Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.8 LAccepted-AOC WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹45.0 L+₹1.0 L (2.36%)Rejected-Finance 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L2₹49.7 L+₹5.8 L (13.1%)Rejected-Finance NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | L2 | Rejected-Finance BEING NOT LOWEST | |
| 4 | L4₹61.0 L+₹17.1 L (38.8%)Rejected-Finance A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | L4 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹45.2 L
EMD Value
₹90,500
Closing Date
15 Sept 2021, 6:00 pmClosed
ARJUN PATRO,IDSE
GE U ELECTRIC SUPPLY,DELHI CANTT
PROVISION OF HT CABLES FOR HT 11 KV SECOND SUPPLY FROM AOC SUB STN TO DENTAL OFFICER MESS, PROVISION OF VCB, BUS COUPLER AND HT 11 KV SECOND SUPPLY FROM 17 SIKH LI UNIT TO MAP NARAINA SUB STN NO 1 AND ADDITION ALTERATION OF LT UNDERGROUND CABLE, LT
2021_MES_468396_1
GE ELECT/D-72/2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE U ELECTRIC SUPPLY
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE U ELECTRIC SUPPLY
₹90,500
Yes
27 Sept 2021
17 Aug 2021
22 Sept 2021
18 Aug 2021
15 Sept 2021
3 Sept 2021
Amount
Excavation in trenches not exceeding 1.5 meters wide & not exceeding 1.5 meters in depth for laying of cable and getting out in soft/loose soil including trimming the sides forming bottom surfaces to required level complete all as specified and as directed by Engineer-in-charge.
Returning, filling in including spreading leveling, watering and well ramming in layers not exceeding 25 cms thick in each layer of soil complete all as specified.
Removing excavated material to a distance n.exc 50 meters and depositing where directed at a level not exceeding 1.5 mtrs above the starting point all as specified and directed by Engineer-in-Charge.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables, filling in existing Cable duct in side the sub station situated at different location for cushioning of cables and sand filling under floors or in foundations of transformers including watering and consolidation etc, complete all as specified. NOTE:-Measuement shall be taken after punning down.
Supply and laying factory made non-reinforced precast concrete cable cover class HV type-I with size 300mmx180mmx40mm all as specified and directed.
Supply and laying XLPE insulated, screened, PVC bedded steel strip/wire armoured heavy duty electric cable suitable for 11KV earthed system of cross sectional area 3 core 120 Sq mm.
S&F Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of following size
3 core 240 sqmm.
3 core 120 sqmm
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (Earth pit not less than 3.5 meter deep below ground level) with top edge of plate not less than 2.5 meter below normal ground level, connected with and including galvanised iron earth strip 25 X 3mm by means of nuts, bolts, check nuts and washers of galvanised iron or steel and provisions of charcoal dust and common salt packed all around the earth plate and testing on completion complete all as specified, directed and shown in Electrical Plate number 3 of MES SSR Part-I 2009. NOTES : The quoted rates shall be deemed to include the cost of (a) Excavation and earth work in any type of Soil. (b) PCC pit in cement concrete 1:3:6 mix, type B-1, Pre cast RCC cover with suitable handle, 40 mm thick in RCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/Sq metre. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc (d) 40 mm nominal bore medium grade GI protection pipe 7.50 m long for protection of earthing lead (e) Requisite quantity of common salt and charcoal in alternate layers completely packed as directed. (f) Testing of earthing on completion.
M&L for Brick Masonry ( Using sub class 'B' Brick) platform of size 2m x 2m x 1 m hight , built in CM 1:4 complete with excavation & earth work , PCC 1:4:8 type D-2 in foundation , sub class 'B' brick work in CM 1:, 15 mm thick rendering in CM 1:6 on sides and top of the brick work , upto 150 mm below ground level , supply and fixing of 02 Nos MS Chennels of suitable size for balancing of Transformer embedded in PCC 1:2:4 type B-1 up to 100 mm Thick RCC 1:3:6 with 10 mm steel bar includding 20 mm graded aggregate , including provn of stair case on one side complete all as specified and directed .
Disconnecting electric outdoor transformer 11 KV capacity up to 500 KVA from HT/LT terminals and lifting by hydra for installation on nely constructed plinth 2/4 pole structure complete all as specified and directed .
M/L for HDPE pipe,of size 160 mm dia suitable for 4 kgf/cm 2 working pressurewith all fitting , laid in trenches for protection of cable in road /drain crossing complete all as specified and as directed.
Horizontal boring holes upto 2 m deep in soil for laying GI pipes and getting out and disposal of spoil to a distance of n exc. 50 m up to 200 mm bore complete . Note:- The HDPE Pipes should be measured and paid separately under nItem No 11 here in before.
M&L for perimeter fencing of size 25m x 18m x 2m (as per site condition) having MS work of angle iron for post and struts of fencing around the transformer plinth/substation/LT panels etc drilling holes flat iron fillet for securing wire mess by welding to angle iron frame and framed work as in door/gate of angle iron and wiremesh.Door to be fixed by 03 nos 100mm long hinges and one sliding door bolt of 300mm long for locking arrangement. Details are as follows:- (a)Angle iron post to post distance maintained not more than 03mtr ,size of angle shall be 50x50x6mm.Angle Iron shall be embedded in natural ground not less than 0.90 m deep. (b)Ms wire 75x75mm mesh 4mm dia ,2mtr height and shall be fixed to post with flat iron 32 x 6 mm fillet with two coats of synthetic enemel paint over a coat of red oxide primer. (c)Cement concrete type D-2 ,1:4:8 using grade crushed stone aggreagte for mass concrete/ foundation. (d)Brickwork with subclass 'B ' bricks ,straights or curved on plane exc 6m mean radius ,built in cement mortar 1:6 complete for toe wall along the perimetre fencing.The toe wall shall be one brick thick,30cm high (15cm above GL and 15cm below GL) on 75mm thick PCC lean concrete. (e) The exposed surfaces of brickwork shall be rendered 15mm thick in CM (1:4) finished fair and even without using extra cement. (f) The steel gate shall be of size 1.00m x2.00 m fabricated from angle iron 40x40x5 mm frame and 25x25 mm square guard bars. (g) All the exposed surfaces of steel shall be painted with two coats of Synthetic enamel paint over one coat of Red Oxide Primer. (h) Necessary excavation and eathwork shall be included in the quoted rate.
Supply, installation, testing and commissioning of manufacturer’s factory manufactured and tested sheet steel clad / enclosed HT Vacuum Circuit Breaker (VCB) switchgear, indoor type, dust & vermin proof, motorised as well as manually charged, fully interlocked, horizontal draw out horizontal isolation type, floor mounted, 11 KV, 800 Amps aluminium busbar, 3 phase, 50 Hz, 21 KA/3 sec as per IEC 62271-200, extendable type, to be coupled with existing VCB make CG, type UNIVAC including adapter panel (if reqd). The charging time of motor shall be less than 15 Sec making it suitable for rapid auto reclosing duty and safety shutters shall be provided to cover up the fixed high voltage contacts on bus bar and cable side when the bus trunk is moved to test/isolation position with all standard accesssories and metering equipments and comprising of followings complete all as specified. (01 Incomer, 01 Bus copuier, 01 Outgoing) (a) Three single phase horizontal draw out type resin cast line type potential transformer of 11KV/110 volts, 50VA burden per phase class 1.0 accuracy connected star/star on HV side with HV&LV fises, isolating plugs, for HV side and LV connection.(01 Incomer, 01 Bus copuier) (b) CT dual ratio, 200/100/5+5 Amps rating, class 5P10 for protection & class 1.0 for metering 10 VA burden, short time rating 21 KA for 0.1 sec suitable for 11 KV - 03 Nos.
(c) Instrument & Protection Panel - Numerical relay with LCD display, 3 OC+1 EF, trip circuit supervision function, inrush protection, record and store at least 500 Events with Date and Time stamp, Last 10 Fault Records stored in Nonvolatile memory, Disturbance recording, self supervision function, 4 CT & 3 PT analog input, 8 DI & 6 DO, negative sequence currents, circuit-breaker-failure alarm, tripping circuit failures, Communicable on 61850 protocol, Breaker Control (ON/OFF) feature, suitable with 18 to 50 VDC complete with separate master trip relay. (d) Digital Voltmeter and Amp Meter, Digital Multifunction Meter (Accuracy class 0.5) with LCD display for measuring of current, voltage, power, power-factor, energy parameters, Total Harmonic Distortion and Maximum Demand Indication etc and shall have RS-485 port for communication on ModBus protocol. (e) LED indicating lamps for Breaker ON, Breaker OFF, Spring charged, TCH, Auto trip indicator, DC Supply ON, RYB phase indications. (f) T&C Switch for closing / tripping of VCB and Local Remote switch. (g) Heater with switch, thermostat and illumination. (h) 3 Pin plug socket with switch. (j) 01 No shunt trip coil and closing coil 24V DC (k) Emergency switch
M&L 25x3mm galvanised iron strip for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in pipe or any other indicated situation for loop earthing etc complete all as specified and directed.
Supply and laying XLPE insulated, screened, PVC bedded steel strip/wire armoured heavy duty electric cable suitable for 11KV earthed system of cross sectional area 3 core 240 Sq mm complete all as specified and directed..
S&F Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 3 core 120 sqmm complete all as specified and directed..
S&F sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as directed by Engineer-in-Charge. Note : Measurement shall be taken after putting down.
Supplying, laying, jointing testing and connecting XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, IS 7098 marked, suitable for HT 1100 V system, laid in trenches fixed to pole, including jointing & testing complete all as specified and directed of following sizes:- Note :- Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately under respective items of schedule.
16 Sqmm 4 core
35 Sq mm 3.5 core.
95 Sq mm 3.5 core.
185 Sqmm 3.5 core
Supply, fixing and testing straight through joint heat shrinkable type with jointing kit suitable for cable PVC/XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade of following size complete all as directed.
35 sqmm x 3.5 core
95 sqmm x 3.5 core
185 sqmm x 3.5 core
OUTGOINGS:- (i) MCCB 4 pole, 250 Amps, microprocessor based 50 Hz, 415 Volts, 36 kA - 01 No. (ii) MCCB 4 pole, 125 Amps, microprocessor based 50 Hz, 415 Volts, 10 kA - 02 No. (iii) Onload change over motorised type 200A Note:(i) All incoming and outgoing feeder shall be connected by cable through suitable size glands & thimples. (ii) The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint. (iii) All MCCB should be connected to Bus bar directly through expended links (iv) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt. II/1993 (Latest Version). The MCCB should have Ics=100% Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacture.
All as per item No 21 here in before but comprises of following:- Incoming (i)125A automatic transfer switch-01. Outgoing (i) MCCB 100A Breaking capacity 10KA-01. (ii) MCCB 40A Breaking capacity 10KA-01.
Supply & Fix fiber/GRP KIOSK box weather proof incluiding made out of one piece mounted SMC base and door pole mounted hinged door size 333x233x120 mm out side and 300x200x105 mm inside dimensions comprising of aluminium bus bar 4 strip for 3 phase and neutral 63 Amps and 02 A SP MCB with base incluiding embossing/ painting of danger notice of size not less than 10cm x 7.5 cm with letters,figures band conventional skull and bones in signal red colour on front face of KIOSK box body complete all as specified and directed.
Boring of hole under road/pavement/hard standing or any other situation by mannual means and suitable for passing of GI pipe 40 to 100 mm bore and making good both ends all specified and directed
S&F in replacement GI Pipe (light grade) with necessary accessories/ fittings for cable protections/pole for crossing of culverts/nallah of 50 mm bore sizes
S&F in replacement GI Pipe (light grade) with necessary accessories/ fittings for cable protections/pole for crossing of culverts/nallah of 100 mm bore sizes
Supply, installation, commisioning and testing of LT415 Volts 50 Hz, Automatic street light switch with nature switch using infrared sensor technology, Maximum load 5 KW & 2 KW per phase. ( a) MCB SP C32-03 Nos, NCN 120NC20-03 Nos & JPG 216 AC3 -16 A-03 Nos. (b) Panel wiring with single core copper flexible cable 1.5 Sqmm PVC insulated, 1100 volts grade from switch connector fuse to including copper lugs and sensor wiring contactor coil wiring with 1.5 Sqmm copper cable PVC insulated including copper lugs of proper size. (c) Complete cable connections of incoming/outgoing cables and testing on load after completion of work all as specified. (d) water resistence PVC enclosure size 38cmx28cmx18cm, complete with cable glands, Hingeses, locking arrangement & fixing on pole/wall- 01 Each Job
S&F LED street light fitting 45 watt pressure dia cast aluminum housing, heat resistant toughened class with frame, IP 66 protection and better optics for uniform distribution Cat Ref : Nexus LSTO-45-CDL of Crompton or equivalent.
S&F LED flood light fitting 60 watt pressure dia cast aluminum housing, heat resistant tempred glass for protection with integreated driver 5 KV surg protection applicable for large area lightning, IP 66 protection along with fixing bracket. Cat Ref : Secure LSFO-200-CDL/60 of Crompton or equivalent. Note : Rate quoted includes the MS angle iron for fixing of flood light on PCC/steel tubler pole.
S&F PVC two core copper conductor 2.5 sqmm for connection of light fitting.
Taking down old u/s ACSR conductor of any type or size from the pole complete all as specified and as dierected.
NOTE :-(i)contractor should provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Eng-in-charge.
M P TYAGI ENGINEERS AND CONTRACTORS
Vijay Electricals
Ridhi engineers and builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .