Er Pawan Tickoo
Executive Engineer PWD RandB Electric Div Jammu
please refer BOQ
2021_PWDJK_115120_3
e-NIT No.EDJ/151 of 2020-21 Dated 01-02-2021
Open Tender
Electrical Works
Item Rate
40 days
Ranbir Library Jammu
please refer to NIT
2 documents required · 2 mandatory
₹0
Exempted
13 Feb 2021
1 Feb 2021
12 Feb 2021
2 Feb 2021
11 Feb 2021
2 Feb 2021
120 days
Amount
Wiring for light point/ fan point/exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required. ( Group B)
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required.
Wiring for circuit/ sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required.
3 x 1.5 sq. mm
3 x 2.5 sq. mm
3 x 4 sq. mm
2C x 1.5 Sq.mm (Un Armoured)
Supplying and fixing of 10 watt LED batten fitting 2 ft long including connections etc. as required.
Supplying and fixing of surface mounted 18/20 watt LED batten tube fiiting 4 feet long including connections etc as required.
Supplying & fixing Recess/surface mounted LED 36 watt Luminarie with full diffuser (size 600mm x 600 mm).
Supplying and fixing of ceiling fan of double ball bearing type, 1200 mm sweep (5 Star rating) with 2.25 mfd condenser and down rod upto 1'-6" long on the existing fan hook with necessary connection from ceiling rose to fan using twin core copper wire.
Supplying and fixing of following sizes exhaust fan with metal blade complete set on existing holes on wall with necessary connection from ceiling rose to fan using 2 core flexible copper wire.
300 mm sweep exhust fan
450 mm sweep exhust fan (Heavy Duty)
Supplying and fixing of fan hook (U hook) on ceiling with 2 nos. of anchor fastener on both ends with necessary bolts and nuts and mansonry work as required.
Supplying and fixing of following sizes extra down rod with twin core flexible copper wire for ceiling fan. The job includes dismantling of Ceiling fan and re-installing the same as required.
Supplying and fixing 5 amps to 32 amps rating 240/415 volts "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single Pole
Single Pole and Neutral
Triple Pole and Neutral
Supplying and fixing following rating 240/415 volts "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
SPN 40 Amp.
SPN 63 Amp
TPN 40 Amp
TPN 63 Amp.
Supplying & fixing of following way single pole and netural, sheet steel, MCB distribution board, 240 volts, on surface/recess complete with tinned copper busbar netural busbar, earth bar, din bar, inter connections, powder painted including earthing etc. as required.(But without MCB/RCCB/Isolater)
12 way (Double door )
Supplying & fixing of following way horizontal type three pole and netural, sheet steel, MCB distribution board, 415 volts,on surface/recess complete with tinned copper busbar, neutral bus bar, earth bar,din bar, interconnection, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolater)
6 way (4 + 18), Double door
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (ISI Make)
Supplying & fixing of folloiwing Electrical Accessories
Celing Rose
Betten/Angle Holder
D.P 32 Amp
D.P 40 Amp
Providing and fitting of LED Bulbs.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
1 or 2 Module (75mm x 75mm)
3 Module (100mm x 75mm)
4 Module (125mm x 75mm)
6 Module (200mm x 75mm)
8 Module (125mm x125mm)
12 Module ( 200mm x 150mm)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
4 Module
6 Module
8 Module
Suplying and fixing following modular switch/ socket on the existing modular plate & switch box inculding connections but excluding modular plate etc. as required.
5/6 amp switch
15/16 amp switch
3 pin 5/6 amp socket outlet
6 pin 15/16 amp socket outlet
Bell push
Supplying and fixing (two module) stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing of change over switch of following rating.
300 Amp FP
Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board inculding drilling holes in cubicle panel, making connection etc. as required.
400 A, 50kA, FPMCCB ICU = ICS 100%
315 A, 36 kA, FPMCCB ICU = ICS 100%
160 A,36KA,FPMCCB ICU = ICS 100%
63 Amp. FP. 16 KA ICU = ICS 100%
Supplying & Drawing of Cat-6 cable.
Supplying & fixing of following Remote Bells
Call bell / Ding Dong, Single phase
Supplying installation testing and commissioning of XLPE insulated and PVC sheathed / power cable of 1.1 KV grade of following size in ground/.cable tray as per site conditions as required.
95 sq. mm 3.5 core
150 sq. mm 3.5 core
185 sq. mm 3.5 core
Supply and fixing of following LED type Street lights including connections etc as required. Complete with G.I bracket.
Supply, installation, testing & commissioning of maintenance free copper earthing system with 3 mtrs. Electrode 40 mm dia with minium 2mm thick and does not require manual additional of water. The electrode shall be pre-filled with hygroscopic powder and provided with suitable breathing and leaching ports at the ends. the electrode shall be surrounded by suitable powdered form of BEE MOIST so as to provide maximum contact between the electrode and the compund. The compound should be eco-friendly and having ROHS certification. The earthing pit should be covered with PVC cover.
Supply, installation, testing & commissioning of GI Electrode Earthing with 50mm dia and 3 meter length, with 3mm thick the electrode should be hot-dip galvinised. The GI Electrode shall be pre-filled with Cristaline Conductive Materila (CCM). The GI electrode shall be surrounded with BEE MOIST compound to provide maximum contact betwen the electrode and compound should be eco-friendly and having ROHS certification GI Electrode Earthing should be maintinance free and does not require regular manual addition of water GI Electrode shall be tested from CPRI. The earthing pit should be covered with PVC cover.
Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with suitable size of PVC insulated copper conductor cable including earthing etc. as required.
CT Set of suitable rating
Indicating Lamp
MCB Strip for 12 Nos. MCB's
Voltmeter (0-500)
Ammeter (0-100)
Alminium Bus Bar 150 amp
Alminium Bus Bar 300 amp
Alminium Bus Bar 500 amp
Alminium Bus Bar 800 amp
Supplying & fixing of following items for use in Networking system as required
Network switch 24 Port POE
24 port jack panel for termination of CAT 6
9/12 U rack( with cooling fan and power strip)
IO box Cat 6 Complete with RJ-45
1 Mtr Patch Cords
Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required.
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required
Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required
Supplying, installation, testing & commissioning of fault isolator complete with base as required.
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
SITC of ABC Type CO2 Type Fire Extinguisher
Mirza Ishtiaq Ahmed Beg and Sons
V 2 ASSOCIATES
M/S KHAN AND CO.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .