| 1 | L1₹18.1 LAccepted-AOC D 35 NEAR CLOCK TOWER HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | ₹18.1 L Quoted ₹18.9 L | L1 | Accepted-AOC AOC |
| 2 | L2₹21.7 LRejected-Finance | ₹21.7 L | L2 | Rejected-Finance Not being lowest. |
| 3 | L3₹23.2 LRejected-Finance | ₹23.2 L | L3 | Rejected-Finance Not being lowest. |
| 4 | L4₹32.8 LRejected-Finance | ₹32.8 L | L4 | Rejected-Finance Not being lowest. |
| Sl No | Description | Qty | Unit | Auto Traders L3 | m/s rudraksh enterprises L1 | ms shrilaxminarayan and sons L4 | Swasti Electricals L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully copper / aluminium point wiring (light, fan, sockets or power) complete including all fittings and fixtures such as switches, sockets, ceiling roses, pendens, regulators, light fittings etc, removing materials to store for taking credit and making good disturbed surfaces complete all as specified and directed. | 1,960 | Point | 10 ₹19,600 | 5 ₹9,800 | 20 ₹39,200 | 16 ₹31,360 |
| 2.00 | M&L point wiring with 1.5 sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including non-metallic, rigid non metallic PVC conduit (medium grade) concealed in wall / ceiling with and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel modular terminal boxes any size/module, concealed on walls and fixed by means of brass screws incl modular cover plates and cover frame any size/module and blank plates, for mounting or housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for one light / fan / exhaust fan / call bell point controlled by one 5 / 6 Amps switch, complete incl making good of wall surface by cementing/plastering , applying wall putty incl 02 coat of distempering to match with the existing colour all as specified and directed. | 860 | Point | 550 ₹4,73,000 | 430 ₹3,69,800 | 700 ₹6,02,000 | 430 ₹3,69,800 |
| 3.00 | Description all as per ser item No. 2.00 above but for one 3 pin, 5/6 Amps socket outlet point on same board controlled by one, 1 way 5/6 Amps switch | 100 | Point | 150 ₹15,000 | 110 ₹11,000 | 250 ₹25,000 | 160 ₹16,000 |
| 4.00 | Description all as per ser item No. 2.00 above but for one 3 pin, 5/6 Amps socket outlet point on independent board controlled by one, 1 way 5/6 Amps switch. | 200 | Point | 550 ₹1,10,000 | 430 ₹86,000 | 700 ₹1,40,000 | 450 ₹90,000 |
| 5.00 | Description all as per ser item No. 2.00 above but for one light point controlled by one, 2 way 5/6 Amps switch. | 20 | Point | 610 ₹12,200 | 440 ₹8,800 | 700 ₹14,000 | 480 ₹9,600 |
| 6.00 | M&L point wiring with 2.5 sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including non-metallic, rigid non metallic PVC conduit (medium grade) concealed in wall / ceiling with and including 2.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel modular terminal boxes any size/module, fixed concealed in walls by means of brass screws incl modular cover plates and cover frame any size/module, for housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for 15 / 16 Amps socket outlet on independent board, complete incl making good of wall surface by cementing/plastering , applying wall putty incl 02 coat of distempering to match with the existing colour all as specified and directed. | 60 | Point | 725 ₹43,500 | 530 ₹31,800 | 900 ₹54,000 | 510 ₹30,600 |
| 7.00 | M&L point wiring with 1.5 sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through PVC casing and caping of suitable sizes (medium grade ISI marked) in wall / ceiling with and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel modular terminal boxes any size/module, concealed on walls and fixed by means of brass screws incl modular cover plates and cover frame of any size/module, for mounting or housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for one light / fan / exhaust fan / call bell point controlled by one 5 / 6 Amps switch, complete incl making good of wall surface by cementing/plastering , applying wall putty incl 02 coat of distempering to match with the existing colour all as specified and directed. | 400 | Point | 490 ₹1,96,000 | 410 ₹1,64,000 | 600 ₹2,40,000 | 430 ₹1,72,000 |
| 8.00 | Description all as per ser item No. 7.00 above but for one 3 pin, 5/6 Amps socket outlet point on same board controlled by one, 1 way 5/6 Amps switch. | 80 | Point | 125 ₹10,000 | 100 ₹8,000 | 140 ₹11,200 | 160 ₹12,800 |
| 9.00 | Description all as per ser item No. 7.00 above but for one 3 pin, 5/6 Amps socket outlet point on independent board controlled by one, 1 way 5/6 Amps switch. | 120 | Point | 490 ₹58,800 | 410 ₹49,200 | 700 ₹84,000 | 450 ₹54,000 |
| 10.00 | Description all as per ser item No. 7.00 above but for one light point controlled by one, 2 way 5/6 Amps switch. | 20 | Point | 575 ₹11,500 | 410 ₹8,200 | 700 ₹14,000 | 480 ₹9,600 |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
27 Dec 2025, 6:00 pmClosed
GE AWC MHOW
GE AWC MHOW
REPLACEMENT REPAIR AND MAINT OF UNSERVICEABLE EXISTING WIRING, UNSERVICEABLE DBs, FITTINGS AND FIXTURES, EARTHING ETC AT MD OTM ACCN OF 11 JAK LI, EME WKSP, GEN BUNGLOWS, ARO AND MAINT REPLACEMENT AND REPAIR OF EXISTING UNSERVICEABLE SUB MAIN WIRING
2025_MES_742221_1
8896/(AWC) /MHOW / OF 2025-26
Open Tender
Electrical and Maintenance Works
180 days
GE AWC MHOW
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AWC MHOW
₹99,000
3 Feb 2026
29 Nov 2025
29 Dec 2025
29 Nov 2025
27 Dec 2025
13 Dec 2025
Amount
Taking down carefully copper / aluminium point wiring (light, fan, sockets or power) complete including all fittings and fixtures such as switches, sockets, ceiling roses, pendens, regulators, light fittings etc, removing materials to store for taking credit and making good disturbed surfaces complete all as specified and directed.
M&L point wiring with 1.5 sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including non-metallic, rigid non metallic PVC conduit (medium grade) concealed in wall / ceiling with and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel modular terminal boxes any size/module, concealed on walls and fixed by means of brass screws incl modular cover plates and cover frame any size/module and blank plates, for mounting or housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for one light / fan / exhaust fan / call bell point controlled by one 5 / 6 Amps switch, complete incl making good of wall surface by cementing/plastering , applying wall putty incl 02 coat of distempering to match with the existing colour all as specified and directed.
Description all as per ser item No. 2.00 above but for one 3 pin, 5/6 Amps socket outlet point on same board controlled by one, 1 way 5/6 Amps switch
Description all as per ser item No. 2.00 above but for one 3 pin, 5/6 Amps socket outlet point on independent board controlled by one, 1 way 5/6 Amps switch.
Description all as per ser item No. 2.00 above but for one light point controlled by one, 2 way 5/6 Amps switch.
M&L point wiring with 2.5 sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including non-metallic, rigid non metallic PVC conduit (medium grade) concealed in wall / ceiling with and including 2.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel modular terminal boxes any size/module, fixed concealed in walls by means of brass screws incl modular cover plates and cover frame any size/module, for housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for 15 / 16 Amps socket outlet on independent board, complete incl making good of wall surface by cementing/plastering , applying wall putty incl 02 coat of distempering to match with the existing colour all as specified and directed.
M&L point wiring with 1.5 sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through PVC casing and caping of suitable sizes (medium grade ISI marked) in wall / ceiling with and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel modular terminal boxes any size/module, concealed on walls and fixed by means of brass screws incl modular cover plates and cover frame of any size/module, for mounting or housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for one light / fan / exhaust fan / call bell point controlled by one 5 / 6 Amps switch, complete incl making good of wall surface by cementing/plastering , applying wall putty incl 02 coat of distempering to match with the existing colour all as specified and directed.
Description all as per ser item No. 7.00 above but for one 3 pin, 5/6 Amps socket outlet point on same board controlled by one, 1 way 5/6 Amps switch.
Description all as per ser item No. 7.00 above but for one 3 pin, 5/6 Amps socket outlet point on independent board controlled by one, 1 way 5/6 Amps switch.
Description all as per ser item No. 7.00 above but for one light point controlled by one, 2 way 5/6 Amps switch.
M&L point wiring with 2.5 sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including rigid,non-metallic PVC casing and caping (medium grade) on wall / ceiling with and including 2.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel modular terminal boxes any size/module, fixed concealed in walls by means of brass screws incl modular cover plates and cover frame any size/module, for housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for 15 / 16 Amps socket outlet on independent board, incl making good of wall surface by cementing/plastering , applying wall putty incl 02 coat of distempering to match with the existing colour all as specified and directed. complete all as specified and directed.
S&F in replace Ceiling rose 3 terminal AC 230 V, 50 Hz ISI Marked all as specified and directed.
S&F in replace modular switch 1 way 6A, 1 module, ISI Marked complete all as specified and directed.
S&F in replace modular switch 2 way 6A, 1 module, ISI Marked complete all as specified and directed.
S&F in replace modular bell push one way, 5/6 Amp, 240 V ISI Marked complete all as specified and directed.
S&F in replace modular switch 1 way 16A, 1 module, ISI Marked complete all as specified and directed.
S&F modular socket outlet, 6A - 2/3 pin combined 2 module, ISI Marked complete all as specified and directed.
S&F modular socket multipurpose 6/16A, 2 module, ISI Marked complete all as specified and directed.
S&F stepped type electronic modular fan regulator - 2 module, with 5 step, AC 50 Hz, 230/240 Volts grade, ISI Marked complete all as specified and directed.
S&F call bell, ding dong, AC 230 V, 50 Hz complete all as specified and directed.
S&F TV socket outlet ISI Marked complete all as specified and as directed.
S&F RJ 11 /RJ 45 LAN jack with shutter ISI Marked complete all as specified and as directed.
S&F modular type angular lamp holder, PVC / Polycarbonate fancy type with back plate 230 V, 50 Hz including taking down complete all as specified and as directed.
S&F in replacement of pendent lamp holder, brass body for decorative wall fittings complete with mounting clamp (as per sample) for fixing inside wall mounted luminaire 240 volt complete all as specified and as directed.
S&F in replacing metal plug and socket DB concealed in wall, double pole 240 volts and including one 20 Amp MCB SPN, C-Curve, ISI Marked complete incl making good of disturbed surface by plastering, painting, applying putty all as specified and directed.
S&F in replacing 9 watt LED lamp warm white(5 star rated) with B22 base including taking down complete all as specified and as directed.
S&F in replacing 9 watt LED lamp warm white(5 star rated) threaded with B22 base including taking down complete all as specified and as directed.
S&F in replacing decorative ultra slim poly carbonate LED tube light fitting 4 feet long 22 watts with THD less than 15% very high efficiency suited for T-8 tube light luminaire with system efficiency 110 lumens per watts. High quality polycarbonate end cap in white finish and snap fitted to the housing complete all as specified and directed.
S&F in replacing wall mounted 10 watts LED batten 2 feet long comprising extruded aluminium heat shrink provided for efficient heat dissipation & integrated electronic driver with aluminium housing system efficiency of 110 lumen per watt and lumen package ≥1100 lumen, THD < 10% complete all as specified and directed.
S&F VTPN DB, 04 way, IP- 43, IK 09, double door type with metal door, suitable for fixing up to 3 pole 160 Amp MCCBs as incomer and SP/TP MCB/Isolator as outgoing, including taking down, fixing flush to wall & making good the disturbed surfaces complete all as specified and as directed.
S&F MCB DB, TPN 4 way, IP-43, IK 09, double door type with metal door, 415 V, 50 Hz, suitable for fixing MCB TPN as incomer and SP/TP MCB/Isolator as outgoing, including taking down old DB with MCBs, fixing flush to wall & making good the disturbed surfaces complete all as specified and as directed.
S&F MCB DB, SPN 8 way, IP-43, IK 09, double door type with metal door, 230 V,50 Hz suitable for fixing MCB SPN as incomer and SP MCB/Isolator as outgoing, including taking down old DB with MCBs, fixing flush to wall & making good the disturbed surfaces complete all as specified and as directed.
S&F MCCB 3 pole 160 Amps breaking capacity 25 KA, Ics = 100% Icu including spreader link & taking down complete all as specified and directed.
S&F in replace MCCB 3 pole 100 Amps breaking capacity 25 KA, Ics = 100% Icu including spreader link & taking down complete all as specified and directed.
S&F MCB TPN 32 Amps,10 KA breaking capacity, 'C' curve complete all as specified and directed.
S&F MCB TPN 63 Amps,10 KA breaking capacity, 'C' curve complete all as specified and directed.
S&F MCB SPN 20 to 32 Amps,10 KA breaking capacity, 'C' curve complete all as specified and directed.
S&F MCB SPN 40 Amps,10 KA breaking capacity, 'C' curve complete all as specified and directed.
S&F MCB SP 6 to 32 Amp, 10 kA breaking capacity, 'C' curve complete all as specified and as directed.
M&L for MCB two way centre off change over switch 40 Amps, for duel electricity supply management complete all as specified and directed.
M&L for flexible wire twisted 23/0076 of size 1.5 sq. mm for replacing from ceiling rose to light fittings/ceiling fan/exhaust fans complete all as specified and directed.
S&F in replace 3 core copper flexible cable 2.5 sqmm complete all as specified and directed.
M&L for replacement of FRP junction box three terminal and neutral with one MCB SP 20 A for control of security light / garden light / gates / post top lantern incl making good of PCC and finishing with cement rendering complete all as specified and directed.
M&L for Blank Plate 01 Module complete all as specified and directed.
Supply and fixing round plate PVC as existing size all as specified and directed.
M&L for replacing change over MCB 4 pole 63 Amps, 415 volts, 50 Hz all as specified and as directed.
Supply only cross flow fan, 200mm sweep metallic body as per sample all as specified and directed.
M&L for replacing GI tubings 50 mm size light grade for cable protection/stand post of garden lights incl welding bending complete all as specified and directed.
M & L sub main wiring with 2 runs of 6 sqmm main wire along with 1 run of 6 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC concealed / surface conduit (medium grade) wherever necessary with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good the same & taking down complete all as specified and directed. NOTE:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length.
M&L in replacement earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground in vertical position (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to GI earth wire 4 mm dia by means of bolts, nuts, check nuts and washers of , all as shown in electrical plate No. 3 connected to earthing test point and complete all as specified and directed. Note:- The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C-1 (using 20 mm grade crushed stone aggregate) earth chamber, RCC 1:1.5:3, type A-1 cover slab, 40 mm thick reinforced with 6 mm dia TMT bar @ 150 mm C/C both ways, 10 mm dia plain bar lifting handle embedded in cover slab, 20 mm bore medium grade GI watering pipe, 15 mm bore GI light grade earth lead protection pipe, funnel, wire mesh, copper lugs, charcoal and common salt in alternate layer etc.
S & F digital type single phase electric energy meter 230 volt 10 amp to 60 amp all as specified and directed by engr-in-Charge
S & F digital type single phase electric energy meter 230 volt 10 amp to 30 amp all as specified and directed by engr-in-Charge
Swasti Electricals (BID ID -3509110)
Auto Traders (BID ID -3502367)
ms shrilaxminarayan and sons (BID ID -3504059)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.17 MB
Tdocus.pdf
Tender Documents • 0.77 MB
BOQ_831128.xls
BOQ • 0.32 MB
makelist8896.pdf
Tender Documents • 0.53 MB
Download all tender documents and submit your bid