Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.5 CrAccepted-AOC | ₹3.5 Cr | L1 | Accepted-AOC Qualified |
| 2 | L2₹4.2 CrRejected-AOC | ₹4.2 Cr | L2 | Rejected-AOC Qualified |
| 3 | L3₹4.5 CrRejected-AOC | ₹4.5 Cr | L3 | Rejected-AOC Qualified |
| 4 | Rejected-Technical 53 VAISHAILI ENCLAVE SECTOR 9 INDIRA NAGAR LUCKNOW | LUCKNOW | - | - | Rejected-Technical Disqualified |
| 5 | Rejected-Technical | - | - | Rejected-Technical Disqualified |
Tender Value
₹4.5 Cr
EMD Value
₹9.1 L
Closing Date
13 Apr 2026, 3:00 pmClosed
General Manager, Zone-5
General Manager, Zone-5, U.P. Projects Corporation Ltd. Gomti Barrage, Left Bank, Gomti Nagar, Lucknow
Fire Fighting work for Girls, Boys, J.R.S.R and Auditorium for Government Medical College, Orai, District-Jalaun, (U.P.)
2026_UPPRC_1133971_1
02/UPPCL/GM-5/E-TENDER/2026-27
Open Tender
Civil Works
Percentage
270 days
District-Jalaun, (U.P.)
Fire Fighting work for Girls, Boys, J.R.S.R and Auditorium for Government Medical College, Orai, District-Jalaun, (U.P.)
2 documents required · 2 mandatory
₹17,700
₹9.1 L
21 Jul 2026
8 Apr 2026
13 Apr 2026
8 Apr 2026
13 Apr 2026
8 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Fire Fighting work for Girls, Boys, J.R.S.R and Auditorium for Government Medical College, Orai, District-Jalaun, (U.P.) | - | - | - | - |
| 2 | OVER HEAD WATER TANK (civil work) 10 Nos. | - | - | - | - |
| 3 | Providing and laying in position ready mixed or sitebatched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana /Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement..All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum R.C.C. work in slab (A) Ground Floor | - | CUM | - | - |
| 4 | Providing and laying in position ready mixed or sitebatched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana /Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement..All works above plinth level upto floor V level Concrete of M25 grade with minimum cement c ontent of 330 kg /cum R.C.C. work in Beam (A) Ground Floor | - | CUM | - | - |
| 5 | Providing and laying in position ready mixed or sitebatched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana /Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement..All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum R.C.C.work in column (A) Ground Floor | - | CUM | - | - |
| 6 | TMT Fe-500 iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. (A) Ground Floor | - | QTL | - | - |
| 7 | First Floor | - | QTL | - | - |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Columns,Pillars, Piers, Abutments, Posts and Struts. | - | SQM | - | - |
| 9 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. | - | SQM | - | - |
| 10 | Suspended floors, roofs, landings, balconies and access platform. | - | SQM | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 11.29 MB
BOQ_2116691.xls
BOQ • 0.92 MB
BID1.pdf
Tender Documents • 8.17 MB
Corrigendum.pdf
PDF • 0.48 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].