Executive Engineer R.C.D Road Division, Jamshedpur
Executive Engineer R.C.D Road Division, Jamshedpur
IIRQP work of Jamshedpur town area(A) Birsanagar Sadhu dera to Sisu Mandir Road, 10 Bed Hospital to Chinmaya School Road, Jhanda Chowk to Hanuman Mandir Road, Birsanagar 1 B Main Road and Road No.II (Length 4.6 km ), (B) Birsanagar Laal Tand to Kalim
2023_CECOM_78437_1
RCD/JAMSHEDPUR/1972/2023-24
Open Tender
Civil Works
Item Rate
180 days
BIRSANAGAR
Please refer Tender documents.
3 documents required · 3 mandatory
₹10,000
₹9.6 L
14 Jun 2024
6 Dec 2023
28 Dec 2023
6 Dec 2023
26 Dec 2023
6 Dec 2023
Amount
(RCD SOR- 2.03 (ii) A ) Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, sapling and tress girth upto 300 mm, removal of stumps of tree cut earlier and disposal of unserviceable materials and stacking of sericeable material to be used of auctioned, up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150mm in thickness.
(RCD SOR-2.06 ) Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a alead of 1000 metres, stackiung serviceable and unserviceable materials separately
RCD SOR-3.06) Excavation for road work in soil with hydraulic excavator including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and tranporting to the embankment location within all lifts and lead upto 1000 m
RCD SOR- 3.19 ) Construction of Embankment with Material Deposited from Roadway Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Table 300-2.
RCD SOR-4.01 AB (v) ) Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with front end loader at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401.Rate per cum for grading-V Material
RCD SOR-4.14 B ) Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with grader in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.
RCD SOR-6.01 Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.
RCD SOR-13.05 C ) Plain/Reinforced cement concrete in sub-strucutre complete as per drawing and Technical specificationsPCC Grade M25 using batching plant, transit mixer & concrete pump
RCD SOR-6.02 Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with approve grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing
RCD SOR-5.01 A (i) Providing and applying primer coat with SS1 grade bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 kg/sqm using mechanical means.
RCD SOR-5.02 (iii) Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom.
RCD SOR-5.02 (i) )Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.20 kg per sqm on the prepared bituminous surface cleaned with mechanical broom.
RCD SOR-5.04 B ) Providing and laying dense graded bituminous macadam with higher capacity batch type HMP using crushed aggregates of specified grading, premixed with bituminous binder @4.5 percent by weight of total mix and filler, transporting the hot mix to work site laying with a hydrostatic paver finisher with sensor control to the required grade level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORT&H specification clause no. 505 complete in all respects.
RCD SOR-5.05 B) Bituminous concrete Grading- II with VG-30 Grade Bulk Bitumen . Providing and laying bituminous concrete with higher capacity batch type hot mix plant using crushed aggregates of specified grading, premixed with bituminous binder @5.4 percent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment , rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORT&H specification clause no. 507 complete in all respects.
RCD SOR-8.13 ) Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface (Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.)
RCD SOR-8.04 (ii) Retro-Reflectorised Traffic Signs, 90 cm equilateral triangle Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of class-B Type IV retro reflective sheeting fixed cover 2 mm thick aluminium sheeting vide clause 801.3, 3mm/4mm thick aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25 x 25 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC 67.
RCD SOR-8.04 (viii) Retro-Reflectorised Traffic Signs, 60 cm circular . Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of class-B Type IV retro reflective sheeting fixed cover 2 mm thick aluminium sheeting vide clause 801.3, 3mm/4mm thick aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25 x 25 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC 67.
RCD SOR-8.04 (x) Retro-Reflectorised Traffic Signs, 80 cm x 60 cm rectangular .Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of class-B Type IV retro reflective sheeting fixed cover 2 mm thick aluminium sheeting vide clause 801.3, 3mm/4mm thick aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25 x 25 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC 67.
RCD SOR- 15.03 Sand Filling in Foundation Trenches as per Drawing and Technical Specification
(RCD SOR- 4.23 B amendment) Providing and laying 80mm thick factory made cement concrete interlocking paver block of M-40 grade made by block making machine with strong vibratory compaction of approved size, design and shape, laid in required colour and pattern over bed as per relevent IRC -code filling the joints with fine sand etc, all complete job as per direction of engineer -in- charge.
RCD SOR-2.04 (i) II A ) Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concree, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with allk lifts and lead of 1000 metres. Lime/ Cement concrete, By Mechanical means , Cement Concrete Grade M-15 & M-20
RCD SOR-2.04 (ii) B ) Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concree, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with allk lifts and lead of 1000 metres. Dismantling Brick/ tile work , By Manual means, In cement mortar
RCD SOR-13.01 ) Brick masonry work in 1:3 in substructure complete excluding pointing and plastering, as per drawing and Technical Specifications
RCD SOR-13.03 ) Plastering with cement mortar (1:3) on brick work in substructure as per technical specifications
RCD SOR-12.01 B(i) ) Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
RCD SOR-12.08(A) ) Plain/Reinfoced Cement concrete in open foundation complete as per drawaing and technical specifications.PCC grade M-15 using batching plant and concrete mixture
RCD SOR-13.05 E (p) ) Plain/Reinforced cement concrete in sub-strucutre complete as per drawing and Technical specifications RCC grade M-20 using batching plant , concrete mixture and concrete pump.
RCD SOR-13.05 G (p) ) Furnishing and Placing Reinforced/ Prestressed cement concrete in super-structure as per drawing and Technical Specification RCC grade M-30 using batching plant , concrete mixture and concrete pump.
RCD SOR-13.06 ) Supplying, fitting and placing HYSD bar reinforcement in sub structure complete as per drawing and technical specifications
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres. All complete job as per MoRTH specification cl. 202, 2.4(iii) B & direction of E/I Stone Masonary 2.04 (iii)
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres. All complete job as per MoRTH specification cl. 202, 2.4(iii) B & direction of E/I .RCC/PCC 2.04 B
(12.01) Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
(12.08 A ) PCC M-15 Plain/Reinfoced Cement concrete in open foundation complete as per drwaing and technical specifications.
(12.07 B)Stone masonry work in cement mortar 1:3 in foundation complete as per drawing and technical specifications.
(13.04 A) Stone masonry work in cement mortar 1:3 for substructure complete as per drawing and technical specifications
RCD SOR-13.05 C ) Plain/Reinforced cement concrete in sub-strucutre complete as per drawing and Technical specificationsPCC Grade M25 using batching plant, transit mixer & concrete pump bed plate +Deck slab
RCD SOR-14.04 Providing laying and finishing cement concrete grade M30 for wearing coat over R.C.C. deck slab and approach slab complete as per drawing, design, MOSRTH&H specification Spl. Cl. No. 2201.3 and direction of E/I.
RCD SOR-14.04 .Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6 per cent bitumen by weight
RCD SOR-13.05 B (p) . Plain/Reinforced cement concrete in sub-strucutre complete as per drawing and Technical specifications PCC M 20
RCD SOR-13.06 ) Supplying, fitting and placing HYSD bar reinforcement in sub structure complete as per drawing and technical specifications
RCD SOR-13.09 ) Back filling behind abutment, wing wall, return wall complete as per drawing and technical specifications
RCD SOR-13.08 ) Providing weep holes in Brick masonry/ Plain/Reinforced concrete abutment , wing wall/ returen wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V:20 H towards drawing face. Complete as per drawing and technical specifications.
RCD SOR-13.10 ) Providing and laying of filter media with granular materials/stones crushed aggregates satisfying the requirements laid down in clause 2504.2.2 of MoRT&H specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment , wing wall and return wall to the full height compacted to a firm condition complete as per drwaing and technical specification.
Add 18% GST :
Add 1% Labour Cess:
NNB ENGINEERS PRIVATE LIMITED
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .