| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.9 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹11.4 L+₹14,440 (1.28%)Rejected-Finance | L2 | Rejected-Finance Higher Bidder | |
| 3 | L3₹11.5 L+₹20,410 (1.81%)Rejected-Finance H NO 37 VIKAS VIHAR PHASE II FEROZEPUR CITY PB 152002 | FEROZEPUR CITY | FEROZEPUR | PUNJAB | 152002 | L3 | Rejected-Finance Higher Bidder | |
| 4 | L4₹12.0 L+₹69,598 (6.18%)Rejected-Finance | L4 | Rejected-Finance Higher Bidder | |
| 5 | L5₹12.1 L+₹87,993 (7.81%)Rejected-Finance | L5 | Rejected-Finance Higher Bidder |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
21 Dec 2023, 6:00 pmClosed
CWE Ferozepur Cantt
HQ CWE Ferozepur Cantt
REPAIR/MAINT OF LIGHTENING CONDUCTOR,STREET LIGHTS AND CONNECTED WORKS AT ASD AREA UNDER GE(EAST) FEROZEPUR CANTT
2023_MES_629530_1
CWE/FZR-30/2023-24
Open Tender
Civil Works
Item Rate
180 days
Ferozepur Cantt
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE(East) Ferpzepur Cantt
₹30,000
27 Jan 2024
23 Nov 2023
29 Dec 2023
23 Nov 2023
21 Dec 2023
8 Dec 2023
Amount
Carrying out servicing/maint of 75/62.5/50 KVA DG set, Make : 'Greaves/Kirloskar' including 'B' check as per manufacturers mannual through authorised dealer of DG set manufacturer of existing DG Make and testing of DG set complete all as specified and as directed by Engineer-in-Charge. Note :- All material/spares parts required for carrying out above maintenance/servicing shall be measured and paid separetely as mentioned below and shall be of make-Greaves/Kirloskar/Cummins as per make of DG set and labour element required for replacing the spares parts including replacement of minor spare parts which are essential for carrying out servicing/maintenance of DG sets shall deemed to be included in the unit rate quoted by the tenderer against item No.1 above.
Supply and fixing in replacement of Lub oil filter of 75/62.5/50 KVA DG set complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement of Fuel filter insert of 75/62.5/50 KVA DG set complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement of Fuel pre filter of 75/62.5/50 KVA DG set complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement of Air clean element of 75/62.5/50 KVA DG set complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement of Hose pipe & Flexible pipe of 75/62.5/50 KVA DG set complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement of Fan belt for water pump of 75/62.5/50 KVA DG set complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement of Fan belt for alternator dynamo of 75/62.5/50 KVA DG set complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement of Exhaust Silencer of 75/62.5/50 KVA DG set complete all as specified and as directed by Engineer-in-Charge
All as per item No. 1 here in before but for DG Set of capacity 40/30 KVA of any make complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement of Lub oil filter of 40/30 KVA DG set complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement of Fuel filter insert of 40/30 KVA DG set complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement of Fuel pre filter of 40/30 KVA DG set complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement of Air clean element of 40/30 KVA DG set complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement of Hose pipe & Flexible pipe of 40/30 KVA DG set complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement of Fan belt for water pump of 40/30 KVA DG set complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement of Fan belt for alternator dynamo of 40/30 KVA DG set complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement of Exhaust Silencer of 40/30 KVA DG set complete all as specified and as directed by Engineer-in-Charge
Repair/servicing of radiator assembly of 75/62.5/50 KVA DG set (Greaves/Kirloskar/ Cummins) after dismanteling and removing cooling fans, guard plates and lowering the same from engine after draining out water from radiator and scrapping / removing sludge / scale inside tank with acid including replacement MS tank (botom portion) at rusted portion by cutting/ welding / brazing with 2mm thick copper plate including painting. Remounting the same at its original position and repalcement of pre mixed coolent as per the ratio fixed by manufacturer and testing complete all as specified and as directed by Engineer-in-Charge. (Note- Pre mixed coolent shall be measured and paid separately under relevant item of schedule)
All as per item No. 19 but for 30 to 40 KVA DG Set of Greaves /Cummins / Kirloskar complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement of new Self starter, auto lock, 12/24V of existing make, on the 75/62.5/50 KVA DG set and taking out u/s self starter from DG set. complete all as specified and as directed by Engineer-in-Charge
All as per item No. 21 but for 30 to 40 KVA DG Set complete all as specified and as directed by Engineer-in-Charge
Taking down unserviceable Self starter from the DG Set 30 to 75 KVA including dismantling the Self starter and taking out burnt winding armature & field coil and cleaning the slot including re winding of armature, field coil with enameled copper conductor of existing gauge including insulating material and heat varnish. Replacing worn out armature auto lock-01PC,Carbon brushes set, Pinion set, copper bush Set, Guard piece rubber, carbon rocker, Solinoid coil and reassembling the Self starter and mounting on its original position by replacing worn out nut bolts washers including painting of self starter complete all as specified and as directed by Engineer-in-Charge
Repair/Servicing of water pump and replacement of water kit and water seal of 30 to 75 KVA DG Set complete all as specified and as directed by Engineer-in-Charge
Dismantling and taking down alternator assembly from existing engine and transporting to workshop and carry out servicing / maintenance of alternator unit of capacity 75/62.5/50 KVA DG set as per the phase work :- (a) Opening of Alternator and cleaning / remvoing dust from armature and field coil. (b) Cleaning of used / old lubricated substances drive/non drive end bearings. (c) Cleaning end cheeking of AVR unit (d) Cheking and tighting of coupling bolts and replacement of rubber inserts. (e) Material and labour for carrying out heat varnishing for field and armature coil and kept in heating chamber for 48 hours for drying properly. (f) Replacement of Bearings as per existing size. (g) Reassembling complete unit and carrying out testing at workshop and transportation to installation and coupling with DG Set including necessary alignment, cable connectionscomplete all as specified and as directed by Engineer-in-Charge
All as per item No. 25 but of cpacity 30 to 40 KVA DG Set complete all as specified and as directed by Engineer-in-Charge
Rewinding of armature with super enamelled copper of required size wire including varnishing, sleeves, cotton tape and heating etc. for DG Set of capacity 62.5 KVA to 75 KVA, complete, complete all as specified and as directed by Engineer-in-Charge Note : cost of winding wire shall be included in quoted rate.
All as per srl item No 27 here-in-before but for 30 KVA to 40 KVA DG set complete all as specified and as directed by Engineer-in-Charge
Dismantling, rewinding of field coils of alternator with super enamelled wire including varnishing and heating including reassembling and testing for capacity of DG Set 75/62.5/50 KVA, complete, complete all as specified and as directed by Engineer-in-Charge. Note : Cost winding wire shall be included in quoted rates.
All as item No 29 here-in-before, but for 30 KVA to 40 KVA DG set complete all as specified and as directed by Engineer-in-Charge
Supply & fixing Ball bearing suitable for 30 to 75 KVA DG set complete all as specified and as directed by Engineer-in-Charge
Supply & fixing rotating rectifier assy Diodes (set of 6 Nos) complete all as specified and as directed by Engineer-in-Charge
Material and labour for dismantling, opening of diesel engine cylinder head, removal of unservieable worn out spare parts, cleaning of all components, reboring of cylinder on lathe machine, after reboring honning process will be carrred out,replacement of all spare parts and gaskets as per manufacturer spare part kit, re-assembling of complete engine setting, timing setting for the capacity of 50 to 75 KVA DG set complete all as specified and as directed by Engineer-in-Charge. Note:- Spare parts will be measured and paid seperately under respective item of BOQ.
Supply and fixing in replacement of Piston ring set suitable for 50 to 75 KVA DG set of existing make complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement of Cylinder liner ‘O’ ring kit suitable for 50 to 75 KVA DG set of existing make complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement of Main bearing set suitable for 50 to 75 KVA DG set of existing make complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement of Oil pump assembly with drvg gear suitable for 50 to 75 KVA DG set of existing make complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement of Valve (inlet and outlet valve) suitable for 50 to 75 KVA DG set of existing make complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement of Head gasket suitable for capacity of DG Set 50 to 75 KVA DG set complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement of Head gasket suitable for capacity of DG Set 30 KVA to 40 KVA complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement of Voltmeter 0-500 Volt square or otherwise flush pattern of existing size complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement of Ammeter any range flush pattern size as existing complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement of Indicator Lamp (RYB) complete all as specified and as directed by Engineer-in-Charge
Supply & Fixing for replacement of Battery charger (UPS) upto 250 AH, 12 Volts, single Phase AC supply 230V, 50 Hz including all type indicators, showing charging complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement of sheet metal enclosure type change over switch on load front handle four pole 415 volts 50 Hz 100 Amps including mounting arrangement of metallic frame work of appropriate section and size on walls or panels complete all as specified and as directed by Engineer-in-Charge Note:- Making connections to the electric system, including cutting of cable of any size and type, making end termination by using suitable lugs is included in the rate quoted under this item.
Supply and fixing in replacement of sheet metal enclosure type change over switch on load front handle four pole 415 volts 50 Hz 160 Amps including mounting arrangement of metallic frame work of appropriate section and size on wallsor panels complete all as specified and as directed by Engineer-in-Charge Note:- Making connections to the electric system, including cutting of cable of any size and type, making end termination by using suitable lugs is included in the rate quoted under this item.
Disconnecting, taking out carefully old unserviceable AVR unit, supply and fixing, connecting and testing new AVR unit suitable for DG set upto 75 KVA capacity complete all as specified and as directed by Engineer-in-Charge
Supply & pouring lubrication oil SAE-40 ( 15 W- 40 grade) complete all as specified and as directed by Engineer-in-Charge
Supply and filling of inhibitor corrosion (Fleet-Guard make Coolant) suitable for radiators of 30 KVA to 75 KVA capacity DG set complete all as specified and as directed by Engineer-in-Charge
Disconnecting and taking out the exhaust system of DG set of any capacity and carrying out cleaning of chocked, carbonized exhaust pipe including exhaust .silencer with de-scaling solution, including soldering / gas welding of leakage of pipe. Cutting the rusted portion of pipes including gas welding of pipes assembling the complete exhaust assembly including replacement of gasket, metallic flexible pipe, nut bolts, and testing for making it leak proof and fixing the same in position and testing the system complete all as specified and as directed by Engineer-in-Charge
Supply and fixing Exhaust gas muffler for 30 KVA to 75 KVA for silent type catalytic converter complete complete all as specified and as directed by Engineer-in-Charge
Supply and fixing of exhaust MS pipe by welding with existing silencer system with necessary hinges & clamp system incl wall cutting & minor plaster work all as reqd at site complete all as specified and as directed by Engineer-in-Charge
Taking out carefully unserviceable fuel injector pump assembly of 30 to 75 KVA DG set, cleaning/ oiling/servicing fuel injector pump assembly, recalibration of Fuel Injector Pump after replacing unserviceable nozzles, re-assembling and fixing the same in position and testing the Fuel Injector Pump assembly complete all as specified and as directed by Engineer-in-Charge Note (i) Repairs/servicing / reassembling and testing of Fuel injector pump shall be carried out through a authorised service center on fully automatic testing machine. (ii) The quoted rates against the item shall deem to includ for fixing the serviceable parts in position and replacement of unserviceable parts with new parts, such as nuts, bolts, washers, locking nuts,’O’ rings, nozzle, plunger, barrel, governor plunger, pressure regulator, weight carrier assembly, spring pack assembly, gear pump repair kit etc.New spare parts will be measured & paid seperately as Supply and fixing in replacement of (iii) The quoted rates shall deemed to be included cost of transportation to and from authorized service centre.
Supply and fixing in replacement of ECU: ELECTRONIC GOVERNOR B1 complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement of LEAK OFF PIPE FOR FIP & INJECTOR complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement of fuel pump bracket complete complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement of Gasket Governor set complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement of Ball Bearing complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement of Injector assembly with Nozzles & copper washers
Supply and fixing in replacement of Gasket hose complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement of Screen plate assembly complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement of Ball screw complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement of Seal ‘O’ ring complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement of Pump gear fuel complete all as specified and as directed by Engineer-in-Charge
Supply and laying for Dry and clean fine sand for cable cushioning to underground cable protection, complete all as specified. (Excavation and earth work measured separately) near area of Gen-Set's rating from 30 KVA to 75 KVA.Note- Punned down thickness shall be measured and complete all as specified and as directed by Engineer- in- Charge.
Supply and fixing as in repair stainless steel locking arrangement for DG set canopy gates rating from 30 KVA to 75 KVA complete complete all as specified and as directed by Engineer-in-Charge
Supply & fixing Battery Terminals Copper.(Positive & Nagative) complete all as specified and as directed by Engineer-in-Charge
Supply & fixing Battery Copper cable Red with plug complete(1 Mtr Length) complete all as specified and as directed by Engineer-in-Charge
Supply & fixing Battery Copper cable Black with plug complete (1 Mtr Length).
Supply & pouring K cool super plus-50-50 PREMIX of 1 Ltrs sealed Packing complete all as specified and as directed by Engineer-in-Charge
Material and labour for distilled water of lead acid battery complete all as specified and as directed by Engineer-in-Charge
Material and labour for repair of hinges of gate of DG set conopy incl the repair of gate of any cap complete all as specified and as directed by Engineer-in-Charge
Material and labour for Earthing complete, all as shown on electrical plate No 3 of MES schedule part-I , as specified including the following :-(i) Galvanised steel earth plate of size 60cmsx60cmsx6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.50 metre below normal ground level.(ii) Earth plate surrounded by and packed with char-coal and common salt in alternative layers (n.exc 15cms each layer).(iii) 4 mm dia (8 SWG) G.I earth wire from earth plate to main switch board including necessary GI bolts, nuts check nuts, washers, thimbles etc.(iv) 15 mm bore light grade, GI pipe for protection to earth-wire.(v) 20mm bore, medium grade, GI pipe for watering including GI funnel and wire mesh. Pipe shall be provided vertically upto top level of earth pit and then taken horizontally to the earth pit. (vi) 50mm thick pre-cast cover of cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate,Chamber in PCC(1:3:6),type-C2(to be constructed 1 m away from edge of earth pit) and MS angle iron 50x50x6mm frame including two coats of painting over a coat of red oxide to exposed steel surfaces.(vii) Excavation in soft/loose soil, returning filling & removal of surplus soil to a distance upto 50 metre as directed including testing etc all as specified.
Fixing in repair of existing aluminium strip 25mm x 3.15 mm with saddles and fixings screws etc for roof conductors and down conductors above ground complete all as specified and as directed by Engineer-in-Charge
Material and labour of aluminium strip 25mm x 3.15 mm with saddles and fixings screws etc for roof conductors and down conductors above ground complete all as specified and as directed by Engineer-in-Charge
Material and labour for Air termination,Single pointed aluminium rod 12mm dia and 300 mm long with base plate welded at bottom of termination rod 10 cm long fabricated out of 25 x 3 mm thick flat iron along with 9 mm dia fixing fasteners (wooden block) complete all as specified and as directed by Engineer-in-Charge
Fixing In repair of Air termination,Single pointed aluminium rod 12mm dia and 300 mm long with base plate welded at bottom of termination rod 10 cm long fabricated out of 25 x 3 mm thick flat iron along with 9 mm dia fixing fasteners (wooden block) complete all as specified and as directed by Engineer-in-Charge
Supply and fixing GI tube light grade of 50 mm dia bore galvanised,,with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by Engineer-in-Charge
Material and labour for test point terminal block made out of gun metal or phosphorus bronze size 75x 75x25mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hex head screw complete all as specified and as directed by Engineer-in-Charge
Fixing in repair test point terminal block of any type as per existing at site complete all as specified and as directed by Engineer-in-Charge
Material and labour Earthing complete with GI earth plate electrode 600 mm x 600mm x 6.3 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected to galvanised iron strip 25 x4 mm earthing lead by means of bolts, nuts, check nuts and washers protected by 15mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @15cm centre to centre both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers,necessary excavation & earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I and testing complete all as specified and as directed.
Disconnecting and taking down repairable LED type street light fitting of any type and capacity and make from existing 9 metre /11 metre pole for checking to find out the defects cleaning the glass and prefix cover, repair/replacement of spare parts including necessary wiring etc for making the fitting in serviceable condition and refixing in original position, testing etc complete all as specified and as directed by Engineer-in-Charge. Note : (i) The Spare parts will be measured and paid separtely. (ii) All type of T&P for repairing of street light should be provided by the contractor at own arrangememt.
Supply and fixing in replacement of LED driver 240Volt 50Hz for 60 to 90 watt LED fittings complete complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement of LED bulb set for street light set 240Volt 50Hz for 60 to 90 watt LED fittings complete all as specified and as directed by Engineer-in-Charge
Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp required to be fitted on High Mast Pole in replacement to U/S flood light complete all as specified and as directed by Engineer-in-Charge
Suplying and fixing 1100 volts grade heavy duty 6 Sq mm two core cable PVC insulated aluminium conductor, served with inner shething of PVC sheeathed in service conections suspended by insulating hangers and procelean beat not more than I metre apart including 4Sq mm suspension wire, one twin core cable flat or circular complete all as specified and as directed by Engineer-in-Charge
All as per item No 86 above but 10 Sqmm 2 core complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in repair LED Street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp, suitable GI Pipe bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete ccomplete all as specified and as directed by Engineer-in-Charge
Supply & fixing street light pole cable junction box with terminals IP-66 weather proof for outdoor installation with metric knockouts for cable entry and the box made out of thermal plastic material suitable for 16 sqmm cable including cable glands,clamps bolts, nuts duly painted complete all as specified and as directed by Engineer-in-Charge
Supply & fixing 3 core 1.5 sqmm PVC insulated and FR PVC round sheathed copper conductor flexible 1100 volts for connection from cable Junction Box to street light fittings complete all as specified and as directed by Engineer-in-Charge
Suplying and fixing in repair 1100 volts grade heavy duty 4 Sq mm two core cable PVC insulated aluminium Stranded conductor, served with inner shething of PVC sheathed in service conections one twin core cable flat or circular complete all as specified and as directed by Engineer-in-Charge
Material and labour painting to steel tubular pole with two coats aluminium paint over a coat of red oxide primer including preparation of old painted surfacecomplete all as specified and as directed by Engineer-in-Charge
DHAWAN CONSTRUCTION COMPANY
Karan Engineers
VK ENTERPRISES
M/s Manoj Construction Co.
PAWAN KUMAR GOVT. CONTRACTORS
ABHISHEK AND COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .