Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 CrAccepted-AOC AZADGARH 1150 9 124001 | ROHTAK | ROHTAK | HARYANA | 124001 | ₹1.7 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹1.8 Cr+₹14.7 L (8.87%)Rejected-AOC VPO KHARKHARI TEHSIL LOHARU DISTRICT BHIWANI HR | BHIWANI | HARYANA | 127021 | ₹1.8 Cr+₹14.7 L (8.87%) | L2 | Rejected-AOC Rejected |
Tender Value
₹1.7 Cr
EMD Value
₹3.4 L
Closing Date
31 Aug 2021, 6:55 pmClosed
EE PHED No.1 Rohtak
Jhajjar Road Rohtak
Recall Nigana Providing functional household Tap Connection construction of Raw water Pump house Augmentation of existing water works Laying of Distribution pipeline in village Nigana Construction of raw water sump well Near Kahanaur Distributary at
2021_HRY_184987_1
DNIT Approved vide SE Endst No.1755 dt.26.07.2021
Open Tender
Civil Works
Works
450 days
VPO Nigana
Please refer Tender documents.
3 documents required · 3 mandatory
₹15,000
₹3.4 L
Yes
23 Oct 2021
25 Aug 2021
1 Sept 2021
25 Aug 2021
31 Aug 2021
25 Aug 2021
Amount
WATER TREATMENT PLANT (WTP) Desinging , Testing , Commissioning of 0.50 MLD capacity Water Treatment Plant including inlet channel Alum dozing, Flash mixing, Clari floculator, filter box, over head Reservoir for back wash, waste water tank including all civil work pumping machinery and electric cabling, control panel, entire piping network of suitable size laying of DI pipes from raw water pump o inlet Box of WTP, WTP to CWT & Suction well for CW including , DI specials, suitable size sluice valves Hodies manhole covers, air scour equipment, chemical house including chlorination equipment and arrangement of flow measurement and sand bed with automation complete in all respects as per NIT (Sluice valve of make IVCAWAG )
Pumping Machinery
Raw water Pump Sets Supply & Eraction of Horizontal spindle split casing type pumping sets of following duties directly coupled to AC squirrel cage induction type motor with accessories as described in Schedule No II complete in all respect with priming arrangement with complete base frame. A ) For Raw water Pump House ( Near Kahanaur Distributory)
2400 LPM X 30 M Head & 30 BHP for Raw water
ii) Raw water Pump sets at water works 1800 LPM X 12 M Head & 10 BHP for Raw water
Supply and jointing three core cables of approved make with bare bunched copper conductor insulated and sheathed with PVC for Clear water & Raw water Pump motors/Fountain loghts etc with voltage grade 1100 volts marked with IS :694 1990 including cost of jointing, materials as well as carriage loading, unloading etc. complete in all respect upto the entire satisfaction of Engineer-in-charge
PANEL BOARDS FOR MOTORS Supply, erection, testing and commissioning of wall mounted electrical LT panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 500 x 1200 mm and 400mm deep having following item:-For Raw water Pump House) A ) Incomer Switch 100Amp. b Aluminum bus bar chamber of 200Amp. capacity c) Volt Meter 100x 100mm range of 0 to 500 Volt (AE/KAPPA/L&T) d) Indicating Lamp = One Set
Supply, erection, testing and commissioning of wall mounted electrical LT panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200 x 900 mm and 400mm deep having following item:-( At Raw water Pump House Near Kahanaur Distributory) For Raw water pump set 2400 LPM x 30 M. Head = 1Nos. ( One for Each Pump set) at Raw water pump house A ) Main switch 100 Amp 1 No. (L&T siemens, ABB). b) Volt Meter 100x 100mm range of range 0 to 500 Volt = 1 No. c) Amp Meter 100x 100mm range of range 0 to 100 Volt = 2 No. d) CT 100/3Nos. (AE/KAPPA/L&T) e) VSS 1 No. & ASS 1 No. each No. of approved make f) SPP 4 No. of approved make/minilac g Motor starter star delta 1 No. for 2400 LPM x 30 M Head Motor (L&T, Siemens, ABB) h) Capacitor KVAR as per site requirement i ) Indicating Lamp = One Set j) Change over Switch 200Amp. = 1 No.
Supply, erection, testing and commissioning of wall mounted electrical LT panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200 x 900 mm and 400mm deep having following item:-At W/W) For Raw water pump set 1800 LPM x 12.5 M. Head = 1Nos. ( One for Each Pump set) A ) Main switch 100 Amp 1 No. (L&T siemens, ABB). b Volt Meter 100x 100mm range of range 0 to 500 Volt = 1 No. (AE/KAPPA/L&T) c) Amp Meter 100x 100mm range of range 0 to 100 Volt = 2 No. (AE/KAPPA/L&T) d) CT 100/3Nos. (AE/KAPPA/L&T) e) VSS 1 No. & ASS 1 No. each No. of approved make f) SPP 4 No. of approved make/minilac g Motor starter star delta 1 No. for 1800 LPM x 12.5 M Head Motor (L&T, Siemens, ABB) h) Capacitor KVAR as per site requirement i ) Indicating Lamp = One Set j) Change over Switch of suitable 63 Amp. = 1 No.
Supply, erection, testing and commissioning of wall mounted electrical LT panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200 x 900 mm and 400mm deep having following item:-At W/W) For Clear water pump set 1800 LPM x 45 M. Head = 1Nos. ( One for Each Pump set) A ) Main switch 100 Amp 1 No. (L&T siemens, ABB). b Volt Meter 100 x 100mm range of range 0 to 500 Volt = 1 No. c) Amp Meter 100x 100mm range of range 0 to 100 Volt = 2 No. (AE/KAPPA/L&T) d) CT 100/3 Nos. (AE/KAPPA/L&T) e) VSS & ASS 1 No. each No. of approved make f) SPP 4 No. of approved make/minilac g Motor starter star delta 1 No. for 1800 LPM x 45 M Head Motor (L&T, Siemens, ABB) h) Capacitor KVAR as per site requirement i ) Indicating Lamp = One Set j) Change over Switch of suitable 200 Amp. = 1 No. (each)
Operation and maintenance for complete scope of work mention in the DNIT ( Disinfection material supplied by the PHED) as per Schedule-IV for a period 5 year after 12 month during defect liablity period 3 months trial run will be charged to the A/Mtc estimate
Operation and maintenance during defect liability period (Operation only)
Operation and maintenance during 1st year
Operation and maintenance during 2nd year
Operation and maintenance during 3rd year
Operation and maintenance during 4th year
Operation and maintenance during 5th year
Bidder Name
Amount
Pardeep Kumar Contractor(GSTN-06AQDPK9866B1ZR)
Sudhir Singh Contractor(GSTN-06BBNPS3903D1ZP)
Pardeep Kumar Contractor
Pardeep Kumar Contractor
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .