Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹83,483.18Admitted-Finance | L1 | Admitted-Finance | ||
| 2 | L2₹87,881.54+₹4,398.36 (5.27%)Admitted-Finance | L2 | Admitted-Finance | ||
| 3 | L3₹88,341.71+₹4,858.53 (5.82%)Admitted-Finance | L3 | Admitted-Finance | ||
| 4 | L4₹96,314.40+₹12,831.22 (15.4%)Admitted-Finance | L4 | Admitted-Finance | ||
| 5 | L5₹98,658.05+₹15,174.87 (18.2%)Admitted-Finance GRAM RAKSHAWARA THANA KARARI TAH MANJHANPUR KAUSHAMBI | KAUSHAMBI | UTTAR PRADESH | 212201 | L5 | Admitted-Finance |
Tender Value
₹2 Cr
EMD Value
₹4 L
Closing Date
26 Feb 2026, 6:00 pmClosed
EE PHED DN Hanumangarh
EE PHED DN Hanumangarh
Rate Contract of Providing, Laying and Jointing pipe line and Replacement of old defective and polluted pipe line under division Hanumangarh
2026_PHCJA_536114_5
EE/PHED/HMH/202526/89-94
Open Tender
Civil Works
Percentage
330 days
EE PHED Division Hanumangarh
As per tender documents
2 documents required · 2 mandatory
₹1,000
EE PHED DN Hanumangarh
₹4 L
Yes
EE PHED DN Hanumangarh
13 Mar 2026
9 Feb 2026
27 Feb 2026
9 Feb 2026
26 Feb 2026
9 Feb 2026
15 Feb 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Rate Contract of Providing, Laying & Jointing pipe line and Replacement of old defective & polluted pipe line under division Hanumangarh (amount 200.00 Lac) | |||||
| 1.01 | Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-7 grade S&S pipes as per IS:8329-2000 (amended up to date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work)
Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. | - | - | - | - |
| 1.02 | 200 mm | - | RMT | 2,554 | - |
| 1.03 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.:
All kinds of soil | - | cum | 200 | - |
| 1.04 | Dismantling of cement concrete pavement for pipe line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work. | - | Cum | 757 | - |
| 1.05 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size). | - | Cum | 4,624 | - |
| 1.06 | Removing & Re-fixing of Precast concrete interlocking blocks for laying of pipe line by manual method, stacking of serviceable & non serviceable material separately, disposal of dismantled material lead up to 50 mtr. The C.C. interlocking paving blocks be laid on average 25 mm thick bed of coarse sand and the joints to be filled with fine sand. Laying procedure on compacted sub base as defined. Complete job is to be executed as per the directions of Engineer in charge. The rates to be inclusive of fixing of 70 percent reusable precast concrete interlocking block and cost of required new precast concrete interlocking block against damaged, including all lead and lift as per Technical specifications. (Interlocking block manufactured by fully computerized automatic stationery hydraulic vibro pressed machine & full computerized automatic batching plant of class A-1 as per BS:6717-2001. Tensile splitting strength and breaking load as per BS: 6717-2001 Colour: Grey cement natural colour. Variation in Dimension : Less than 1.6 mm Variation in thickness: Less than 3.2 mm) 80mm thick
Note: If existing precast block used more than 70%, than for every 1% use above 70%, deduction of 1% in cost shall be done for every 1% use above 70%. | - | sqm | 298 | - |
| 1.07 | Providing, lowering, laying, aligning, fixing in position at all level/ depths CI Class - B specials as per IS : 1538, amended up to date in trenches complete including all material, labour, testing and commissioning along with pipe line/ appurtenance as per Technical Specifications and as per direction of Engineer.
Note : E/w to be measured and paid separately. Plain ended CI specials including tail piece, spigot end and socket end. Up to 300 mm dia | - | Kg | 111 | - |
| 1.08 | Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths DI standard specials with rubber ring (EPDM)/ nut bolt and insertion sheet and jointing as per IS: 9523-2000 or as amended up to date, such as tees, bends, tapers, caps etc. within trenches in DI pipe line complete including all material, labour, taxes, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge (excluding earth work). All End Flanged Up to 300 mm Diameter | - | Kg | 158 | - |
| 1.09 | Work of Inter Connection in CI/DI/MS pipe line up to 1.5 mtr depth by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site, cutting of existing pipeline, jointing of Tee (complete) and other specials to make inter connection repair leak proof and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers for entire job contractor will use his own T&P & labour and will arrange transportation of material required from store. (Material such as Tee/ Tee Clamp/rubber sheet/ CID joints required for inter connection shall be provided by the department free of cost).In all type Soil | - | - | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
BID_doc.pdf
Tender Documents • 0.96 MB
BOQ_956751.xls
BOQ • 0.32 MB
Work_description.pdf
Tender Documents • 0.82 MB
ITT_GCCA_SCC.pdf
Tender Documents • 2.48 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .