Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.3 CrAdmitted-Finance 7 1 214 4 2ND FLOOR D K ROAD AMEERPET HYDERABAD TELANGANA 500016 | MEDCHAL MALKAJGIRI | TELANGANA | 500016 | L1 | Admitted-Finance | |
| 2 | L2₹53.5 Cr+₹4.2 Cr (8.56%)Admitted-Finance 19 LAKE TEMPLE ROAD KOLKATA 700 029 | KOLKATA | KOLKATA | WEST BENGAL | 700029 | L2 | Admitted-Finance | |
| 3 | L3₹53.6 Cr+₹4.3 Cr (8.81%)Admitted-Finance 11TH FLOOR ECO CENTRE BUSINESS TOWER P NO 4 EM BLOCK SECTOR V KOLKATA 91 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | L3 | Admitted-Finance | |
| 4 | L4₹57.0 Cr+₹7.7 Cr (15.6%)Admitted-Finance 332 TOWER A SAPZE I TECH PARK SOHNA ROAD SECTOR 49 GURUGRAM 122002 GURGAON HARYANA 122002 | GURUGRAM | HARYANA | 122002 | L4 | Admitted-Finance | |
| 5 | Not Admitted-Fee/PreQual/Technical AXIS BANK LTD A 12 MITTAL TOWAR NARIMAN POINT MUMBAI C O VOLTAS LTD VOLTAS SPARE PARTS DEPOT OLD HUTMENT COLONY SINGRAULI MP NEAR NAWANAGAR POLICE STATION | MUMBAI | MUMBAI | MADHYA PRADESH | 486887 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | UNIQUE ENGINEERS PVT. LTD. L4 | bluestar limited L3 | Shinryo Suvidha Engineers India Pvt Ltd L2 | ABS FUJITSU GENERAL PRIVATE LIMITED L1 |
|---|---|---|---|---|---|---|---|
| 1.00Section-A- Low Side HVAC works | |||||||
| 1.01CHILLED WATER EQUIPMENTS & PIPING | |||||||
| 1.02CHW EQUIPMENTS | |||||||
| 1.03CEILING SUSPENDED AHU WITH MIXING BOX - LOW STATIC TYPE | |||||||
| 1.04SITC of Ceiling suspend air handling unit with double skin construction Ceiling Suspended AHU - Low Static type using minimum 43mm thick sandwiched sheet metal panels with RPUF, density 38-42 Kg/CuM. The CSU shall be as per the specification under sections "Air Handling Units" in the tender document. Thermal break profile is required. | |||||||
| 1.05CSU shall consist of MERV-8 Pre-filter, 4 or 6 row chilled water cooling coil, fans, drive motors, isolation valve (Ball valve with strainer at inlet and without strainer at outlet) package with 2 way Control Valve, 2nos 20mm Binder test point and RA mixing box. The unit shall have suitable provision for aluminium powdercoated grill with aluminium collar dampers on the Mixing boxing for fresh air provision. Overall height of CSU shall not exceed 600mm. CSU shall have necessary arrangements to hang it from the top so as to avoid any channels or angles below the CSU. | |||||||
| 1.06The CSU's shall be sized such that the valve package consisting of isolation ball / butterfly valves, 2 Way modulating control valves, can be mounted inside the CSU casing itself. Prices to be inclusive of the valve package and including modulating thermostat. | |||||||
| 1.07All the CSU's are proposed to be mounted in corridors or other areas without false ceiling. Hence, the noise levels and aesthetics of CSU is of paramount importance. The CSU casing colour shall be 'Siemens grey' only. The aluminium structural members visible from outside and the PVC corner pieces shall also either be powdercoated / painted to match the colour of the casing. | |||||||
| 1.08The idea is to have Chilled Water CSU Units which have fans and noise level similar to DX Ductable units of leading manufacturers, but in double skin construction to further reduce noise levels. Please refer enclosed sketches for possible AHU designs worked out. In addition to TDS approval for all CSU's a Prototype for each model has to be manufactured, inspected by Client / Consultant at OEM factory for noise level and only on approval after inspection manufacture of further units can be taken up. | |||||||
| 1.09Cooling coil shall be Chilled water type with copper tubes, aluminium fins, copper header as per specifications. Fan/s shall be AMCA Certified forward/backward curved type blower with direct drive,1Ph motor its speed shall be controlled through a suitably rated variac. All maintenance panels to be preferaby accesible from the bottom for purpose of servicing or repairs. The fan outlet shall be connected to the CSU casing using fire retardant flexible connector. Prices to be inclusive of starter suitable for motor with isolator, BMS compatible with push buttons, indication lamps, selector switches etc., necessary transformer for operation of 2 way Control Valve & thermostat, provision for trip on fire alarm & Water leak detection etc. | |||||||
Tender Value
₹65.3 Cr
EMD Value
₹75.3 L
Closing Date
21 Apr 2023, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
Engineering Unit, Admin Block 3rd Floor, IIT MADRAS CHENNAI-600036
Provision of Centralized Chilled water Systems to Academic Buildings in IIT Madras SH- Provision of Low side equipment and air distribution with BMS to 19 academic buildings
2023_IITM_148676_1
26/2022-23/ELDB
Open Tender
Electrical Works
Item Rate
365 days
IIT MADRAS CHENNAI
All required documents as specified in the tender
2 documents required · 2 mandatory
₹0
₹75.3 L
Google Meet
4 May 2023
14 Mar 2023
24 Apr 2023
14 Mar 2023
21 Apr 2023
27 Mar 2023
14 Mar 2023 - 24 Mar 2023
24 Mar 2023
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Section-A- Low Side HVAC works | |||||
| 1.01 | CHILLED WATER EQUIPMENTS & PIPING | - | - | - | - |
| 1.02 | CHW EQUIPMENTS | - | - | - | - |
| 1.03 | CEILING SUSPENDED AHU WITH MIXING BOX - LOW STATIC TYPE | - | - | - | - |
| 1.04 | SITC of Ceiling suspend air handling unit with double skin construction Ceiling Suspended AHU - Low Static type using minimum 43mm thick sandwiched sheet metal panels with RPUF, density 38-42 Kg/CuM. The CSU shall be as per the specification under sections "Air Handling Units" in the tender document. Thermal break profile is required. | - | - | - | - |
| 1.05 | CSU shall consist of MERV-8 Pre-filter, 4 or 6 row chilled water cooling coil, fans, drive motors, isolation valve (Ball valve with strainer at inlet and without strainer at outlet) package with 2 way Control Valve, 2nos 20mm Binder test point and RA mixing box. The unit shall have suitable provision for aluminium powdercoated grill with aluminium collar dampers on the Mixing boxing for fresh air provision. Overall height of CSU shall not exceed 600mm. CSU shall have necessary arrangements to hang it from the top so as to avoid any channels or angles below the CSU. | - | - | - | - |
| 1.06 | The CSU's shall be sized such that the valve package consisting of isolation ball / butterfly valves, 2 Way modulating control valves, can be mounted inside the CSU casing itself. Prices to be inclusive of the valve package and including modulating thermostat. | - | - | - | - |
| 1.07 | All the CSU's are proposed to be mounted in corridors or other areas without false ceiling. Hence, the noise levels and aesthetics of CSU is of paramount importance. The CSU casing colour shall be 'Siemens grey' only. The aluminium structural members visible from outside and the PVC corner pieces shall also either be powdercoated / painted to match the colour of the casing. | - | - | - | - |
| 1.08 | The idea is to have Chilled Water CSU Units which have fans and noise level similar to DX Ductable units of leading manufacturers, but in double skin construction to further reduce noise levels. Please refer enclosed sketches for possible AHU designs worked out. In addition to TDS approval for all CSU's a Prototype for each model has to be manufactured, inspected by Client / Consultant at OEM factory for noise level and only on approval after inspection manufacture of further units can be taken up. | - | - | - | - |
| 1.09 | Cooling coil shall be Chilled water type with copper tubes, aluminium fins, copper header as per specifications.
Fan/s shall be AMCA Certified forward/backward curved type blower with direct drive,1Ph motor its speed shall be controlled through a suitably rated variac. All maintenance panels to be preferaby accesible from the bottom for purpose of servicing or repairs. The fan outlet shall be connected to the CSU casing using fire retardant flexible connector. Prices to be inclusive of starter suitable for motor with isolator, BMS compatible with push buttons, indication lamps, selector switches etc., necessary transformer for operation of 2 way Control Valve & thermostat, provision for trip on fire alarm & Water leak detection etc. | - | - | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Breakup_of_BOQ.rar
BOQ Document • 0.09 MB
BOQ_162621.xls
BOQ Document • 0.63 MB
116830712.pdf
Tender Document • 0.21 MB
TenderNo26.pdf
Tender Document • 2.10 MB
Breakup_of_BMS.rar
Tender Document • 0.13 MB
BMS_IO_Summary.rar
Tender Document • 0.12 MB
Drawings_DOMS.rar
Tender Document • 2.46 MB
Drawings_Parcel1.rar
Tender Document • 9.01 MB
Drawings_Parcel2.rar
Tender Document • 10.02 MB
Drawings_Parcel3.rar
Tender Document • 8.47 MB
Drawings_Parcel4.rar
Tender Document • 9.91 MB
Deviations.rar
Tender Document • 0.01 MB
BMS_Tech_Data_Confirmation.rar
Tender Document • 0.10 MB
Approved_Make_HVAC.rar
Tender Document • 0.01 MB
116830714.html
Tender Document • 0.04 MB
118048000.pdf
Tender Document • 0.20 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .