Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 LAdmitted-Finance | ₹2.4 L | L1 | Admitted-Finance |
| 2 | L2₹2.5 LAdmitted-Finance | ₹2.5 L | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical Disqualified in TC Bid Evaluation process |
| Sl No | Description | Qty | Unit | C M AIRCONDITIONING AND ELECTRICALS L1 | M.PSC L2 |
|---|---|---|---|---|---|
| 1.00 | Dismantling the existing window AC units cables and starters etc. as required and shifting to the other rooms/storage locations of the same building etc. as required. | 10 | Job | 400 ₹4,000 | 420 ₹4,200 |
| 2.00 | Dismantling the existing Split AC units i.e. indoor unit, outdoor unit, copper pipes, cables and starters etc. as required and shifting to the other rooms/storage locations of the same building etc. as required. | 8 | Job | 700 ₹5,600 | 680 ₹5,440 |
| 3.00 | Closing the existing wall openning of 1.5 TR WAC units by bricks wall with neat cementing plastering, white washing, painting with matching colour of existing paints or with provision of suitable size of MS frame with S/F of glass in the existing frame etc completet as required. | 6 | job | 1,550 ₹9,300 | 1,500 ₹9,000 |
| 4.00 | Shifting of 1.5 TR WAC unit from Door Sanchar Bhawan to TE Chandrasekharpur & reinstallation of WAC unit in the existing position etc complete as required. | 1 | job | 950 ₹950 | 1,000 ₹1,000 |
| 5.00 | Installation, testing, & commissioning of 1.5 Ton/2.0 Ton Inverter Split A.C. Unit, mounting / fixing of indoor & outdoor unit,fixing of refrigerant piping with expanded polythene foam insulation, suitable size PVC pipe in wall crossings, laying of cable for interconnections and laying drain pipe of standard length which is supply along with AC unit, minor civil work i/c making holes on wall for laying refrigerant pipe lines, control cable and drain pipes and closing the extra openings, making good the damages etc. as reqd. | 5 | Each | 2,400 ₹12,000 | 2,400 ₹12,000 |
| 6.00 | Providing and fixing of suitable size L- shaped powder coated MS bracket (2 nos. per set ) on wall with suitable size anchor bolts for fixing of the outdoor unit of the split A/C units, drilling holes etc. complete as reqd. | 5 | Set | 1,000 ₹5,000 | 1,050 ₹5,250 |
| 7.00 | Providing & laying of refrigerant copper pipe for suction & discharge line (size not less than 1/4" & 1/2" dia ) or as recommended by the manufacturer along with expanded polythene foam insulation i/c cutting ,brazing /making joint etc as reqd. The measurement shall be taken on linear basis for one circuit which includes suction & discharge line & foam insulation. | 85 | Mtr | 1,700 ₹1.4 L | 1,720 ₹1.5 L |
| 8.00 | Supplying & laying of 4 core 2.5sqmm size PVC insulated & PVC sheathed copper conductor cable for inter connection of indoor and outdoor units of ACs etc as reqd. (ISI) | 85 | Mtr | 150 ₹12,750 | 190 ₹16,150 |
| 9.00 | Supplying & laying of 3 core 2.5sqmm size PVC insulated & PVC sheathed copper conductor cable for inter connection of indoor and outdoor units of ACs etc as reqd. (ISI) | 85 | Mtr | 150 ₹12,750 | 190 ₹16,150 |
| 10.00 | Providing and laying of drain pipe of size 20mm dia PVC braided/ solid (M class-ISI) along with all accessories and fixing on surface of wall with PVC saddles (if required) suitable for drainage of condensate water etc. as reqd. | 115 | Mtr | 120 ₹13,800 | 100 ₹11,500 |
Tender Value
₹2.8 L
EMD Value
₹5,645
Closing Date
5 Mar 2026, 3:00 pmClosed
O/o the Executive Engineer (E), BSNL, Bhubaneswar
Door Sanchar Bhawan, Unit-IX, Bhubaneswar-751022
Dismentalling and Reinstallation of WAC and SAC units
2026_BSNL_268431_1
66/BSNL-EDB/ET/2025-26
Open Tender
Electrical Works
30 days
Bhubaneswar BA
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
Yes
A.O (Cash) BSNL, O/o GMTD, Bhubaneswar
₹5,645
Yes
31 Mar 2026
24 Feb 2026
6 Mar 2026
24 Feb 2026
5 Mar 2026
24 Feb 2026
24 Feb 2026 - 3 Mar 2026
Dismantling the existing window AC units cables and starters etc. as required and shifting to the other rooms/storage locations of the same building etc. as required.
Dismantling the existing Split AC units i.e. indoor unit, outdoor unit, copper pipes, cables and starters etc. as required and shifting to the other rooms/storage locations of the same building etc. as required.
Closing the existing wall openning of 1.5 TR WAC units by bricks wall with neat cementing plastering, white washing, painting with matching colour of existing paints or with provision of suitable size of MS frame with S/F of glass in the existing frame etc completet as required.
Shifting of 1.5 TR WAC unit from Door Sanchar Bhawan to TE Chandrasekharpur & reinstallation of WAC unit in the existing position etc complete as required.
Installation, testing, & commissioning of 1.5 Ton/2.0 Ton Inverter Split A.C. Unit, mounting / fixing of indoor & outdoor unit,fixing of refrigerant piping with expanded polythene foam insulation, suitable size PVC pipe in wall crossings, laying of cable for interconnections and laying drain pipe of standard length which is supply along with AC unit, minor civil work i/c making holes on wall for laying refrigerant pipe lines, control cable and drain pipes and closing the extra openings, making good the damages etc. as reqd.
Providing and fixing of suitable size L- shaped powder coated MS bracket (2 nos. per set ) on wall with suitable size anchor bolts for fixing of the outdoor unit of the split A/C units, drilling holes etc. complete as reqd.
Providing & laying of refrigerant copper pipe for suction & discharge line (size not less than 1/4" & 1/2" dia ) or as recommended by the manufacturer along with expanded polythene foam insulation i/c cutting ,brazing /making joint etc as reqd. The measurement shall be taken on linear basis for one circuit which includes suction & discharge line & foam insulation.
Supplying & laying of 4 core 2.5sqmm size PVC insulated & PVC sheathed copper conductor cable for inter connection of indoor and outdoor units of ACs etc as reqd. (ISI)
Supplying & laying of 3 core 2.5sqmm size PVC insulated & PVC sheathed copper conductor cable for inter connection of indoor and outdoor units of ACs etc as reqd. (ISI)
Providing and laying of drain pipe of size 20mm dia PVC braided/ solid (M class-ISI) along with all accessories and fixing on surface of wall with PVC saddles (if required) suitable for drainage of condensate water etc. as reqd.
Providing and laying of additional drain pipe of size 25mm dia PVC braided/ solid (M class-ISI) along with all accessories and fixing on surface of wall with PVC saddles (if required) suitable for drainage of condensate water etc. as reqd.
Providing of R32 refrigerant gas (if required) and charging into the Inverter Split AC unit etc. as reqd.
Supply and Fixing of MCB protected 3 pin socket outlet boxes with metal board consisting of 1 no 20 Amps 3 pin socket outlet with 20 Amps plug top and 1 no 20 or25 amps SP MCB of C series suitable for 220-230 volts single phase 50 Hz AC supply as required.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
techsummary_312413.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.04 MB
BOQ_312413.xls
BOQ • 7.16 MB
Download all tender documents and submit your bid