| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 | BHAVNAGAR | GUJARAT | 364001 | ₹1.2 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹1.4 Cr+₹13.1 L (10.7%)Rejected-Finance 1 128 A SECOND FLOOR MOHAMMADPUR NEAR BHIKAJCAMA PLACE NEW DELHI 110066 | NEW DELHI | NEW DELHI | DELHI | 110066 | ₹1.4 Cr+₹13.1 L (10.7%) | L2 | Rejected-Finance other than L1 |
| 3 | L3₹1.4 Cr+₹19.6 L (16.0%)Rejected-Finance 203 B CHAHBAI BAREILLY UP 243001 | BAREILLY | BAREILLY | UP | 243001 | ₹1.4 Cr+₹19.6 L (16.0%) | L3 | Rejected-Finance other than L1 |
| 4 | L4₹1.5 Cr+₹26.7 L (21.8%)Rejected-Finance 160 PREM NAGAR BAREILLY | ₹1.5 Cr+₹26.7 L (21.8%) | L4 | Rejected-Finance other than L1 |
| 5 | L5₹1.6 Cr+₹39.1 L (32.0%)Rejected-Finance 578 AVAS VIKAS JANAKPURI B IZATNAGAR BAREILLY 243122 UP | BAREILLY | UTTAR PRADESH | 243122 | ₹1.6 Cr+₹39.1 L (32.0%) | L5 | Rejected-Finance other than L1 |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
19 May 2025, 6:00 pmClosed
CWE(AF) BAREILLY
HQ Commander Works Engineers AF Military Engineer Services Bareilly 243002
AS DESCRIBED IN BOQ
2025_MES_700058_2
81511/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
BHOWALI
AS PER NIT
9 documents required · 9 mandatory
₹1,000
AGE(I) AF BHOWALI
₹2.2 L
Yes
22 Jul 2025
24 Apr 2025
21 May 2025
24 Apr 2025
19 May 2025
14 May 2025
24 Apr 2025 - 6 May 2025
Amount
SCH 'A' PART-I (EARTH WORK & SITE DEVELOPMENT ) Note: Excavation & earh work included under this part and shall be measured for all parts)
Excavation over area n.exc 1.5 m deep and getting out, in hard/dense soil complete all as specified and as directed.
Excavation over area n.exc 1.5 m deep and getting out, in hard rock, complete all as specified and as directed.
Excavation over area exc 1.5 mtr deep but n.exc 3.0 mtr and getting out, in hard rock, complete all as specified and as directed.
Excavation over area n.exc 1.5 m deep and getting out, in soft/disintegrated rock ,complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 Mtrs. wide and not exceeding 1.5 Mtrs. in depth for foundation, laying of cables etc and getting out, in hard/dense soil complete all as specified.
Excavation in trenches not exceeding 1.5 Mtrs. wide and not exceeding 1.5 Mtrs. in depth for foundation, laying of cables etc and getting out, in soft/disintegrated rock complete all as specified.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out, in soft/disintegrated rock complete all as specified and directed.
Returning filling in, including spreading. Levelling, watering and well ramming in layers not exc. 25 cm in soil' complete all as specified and as directed.
Removing excavated material (Soil) n.exc 50 m and depositing where directed at a level n. exc 1.5 Mtrs. above the starting point complete all as specified.
Removing excavated material (rock) n.exc 50 m and depositing where directed at a level n. exc 1.5 Mtrs. above the starting point complete all as specified.
Removing excavated material (soil) to a distance exc. 250 mtr and not exc 500 mtr, depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
SCH 'A' PART-II (BUILDING WORK INCLUDING INTERNAL WATER SUPPLY)
M&L PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete all as specified and as directed.
M&L for fly ash bricks,with old size bricks straight or curved on plan exc 6m mean radius built in CM 1:6, concrete all as specified and as directed.
M&L for providing, cement concrete type B-1 1:2:4 (using 20 mm aggregatrs) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating as directed
M&L Rendering 15mm thick on fair faces of brick work or concrete surface in cement plaster 1:4 finishing the surface even & smooth without using extra cement & with WPC (WPC will be measured & paid seperately) complete all as specified & as directed.
M&L rendering 15mm thick in cement plaster 1:6 on other than fair face of brickwork complete all as specified & as directed.
Supply only WPC. (Integral Water Proofing Compound) all as specified & as directed.
M&L for preparation of newly plastered surfaces and applying two coats of cement base paint over a coat of chalk whiting complete all specified and directed.
M&L for preparation of newly plastered surfaces and applying three coats of white wash complete all specified and directed.
S&F rolled steel sections for joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) Fe 410-W (Gde E- 250) quality A complete all as specified and as directed.
S&F for mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing Fe 410 -W (Gde E- 250) quality A complete all as specified and as directed.
S&F for mild steel, plain, black sheet 1 mm thick in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and as directed.
S&F for mild steel rolled sections in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Fe 410-W (Gde E- 250) quality A complete all as specified and as directed.
S&F for Welded steel wire fabric n. exc 4 kg/Sqm supplied and fixed to wood or steel members complete to wood or steel members complete all as specified and as directed.
S&F plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, with attachment conforming to Fe-410-W and gde-E-250 , quality -A as in gusset plate complete all as specified and directed.
M&L MS screw bolt diameter of shank 11 to 15mm (machine made) with hexoganal head at one end screwed the other or screwed both ends each screw end fitted with washers and one hexagonal nut, exe 05cm not exe 10cm complete all as specified and directed.
S&F of 0.5mm thick Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
All as per item No.29 here-in-before but plain as in ridge complete all as specified and directed.
S&F for hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; complete all as specified and directed.
M&L for preparation of new steel surfaces n. exc. 10 cm width or girth when unconnected with other painting or when painted in a different tintand applying two coats of synthetic enamel paint over a coat of red-oxide primer complete all as specified and directed.
M&L for one coat of black bitiminious paint including preparation of new steel surface of any description, over 10 cm in width or girth, complete all as Specified.
M&L moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
M&L hardcore of broken stone/boulders gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 100 mm thick cement concrete 1:4:8 type D- 2, (40mm graded aggregate) as in sub base to floors etc., complete all as specified and directed.
M&L for machine cut kota stone slab flooring 20-25mm thick over 20mm thick in CM 1:6 cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar including 10 mm thick rendering in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for 75 mm thick cement concrete 1:3:6 type C-1 (20mm graded aggregate) finishing even and smooth without using extra cement as in plinth protection complete all as specified and directed.
M&L for preparation of new steel or iron surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paints over and including one coat of red oxide, zinc chrome primer complete all as specified and as directed.
SCH 'A' PART-III {PATH)
M&L for 100 mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in subase finished to receive floor treatment etc complete all as directed.
M&L for Sand filling under floors or in foundations including watering and consolidation 25 mm thick all as specified and directed.
M&Lfor 60mm thickness M-35 Grade precast concrete interlocking paver block and pointed with grey cement and pigment and of approved size and shape and confirming to IS 15658-2006, complete all as directed.
SCH 'A' PART-IV {RETAINING WALL)
M&L for stone walling of random rubble stone masonary, uncoursed, well bounded, bedded & solidely hearted built in cement mortar (1:6) using locally available best stone complete all as specified and directed
M&L for providing PCC bond stone (for stone walling), type B1 1:2:4 (20 mm graded aggregate) set in CM 1:6 complete all as specified and directed
Deduct for PCC Bond stone as per Preamble No 6.2.7 (a) of SSR-2020 (Part-II)
Extra over stone wallling for hammer dressing to face stones & dressing to face beds and joints as specified at RR walling uncoarsed or brought upto coarse, max depression on face from straight edge held against the dressed surface n.exc 20 mm complete all as specified and directed.
M&L for PCC type C1 1:3:6 (20 mm graded aggregate) as in coping including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
M&L for raised pointing to RR, uncoarsed or brought upto course stone masonry in CM 1:4 complete all as specified and directed.
M&L for hand packing (any thickness) broken stone at back of wall and raising (or lowering) to the required level complete all as specified and directed
M&L for uPVC pipe 100 mm bore (SCH-80) laid in retaining wall complete all as specified and directed
SCH 'A' PART-V {SWT 01 Nos 25 KL AND 02 Nos 50 KL CAPACITY)
M&L for PCC 1:2:4, type B2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete etc. complete all as specified and as directed.
M&L for RCC M-30 design Mix (using 20mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc. basement slabs, under-reamed piles and mass concrete etc. complete all as specified and as directed.
M&L for RCC M-30 design Mix (using 20mm graded stone aggregate) as in walls, retaining walls,basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses foundations etc. complete all as specified and as directed.
Use and waste formwork to sides of curved concrete foundations, footing, bases of columns, plinth beams for rough finished surfaces of concrete complete all as specified and as directed.
Use and waste formwork to curved faces of walls,retaining walls and similar work including attached pillasters, buttresses, etc.; vertical or to batter complete all as specified and as directed.
M&L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape as required including cutting, bending cranking, hooking end and binding with mild steel wire(annealed) not less than 0.9mm dia as in reinforcement bar complete all as specified and as directed.
M&L for 12 mm thick rendering in cement mortar (1:4), to fair faces of brick or concrete wall surfaces, mixed with water proofing compound (@ 3% by weight of cement or as per manufacture's instructions), finished the surface even and smooth without using extra cement complete all as specified and as directed. Note : Water proofing compound will be measured and paid separately as "Supply only".
M&L for 5 mm thick rendering in cement mortar (1:4), to fair faces of brick or concrete wall surfaces, finished the surface even and smooth without using extra cement complete all as specified and as directed.
M&L for preparation of newly plastered surface of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and as directed.
S&F plate girder or single stanchions, built up of one beam or channel section with flange plates, caps, bases. splices, angle brackets, cleats and other connections as in base for tank covering Fe 410 -W (Gde E- 250) quality A complete all as specified and as directed.
S&F 4mm dia galvanised steel wire, 150x100mm mesh, weight not less than 4kg/sqm made up into mattresses or cages, lapped, wired and laid in position, including closing after filling complete all as specified.
S&F mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in MS rungs Fe 410 -W (Gde E- 250) quality A or Fe 290 (Gde - E-165) complete all as specified and as directed.
M&L for prepration of new Surfaces of metal any description, over 10cm in width or girth,not otherwise described priming with red oxide and applying two coats of synthetic enamel paint complete all as specified.
M&L for preparation of new steel or iron surfaces of any description n.exc.10cm width or girth when unconnected with other painting or when painted in a different tint and applying two coats of black japan paints over and including one coat of red oxide, zinc chrome primer complete all as specified and as directed.
M&L for preparation of new concrete surfaces and application of Nitobond EP Std (Manufactured by Forsoc Chemicals India Ltd.) epoxy bonding agent over the new concrete surfaces complete all as specified and directed.
S&F PVC Water Bar/flexible waterstop of size 240 mm width and 8 mm thick based on specially formulated plasticized PVC composition, ribbed with a central bulb to withstand expansion and contraction of joints conforming to IS 15058 or IS 12200 complete all as specified and directed.
SCH 'A' PART-VI (FIRE FIGHTING)
Supply & fix fire hydrant landing valve type A (double head outlet) of 63 mm dia conforming to IS 5290 complete all as specified and as directed .
Supply and fix Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard for hose reel of 20 mm size of 30 meter length complete all as specified and as directed.
supply and fix Branch pipe gun metal 63mm instantaneous inlet, made threaded outlet, 20 mm bore nozzle short complete all as specified and as directed.
Supply and fix hose reel with drum of 20 mm dia and 30 meter length conforming to IS 12285 complete in all respect all as specified and as directed.
Supply and fix reinforced runner lined fire hose type A ISI marked confirming to IS 636,15 mtr long with ISI marked stainless steel coupling dia 63 mm, complete all as specified and as directed.
Supply and fix flanged stand post / Stand Post 80mm Dia GI / MS both flanged type 1.5m Height with provn of single outlet conforming to IS 908, complete all as specified and as directed.
Supply and fix Fire Alarm sounders / Sirens electronic type horizontal two stage continous normal operation for atleast 50 minutes with sound level 65 db to 120 db Measured at 1.5m with sound output Variation of + 5 db 3500m range complete all as specified and as directed .
Supply and fix Booster pump for 440 V, 3 Phase, 50 Hz conforming to IS- 12469 :1988 With CI Casing bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for 440 volts, 3 phase, 50 Hz 30m head, 450 LPM discharge complete all as specified and as directed. (At Lariakata -01 nos)
Supply and fix Fire pump electrically driven horizontal end Suction, centrifugal type conforming to IS- 12469 :1988 with CI Casing , bronze impeller and Stainless steel shaft mounted on heavy duty bearings Suitable for continuous operation with 'range of operation' 0 % to 150 % of rated capacity for 440 V , 3 Phase. 50 Hz 70m Head, 1620 LPM discharge complete all as specified and as directed. (LKT-1, Helipad -1)
Supply and laying mild steel flanged pipe 150mm nominal bore, Class-B heavy grade with all fittings laid in floors or fixed to walls and ceilings etc duly painted with 2 coats of synthetic enamel paint over coat of zinc chromate primer complete all as specified and as directed.
Supply and laying mild steel flanged pipe 100mm nominal bore, Class-B heavy grade with all fittings laid in floors or fixed to walls and ceilings etc duly painted with 2 coats of synthetic enamel paint over coat of zinc chromate primer complete all as specified and as directed.
Supply and fix 150mm bore hand operated butterfly valve of pressure not less than 15 Kg / Sqcm with complete set all as specified and as directed.
Supply and fix 100mm bore hand operated butterfly valve of pressure not less than 15 Kg / Sqcm with complete set all as specified and as directed.
Supply and fix Pressure gauge 4"dial with ball valve of pressure 21 Kg/Sqcm rating complete set all as specified and as directed.
Supply and fix tubes, 'medium grade', galvanised, 80mm bore with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified
Supply and fix tubes, 'medium grade, galvanised, 50mm bore with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified
Supply and fix Gun metal globe valves with iron wheel head ,screwed both end for GI pipe of dia 50mm omplete all as specified
Supply, erecting, testing and commissioning complete of manufacturer or OEM manufactured, static silent (Sound Proof enclosure) water cooler Diesel Engine Driven Generating Set capable of delivering 100 KVA air cooled, 415 Volts (AC three phase, 4 wire system of supply) 50 HZ . The DG Set shall consists of alternator coupled to a matching capacity DG Set engine, through flexible coupling and mounted on common base frame with AVM with and complete with Automatic on Mains Failure (AMF) control panel standardized by manufacturer, fuel tank with mounting arrangements, draw plug, air vent inlet and outlet connection level indicator exhaust pipe all suitable for conditions at Lariakanta including PCC foundation as per manufacturer's instructions, anti vibration pads, including all features to comply with latest CPCB IV+ guidelines sound proof acoustic enclosure along with emission control device and comprising of followings :-
(i) Engine (Prime Mover) : Diesel Engine 1500 RPM, direct injection, multi cylinders,self/manually start four Stroke confirming to ISO 3046/BS 5514, air cooled,with first fill oil confirming IS 10002,ISO3046,BS 5514 Standrards All diesel Engines are comply with latest CPCB norms naturally turbo charged, capable of delivering adequate BHP at outdoor atmospheric conditions at Bhowali (taking all derating factor info consideration to drive alternator capable of delivering 100 KVA , 12/24 Volt (as per manufacturer recommendations) electric battery start, complete with fly wheel all standard fittings/fixtures as per manufacturer and including suitable panel with tachometer, lube oil temperature meter , pressure gauge and frequency meters and also including self starter system, dynamo fuel gauge electric control penal with electronic governor (ECPG) and Engine protection system (Shut down at high temperature, low lube oil, oil pressure, over spped etc) fuel tank -Electric starter motor 12V/24V as per manufacturer. -Battery charging alternator. -Fuel system with electronic governor with mechanical governor as back up. -Due spin-on fuel filter with replaceable cartridge. -Spin-on full flow lub oil filter and pump. -Residential type silencer. -Dry type replaceable paper element air cleaner. -Recovery bottle. -Lube oil cooler. - 12V maintenance free 180AH battery with led and terminal. -Flywheel and flywheel housing to shut single bearing alternator.
Supply, erecting, testing and commissioning complete of manufacturer or OEM manufactured, static silent (Sound Proof enclosure) water cooler Diesel Engine Driven Generating Set capable of delivering 58.5 KVA air cooled, 415 Volts (AC three phase, 4 wire system of supply) 50 HZ . The DG Set shall consists of alternator coupled to a matching capacity DG Set engine, through flexible coupling and mounted on common base frame with AVM with and complete with Automatic on Mains Failure (AMF) control panel standardized by manufacturer, fuel tank with mounting arrangements, draw plug, air vent inlet and outlet connection level indicator exhaust pipe all suitable for conditions at Lariakanta including PCC foundation as per manufacture instructions, anti vibration pads, including all features to comply with latest CPCB IV+ guidelines sound proof acoustic enclosure along with emission control device and comprising of followings :-
(i) Engine (Prime Mover) : Diesel Engine 1500 RPM, direct injection, multi cylinders,self/manually start four Stroke confirming to ISO 3046/BS 5514, air cooled,with first fill oil confirming IS 10002,ISO3046,BS 5514 Standrards All diesel Engines are comply with latest CPCB norms naturally turbo charged, capable of delivering adequate BHP at outdoor atmospheric conditions at Bhowali (taking all derating factor info consideration to drive alternator capable of delivering 58.5 KVA , 12/24 Volt (as per manufacturer recommendations) electric battery start, complete with fly wheel all standard fittings/fixtures as per manufacturer and including suitable panel with tachometer, lub oil temperature meter , pressure gauge and frequency meters and also including self starter system, dynamo fuel gauge electric control penal with electronic governor (ECPG) and Engine protection system (Shut down at high temperature, low lube oil, oil pressure, over speed etc) fuel tank -Electric starter motor 12V/24V as per manufacturer. -Battery charging alternator. -Fuel system with electronic governor with mechanical governor as back up. -Due spin-on fuel filter with replaceable cartridge. -Spin-on full flow lub oil filter and pump. -Residential type silencer. -Dry type replaceable paper element air cleaner. -Recovery bottle. -Lube oil cooler. - 12V maintenance free 180AH battery with led and terminal. -Flywheel and flywheel housing to shut single bearing alternator.
M&L for reinforced cement concrete 1:2:4,type BO(using 12.5 mm graded stone aggregate ) including all as per specified for making thrust block to support the pipe line complete.
S&F cast iron Non return valve of 150 mm dia complete all as specified.
S&F cast iron Non return valve of 100 mm dia complete all as specified.
SCH 'A' PART-VII (EXTERNAL ELECTRIFICATION)
Supply and spreading clean dry sand in trenches for cushioning all as specified for cable protection complete all as directed.
M&L for laying of sub class 'B' brick common burnt clay building bricks,designation 75 complete for cable for protection complete all as specified and directed by engineer in charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sqmm 3½ core complete all as directed.
S&F galvanised steel tubes 80 mm bore, light grade, with all fittings and fixed complete to walls,parapets and ceiling or laid in floors/ PCC Foundation pillar for protection of LT cable complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick, burried directly in ground (earth pit not less then 2.25m deep bellow ground level) with top edge of the plate not less then 1.5m deep below normal ground level connected to galvanised iron earth wire of 4. mm earth lead by means of bolt, nuts, washers of galvanised steel earth strip protected by and including GI pipe 40mm dia bore (light grade) and conncted to main test point as directed and including concrete pit in PCC(1:3:6) type C-1 precast RCC (1:1.5:3) type A-1 cover slab 54 x 54 cm reinforced with 4mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8mm dia TMT bar embedded in precast cover slab funnel wire mens 20mm bore GI pipe (medium grade) for watering charcoal and salt in altemate layers, including necessary excavation and earth work in any type of soil complete all as shown on electrical plate No.3 of SSR part-I complete all as specified.
Supply,install, commission and testing cubical type LT panel board Out door , manufactured by a CPRI approved factory, floor mounted, dust & vermin proof,front and rear operated door with necessary locking arrangement made of 50 x 6mm MS angle iron frame work and CRCA sheet of 3.15 mm thick duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with suitable capacity copper bus bar (1.5 times the incoming switch gear current rating) with suitable size of PVC insulated copper conductor, thimbles glands and complete all as specified and directed with the following accessories :- (Panel Board No : 01)
INCOMING: (a) MCCB 3 pole, 415 Volts,25- 100 Amps,16 KA - 01 No.
OUTGOING:(a) MCCB 4 pole, 415 Volts,63 Amps,25 KA -02 No
(b) MCB SPN , 220 Volts, 16 Amps,10 KA -02 Nos (Spare-01 No)
(c) Star delta startor for 12.5 HP along with push botton -01 Nos
(d) Star delta startor for 50 HP along with push botton -01 Nos
(e) Digital Multi functional meter (Ammeter, Volt Meter,PF and Frequency ) - 01 No.
(f) Indicator lamp (RYB) set of three - 01 Set
Supply,install, commission and testing cubical type LT panel board Out door , manufactured by a CPRI approved factory, floor mounted, dust & vermin proof,front and rear operated door with necessary locking arrangement made of 50 x 6mm MS angle iron frame work and CRCA sheet of 3.15 mm thick duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with suitable capacity copper bus bar (1.5 times the incoming switch gear current rating) with suitable size of PVC insulated copper conductor, thimbles glands and complete all as specified and directed with the following accessories :- (Panel Board No : 01)
INCOMING: (a) MCCB 3 pole, 415 Volts,25- 100 Amps,16 KA - 01 No.
OUTGOING: (a) MCCB 4 pole, 415 Volts,63 Amps,25 KA -02 No
(b) MCB SPN , 220 Volts, 16 Amps,10 KA -02 Nos (Spare-01 No)
(c) Star delta startor for 12.5 HP along with push botton -01 Nos
(d) Star delta startor for 50 HP along with push botton -01 Nos
(e) Digital Multi functional meter (Ammeter, Volt Meter,PF and Frequency ) - 01 No.
(f) Indicator lamp (RYB) (set of three) - 01 Set
M/s Dhapola Elevator and Engineering (BID ID -3300216)
Quality Builders (BID ID -3300441)
Builders Harpal (BID ID -3300355)
UTTRAKHAND BUILDERS (BID ID -3300424)
SANJAY B SHARMA (BID ID -3297529)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .