Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 0 DHANA TEJA BARARI DHANA TEJA MATHURA MATHURA UTTAR PRADESH 281005 | MATHURA | UTTAR PRADESH | 281005 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹8,750
Closing Date
16 Jan 2025, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer, EUDC-Gomtinagar, Lucknow
Superintending Engineer, EUDC-Gomtinagar, Lucknow
15-EUDC-(GN)/Lko/2024-25
2024_MVVNL_946316_5
15-EUDC-(GN)/Lko/2024-25
Open Tender
Electrical Works
Fixed-rate
180 days
EE, EUDD-Chinhat
As Per Tender Document
2 documents required · 2 mandatory
₹1,180
EE, EUTD-Gomtinagar, Lucknow
₹8,750
24 Jan 2025
8 Jan 2025
16 Jan 2025
8 Jan 2025
16 Jan 2025
8 Jan 2025
Amount
Complete Testing of 33 KV sub Station Power Transformer, 33 KV Breaker & Panel, 11 KV Breaker & Panel and capacitor Banks under jurisdiction of EUTD-Gomtinagar, Lucknow. Complete testing shall be done once half yearly or as and when required in emergency breakdowns (within guarantee period of 6 months from date of testing) All T&P's as required for above work should be provided by the contractor.
Testing of Power TF including following tests: a) Insulation test (Using 5KV Megger) b) Open circuit/Ratio & Short circuit test. c) Magnetization current test. d)Magnetization Balance test. e)Neutral & Body to Earth resistance. f)TF oil BDV Other tests including Power TF winding Resistance, WTI/OTI ( Control Cable connections), MOG, Buchholz Relay functionality, PRV, Marshalling Box panel, Relay connections and vector group test. The test should be carried out by brining testing kit and all required instruments on site by the contractor, making all necessary connection for above tests and insuring healthiness of transformers.
Testing of 33 KV Main & Line Breakers & control Panels by Primary injection set. Timing test. Testing of DC Supply Battery/Charger Testing of annunciation /indication circuits displayiing on panel. The work includes cleaning of contacts by cleaning agent like Zorik, WD-40 Etc., Relay wiring & adjustment of setting, contacts & springs by manual and protection trip command generated by reays through primary injection set. Remote/ Local operation also to be checked.
Testing of all 11 KV Incoming/Outgoing circuit breaker/panels including testing of CT ratio by primary injection set. Timing test. Testing of DC supply battery/charger. Testing of relays and its setting as per requirement. Tightening of all contacts testing of Relay & control wiring, equipment. Testing of CT, PT & metering connections & panel wiring & indicator lights.
Functionality test of all capacitor banks. Testing of all Capacitor banks in switchyard and Breaker & control panels including testing of relays and it's under & over voltage settings as per requirement. Tightening of all contacts testing of Relay & control wiring, equipment.
In case of insallation/augmentation of new power TF at substation. Testing of Power Transformer as per above point No 1.01
M/s S.K. CONSTRUCTION (BID ID -4858644)
SUNEEL KUMAR VERMA (BID ID -4858856)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .