Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 LAccepted-AOC | ₹5.0 L | L1 | Accepted-AOC Quoting Lowest rate |
| 2 | L2₹5.1 LRejected-Finance VILL ADHARMANIK P O BASUDEVKHALI P S BERHAMPORE DIST MURSHIDABAD | BERHAMPORE | MURSHIDABAD | WEST BENGAL | 742101 | ₹5.1 L | L2 | Rejected-Finance Quoting Higher rate |
| 3 | L3₹5.1 LRejected-Finance | ₹5.1 L | L3 | Rejected-Finance Quoting Higher rate |
| Sl No | Description | Qty | Unit | BURDWAN REFRIGARATION SERVICE L3 | JASODA REFRIGERATOR SERVICING CENTRE L1 | SRIDAM MONDAL L2 |
|---|---|---|---|---|---|---|
| 1.00 | Supply & Delivery of 2.0 TR capacity concealed type wired non inverter Split Air Conditioner of rated cooling capacity of 24000 BTU/hr. with 1Nos. rotary compressor with R410A/R32 Refrigerant, 1nos. IDU of rated power supply-230V-1ph-50Hz. , 1no. ODU of rated power supply-230V-1ph-50Hz. Air-flow/per IDU:- 800CFM. Copper Condenser. AC must be following essential requirement-
i) Indoor & outdoor Control Circuit should be enclosed in Metal Box to prevent fire as per CEWE order.
ii) P2 protected capacitor must be include each RAC.
iii) Warranty On PCB : 1 year & 5 years on Compressor (Make : Hitachi / Mitshubishi Electric / O General) | 4 | Nos | 87,000 ₹3.5 L | 86,100 ₹3.4 L | 86,730 ₹3.5 L |
| 2.00 | Installation (of both all IDU & ODU), Testing and Commissioning charges including refrigerant Gas charging for 2.0 TR Concealed Split Air Conditioner. All IDU to be suspended from ceiling / wall with all necessary suitable size MS frame arrangement incl. tie rod etc. The indoor and outdoor unit must be supported by structure made of 40 x 40 x 6 mm angle and 25 x5 flat and tie rod incl. necy. Painting & as per direction & satisfaction of EIC. | 4 | Items | 6,600 ₹26,400 | 6,550 ₹26,200 | 6,573 ₹26,292 |
| 9.00Supply & installation of Easty to bend, Corrossion free Annealed Copper refrigeration pipe line complete with fitting, elbows, bends, supporting arrangement (G.I. saddle) on wall. | ||||||
| 9.01 | b) Liquid Line (1/4" OD with 0.6mm thick) (make: Godrej /Carrier Total Line / MI Copper or brand approved by EIC) | 64 | Mtrs | 190 ₹12,160 | 185 ₹11,840 | 187 ₹11,968 |
| 9.02 | b) Suction line (5/8" OD with 0.7mm thick) (make: Godrej / Carrier Total Line / MI Copper or brand approved by EIC) | 64 | Mtrs | 365 ₹23,360 | 364 ₹23,296 | 363 ₹23,232 |
| 10.00S & F 9 mm thick Nitrile rubber tube Insulation on suction / liquid line copper pipe of concealed split AC with wrapping Al foil cover.( Make - Armacell / K Flex / Supreme) | ||||||
| 10.01 | a) Liquid Line | 64 | Mtrs | 45 ₹2,880 | 42 ₹2,688 | 45 ₹2,880 |
| 10.02 | b) Suction line | 64 | Mtrs | 55 ₹3,520 | 50 ₹3,200 | 53 ₹3,392 |
| 11.00Supply & Laying of 1.1KV grade following sizes Unarmoured Cu cable for main MCB to ODU & ODU to IDU connection. Termination points must be socketed with Cu ring / pin type socket as per requirement. (Cable Make - RR / KEI / Polycab) | ||||||
| 11.01 | a) 4 Core 2.5 Sq.mm | 68 | Mtrs | 307 ₹20,876 | 292 ₹19,856 | 294 ₹19,992 |
Tender Value
Refer Docs
EMD Value
₹11,000
Closing Date
5 Jul 2024, 11:00 amClosed
Superintending Engineer
Office of the Superintending Engineer, Western Electrical Circle , PWD, Purta Bhavan, 1st floor, Burdwan-713103
Additional work for SITC of Air Conditioning arrangement at OT of Level-II Trauma Centre unit at Anamoy SSWH second campus of BMCH in the District of Purba Bardhaman.
2024_WBPWD_701643_1
WBPWD/SEWEC /BED /NIQ-25/2024-25
Open Tender
ELECTRICAL WORKS ORG
45 days
Burdwan
Please refer Tender documents.
5 documents required · 5 mandatory
₹11,000
Office of the Superintending Engineer, Western Ele
1 Jun 2026
27 Jun 2024
8 Jul 2024
27 Jun 2024
5 Jul 2024
29 Jun 2024
27 Jun 2024 - 28 Jun 2024
28 Jun 2024
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid