Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical ok |
| 2 | Accepted-Technical 368 369 2ND FLOOR BASANT BUILDING CHAUDHARY MARKET SULTANPUR SOUTH WEST DELHI DELHI 110030 | SOUTH DELHI | DELHI | 110030 | Accepted-Technical ok |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
27 Nov 2025, 11:30 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer Mech and Hosp Division Udhampur
XEN MHD UDHAMPUR
CAMC of Medical Gas Pipeline System (MGPS) at Associated Hospital, GMC Udhampur
2025_PWDJK_294181_1
MHDU/TS/2025-26/70
Open Tender
Machineries/ Mechanical Engg Items
Item Wise
15 days
AH GMC UDHAMPUR
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
Executive Engineer Mech and Hosp Division Udhampur
₹20,000
XEN MHD UDHAMPUR
12 Dec 2025
4 Nov 2025
27 Nov 2025
4 Nov 2025
27 Nov 2025
5 Nov 2025
10 Nov 2025
CAMC ofof Air Compressors of MGPS at Associated Hospital GMC Udhampur by means of Servicing of Reciprocating type Air Compressors (02 nos.) each of capacity 60 CFM (MAKE: ANEISTA IWATA) by way of replacement of piston rings set-01 set each, Suction disc valve set-01 set each, Air filter Set-01 set each, Gaskets-01 set each, Oil -05 litres each etc, including complete checking after repairs thereof. CAMC includes general check-up visits for trouble free operation of MGPS and to take necessary preventive steps to eliminate/reduce breakdowns time of plant. It includes complete servicing of all the equipment’s (daily/monthly/quarterly/half yearly/9 months/ annually/preventive maintenance) whenever required. CAMC also includes repairs of any part of MGPS which may develop defect, to make it functional and it is to be ensured that the efficiency of the plant remains up to the mark. If the defect in any part is non repairable or if on repairs of any part, the efficiency of the plant is under par, the defective part is to be replaced by the new one. The rates are inclusive of all charges for works involved in CAMC (01 year) and all kind of taxes as applicable.
CAMC of Vacuum pumps (02 nos.) each (MAKE: ANEISTA IWATA) by replacement of piston rings set-01 set each, Suction disc valve set-01 set each, Gaskets-01 set each, Oil -05 litres each etc, including complete checking after repairs thereof. CAMC includes general check-up visits for trouble free operation of MGPS and to take necessary preventive steps to eliminate/reduce breakdowns time of plant. It includes complete servicing of all the equipment’s (daily/monthly/quarterly/half yearly/9 months/ annually/preventive maintenance) whenever required. CAMC also includes repairs of any part of MGPS which may develop defect, to make it functional and it is to be ensured that the efficiency of the plant remains up to the mark. If the defect in any part is non repairable or if on repairs of any part, the efficiency of the plant is under par, the defective part is to be replaced by the new one. The rates are inclusive of all charges for works involved in CAMC (01 year) and all kind of taxes as applicable.
CAMC of of damaged parts of Heatless Desiccant Dryer (02 no.) (MAKE:Trident) by way of replacement of Alumina ,3mm of required quantity(each dryer ), Solenoid valve -01 set each , Controller-01 set each , Replacement/repair of 3 stage filteration system (Line filters)-01 complete set each .Complete checking of the system after repairs. CAMC includes general check-up visits for trouble free operation of MGPS and to take necessary preventive steps to eliminate/reduce breakdowns time of plant. It includes complete servicing of all the equipment’s (daily/monthly/quarterly/half yearly/9 months/ annually/preventive maintenance) whenever required. CAMC also includes repairs of any part of MGPS which may develop defect, to make it functional and it is to be ensured that the efficiency of the plant remains up to the mark. If the defect in any part is non repairable or if on repairs of any part, the efficiency of the plant is under par, the defective part is to be replaced by the new one. The rates are inclusive of all charges for works involved in CAMC (01 year) and all kind of taxes as applicable.
Complete job for 220 beds of various sections of the hospital for complete period of CAMC. a) Repair/Replacement of damaged/worn out Oxygen flow meters along with humidifier bottles, Ward vacuum units/Jars PB/BS type (as per requirement) Complete servicing/replacement of Gas outlet points(Oxygen, vacuum, Compressed Air, Nitrous Oxide)with HP tubes b) Repair/ replacement of Isolation valves (if any), Theatre Suctions units, SS basket vacuum slider. c) Repair/servicing to Oxygen Manifold system (9+9)-02 no., Nitrous Oxide Manifold system (5+5)-01 no., by way of replacement of damaged NRVs, pig tail pipes, Solenoid switches, Pressure regulator (10 bars) of required no.( if any). Also repair of Standy Manual Oxygen Manifol(5+5) by way of replacement of NRV , Pressure Regulating Valve, Pressure Guage. d) Repair/Replacment to Auto Cascading control panel for Compressed Air and Vacuum System by way of replacement of defective PLC (Programmable logic controller), wiring, MCCB, defective relays. Complete checking and servicing of the panel. e) Repair/replacement of defective Gas alarm system (2/3/4 gas type) by way of servicing of damaged ones and replacement of the unservicables. f) Complete checking of the isolation boxes (2/3/4 gas type) installed in various wards/sections of the hospital along with checking and replacement of damaged Isolation valves/pr. gauges(2/3/4 gas type), h) Also repair/replacement to leakages in copper pipeline including replacement of damaged saddles/clamps from MGPS plant room to bed end Replacement of any damaged electrical fittings(Ceiling lights, switches, sockets,wiring) inside the MGPS plant room. CAMC includes general check-up visits for trouble free operation of MGPS and to take necessary preventive steps to eliminate/reduce breakdowns time of plant. It includes complete servicing of all the equipment’s (daily/monthly/quarterly/half yearly/9 months/ annually/preventive maintenance) whenever required. CAMC also includes repairs of any part of MGPS which may develop defect, to make it functional and it is to be ensured that the efficiency of the plant remains up to the mark. If the defect in any part is non repairable or if on repairs of any part, the efficiency of the plant is under par, the defective part is to be replaced by the new one. The rates are inclusive of all charges for works involved in CAMC (01 year) and all kind of taxes as applicable.
CAMC of Automatic Voltage Regulator (40 KVA) MAKE: JAIMA viz. MCCB, ACBs, LT control panel, manual changeover,worn out/burnt out cabling . Repair/servicing of DG set (50 KVA) with inbuilt AMF panel of MGPS by way of complete oil change along with filters and allied works.(MAKE: HARRISON). CAMC includes general check-up visits for trouble free operation of MGPS and to take necessary preventive steps to eliminate/reduce breakdowns time of plant. It includes complete servicing of all the equipment’s (daily/monthly/quarterly/half yearly/9 months/ annually/preventive maintenance) whenever required. CAMC also includes repairs of any part of MGPS which may develop defect, to make it functional and it is to be ensured that the efficiency of the plant remains up to the mark. If the defect in any part is non repairable or if on repairs of any part, the efficiency of the plant is under par, the defective part is to be replaced by the new one. The rates are inclusive of all charges for works involved in CAMC (01 year) and all kind of taxes as applicable.
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.19 MB
BOQ_951692.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .