mtr depth at any location for overhauling, Oiling,Greasing and servicing of capacity up to 10 HP by Opening of all parts , bush ,bearing , rotor ,drum , bearing of motor shaft ,Neck ring, coupling with studs between motor & all other parts and re-assemble the same after greasing , oiling of and shifting the same to authorised workshop for repair , testing and re-installation/Re-fixing/lowering in the sewage sump complete all as specified and directed. ( Note : - ( i ) Parts renewed shall be measured and paid separately under appropriate items ) (ii) Overhauling and servicing of non clog submersible Pump should be carried out by Auth company or dealer Which is specialist of above .)
Attend the day to day complaint of non functing part to Air Blower , Air Blower Motor ,non clog submersible Pump, motor and all connected parts complete all as specified and directed. (Note : - ( i ) Parts renewed shall be measured and paid separately under appropriate items ) (ii) Complaint Should be attend immediately within two hrs & Rectified the same day at the earliest without effecting of service .)
M & L for Cleaning of sewage line, man holes, septic tanks and soakage wells by providing all tools & plants including bamboos, buckets, ropes etc. (Contractor provide 2 Nos safaiwala to get it sewage complaiants which is received day to day by sub division.Note : Any complaints which is not completed with two days from the date of issue of complaint, compensation will be charged Rs 400/- per day in addition to above. Every additonal day delay will be charged Rs 100/-.)
Material and labour for taking out the silt & foreign object , Cleaning & Removing sludge from course bar screen including all chamber of equilasation tank upto depth of maxium15 Mtr any capacity STP as per direction by EIC complete with tools and plants as required at site and safe disposed off at place not more than 1.5 KM away at such a place which is not determental to public health complete all as specified and directed. Note : Sludge will be measured and paid after pumping pf pumpable sewage water as required and rate for the same shall be included in the above item.
Material and labour for taking out the silt & foreign object ,Cleaning & Removing sludge from Fine bar screen ,Oil & Grease Chamber complete with all as specified & direction by EIC complete with tools and plants as required at site and safe disposed off at place not more than 1.5 KM away at such a place which is not determental to public health complete complete all as specified and directed. Note : Sludge will be measured and paid after pumping pf pumpable sewage water as required and rate for the same shall be included in the above item..
Material and labour for taking out the silt & foreign object ,Cleaning & Removing sludge from MBBR I & II Chamber complete with complete all as specified and directed.
Material and labour for taking out the silt & foreign object ,Cleaning & Removing sludge from Tube Setteler Chamber complete all as specified and directed.
Supply and fix Plastic Media MBBR (Media) as per existing size & specification of IS complete all as specified and directed.
Supply and fix in repair of bubble diffuser as per existing specified size complete all as specified and directed.
Supply and fix in repair Pac media in tube settler tank as per existing specified size complete all as specified and directed.
Replacement of filter media of sludge drying bed as per specification laid specification of IS , complete all as specified and directed.
Supply and fix in repair of distribution box at equilistion well complete all as specified and directed.
M & L for preparation replacement of MS gate of oil & Greece chamber and sludge drying bedas per existing specified size , complete all as specified and directed.
M & L for repair of old M S pipe/angles of any description in any width or girth for complete one STP and applying two coats of epoxy paint with one coat of primer complete all as specified and directed.
Supply and fix in repair of pressure gauge 0 to 7 Kg/cm2 complete all as specified and directed.
Material and Labour for taking out /dismantling of Air blower pump/Fire fitting motor / water supply motorset of rating 3 phase 440 Volts of capacity upto12.5 HP from plat at any location and shifting the same to contractor's workshop for repair and re-installation/refixing the same at its original site and testing complete all as specified and directed.
Cutting out the existing winding of the motor, opening of winding, re-winding of motor with same size of rewinding with super enamelled copper winding including tapping, varnishing, baking and furnishing with the insulating sleeve and making connection complete all as specified and directed.
Repairing of pump by re-threading of worn out studs holes and supply and fixing over size studs with nut and washer complete all as specified and directed.
Repairing of pump shaft by depositing metal on it by breazing, grinding and polishing to appropriate size of the shaft complete all as specified and directed.
Supply and fixing gun metal/stainless steel bush of pump shaft complete all as specified and directed.
Supply and fixing driven end bearing of blower shaft complete all as specified and directed.
Supply and fixing end bearing of blower shaft complete all as specified and directed.
Supply and fixing gland and packing complete all as specified and directed.
Supply and fixing coupling with studs between motor & air blower complete all as specified and directed.
Supply and fixing in replacement suction air filter complete all as specified and directed.
Supply and fixing in replacement of suction silencer complete all as specified and directed.
Supply and fixing Neck ring complete all as specified and directed.
Supply and fixing bearing of motor shaft complete all as specified and directed.
Material and Labour for taking out unserviceable/burnt raw non clog submersible type raw effluent sewage lifting Submersible pump set of capacity upto 10 HP of rating 3 phase 440 Volts supply from raw sewage collection sump of STP plant at any location and shifting the same to authorised workshop for repair and re-installation/Re-fixing/lowering in the sewage sump complete all as specified and directed. (Parts renewed shall be measured and paid separately under appropriate items) listed here below :-
Cutting out the existing winding of stator of submersible motor of any make and rewinding with water proof copper winding wire of appropriate guage as existing complete all as specified and directed.
Straightening of the slots of stator of submersible motor of any make, complete all as specified and directed.
Supply and fixing thrust bearing block complete of submersible pump of any make, complete all as specified and directed.
Supply and fixing gun metal bushes for submersible motor as per manufacturer's design and specification, complete all as specified and directed.
Supply and fixing sand guard of submersible motor, complete all as specified and directed.
Supply and fixing of bronze metal impellars, complete all as specified and directed.
Supply and fixing of shaft sleeve, complete all as specified and directed.
Supply and fixing of set of gasket and O-ring, complete all as specified and directed.
Supply and fixing of Mechanical seal motor end, complete all as specified and directed.
Supply and fixing of Mechanical seal pump end, complete all as specified and directed.
Supply and fixing deep groove ball bearing motor side, complete all as specified and directed.
Supply and fixing groove ball bearing pump side, complete all as specified and directed.
Supply and fixing pump casing, complete all as specified and directed.
Supply and fixing of intermediate casing, complete all as specified and directed.
Supply and fixing of bearing housing, complete all as specified and directed.
Supply and fixing of bearing cover, complete all as specified and directed.
Supply and fixing of shaft protection sleeve, complete all as specified and directed.
Supply and fixing of bowl, cast iron, complete all as specified and directed.
Supply and fixing of bearing sleeve complete all as specified and directed.
Supply and fixing of rotor complete all as specified and directed.
Supply and fixing of cable assembly, complete all as specified and directed.
Supply and fixing in replacement mild steel Nuts , bolt and washer ,hexagonal full threaded 12 mm dia 100 mm long complete all as specified and directed.
Supply & filling of new Gear Oil Grade G-90 for Air Blower complete all as specified and directed.
Supply and fixing in repairs air blower pulley as per sample complete all as specified and directed.
Strip opening of air blower and cleaning of air filters and air silencers with required material/liquid shop complete all as specified and directed.
Supply and fixing in repairs three phase DOL starter with single phase preventor, MCB TPN 32 Amps 'C' Series, Voltmeter, ammeter and indication piolet lamps for three phase i.e. R.Y.B, having provision for mauanl by pass and suitable for operating submersible pumps sets/blower motors upto 10 HP capacity complete all as specified and directed.
Supply & Fixing Flat type submersible cable PVC insulated and PVC sheathed conductor 10 Sqmm 3 core 1100 Volts grade, flat cable conforming to IS-694:1977 complete all as specified and directed.
Supply and fixing in repairs bi-metallic overload relay with single phasing protection of range 2.5 to 4 Amps of make - Siemens or any other specified make complete all as specified and directed.
Supply and fixing in repairs bi-metallic overload relay with single phasing protection of range 6 to 10 Amps of make - Siemens or any other specified make complete all as specified and directed.
Supply and fixing in repairs bi-metallic overload relay with single phasing protection of range 10 to 20 Amps of make - Siemens or any other specified make complete all as specified and directed.
Supply and fixing in repairs power contactor ML-3, 3 Phase, 415 Volts current carrying capacity 4 to 25 Amps, coil voltage 220 volts, 50 Hz of make L&T or equivalent of other specified make complete all as specified and directed.
Supply & Fixing in repairs MCB TPN 32 Amps, 440V AC 'C' series ISI Marked. complete all as specified and directed.
Supply and fix in repairs push button type illuminated actuators flush with neon lamp (Red Colour) & suitable for operation with 415Volts, AC complete all as specified and directed.
Supply and fix in repairs LED type piolet indicator lamps (green colour) with integral circuit suitable for operating at 240V, AC complete all as specified and directed.
Supply and fix in repairs LED type piolet indicator lamps (yellow colour) with integral circuit suitable for operating at 240V, AC complete all as specified and directed.
Supply and fix in repairs Single Phase preventor to prevent single phasing , reverse phasing wiring & testing complete all as specified and directed.
Supply & fix in repair Digital Ampere meter ISI Marked suitable for (0-400Amps) range three phase AC Supply, current ratio 150/5A. complete all as specified and directed.
Supply and fix in repairs Voltmeter moving coil type suitable for voltage range 0-500 Volts for three phase AC system. complete all as specified and directed.
MCCB 4 Pole, current rating 100 Amps, thermal & magnetic setting adjustable 70%-100% breaking capacity 25kA at 415V,50Hz complete all as specified and directed.
MCCB 4 Pole, current rating 160 Amps, thermal & magnetic setting adjustable 70%-100% breaking capacity 25kA at 415V,50Hz complete all as specified and directed.
M & L for earthing complete with GI earth plate 60cm x 60cm x 3 mm thick buried directly in ground/ earth pit not less than 2.25M below ground level with top edge of the plate not less than 1.5M below ground level connected to GI earth wire protected by GI pipe i.e. light grade 25 mm dia all as shown in electric plate No.5 of MES SSR Part I connected to earthing test point, testing complete including necessary earth pit PCC 1: 3: 6 chamber and 50mm thick PCC 1 : 2: 4 chamber cover and with 6mm dia mild steel re-enforcement of 10Cm C/L spacing both ways in lieu of CI cover refilling of soil etc complete all as specified and directed.
Supply, laying, jointing, testing and commissioning of Mild Steel pipes 15 mm dia, Medium grade in any length, conforming to IS:1239(I) with flanged ends including fittings (Bend, Elbow, Tee, etc) and laid in trenches/fixing on wall/floors including painting with two coats of synthetic enamel paint of existing tint/colour complete all as specified and directed.(Note- Rubber gasket joints shall be measured and paid separately)
All as per item No 290 above but 25 mm dia
All as per item No 290 above but 40 mm dia
All as per item No 290 above but 50 mm dia
All as per item No 290 above but 80 mm dia
All as per item No 290 above but 100 mm dia.
All as per item No 290 above but 150 mm bore
Material and labour for Rubber or fibre board gasket joint 3mm thick (packing ring), including provision of suitable size bolts, nuts & washers for 80 mm bore pipe, complete all as specified and directed.
All as per item No 297 above but 100 mm bore
All as per item No 297 above but 150 mm bore
All as per item No 297 above but 200 mm bore
Supply and fixing in repairs Brass Handle valve suitable for 25 mm dia (wafer type) lever operated class PN-1.0, S.S-304 Disc, Nitrile/EPDM rubber lining including making new flanged joint with 3mm thick rubber gasket (Packing ring) with necessary bolt, nuts and washer complete all as specified and directed. Make : Zoloto/Kirloskar
All as per item No 301 above but 32 mm dia
All as per item No 301 above but 50 mm dia
All as per item No 301 above but 80 mm dia
Supply and fixing in repairs non return valve , CI of required dia 100 mm complete all as specified and directed.
M & L for construction of valves pit chamber using PCC (1:4:8) 40 mm graded stone aggregate for foundation 15 cm thick, 23 cm thick wall in CM (1:4) 10 mm thick rendering all around the brick work with 1:6 cement mortar PCC (1:2:4) type B1 coping with 20 mm graded agregate for grouting MS frame including 4 mm thick MS top sheet cover with locking arrangement including 50 mm pad lock with double key arrangement, MS frame out of 40 x 40 x 5 mm thick angle iron including paintaing of steel surface with two coats of synthetic enamel paint over a coat of red oxide primers finishing coat including necessary excavation in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs all as specified and including demolition/dismantling of existing cracked valve chamber of 900 mm x 900 mm x 900 mm complete all as specified and directed.
All as per item No 306 above but 1200 mm x 1200 mm x 1000 mm
Supply and fixing in repairs pressure guage analog type suitable for pressure range 0 to 10 Kg/Cm2 complete all as specified and directed.
S & Fixing Hose pipe for fire fiting of 100 MM complete all as specified and directed.
Labour only for grass/bushes cutting and complete cleaning surrounding the pump houses/water supply installatiions at different locations in cantt area in entire period for periodicity of atleast one time in every month to each installation complete all as specified and directed. Note :- Cutting of grass/bushes shall be done at least once in a month for each installation and shall be measured one time only for payment purpose in entire contract period.
Supply of liquid clorine sodium hypochlorite ( Grade - I ) drinking water with 9 % clorine contents by volume confirming to IS-11673 in seald non chemicale re-actined / oxidation LDPE Container of 40 Kg PVC tank with manufacture clorine test certificate and manufacture date mark not more than 02 week ago as required on monthly basis complete all as specified and directed. Note :- The Contractor shall arrange for independent testing for clorine contents from any Govt analysist / CHCC lab / Lan Nigam at own cost and shall be produced along with their claim for Payment .
M/S Nav Jyoti Enterprises
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .