| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.3 CrAccepted-Finance | ₹4.3 Cr | L1 | Accepted-Finance M/s Sahai has agreed to work in price Rs 42902915 |
| 2 | L3₹4.6 Cr+₹28.2 L (6.58%)Accepted-Finance | ₹4.6 Cr+₹28.2 L (6.58%) | L3 | Accepted-Finance documents ok |
| 3 | L4₹5.2 Cr+₹93.3 L (21.8%)Accepted-Finance | ₹5.2 Cr+₹93.3 L (21.8%) | L4 | Accepted-Finance documents ok |
| 4 | L5₹5.4 Cr+₹1.1 Cr (26.8%)Accepted-Finance | ₹5.4 Cr+₹1.1 Cr (26.8%) | L5 | Accepted-Finance Documents ok |
| 5 | L6₹5.8 Cr+₹1.5 Cr (35.1%)Accepted-Finance | ₹5.8 Cr+₹1.5 Cr (35.1%) | L6 | Accepted-Finance documents ok |
Tender Value
₹4.9 Cr
EMD Value
₹9.8 L
Closing Date
5 Aug 2020, 4:00 pmClosed
DIRECTOR NISER
DIRECTORATE NISER
Interior Airconditioning Firefighting CCTV Wi-fi and Electrical works for Auditorium NISER Jatni Odisha
2020_NISER_571286_1
NISER/ IWD-Civil/Acad/2019-20/27
Open Tender
Civil Works
Works
105 days
NISER JATNI
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹9.8 L
26 Aug 2020
14 Jul 2020
6 Aug 2020
14 Jul 2020
5 Aug 2020
14 Jul 2020
INTERIOR STRUCTURAL STEEL WORKS: The cost of following are deemed to have been included in the rate and to be read along with items: 1) The items given below shall be as per "Structural Steel Work" of the specifications. 2) All structural steel for insert plates, sleeves, etc shall be Hot Dipped galvanized confirming to IS:4759. 3) The rate should include necessary machine grinding, smoothening of the member/joints where-ever directed by the Engineer-In-Charge. 4) The rate should include the erection, machinery, equipments, temporary supporting structure and members required for the erection etc. complete including necessary precaution. 5) All the shop drawing required for the execution shall be submitted by the contractor in consultation with design consultant/architects including erection, construction methodology and work will start only after the approval of the same by Engineer-In-Charge. 6) Stainless steel shall conform to ASTM A 312 TP34 & ANSI B 36.19 E Schedule 5 S grade 304, Nickel @ 8 to 10.5% chromium at 18 to 20% unless otherwise mentioned.
Providing and fabricating structural steel work for column , wall panelling , insert angles and plates with holdfasts, handrail, window grills, catwalk, proscenium structure, etc. and any other miscellaneous steel work fabricated from I-beams, channels, angles, plates as per detail design and drawings or as directed,including cutting fabrication,hoisting,erecting and fixing in position ,making rivetted/bolted/welded connection and surface preparation by mechanical cleaning & applying one coat of approved steel primer complete as directed by Engineer -in-charge.
Providing and fabricating structural steel work for column , wall panelling , insert angles and plates with holdfasts, handrail, window grills, catwalk, proscenium structure, etc. and any other miscellaneous steel work fabricated from hotfinished welded type tubes (square, rectangular, circular hollow tubes) as per detail design and drawings or as directed,including cutting fabrication,hoisting,erecting and fixing in position, making rivetted/bolted/welded connection and surface preparation by mechanical cleaning & applying one coat of approved steel primer complete as directed by Engineer -in-charge.
PAINTING AND POLISHING: The cost of followings are deemed to have been included in the rate and, to be read along with items: 1) The items given below shall be as per "Painting" of the specifications. 2) Rates for painting to plastered surfaces shall include the cost of approved proper primer treatment to new surface and ceilings prior to painting. Scaffolding at Contractor's cost, no holes in walls shall be allowed. 3) The rate for the items shall include the filling with cracks with approved crack filler as per manufacturer's specification, labour, materials scaffolding, watering if required, preparing the surface etc.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per direction of Engineer-in-Charge.
Providing and applying one coat of primer, synthetic enamel paint in two coats of approved colour and make, including scaffolding, preparing the surface by degreasing and removal of loose matter, levelling putty, etc. complete as directed by EIC.
Providing and applying one coat of primer & two coats of acrylic emulsion paint of approved quality colour and make to internal wall and ceiling including scaffolding preparing the surfaces, levelling putty, etc. complete as directed by EIC.
Finishing walls with Acrylic textured exterior paint of required shade : New work (Two or more coat applied @ 3.28 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) etc. complete as directed by EIC.
Providing and applying one coat of Primer & two coats of Premium acylic emulsion paint of approved colour and make, including scaffolding, cleaning, preparing surface, levelling, etc. complete as directed by EIC
Providing and applying Texture plaster with finishing with Purlina/ Rustic texture material (with texture material of Asian/Renava/ Nitco/ Temtex or equivalant company make) in 3 to 4 milimeter thickness on previously finished plastered surface including plaster Groove 6mm thick or Tape Grooves 35 to 45 mm thickness or as required in all postion with 2 coats of Acrylic textured exterior paint including preparing the surface scaffolding etc. complete as directed by EIC..
FLOORING & CLADDING: The cost of followings are deemed to have been included in the rate and, to be read along with items Note : 1) The items given below shall be as per "Flooring" of the specifications. 2) At least 6 samples for all finishing items of work, from different approved sources shall be submitted before starting the work for approval. Engineer -in -charge decision regarding the shade, quality and the source is final. All like materials of flooring, cladding, etc to be from same batch as per approved sample . 3) All exposed stone edges to be mirror polished. 4) The rate for flooring / cladding should be inclusive of bedding / back coat plaster as specified. Additional bedding / backcoat required for levelling on site not be measured separately for payment. 5) For all vertical cladding, an approved chemical adhesive for tiles as per manufacturer's instructions shall be used and the rates quoted shall be inclusive of the cost of this adhesive. 6) The rate shall include dense hacking of concrete surface required to be cladded. 7) Scaffolding for cladding shall be of self supporting type. Holes will not be allowed to be made in the masonry or RCC work for anchoring the scaffolding. 8) No separate payment will be made for providing and fixing, odd sized tiles of any shape and size to suit Architect's requirement. 9) Rate shall be inclusive of grouting material required of approved shade. 10) The Contractor shall provide suitable supports for supporting the cladding tiles and remove it only after the tiles have firmly adhered to its location. 11) Edges of cladding tiles fixed on the corners of the columns and walls should be polished as per directive of Engineer-in-charge, or as indicated in the drawings. 12) The maximum thickness of the paste prepared by using tile adhesive and applied on the wall and column surfaces should be as per manufacturers specification. 13) The contractors are required to study drawings carefully to understand fixing details of flooring, skirting, cladding etc, to keep required grooves between different finishes at door and window locations, flooring and skirting junction, wall and ceiling junction etc to match flush line i. e. vertical plane of wall and skirting etc. 14) Rate shall be inclusive of cost of scaffolding at all heights, grouting, curing, final polishing by non-slip wax polish and cleaning of surfaces. 15) A sample/ mock up of flooring, cladding, etc to be got approved from, Engineer-in-charge. 16) All additional grooves to be provided in vertical, horizontal and direction as shown in detailed drawings without any extra cost to department. 17) To make wall cladding surface and skirting surface flush, wall at skirting level shall be required to recess inside as per fixing details. The necessary recesses in RCC wall etc. shall be taken at the time of construction itself. 18) If any colour variation is noticed after fixing of cladding and flooring materials, contractor should replace the respective tiles/stones at no extra cost to mach the existing materials. 19) Machine cut tiles should be used where ever required or as directed by Engineer in charge. 20) The rate shall include protection of flooring with 125 micron thk plastic film till the work is completed and cleaning on completion.
Providing and fixing resilient wooden stage flooring consisting top layer of 94 mm (W) x 25mm thk superior grade knotfree , seasoned Teak wood planking (finished with 3 coats of matt french polish) with Tongue and groove joints in both directions , planks fixed with adhesive and blind nails on under layer of IS marked 25mm thk exterior grade phenol bonded particle board fixed on T.W joists ( runners) of correct size 63mm x 97 mm placed at 750mm c/c in one direction , at right angle , to the procenium line, corss battens of correct size 50 x 50 mm fixed to main runners at right angles at 450mm c/c extra runners to be provided at border edges of wooden flooring . Main T.W runners placed on 10mm thk and of size 150 x 100mm Neoprene rubber pads of approved (Type F3) etc. complete as directed by EIC.
Providing & Fixing half round teak wood moulding on stage front of size 200 x 75 mm in curved shape as approved by Acoustic Consultant with sanding, leveling and 3 coats of matt french polish complete.Work will be carried out as per drg & instruction of Acoustic consultant /Site Engineer Incharge /Architect.
Providing & Fixing 25 mm thk superior grade knotfree , seasoned Teak wood treads for stage steps (One piece) on hard wood frame / joist as per drawing & instructions stated below. Step plank shall have 300 x 25 mm thk with required length at site (1500 max) plank shall be fixed on necessary hard wood frame. If require on concrete step by screw. Applying three coats of Matt finishing French polish on wooden step complete machine sanding (before fixing) and leveling. Applying hard putty, filling gaps etc including internal surfaces of frame & Plank shall be treated with anti - termite treatment with Termiseal (RTU) or approved equivalent complete with leveling, sanding etc. Work will be carried out as per drg & instruction of Acoustic consultant /Site Engineer Incharge /Architect. Plank Size :-900mm Average in length
Providing & Fixing 18mm thk superior grade knotfree , seasoned Teak wood riser (one piece) on hard wood frame as per drg and instructions stated below. Riser plank shall have 150x18 mm thk with require length at site (Say 1500 mm max.) Plank shall be fixed on necessary hard wood frame (if require on concrete by screw) Applying three coats of Matt finished French polish on wooden step complete machine sanding (before fixing) & leveling. Applying hard putty, filling gaps etc including internal surfaces of saalwood & Plank shall be treated with anti - termite treatment with Termiseal (RTU) or approved equivalent complete with leveling, sanding etc. Work will be carried out as per drg & instruction of Acoustic consultant /Site Engineer Incharge /Architect. Riser Size :- 900 mm Average In length
DOORS , WINDOWS: The cost of followings are deemed to have been included in the rate and, to be read along with items. 1) The items given below shall be as per :"Carpentry and Joinery, Aluminum Doors Windows ,skylight, structural cladding. 2) For all aluminum works, the contractor shall submit shop drawing for each item of work indicating the section of aluminum, its weight and joinery detail as per IS 1081, & IS 1948 and total weight of window/door/partition walls etc. Wherever possible riveting shall be resorted to for connection. Alternatively hot dipped galvanized pinheaded sheet metal/brass, screws could be used. No mild steel without hot dipped galvanized shall be used for any fastenings, etc. 3) The rates shall be paid for Aluminum sections only, used on weight basis and fixtures such as screws, hinges, handle, tower bolts, hold fasts, locks and brackets of any type shall not be weighed for the payments. This mode of payments applicable wherever aluminium is to be paid on weight basis. The rate of item of providing glass panels includes cost of all types of fixtures and fastenings made of any materials, neoprene rubber gaskets, screws, etc. 4) Contractor shall submit samples of assemble sections from different manufacturer's for approval, Engineer-in-charge decision shall be final. 5) All work between civil work and aluminum frames shall be sealed and made air tight by applying external structural grade Silicone sealant of approved make at contractor's cost. 6) The work of curtain walls/structural glazing/polycarbonate shall be carried out through specialized agency approved by Engineer-in-charge. Contractor should submit the design and drawing for the Consultant's approval for all detailed engineering work ,showing sizes of member including fixidity details etc. 7) Thickness of galvanising should be 125 microns. 8) Contractor should take necessary precautions against Galvanic corrosion when combination different type metals are used at site for particular item.
DOOR FRAME : Providing wood work in frames of doors, windows, clear storey windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length. in second class teak wood etc. complete as directed by EIC.
Providing & Fixing 125 mm thk Acoustical fire rated door for Auditorium, shutter finished with 4mm thk veneer on both sides Frame:Door shall be made in saalwood frame in 75 x 37.5mm frame all round as shown & 50 x 37.5mm intermediate frame 600mm c/c vertically. Frame shall have both sides 12mm thk fire rated ply finish with 4mm thk Veneer including 3 coats of melamine polish on veneer surface complete with machine sanding etc.Micron of 50 mm thk 1000 gsm density shall be kept in between wooden frame. Door shutter to have two rebates having thin felt lining for making air tight door and drop seal at bottom of shutter. Fixing 1 layer of 5mm thk Tecsound insulation and 1 layer of 12.5mm thk plain Gypsum board in between two frames complete. Work will be carried out as per drg & instruction of Acoustic consultant /Site Engineer Incharge /Architect. Size of door - 1800 x 2100 mm height (including frame) Basic Rate of Laminate - 450/sq.mt. SHUTTER: The shutter shall have double rebates on vertical and top edges with provision for EPDM doorseal fixing in one rebate and intumescent smoke stop strip fixing in second rebate.The shutter shall have have provision for fixing automatic mechanical drop seal at bottom edges. DOOR FITTINGS: INTUMESCENT STRIP- 1no per shutter,proprietary shielded intumescent smoke stop strip in one rebate on three edges except the bottom.SILICON DOORSEALS - 1no per shutter in 1 rebate on 3 edges except the bottom as approved (14rmt/door)HINGES - 100x 150 x 6 stainless steel Hinges as approved 4nos per shutter.HANDLES - Stainless Steel handle as per design approved, 2 nos per shutter,stainless steel (304 grade)hairline finish,40mm diameter,750 mm long on pull side of the Auditorium doors. 2 pairs per door. DOOR CLOSER – a) IR – LCN - 3133 Concealed heavy-duty door closer, 1 no per shutter., hold open type door closer or equivalent. AUTOMATIC DOOR BOTTOM – HAGER Automatic door bottom 740 ‘S’ as per the requirement. 1no per shutter at the bottom edge.2 Nos per door. Panic Device - Dorma PHA 2000 Push Type Panic Bar for Double Rebated Door or equivalent. 1) On active leaf: PHA 2105- Single point locking, modular, for fire and smoke doors with a door width up to 1300mm, with security anti thrust latch and dogging device. Steel latch, steel latch keep with spacer.2) On inactive leaf: PHB 2202 – Top and bottom lock combination, for fire & smoke check doors, with security anti thrust latch. Steel latch, steel top latch keep with spacer plates, steel bottom latch keep.3) PHB 2203:- Connecting rod set with cover for door heights up to 2270 mm steel latch keep with spacer plates for double doors (without trim) 4) Key with lever handle for Panic Device Model: 3905
Providing and fixing 35 mm thick Flush door with 35 mm thick BWP Grade Flush Doors with Engineered Wood Filler (IS: 2202 – Part 1) finished with laminate with 65x150 T.W frame with heavy duty hinges , door closure ,S.S handles & locking hardware system as per drawing of approved quality etc.complete and as per instruction of Engineering-in-charge.
Providing, fabricating and fixing Single glazed aluminium anodised sliding windows 3 Sliding shutters in heavy duty 3 track frame with 5.5 mm thick glazing of saint Gobain or equivalent make fixing in position at all floors anodised of approved shade and colour finished aluminium work for windows, ventilators, louvers with extruded builtup standard sections of Jindal /Hindalco conforming IS: 733 & IS: 1285 fixing with dash fastners of required size, including filling up the gaps at junctions i.e. top, bottom & sides with required EPDM rubber / neoprene / polysulphide sealant etc. Aluminium section shall be smooth, rust free, straight and jointed mechanically wherever required, including cleat angle,alluminium snap beading for glazing / paneling, stainless steel screws all complete as per drawings & manufacturers specification and as directed by Engineer-in-charge. Contractor shall submit shop drawings for the same for approval of Architect/EIC etc.complete as directed." (Type W1)
OBSERVATION WINDOW: Providing & Fixing 3400 W x 900 mm Ht.Openable Observation Window (Control Room window) - FRAME : 230 x 50mm first quality teakwood window frame having 12mm thk clear toughned glass on Control room side as per drawing fixed in 100x15 teakwood beading with rubber gasket lining all round the glass to make air tight. Window frame to be melamine polish finish Work will be carried out as per drg & instruction of Acoustic consultant /Site Engineer Incharge /Architect.
Providing and fixing Fully Glazed Door Shutters with 12mm thick toughened glass fixed on patch fittings of PT standard patch fitting set includes top pivot, bottom patch PT 10, top patch PT 20, corner lock US 10 lock with EPC 60mm of appproved make and as per design and details given by the architect/ including accessories, pvc edging, floor spring-DORMA floor spring BTS 75 V ,SS handle-DORMA 316 SS TGDID 300X22S Satin,lock-EM3000AH etc. complete as directed.( Type D1)
Providing and Fixing trap Doors for accessing the services and utilities in BWR grade plywood 18mm thick with 6mm thick teak wood lipping all round, with 50 X 50mm thick salwood framework suspended from the ceiling, trap doors to be locked with Ellen Key locks with safety chain stay, finished and completed as per drawing and as directed by EIC.
Providing & fixing approved Frosted Film on glass as per design etc. complete as directed by EIC.
CARPENTARY WORKS: Note: 1. Providing cut outs, holes, slits, depression etc. for electrical, air-conditioning fixtures, panels etc. and applying solignum on timber frames surface in side the partitions, panelling shall not be paid separately. 2. All internal portion of furniture shall be done with french polish unless mentioned otherwise and shall be paid separately. 3. All furniture includes the cost of fittings, fixtures and hardware and shall not be paid separately. 4. The cost should be inclusive of providing pest control to the entire carpentry works and shall not be paid separately. 5. The partition shall be inclusive of 50 mm thick sound insulation of crown 100 type and shall not be paid separately. 6. All laminates shall be matt/satin finish type. 7. C.P. Teakwood should be of certified wood stamping. 8. Plywood should be of certified wood stamping VOC (Volatile Organic Compounds) content in sealants/adhesives limits as mentioned in table no.01. 9. Godrej or equivalent furniture should have recycled content as part of their material specifications and should be procured within 800 kms. 10. Gypsum board for false ceiling should have recycled contents. 11. LUXALON or equivalent should have recycled content in aluminum. 12. Metal supports for flooring should have recycled content as per permissible limits. 13. Wooden flooring should be of certified wood stamping. 14. Carpets to maintain CRI (Carpet and Rug Institute) standards and the VOC contents in carpets not to exceed 0.5 g/sq.m./hr. and adhesives used should not exceed VOC content as mentioned in table no.01.
Panelling - Lobby Walls : (P1) Providing and fixing wooden panelling in 12mm thick marine grade plywood, conforming to IS:710, and 4mm thick natural veneer as per pattern and with grooves as per design, finished with melamine polish, including framing in seasoned salwood battens 50x50 @ 400 mm c/c in vertical and horizontal direction, with anti termite treatment to the timber complete as per design and as directed by Engineering-in-charge.
Panelling - Type AP1: Supply & installation of "Anutone" Salon Slats Surco or equivalent, Salon Slats Surco made of pinewood E1 grade fiberboard, melamine laminated finish, groove perforated slats L16-2 - (2mm grooves @16mm pitch), backlined with Soundtexblack acoustical fleece of 0.27mm thick, surface density 63g/m2, tongue-groove edge for a seamless look, 5-test fire retardant grade/ Non FR, size 128x2440x16mm, volume density of base board 700Kg/m3, weight 9Kgs/m2 (L16), 10.5Kgs/m2 (L32), 11Kgs/m2 (L64) installed on framework erected by contrator. The system to be backlined with thermally bonded,chemically free acoustical infill of 25mm thk and1000GSM surface density, with following technical parameters - • Fire (Class) – 1 & P (For FR grade) • Acoustics – 0.75 • Green (VOC, RC %) – E1, 25 Framework should be erected by contractor so as to achieve desired profile as per architectural drawing. Strut CC18 aluminium core cross channel, thickness 0.5mm, length 2400mm, web 15mm & 27mm, depth 18mm and flanges of 7mm with suitable edge ¢re brackets is then fixed horizontally to the framework behind with the help of fasteners at every 400mm centers. Slats Surco of size 128x 2440x16mm in then fixed perpendicular to CC18 with suitable edge & centre brackets. Short edges of the panel are staggered. Contractor to provide expansion joints of 3mm at every 4.88m length wise and 4.992m width wise etc. complete as directed by EIC.
Panelling - Type AP2: Supply and installation of "Anutone" or equivalent, Strand Colour, square edge Magnesite bonded pinewood fibre core tiles of size 600x1200x20, density 400 kgs/m3, weight 8kg/m2 fastened on 18 mm thick marine grade plywood base with MS framework (MS work paid separately) as per designed profile etc. complete as directed by EIC. The system to be backlined with the acoustical infill Anutone SynthPF 10x25 with following technical parameters - • Fire (Class) – 1 & P • Acoustics – NRC 0.75 • Green (VOC, RC %) – Low, 30
Panelling - Type AP3: Providing and fixing wooden panelling in 12mm thick marine grade plywood, conforming to IS:710, and 6 mm thick "Corian" or equivalent solid PVC surface material, as per pattern and with triangular perforations as per design, including framing in seasoned salwood battens 50x50 @ 400 mm c/c in vertical and horizontal direction, with anti termite treatment to the timber complete as per design and as directed by Engineering-in-charge.
Panelling - Type AP4: Providing and fixing wooden panelling in 12mm thick marine grade plywood, to be finished in paint, conforming to IS:710, including framing in seasoned salwood battens 50x50 @ 400 mm c/c in vertical and horizontal direction, with anti termite treatment to the timber complete as per design and as directed by Engineering-in-charge.
Panelling - Type AP5: Providing and fixing mirror panelling in 12mm thick marine grade plywood, conforming to IS:710, with 5 to 6 mm thick mirror, as per pattern and with triangular perforations as per design, finished with melamine polish, including framing in seasoned salwood battens 50x50 @ 400 mm c/c in vertical and horizontal direction, with anti termite treatment to the timber complete as per design and as directed by Engineering-in-charge.
Stage Wall Panelling : (AP6) Supply and Installation of "ANUTONE" or equivalent, Mat Ebony, Kerfed edge, Magnesite bonded pinewood microfibre core pigmented ceiling tiles of size 600x1200x20mm, volume density 600Kgs/m3, weight 12kg/m2 installed by using Strut framework system with non-visible fasteners using Strut H-Spline. The system to be backlined with thermally bonded,chemically free acoustical infill of 50mm thk and1000GSM surface density, with following technical parameters • Fire (Class) – 1 & P • Acoustics – NRC 0.65 • Green (VOC, RC %) – Low, 35 Strut framework systems includes Strut CC50 Cross Channel having thickness 0.7mm, length 3600mm, knurled web 50, depth 50mm and equal flanges 15mm is fastened to wall positioned horizontally in a regular manner at 600mm c/c. Strut H-Spline having sectional thickness 2mm and length 2400mm to be fixed perpendicular to the Strut CC50 Cross Channel at 600mm centers. The Kerfed edge panels shall be then inserted into the Strut H-spline along their long edges of 1200mm against framework to perfect fit with staggered short edges etc. complete as directed by EIC.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing and fixing top hung movable wings of size 1.2mt X 6.0mt high with 50x50 mm salwood frame at 600mm c/c both ways , with 6mm ply with paint finish on one side and veneer on other including all hardware etc; complete as per drawing etc. complete as directed by EIC.
(Type - P2) Providing & Fixing Curtain housing 75 mm thk partition on salwood frame with both sides 12mm thk ply as per drg. FRAME : Treated saalwood frame of 50 x 50 mm at 600mm c/c in both directions in between frame have 50 mm thk 1000 gsm density Micron, Frame shall be covered by 12 mm thk ply with 2 coats of paint finish from both sides. Anti-termite treatment to the internal surfaces of wooden frame and back side of fire rated ply with Termiseal (RTU) or approved equivalent including scaffolding, leveling etc complete,Work will be carried out as per drg & instruction of Acoustic consultant / Site Engineer Incharge / Architect.
(Type - P3) - Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture's specification and direction of engineer in charge all complete. 66 mm overall thickness Partition with 8mm thick double skin Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process with Compressive Strength 225 kg/sq.cm, Bending Strength 100 kg./ sq.cm
FALSE CEILING:
(Type - C1) Providing and fixing acoustic insulation ceiling under roofing sheets with frame in G.I 'C' stud section 50x37.5x0.8mm thk @ 500mm c/c in one direction & 1000mm c/c in other direction with between frame have Mikron of 50 mm thk 1000 gsm density with Black tissue paper.Entire frame/Micron shall be covered with welded mesh of G.I 19 x19mm square of 14 guage(as per approved sample) including Micron tissue paper,machine instruction screw & levelling & scafolding etc work will be carried out as per drawing & as directed by EIC
Plain False Ceiling : (Type - C2) Supply and Installation of "ANUTONE" or equivalent, Pixel Smery perforated GFR gypsum panels, backlined with acoustical fleece and consisting of Pixel 3/8 panel, backlined with acoustical paper having 3x3mm square perforations @ 8.33mm pitch - 8 % open area, size 1200x2400x12.5mm tapered long edges, volume density of base board 700 Kgs/m3, weight 9Kgs/m2 finished with Smery acoustical paper, size 1000x25000x0.75mm and acrylic paint installed by using Strut ceiling framework. The system to be backlined with thermally bonded,chemically free acoustical infill of 25mm thk and1000GSM surface density. with the following technical parameters - • Fire (Class) – 1 & P • Acoustics – NRC 0.5 • Green (VOC, RC %) – Low, 25 Strut ceiling framework should be installed so as to achieve desired profile and design as per arch dwg.Framework system shall include Strut WC25 Wall channel, fully knurled, sectional thickness 0.55mm, length 3600mm, unequal flanges of 20 & 30mm and web of 25mm, fixed along the perimeters of the wall with nylon sleeves and suitable fasteners at every 300mm centers. Then suspend Strut MC45 Main channels, fully knurled, sectional thickness 0.8mm, length 3600mm, equal flanges of 15mm and web 45mm from the soffit at 1200mm centers with Strut SA25, fully knurled, Suspender angle with sectional thickness 0.55mm, unequal flanges of 25 & 10mm. Strut CC25 Cross channel, fully knurled, sectional thickness 0.55mm, length 3600mm, web 35mm, depth of 25mm and equal flanges 15mm is fastened to the Strut MC45 perpendicularly at 600mm centers for upto RH70, at 400mm centers for RH70-RH90 and at 300mm centers for >RH90. Pixel 3/8 panel is installed on the Strut CC25 with suitable fasteners at 600/400/300mm centres. The tapered long edges are then filled and finished with Seam AJC and tape. The short square edges are also similarly finished but no tape. Apply one coat of white primer with roller brush evenly across the Pixel surface to achieve uniform colour etc. complete as directed by EIC.
Perforated False Ceiling : (Type - C3) Supply and Installation of "ANUTONE" or equivalent, Ellipse Taper, perforated GFR gypsum panels, backlined with acoustical fleece having 4x14mm slotted perforations @ 10x20mm pitch - 15% open area, size 1200x2400x12.5mm tapered long edges, volume density of base board 700Kgs/m3, weight 9Kgs/m2 installed by using Strut ceiling framework. The system to be backlined with thermally bonded,chemically free acoustical infill of 25mm thk and1000GSM surface density. with the following technical parameters - • Fire (Class) – 1 & P • Acoustics – NRC upto 0.8 • Green (VOC, RC %) – Low, 25 Strut ceiling framework should be installed so as to achieve desired profile and design as per arch dwg.Framework system shall include Strut WC25 Wall channel, fully knurled, sectional thickness 0.55mm, length 3600mm, unequal flanges of 20 & 30mm and web of 25mm, fixed along the perimeters of the wall with nylon sleeves and suitable fasteners at every 300mm centers. Then suspend Strut MC45 Main channels, fully knurled, sectional thickness 0.8mm, length 3600mm, equal flanges of 15mm and web 45mm from the soffit at 1200mm centers with Strut SA25, fully knurled, Suspender angle with sectional thickness 0.55mm, unequal flanges of 25 & 10mm. Strut CC25 Cross channel, fully knurled, sectional thickness 0.55mm, length 3600mm, web 35mm, depth of 25mm and equal flanges 15mm is fastened to the Strut MC45 perpendicularly at 600mm centers for upto RH70, at 400mm centers for RH70-RH90 and at 300mm centers for >RH90. Ellipse Taper is installed on the Strut CC25 with suitable fasteners at 600/400/300mm centres. The tapered long edges are then filled and finished with Seam AJC and tape. The short square edges are also similarly finished but no tape. Apply one coat of white primer with roller brush evenly across the Pixel surface to achieve uniform colour etc. complete as directed by EIC.
Providing and fixing "KONARK WHEEL" mottiff in 12mm thick marine ply base and 6 mm thick ply sides as per design, modules to be assempled at floor level and lifted to position, to be finished in paint etc. complete as directed by EIC.
Stage False Ceiling : (Type - C4) Supply and Installation of "ANUTONE" or equivalent, Mat Ebony, square edge, Magnesite bonded pinewood microfibre core pigmented ceiling tiles of size 595x595x15mm, volume density 600Kgs/m3, weight 9kg/m2 which is suspended by using 0.3mm thick trelis T24 Ebony metal grid system. The system to be backlined with thermally bonded,chemically free acoustical infill of 50mm thk and1000GSM surface density. Technical Parameters - • Fire (Class) – 1 & P • Acoustics – NRC 0.9 (For 15mm E300* Mounting) • Green (VoC, RC %) – Low, 35 TrelisT24 metal grid system of 600x600mm module includes Skelet WA24B30 wall angle with equal flanges of 24mm, length 3000mm, fixed along the perimeter of walls with the help of nylon sleeves and suitable fasteners at 300mm centers. Then suspend the Skelet MT24B36 MainT with flange width 24mm, height 38mm and length 3600mm, from the soffit slab with help of soffit cleat and wire rod with leveling spring clip at 1200mm centres. Skelet CT24B12 CrossT with flange width 24mm, height 32mm and length 1200mm is interlocked into the pre-cut slots in the Main T24 at 600mm centers in the perpendicular direction to the Main T24. Finally Skelet CT24B06 CrossT with flange width 24mm, height 32mm and length 600mm are interlocked into the precut slots in the CT24B12 CrossT in direction parallel to the Main T24 to result in 600x600mm module.MAT Ebony square edge of size 595x595x15mm shall be placed into the grid size of 600x600mm etc. complete as directed by EIC.
Rehearsal Area & Green Room Ceiling : (Type - C5) Supply and Installation of "ANUTONE" or equivalent, Sisoli Savana, square edge, Mineral fibre core, square edge ceiling tiles of size 595x595x15mm having pin perforations with real sand texture finish having volume density 270 kgs/m3, weight 4kg/m2 which is suspended by using 0.3mm thick TrelisT24 metal grid system. The system to be backlined with thermally bonded,chemically free acoustical infill of 25mm thk and1000GSM surface density. Technical Parameters - • Fire (Class) – 1/A • Acoustics – NRC 0.6 (For E600 Mounting) • Green (VoC, RC%) – Low, 63 TrelisT24 metal grid system as per specifications above etc. complete as directed by EIC.
Electrical
Design, supply, installation, testing and commissioning of following miniature type circuit breaker type boards with minimum IP44 degree of protection made up for 16 SWG thcic MS CRCA sheet ,wall mounted (flush / surface) as per drawings and specifications and as required. The distribution board shall be of sheet steel enclosure powder coated with copper busbars suitable for single phase or three phase MCBs. The MCBDB shall have sheet steel hinged lockable door top to prevent access to MCBs from outside. The DB shall have suitable neutral and earth terminal block to facilitate easy termination of wires. All wires inside the DBs shall be terminated using copper end terminations with labelling of each outgoing circuits . All dbs shall be of double door type.Type test report from the OEM has to be produced along with the material. Make:- Legrand,Hager,L&T
12 Way TPN DB (4 +36) Double door
8 Way TPN DB (4 +24) Double door
6 Way TPN DB (4 +18) Double door
4 Way TPN DB (4 +18) Double door
12 Way SPN DB Double door
8 Way SPN DB Double door
Supplying and fixing following rating, four pole / Double pole, (three phase and neutral / Single Phase & neutral), 415 / 240 volts, RCBO,having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.Make:- Legrand,Hager,L&T
63A FP RCBO 100mA
40A FP RCBO 100mA
40A DP RCBO 100mA
25A DP RCBO 100mA
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Make:- Legrand,Hager,L&T
10A SP MCB
20A SP MCB
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.Make:- Legrand,Hager,L&T
63A FP Isolator
40A FP Isolator
Supplying and fixing FP sheet steel enclosure on surface/ recess with all accessories as required.Make:- Legrand,Hager,L&T
Supplying and fixing IP66 Floor boxes with cover recess in floor with all accessories as required.Make:- Legrand,Hager,L&T
Supply, laying, connection, testing and commissioning of heavy duty medium voltage cables 1100V grade as per Specification and IS 7098 PART I XLPE insulated and outer sheeth of FRLS and inner PVC sheeth stranded AL & CU conductor unless or otherwise specified. The cable shall be laid underground when laid outside the building in the method as specified and shall be laid in prepared trench / cable tray / duct when laid inside the building. The cable shall be laid to UPVC pipe at the entry of the building. The unit rate shall include Delivery of the cables at site.Shifting of cable from site store to place of installation.'Laying of cable in the prepared trench / cable tray / duct when laid inside the building or underground when laid outside the building.Excavation in hard or soft murrem / rocky area upto required depth, supply and laying of protection bricks, supply and backfilling with fine sand, leveling the ground to match with the existing condition 'Supply and fixing of cable clamps, brackets, supports, route markers etc as required for cable tray, duct. Earthing the glands and armouring with earthing clamp and jumper and also connecting to common earth bar.Testing of cables.Make:- Polycab,KEI,RR cable,Finolex
3.5C X 70 SQ. MM. AL. XLPE Armoured
4C X 16 SQ. MM. CU. XLPE Armoured
4C X 6 SQ. MM. CU. XLPE Armoured
4C X 4 SQ. MM. CU. XLPE Armoured
3C X 6 SQ. MM. CU. XLPE Armoured
3C X 4 SQ. MM. CU. XLPE Armoured
Supply, fixing, connection, testing & commissioning of single compression brass/s.s cable glands and crimping type Bimetalic lugs / sockets & reducers with necessary tools and equipments as specified in specifications and IS. The glands and lugs / sockets shall be suitable for cable size and type mentioned above. The job also includes, if necessary, supply and fixing of extension busbar of same material on circuit breaker or panel board terminal / connector to connect more than one no. of parallel cables or to connect higher size cable to lower size unit. The job also includes earthing the glands and armour of the cable with common earth bar or flexible earthing mesh.commet and equivalent
3.5C X 70 SQ. MM. AL. XLPE Armoured
4C X 16 SQ. MM. CU. XLPE Armoured
4C X 6 SQ. MM. CU. XLPE Armoured
4C X 4 SQ. MM. CU. XLPE Armoured
3C X 6 SQ. MM. CU. XLPE Armoured
3C X 4 SQ. MM. CU. XLPE Armoured
UNDER FLOOR RACEWAY / TRUNKING -Supply and laying of Fabricated hot dip galvanised, GI under floor trunking system as per relavent IS. Trunks to be laid in the floor/Wall for the power & LV cables with all necessary acessories to complete the job. (Necessary civil work is part of job) Make:- Legrand,Hager,L&T
300 (W) x 38 (H) mm - 2 mm thick
225 (W) x 38 (H) mm - 2 mm thick
150 (W) x 38 (H) mm - 2 mm thick
100 (W) x 38 (H) mm - 2 mm thick
50 (W) x 38 (H) mm - 2 mm thick
UNDER FLOOR RACEWAY / TRUNKING JUNCTION BOXSupply and installation of Hot dip galvanised, GI fabricated floor junction boxes as per relevent IS. The job includes aligning of boxes with the raceways and making necessary arrangement to take the knock outs from them to lay the wires, with all necessary accessories required to complte the job. (The civil work like cutting of the floor to ambedded in junction boxes in the floor to be inlcuded in the rate). Top cover shall be made up from 2.5 mm thick GI steel plate.Make:- Legrand,Hager,L&T
400 (L) x 400 (W) x 50 (H) mm JB - 2 mm thick
300 (L) x 300 (W) x 50 (H) mm JB - 2 mm thick
225 (L) x 225 (W) x 50 (H) mm JB - 2 mm thick
150 (L) x 150 (W) x 50 (H) mm JB - 2 mm thick
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.Make-Polycab,AKG,Precession
25mm Dia.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
300 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
Earthing- Supply, laying, connection and testing bare earthing conductor for inter-connecting the earthing stations and various equipment in built up trenches, walls/ceiling, buried in ground generally as specified and shown on the drawing complete with Supply & fixing accessories like earthing clamp, saddle, etc.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Primary Light points
Secondary Light points.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.Make:- Polycab,KEI,RR cable,Finolex
3 x 1.5 sq. mm
6 x 1.5 sq. mm
3 x 4 sq. mm
6 x 4 sq. mm
9 x 4 sq. mm
Supply and laying of 25 mm dia ISI approved MMS PVC condiut for power wiring with all necessary accessories to complete the job.
Switches, Sockets & accessories
Supply, fixing, connection and testing of 2nos 3-pin 6 A Universal power plug socket alongwith 2nos 6A switch with top cover plate, PVC/metal back box suitable for modular plate with all accessories to complete the job.Make-Legrand,Hager,L&T
Supply, fixing, connection and testing of 2nos 5-pin 6/16 A Universal power plug socket alongwith 2nos 16A switch with top cover plate, PVC/metal back box suitable for modular plate with all accessories to complete the job .Make-Legrand,Hager,L&T
Supply, fixing, connection and testing of 1no 3-pin 16 A Universal power plug socket alongwith 1no 16A switch with top cover plate, PVC/metal back box suitable for modular plate with all accessories to complete the job.Make-Legrand,Hager,L&T
Supply, fixing, connection and testing of 1no 3-pin 6 A Universal power plug socket alongwith 1no 6A switch with top cover plate, PVC/metal back box suitable for modular plate with all accessories to complete the job.Make-Legrand,Hager,L&T
25A 1-phase Universal socket with one 25 A switch at convenient location with cover plate and all required accessories.(Both switch & socket shall be separate location within 6 mtr) (Provision)Make-Legrand,Hager,L&T
LIGHT FIXTURES AND AUTOMATION Supply, installation, testing & commissioning of fixtures & fittings, ceiling fans, exhaust fans, etc. complete with accessories, tube/lamp etc in on False ceiling / surface of slab/beam by 2 nos (minimum) of 6 mm anchor fasteners or on wall with 2 nos of wood screws, nylon plug etc., suitable supporting frame fixed with rag bolts grouted on the wall/anchor fastener on the beam/on the column & other fixing accessories etc provision & connection with 1.5 sq.mm multistranded copper conductor FRLS PVC wires etc., all as per drawing, specifications & as per the instruction of E.I.C. System efficacy shall not be less than 85 lumens/watt, CRI shall be more than 70.3) Total Harmonic Distortion Voltage and Current shall be less than 15%4) Operating range shall be 140V to 270V5) Power Factor of Luminiare shall be more than 0.956) Luminaire and Lamp shall be LM79,LM80 compliant respectively7) Luminaire shall conform respective IS.8) Luminaire Shall withstand surge protection upto 4 kV9) Luminaire shall carry minimum three years warranty.
LED Linear strip light RGB - minimum 10 W/m with 470 Lumens/mtr, CRI 80, IP20 with necessary driver. Item should carry 3 years onsite comprehensive warrenty. Make- Philips/Bajaj/Crompton/Abby/Signify/wipro/syska
LED Linear strip light - with 1200 Lumens/mtr, Color temperature shall be 2700k, CRI >80, IP20 Item should carry 3 years onsite comprehensive warrenty. Make- Philips/Bajaj/Crompton/Abby/Signify/wipro/syska
Wireless BLE mesh controllable Dimmable built-in constant voltage LED Driver. Input Voltage: 220 - 240 VAC. Maximum Forward Voltage: 24V. Output Current: 6200mA. Output Power: 150W. For LED Strip Lights and Constant Voltage LED Modules. Dimming range 1 – 100 %. Power input on stand-by < 0.35 W. Nominal life-time up to 50,000 h. forming automatically a wireless communication network with up to 250 nodes. nominal Indoor Range: Up to 30 m. The controller should be compatable with the fixturs for which it will bw used. item should carry 3 years onsite comprehensive warrenty. Make:- Casambi/Dynalite/Interact
Apple iPad (7th Gen) 32 GB 10.2 inch with Wi-Fi - interface device for controlling via casambi app item should carry 3 years onsite comprehensive warrenty
TELEPHONE AND DATA SYSTEM
Supply, installation, testing & commissioning of single Telephone outlet RJ 11 Shutter type with its metal boxes boxes and accessories as required. Make: Commscope, Molex, Belden, Panduit, Legrand
2 pair unarmoured cable for telephone socket outlets laid through raceways/conduits/floor trunks etc including terminations on both ends. (Rates of raceways/conduits/floor trunks shall be excluded). Make: Polycab, Kei, RR cable.
Supply, laying, testing and commisioning of 25 mm dia Rigid MMS PVC conduit in wall/ceiling/concealed/open manner.
Supply, installation, testing & commissioning of following Krone connector telephone tag block box, made of 16 SWG MS CRCA sheet, concealed/ surface mounted on MS frame of size 40x40x5mm and grouted on the wall. Fixed on the column free standing type with anchor fasteners, cable end/wire way box with adequate space facility to be provided in the TTB, with front operable hinged door, cam type locking arrangement,etc.20 pair telephone tag block with krone terminals
Supply, Installation, Testing and Commissioning of UTP, Cat6 Information outlet (RJ45) with in-built shutter for protection from Dust including single port face plate & metal back box. Make: Commscope, Molex, Belden, Panduit
Supply, Laying, Testing and Commissioning of CAT 6 cable in provided PVC conduit for wifi access point from Controller to access point with termination on both ends complete as required.Make: Commscope, Molex, Belden, Panduit
Supply & Fixing of 25 mm. dia. medium duty rigid PVC conduits as required.
Patch Cord Cat-6 patch cord; 1 mtr(For Rack and User Side). Make: Commscope, Molex, Belden, Panduit
Patch Cord Cat-6 patch cord; 2 mtr(For Rack and User Side). Make: Commscope, Molex, Belden, Panduit
FIRE DETECTION SYSTEM
Supply, installation, testing and commissioning of addressable type one loop card to be installed in existing Fire Alarm Control panel. Model: NFS2-3030,CPU2-3030D,Make-Honeywell
Supply, installation, testing and commissioning of addressable type Multisensor photo thermal detector with Mounting Base.Make-Honeywell
Supply, installation, testing and commissioning of Above False Ceilling Addressable type photo electric smoke detector with Mounting Base.Make-Honeywell
Supply, installation, testing and commissioning of Recessed Mounted below false ceiling Addressable photo electric smoke detector with Mounting Base.Make-Honeywell
Supplying, installation, testing & commissioning of addressable beam detector with short circuit isolator (inbuilt or seperate) complete with emitter and receiver including connections with remote test features etc complete as required. Make-Honeywell
Addressable Sounder cum Strobe rated at 75 dBA @ 3m for Audible annunciation and 75cd flashintg at 1 Hz for visual indication. Make-Honeywell
Supply, installation and testing of Addressable Manual Call Point (Break glass type) with mounting Back box. Make-Honeywell
Supply, installation and testing and commissioning of LED base response indicator Make-Honeywell
Supply, installation and testing and commissioning of Control module Make-Honeywell
Supply, installation and testing and commissioning Monitor module Make-Honeywell
Supply, installation and testing and commissioning of fault Isolator. Make-Honeywell
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Supply, laying, testing and commisioning of 25 mm dia Rigid MMS PVC medium duty conduit.
DIGITAL PUBLIC ADDRESS / EVACUATION SYSTEM
Supply, Testing and assembling of 6W Metal Grille Recess Mount ceiling Speaker. Make: BOSE, BOSCH, AHUJA, JBL.
Supply, Testing and assembling of 20W metal grill recessed Mount speakers With necessary accessories. Make: BOSE, BOSCH, AHUJA, JBL.
Supply, installation, testing & commissioning of Rack Mount Power Amplifiers (500W) with all required accessories etc., complete as per specifications. Make: BOSE, BOSCH, AHUJA, JBL.
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed PVC conduit of 1 pair 2 C x 1.5 Sqmm including connections and interconnections etc. as required.
Supply, laying, testing and commisioning of 25 mm dia Rigid MMS PVC medium duty conduit.
CCTV SYSTEM
Supply, Installation, Testing & Commissioning of IP Network TDN Low-Light IR Outdoor Dome Camera, 1/2.8" CMOS, 2 MP @30fps, triple stream, Min. Illumination required 0.01 lux @ F1.6 (color), 120dB True WDR, Min. Pixels 1920×1080p, 2.7mm - 12 mm motorized focus & zoom lens, Backlight Compensation, Scene Adaptive Control, 3DNR, Privacy Mask, 3 IR LEDs Smart IR with upto 30m IR distance, H.264& MJPEG, PoE(802.3af) Class 3/ 12V DC/24VAC. IP 66, IK10, Having Operating temp range : –30°C to 60° C. Certifications: ONVIF Profile S compliant, UL, CE, EN, FCC & RoHS compliant.All cameras should be of Honeywell make as existing cameras and NVR are of Honeywell make
Supply & laying of the CAT-6 cable for the CCTV cameras in provided FR PVC conduit.Honeywell make
Supply, laying, testing and commisioning of 25 mm dia rigid PVC medium duty conduit.
Supply, Installation, Testing and Commissioning of UTP, Cat6 Information outlet (RJ45) with in-built shutter for protection from Dust including single port face plate & metal back box.Make: Commscope, Molex, Belden, Panduit
Patch Cord Cat-6 patch cord; 1 mtr Make: Commscope, Molex, Belden, Panduit
Patch Cord Cat-6 patch cord; 2 mtr Make: Commscope, Molex, Belden, Panduit
WI FI SYSTEM
Design, Supply, Installation, Testing and Commissioning of 802.11b/g/n/ac wave1/ac wave2, Dual 2.4/5 GHz, 4x4 MIMO, PoE+(802.3at) Wi Fi Access Point and all necessary accessories as required to complete the job as defined in the specifications and drawings. The APs should be of Cisco make so as to be controlled by our Cisco Wireless Controller [5508]. Make- Cisco
Supply, Installation, Testing and Commissioning of UTP, Cat6 Information outlet (RJ45) with in-built shutter for protection from Dust including single port face plate & metal back box for Wi-Fi points at Wi-Fi end. Make: Commscope, Molex, Belden, Panduit
Patch Cord Cat-6 patch cord; 1 mtr Make: Commscope, Molex, Belden, Panduit
Patch Cord Cat-6 patch cord; 2 mtr Make: Commscope, Molex, Belden, Panduit
Supply, Laying, Testing and Commissioning of CAT 6 cable in provided PVC conduit for wifi access point from Controller to access point with termination on both ends complete as required.All passive network components should be from these OEMs: Make: Commscope, Molex, Belden, Panduit
Supply & Fixing of 25 mm. dia. medium duty rigid PVC conduits as required for wi fi system
Air-Conditioning
DOUBLE SKINNED AIR HANDLING UNITS: Supply, Installation, testing & commissioning of Floor Standing Double Skinned AHU with Sandwiched insulated sectionalized construction having thermal break profile with Mixing chamber and vibration isolations Comprising of Fan section with EC Plug Fan , Connected with fire resistant flexible outlet connection, prefilter section with EU3 class filters, Dual Circuit Cooling coil section with 6R Deep Chilled water Cooling coils & 6R Deep DX Cooling coils having 13 FPI aluminum fins and copper tubes, 2 Pass PVC Moisture eliminators, condensate drain pan duly insulated with cross linked polymer, insulated drain piping; complete with flexible couplings at each coil connection to header, including temperature & pressure gauges for each AHU inlet outlet header; floor mounted unit to be installed on Cushy foot type vibration isolators with 95% vibration isolation efficiency. AHU starter panel shall be in the scope of AHU Supply. The starter should be equipped with required DC supply for operation of two way valve. The DC Voltage shall be as per specific requirement of valve control. Upstream incoming AHU power cable up to starter panel shall be in electrical contractor's scope and down stream cable from panel onwards to filed shall be part of HVAC contractor's scope including terminations. The concrete base blocks for keeping the AHU shall be in the scope of civil contractor. All specifications complete as required and as per the instructions of Engineer-In- Charge. Capacity : 17500 CFM, 55.0 TR & 40 mm ESP (Floor Standing) (With Four EC Fan) AHUs should be EUROVENT certified. Make-ZECO/VTS/CARYAIRE/NUTECH/BLUE STAR/ETHOS
CHILLED WATER PIPING, VALVES & ACCESSORIES: Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with 80 kg/cum density resin bonded fiber glass or 144 Kg/ cu m density mineral wool (non Combustible) pipe section insulation covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints and repairing of damage to building etc. complete as per specifications required and as per the instructions of Engineer-In-Charge. Note: The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 80 mm NB (50 mm thick Insulation) Pipe Make-TATA/JINDAL/SAIL/MSL, Insulation Make-ARMACELL/KFLEX/ARMASOUND
Supply, Installation, testing & Commissioing of U PVC Drain Piping duly insulated with 9 mm Nitrile Rubber & BOPP tape for following size : (For AHU, DX & VRF AC Unit drain) complete as per specifications required and as per the instructions of Engineer-In-Charge
Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water valves duly insulated to the same specifications as the connected piping and adequately supported.(Valve with Insulation) complete as per specifications required and as per the instructions of Engineer-In-Charge. Valve Make-FLOWCON/OVENTROP/BELIMO
BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/hot Water circulation as specified (Chilled Water Valve to be insulated) complete as per specifications required and as per the instructions of Engineer-In-Charge 80 mm NB
Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled water circulation including insulation complete as per specifications required and as per the instructions of Engineer-In-Charge: 80 mm NB
Automatic Air Purge Valve / Drain Valve as per P&I Diagram and complete as per specifications required and as per the instructions of Engineer-In-Charge 25 mm NB
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as per specifications required and as per the instructions of Engineer-In-Charge
Providing & fixing in position the mercury in glass industrial type thermometers complete as per specifications required and as per the instructions of Engineer-In-Charge 1500X1150X600
Supply, Installation, Testing and Commissioning of following sizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modualating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of not less than 25 bar. Complete as per specifications required and as per the instructions of Engineer-In-Charge 80 mm NB Make-FLOWCON/OVENTROP/BELIMO
VRF AC SYSTEM Supply, Installation, Testing & Commissioning of modular type Variable Refrigerant Flow / Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll/TwinRotary Compressor(s), minimum two compressors for above 14HP modules, microprocessor based Controller, top / side discharge type condensing unit(s), with R410A Refrigerant, vibration isolators,with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V+/-10%, 3Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. The foundation for outdoor units should be made in such a way that it can withstand a wind speed of 200 km/h . All complete as per the specifications required and as per the instructions of Engineer-In-Charge. Preferred Make: Toshiba/Mitsubishi Electric/ Daikin/ O-General or Equivalent.
Capacity : 20 HP Capacity Top Disharge Type
Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre filter, fan section with low noise fan / dynamically balanced blower, multi speed motor,coil section with DX Copper coil, electronic expansionvalve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless remote control etc., suitable for operation on single phase 230V±10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shutdown provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. Complete as per specifications required and as per the instructions of Engineer-In-Charge. Capacity : 2.4 TR (3.0 HP) Four Way Cassette AC Unit
VRF System Remote Controller : Supply, Installation, Testing and Commissioning of Corded remotes with LCD Desplay for VRF indoor units. (For Cassette Type IDUs). Complete as per specifications required and as per the instructions of Engineer-In-Charge
Supply, Installation, Testing & Commissioning of BMS Compatible Centralised remote control unit for scheduling, monitoring, fault indication and setting of all indoor machines. The data from these various control units will be accessed by main Centralised Remote Control unit. Complete as per specifications required and as per the instructions of Engineer-In-Charge
Supply, Installation, Testing & Commissioning of Refnet joint, Linear expansion valve with all necessary accessories. (1 set = 1 no. each for Gas + 1 no. each for liquid line). Complete as per specifications required and as per the instructions of Engineer-In-Charge
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft / hard drawn copper refrigerant piping for VRV / VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing / brazing including accessories, insulated with XPLE Class O tubular insulation / with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquidlines, all accessories complete as per specifications required and as per the instructions of Engineer-In-Charge:Copper pipe Make-MANDEV/RAJCO/MEXFLOW/SHRISHYAM
9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
19.9 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
34.9 mmdia(OD)(Harddrawn)withtubethickness1.62mmwith19mm thick insulation
41.27 mmdia(OD)(Harddrawn)withtubethickness1.62mmwith19mm thick insulation
Providing and fixing of Control Cabling between the indoor units & outdoor units. 2C x 1.5 Sq.mm 2XWY XLPE insulated, PVC inner sheathed, copper conductor, armoured , FRLS PVC outer sheathed cables. Complete as per specifications required and as per the instructions of Engineer-In-Charge
Supply, Installation, Testing & Commissioning of AHU KIT for connection of VRF ODU with Third Party AHU Integration. Complete as per specifications required and as per the instructions of Engineer-In-Charge
DX AC SYSTEM Supply, installation, testing & commissioning of Inverter Type DX Hi Wall Split AC Unit consisting of evaporator coil, fan, fan motor, coarse filters housed in a sheet metal casing complete with vibration isolators inclusive of Indoor Unit, Out door unit, cordless remote controllers with batteries & holder, power supply cable along with connecting pin & accessories etc. all complete. The condensing units (Outdoor Units) shall consist of Hermetically Sealed Compressor, Condenser Coil, Fan, Fan-motor, casing supporting stand, drive guard, vibration isolation pads, etc. all complete including Interconnecting refrigerant piping and controls, electrical wiring as per manufacturer's standard supply (3 mtrs.) and electronic control circuit. The above Cost should also include cost of expansion valve, liquid line drier, etc. all complete. Indoor cassette units shall have standard inbuilt condensate drain pump along with all the accessories as supplied by the manufacturer. Inverter type DX Hi Wall Unit should be 5 star rated as per requirement of BEE. Complete as per specifications required and as per the instructions of Engineer-In-Charge Preferred Make: Toshiba/Mitsubishi Electric/ Daikin/ O-General or Equivalent.
Capacity : 2.0 TR Hi Wall Split AC Unit
Capacity : 5.5 TR Ceiling Mounted Ductable AC Unit
Capacity : 8.5 TR Ceiling Mounted Ductable AC Unit
Supply, Installation, testing & commissioning of copper refrigerant piping of suitable dia compatible with the refrigerant gas (Eco-friendly) & air conditioner model with insulation/nitrile rubber sleeves (13 mm thk), end connections with appropriate clamping / supporting arrangement finishing for connectivity from indoor to outdoor unit etc all complete as directed by engineer. Nitrogen Pressure Test of the Piping, and Vacuumizing before pre-charging is part of the piping installation scope. Complete as per specifications required and as per the instructions of Engineer-In-Charge
AIR DISTRIBUTION NETWORK Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes,hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as per specifications required and as per the instructions of Engineer-In-Charge Make-NIPPON/JINDAL/SAIL/BHUSAN
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers complete as per specifications required and as per the instructions of Engineer-In-Charge.
Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications.
Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as per specifications required and as per the instructions of Engineer-In-Charge
Fire Damper
Actuator
Supply, Installation, Testing and Commissioning of powder coated Al sheet double skin, jet diffuser having size of 600 mm dia. with VCD of GI construction including gear assembly, nut bolts etc complete as per specifications required and as per the instructions of Engineer-In-Charge
MS Fabrication Work
INSULATION DUCT THERMAL INSULATION Supplying and fixing of 19 mm thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive forNitrile rubber. The joints shall be sealed with 50 mm wide and 3mm thick self adhesive nitrile rubber tape insulation complete as per specifications required and as per the instructions of Engineer-In-Charge.
DUCT ACCOUTIC INSULATION Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as per specifications required and as per the instructions of Engineer-In-Charge.
AHU ROOM ACCOUSTIC INSULATION Supplying, fixing acoustic lining on wall and ceiling of AHU rooms with 50mm thick, density 32 kg/cu.m resin bonded glass fiber insulation friction fixed in 610mm x 610 mm frame work made of 25X50X50X50X25 mm made out of 0.6mm thick GI sheet U shaped channel and covered with reinforced fiber glass tissue and finished with 0.80 mm perforated aluminium sheet etc. complete as per specifications required and as per the instructions of Engineer-In-Charge.
AUTOMATIC SPRINKLER SYSTEM Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as per specifications required and as per the instructions of Engineer-In-Charge : Make-TATA/JINDAL/SAIL/MSL
150 mm nominal dia
125 mm nominal dia
100mm nominal dia
80 mm nominal dia
65 mm nominal dia
50 mm nominal dia
40 mm nominal dia
32 mm nominal dia
25 mm nominal dia
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes complete as per specifications required and as per the instructions of Engineer-In-Charge :
150 mm nominal dia
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories complete as per specifications required and as per the instructions of Engineer-In-Charge
Pendent Sprinkler
Upright Sprinkler
Concealed Sprinkler
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes Complete as per specifications required and as per the instructions of Engineer-In-Charge.
Providing & fixing of pressure switch in M.S. pipe line including connection etc. complete as per specifications required and as per the instructions of Engineer-In-Charge.
Providing & fixing flow switch in following sizes M.S. pipe including connection etc Complete as per specifications required and as per the instructions of Engineer-In-Charge.
SAHAI EXCLUSIVE CONTRACST PVT. LTD.
NEW AGE ACOUSTICS PVT LTD
SHREEMAN AND AMAN INFRA PRIVATE LIMITED
Decor India
Creative Design
Stencil Engineering Private Limited
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .