Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.4 LAccepted-AOC R G BARUAH ROAD NEAR SHIV MANDIR GUWAHATI AIRPORT GUWAHATI 781015 | KAMRUP METRO | ASSAM | 781015 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹20.4 L+₹2.1 L (11.6%)Rejected-Finance GOSWAMI COLONY PO UDAYAN VIHAR DISTT KAMRUP ASSAM 781171 | KAMRUP METRO | ASSAM | 781171 | L2 | Rejected-Finance Not Validated (Other than lowest bidder) | |
| 3 | L3₹23.9 L+₹5.6 L (30.3%)Rejected-Finance HOUSE NO 29 A SIJUBARI NIZARA PATH PO PS HATTIGAON GUWAHATI 38 | KAMRUP METRO | ASSAM | 781038 | L3 | Rejected-Finance Not Validated (Other than lowest bidder) | |
| 4 | Rejected-Technical 0 PRAGATIPUR DHARMA SARMA PATH BIRUBARI KAMRUP ASSAM 781016 | KAMRUP METRO | ASSAM | 781016 | - | Rejected-Technical Not Admitted | |
| 5 | Rejected-Technical MOTHER TERESA ROAD ZOO TINIALI GUWAHATI 781024 | GUWAHATI | KAMRUP METRO | ASSAM | 781024 | - | Rejected-Technical Not Admitted |
Tender Value
Refer Docs
EMD Value
₹56,000
Closing Date
6 Jun 2023, 6:00 pmClosed
GE GUWAHATI
GE GUWAHATI, PO SATGAON, DISTT KAMRUP - 781027
REPAIR/MAINT OF ACs, REFRIGERATORs, WATER COOLERs, VOLTAGE STABLIZER AND DEEP FREEZERs AT VARIOUS LOCATIONS UNDER GE GUWAHATI
2023_MES_593195_1
GE/GUW11/8325 OF 2023-24
Open Tender
Civil Works
Item Rate
150 days
GUWAHATI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE GUWAHATI
₹56,000
Yes
22 Jun 2023
4 May 2023
8 Jun 2023
4 May 2023
6 Jun 2023
24 May 2023
4 May 2023 - 11 May 2023
Amount
M & L for taking out the defective / burnt out compressor from Split type air conditioner of 1.5 Ton capacity from its position and providing new compressor Rotary / Reciprocating of approved make best suitable for the unit, cleaning the refrigeration system thoroughly with CTC, leak testing, vaccumisation, charging with new refrigerant gas suitable for the unit testing for its effective functioning, connecting up all electrical connections and finally testing and commissioning including cost of cutting, brazing , sealing the refrigeration tubing, replacement of stainer, CTC, refrigerant gas, CO2, etc. as required for the job complete all as directed. Notes:(i) Quoted rate is deemed to be inclusive for cutting, brazing, sealing the refrigeration tubing, replacement of stainer, CTC, refrigernat gas including transportation charges from site to workshop and back
M & L for taking out the defective / burnt out compressor from Split type air conditioner of 2.0 Ton capacity from its position and providing new compressor Rotary / Reciprocating of approved make best suitable for the unit, cleaning the refrigeration system thoroughly with CTC, leak testing, vaccumisation, charging with new refrigerant gas suitable for the unit testing for its effective functioning, connecting up all electrical connections and finally testing and commissioning including cost of cutting, brazing , sealing the refrigeration tubing, replacement of stainer, CTC, refrigerant gas, CO2, etc. as required for the job complete all as directed. Notes:(i) Quoted rate is deemed to be inclusive for cutting, brazing, sealing the refrigeration tubing, replacement of stainer, CTC, refrigernat gas including transportation charges from site to workshop and back
S&F in repair, compressor unit of refrigerator 400 litres capacity including necessary cutting welding complete with all fixing accessories as required and as directed. Note - Leakage testing, flushing of system and charging of gas shall be measured and paid separately under relevant items here in after. all as specified and directed.
S&F in repair, compressor unit of water cooler upto150 litres capacity including necessary cutting welding complete with all fixing accessories as required and as directed. Note - Leakage testing, flushing of system and charging of gas shall be measured and paid separately under relevant items here in after. all as specified and directed.
S&F in repair, compressor unit for Deep Freezer capacity 320 Ltr including necessary cutting welding complete with all fixing accessories as required and as directed. Note. Leakage testing , flushing of refregerator system and charging of gas shall be measured and paid separately under relevant items here in after.
Supply and charging of refrigerant gas suitable for window / split air conditioners / water collers / refrigerators complete all as directed.
M & L for leak testing with N2 gas of entire refrigeration system, rectification of leaks by welding / brazing and pressure testing as per the standards and holding the pressure for 24 Hrs and observe for any pressure drop in the system including evacuation with vaccum machine complete all as directed.
S&F in repair, blower fan motor for hot air upto 2.0 Ton capacity Split air conditioner/window Air conditioner fan motor double shaft type suitable for air conditioners 800 to 1250 RPM including testing complete all as directed.
S&F in repair, blower fan motor for water cooler upto 150 Ltr capacity complete all as directed.
S&F in repair, blower fan blade for hot air / cool air suitable for split type/window type air conditioner upto 2.0 Ton capacity, balancing for smooth rotation in the casing and testing complete all as directed.
S&F in repair, blower fan blade for water cooler upto 150 Ltr capacity balancing for smooth rotation in the casing and testing complete all as directed.
S&F in repair, running capacitors with new capacitors 45 mfd rating complete all as directed.
S&F in repair, running capacitors with new capacitors 50 mfd rating complete all as directed.
S&F in repair, running capacitors with new capacitors 25 mfd rating complete all as directed.
S&F in repair, starting capacitors with new capacitors 80-100 mfd rating complete all as directed.
S&F in repair, starting capacitors with new capacitors 100-120 mfd rating complete all as directed.
S&F in repair, condensation coil upto 2.0 Ton capacity window / split type air conditioner including testing complete all as directed.
S&F in repair,condensation coil upto 150 Litres capacity water coolers including testing complete all as directed.
S&F in repair, condensation coil upto 400 Litres capacity Refrigerators/Deep freezers including testing complete all as directed.
S&F in repair, contactor single phase suitable for Split/window air conditioners upto 2.0 Ton capacity complete all as directed.
S&F in repair, Relay suitable for Split AC upto 2.0 Ton capacity complete all as directed.
M & L for servicing of Air conditioners of any make and capacity with electrical blower and motor, cleaning with castic soda and soap water to all the parts including evaporator, condenser, grills, etc and checking of all the electrical connections, etc complete all as directed.
M & L for servicing of water coolers, Refrigerators and deep freezers of any make and capacity with electrical blower and motor, cleaning with castic soda and soap water to all the parts including evaporator, condenser, etc and checking of all the electrical connections, etc complete all as directed.
M & L for rewinding of unserviceable blower / fan motor of any capacity Split type/window type AC including dismantling the motor completely, removing old winding, cleaning the starter, rewinding the motor with appropriate gauge super enamelled copper conductor and insulating materials and fixing back the motor in original position including testing complete all as directed.
M & L for rewinding of unserviceable blower / fan motor of any capacity Water Cooler including dismantling the motor completely, removing old winding, cleaning the starter, rewinding the motor with appropriate gauge super enamelled copper conductor and insulating materials and fixing back the motor in original position including testing complete all as directed.
M & L for rewinding of unserviceable blower / fan motor of any capacity Deep freezer/Refrigerator including dismantling the motor completely, removing old winding, cleaning the starter, rewinding the motor with appropriate gauge super enamelled copper conductor and insulating materials and fixing back the motor in original position including testing complete all as directed.
S&F in repair, air filters, non woven, synthetic, high efficiency washable type suitable for 1.5 / 2.0 Ton capacity Air conditioners complete all as directed.
S&F in repair, printed circuit board of Split AC / Window AC / water cooler / refrigerator of 230 Volts single phase any capacity complete all as directed.
S&F in repair, Electronic Printed Circuit board for outdoor unit of inverter type Split AC of 1.5/2.0 Ton capacity complete all as directed.
S&F in repair, Electronic Printed Circuit board for indoor unit of inverter type Split AC of 1.5/2.0 Ton capacity complete all as directed.
S&F in repair, copper tubing 24 SWG of size 5/8" along with tubular insulation suitable for Split AC complete all as specified and directed.
S&F in repair, room sensor suitable for Split type /Window type AC of capacity 1.5 TR to 2 TR ,complete all as specified.
S&F in repair, coil sensor suitable for Split/window type AC of capacity 1.5 TR to 2 TR ,complete all as specified.
S&F in repair, copper tubing 24 SWG of size 1/2" along with tubular insulation suitable for Split AC complete all as specified and directed.
S&F in repair, copper tubing 24 SWG of size 1/4" along with tubular insulation suitable for Split AC complete all as specified and directed.
S&F in repair, PVC drain pipe of 20mm bore complete all as specified and directed.
S&F in repair, Split AC Valves made of high grade free cutting brass and copper for pipe of size 1/2", 1/4", 3/8" and 5/8" complete all as specified and directed.
M&L electronic remote control with hand set with wall stand suitable for Split AC of 1.5 / 2.0 Ton capacity of existing make and model complete all as directed. .
S&F in repair, copper capillary tube suitable for Split AC of 1.5 / 2.0 Ton capacity complete all as directed.
S&F sheet metal enclosure with single pole and neutral enclosure with a two pin and earth plug and socket complete with one MCB, SP, 20 Amps, 240 volts, 10 KA complete all as specified and directed.
M&L for cutting and removing rusted steel body of Water coolers of any type and welding new MS sheet of suitable gauge as per existing including necessary bending as required and applying two coats of synthetic enamel paint over a coat of primer complete all as directed.
Repairs to Voltage stabiliser including replacing the defective parts like relay, bridge, transformer, glowing lamps and making serviceable for automatic operation, for input variation between 170 to 250 volt and output voltage stabilised at 230 volt with accuracy of + 2.5% of capacity 4.0 / 5.0 KVA complete all as directed.
S&F in repair, lift/push cock chromium plated brass of 15mm size suitable for water cooler of capacity 40/80 Litres complete all as directed.
S&F in repair, thermal insulation for indoor to outdoor copper pipe suitable for split type AC of any capacity complete all as directed.
S&F in repair, Thermostat suitable for water cooler of capacity upto 150/150 Litre complete all as directed.
S&F in repair, Overload protector suitable for water cooler of any capacitycomplete all as directed.
S&F in repair, stainless steel drain tray made of SS 304 suitable for water coolers of any capacity complete all as directed.
S&F in repair, PVC copper conductor cable of size 3 core 4 Sqmm for connecting indoor unit to outdoor unit complete all as directed.
M & L for core cutting hole for passing AC drain pipe and copper tubing from indoor unit to outdoor unit in any type of wall including making good to the disturbed surfaces to match with adjoining surfaces complete all as directed.
S&F in repair, swing motor suitable for split / tower AC of any capacity complete all as directed
S & F Pre-fabricated brackets (stands) for outdoor units of Split AC units made of heavy duty GI Sheet thick High Grade Anti Corrosive Metal Plates duly Powder Coated for rust prevention complete all as specified and directed.
M&L for dismantling of existing Split AC unit of any make and capacity (indoor and outdoor unit) from any position after disconnecting from main supply including shifting and installing the same at new location duly restoring the refrigerant gas and connecting with electric supply and testing for its smooth working complete all as directed
S&F in repair, voltage stabiliser for automatic operation, single phase naturally air cooled, copper wounded as per IS 8448-1989 with digital display, wall mounted, indoor type & designed for input variation between 170 Volts to 250 Volts with output voltage stabilsed at 230 Volts with accuracy of + 2.5% and of capacity 4 KVA complete all as specified and directed.
S&F in repair, wire mesh suitable for outdoor unit of Split AC outdoor units complete all as directed
S&F in repair, connector suitable for Split AC units for 1.5-2 TR for connecting wire / cable from indoor unit to outdoor unit complete all as directed
S&F in repair, 40mm dia PVC Drain Pipe including all accessories(ie Bend/Elbow/Tee/Reducer/GI Clamps etc) for connecting of Split AC drains in series on Building roof/Wall/Chhajja complete all as specified and directed.
S&F in repair, Power Plug Top suitable for Split/Window AC/Refrigertor/Deep Freezer/Water Cooler for connecting in Power Socket complete all as specified
S&F in repair, non magnetic gasket top corner for water cooler complete all as specified and directed
S&F in repair, magnetic gasket for Refrigerators complete all as specified and directed
S&F in repair, tubular insulation Foam suitable for copper Tubes of Split AC 1-2 TR complete all as specified and directed
S&F in repair, white rebon/white Teplon roll for insulation of split AC outer copper Tubes complete all as specified and directed
NOTE : The works/item mentioned at Sl item No, 01 to 61: - Note 1:- The contractor or his represantative will report in complaint cell to receive the complaints in the morning by 0900hrs. The tenderer shall note that the scope of subject contract is to provide proper services for efficient and timely repair of complaints as per items as specified in BOQ. The contractor shall deploy sufficent staff for proper functioning and timely completion of complaints to the entire satisfaction of Engineer-in-Charge. Note.2 :- The complaints should be complete within 48 hours after receiving the complaint slip failing which a penalty of Rs. 1000/- per complaint days will be recovered from payment with out any prejudise and contractor shall not have any claim on this account . Note No 3 :- All the work shall be executed by well qualified authorized technician of company Note 3:- Documentary evidence against Each complain Recieved and completion report of each complain shall be submitted along with bills dully signed by Engg-In-Charge and contactor
M.G. ENTERPRISE
M/S SEWAK SINGH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .